Manuel d'utilisation / d'entretien du produit C-10985 du fabricant Enviro
Aller à la page of 31
PELLET ST OVE Mini PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area.
2 Introduction.......................................................................................................... .........................3 Rating Label Location..................................................................................
3 Introduction * This manual is designed for the technician in conjunction with the owner’s manual. * R ATING L ABEL L OCATION : The rating label is located on the inside of the ash pan co ver . I MPORTANT S AFETY D ATA : Please read this entire Owner’s Manual before installing or operating this ENVIRO Pellet Stove.
4 Introduction ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical cord should be connected to a standard 110-120 volts,, nominal aver age 2.0 Amps (4 .1 Amps peak), 60 hertz electrical outlet and also must be accessible.
5 Inst alla tion D ECIDING W HERE TO L OCATE YOUR P ELLET A PPLIANCE : 1. Remo ve the right and left hand cabinet sides by loosening the three (3) T -20 T orx screws on the back of the each panel. 2. Remo ve the screw located on the front of the cabinet side, below the louvers and loosen the screw behind the ash door .
6 Inst alla tion A PPLIANCE D IMENSIONS AND S PECIFICATIONS : Figure 2: Dimensions of Mini. 15 1 / 2 " (393 mm) 18 7 / 8 " (481 mm) 17 1 / 2 " (444 mm) 19 5 / 8 " (497 mm) 17 7 / 8.
7 Inst alla tion C LEARANCES TO C OMBUSTIBLES : IMPORTANT: Attach the Mini’ s Hearth Pad when installing the unit on a combustible floor . The supplied hearth pad meet all the r equirement of a proper hearth pad. If y ou do not use the supplied hearth pad a hearth pad must be used when on combustible material.
fumes such as stairwells, cover ed breezeway , etc. 2. V ent surfaces can become hot enough to cause burns if touched by children. Non-combustible shielding or guards may be requir ed.
9 E XHAUST AND I NTAKE L OCATIONS : 10 1 / 16 " (255mm) 6 1 / 8 " (156mm) 2 1 / 16 " (53mm) Figure 8: Mini Inlet and Outlet Location. EXHAUST Base of unit to center of flue 10 1 / 16 ” (255 mm) Center of unit to center of flue 0” (0 mm) [at center of unit] FRESH AIR INTAKE.
10 Figure 10: Corner Installation. C ORNER T HROUGH W ALL I NSTALLATION : 3" (75mm) 3" (75mm) W all thimble manufactured by pellet vent manufacturer .
Inst alla tion H ORIZONTAL E XHAUST T HROUGH W ALL I NSTALLATION : Vent installation: install vent at clearances specified by the vent manufacturer. A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor , or ceiling.
12 Wall framing Wall thimble Termination cap Vertical section of vent pipe Horizontal frame for thimble 90° elbow Concrete Wall Clean out tee Wall framing Wall thimble Termination cap Vertical section of vent pipe Horizontal frame for thimble Clean out tee 90° elbow Wall strap Figure 13: V enting horizontally with rise.
.
14 Inst alla tion H EARTH M OUNT I NSTALLATION : Rain cap Storm collar Seal plate (cover plate) Existing masonry flue V ent pipe (single wall stainless flex pipe or solid PL vent) Fireplace damper loc.
Inst alla tion E XTERIOR M OUNTED E XHAUST B LOWER (20-070): The Mini can be equipped with an externally mounted exhaust blower . This optional kit includes all components necessary to install the exhaust blower on any vertical w all surface. 1. Remove the left hand cabinet side by remo ving the two (2) screws down the front.
Inst alla tion T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - H ORIZONTAL T ERMINATION : Electrical Cable 90° Elbow 45°Elbow with Rodent screen or stainless steel termination h.
17 Roof Sheathing Rain Cap Roof Flashing Roof Rafters Ceiling Joists V ent Pipe Exterior W all Sheathing Outside V ent T ermination Inst alla tion T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - V ERTICAL T ERMINATION : F ollow the previous pages for through wall installations.
Inst alla tion T HERMOSTAT I NSTALLATION : If the unit has been placed in the HI / L OW mode, the unit will be taken to a low or idle setting when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will go to the setting that is displayed on the control board Heat Indicator .
19 If the fire should happen to go out and the heat output indicator has been set on the lowest setting, the Slider Damper should be pushed in slightly , decreasing the air in the firebox.
Inst alla tion O PTIONAL P ANEL K IT : This kit must be installed before the unit is started. 20 Figure 31: Screws at back of the cab side. Figure 29: Screws above door top corner .
21 Inst alla tion 1 2 3 Figure 32: Installing Hopper Lid. Installing Hopper Lid: 1. Attach the hopper brack ets to the back of the unit with a screw in each top holes of the br ackets (#1 in Figure 32). Do not tighten these screws until all six (6) screws are in place.
T roubleshooting DO NOT: ● Service the stove with wet hands. The stov e is an electrical appliance, which may pose a shock hazard if handled improperly . Only qualified technicians should deal with possible internal electrical failures. ● Do not remove f rom the firebox any screws without penetr ating oil lubrication.
23 T roubleshooting ü P oor Quality Fuel – Insufficient energy in the fuel to produce enough heat to keep the stove burning or operational. ü Exhaust T emperature Sensor failure. – Bypass sensor located on Exhaust Blower if sto ve now oper ates properly , the unit may require cleaning or a new sensor .
T roubleshooting 7. The convection blower will not function normally. ü Clean all grill openings at the back and below unit . ü Press the f an button; does the f an come on? Pr ess again to v erify that the blower turns on; if , not contact your local dealer for service.
25 W iring Diagr am Connect Thermostat Here Red Red Red Red Brown Brown Brown Brown White White White White White 115V White 220V Blue White White Orange Orange Orange Orange Yellow Yellow Grey Grey G.
P ar ts List Reference Number Description Part Number 1 120°F (49°C) Ceramic F an T emperatur e Sensor EC -001 2 Auger Motor - 115V EF-001 3 High Limit T emp Sensor 200°F (93°C) Manual Reset EF-01.
27 P ar ts List Reference Number Description Part Number 17 Firebox P anel Set with Insulation 50-1162 18 Side Louver 50-1163 19 Burn Pot 50-1166 20 Burn Pot Liner 50-1167 21 Burn Pot Bottom 50-1168 2.
P ar ts Diagr am - Components Mini - Components April 2005 28.
29 P ar ts Diagr am - Steel Mini - Steel Components April 2005 .
W arr anty Sherwood Industries Ltd. gives a five year limited warrant y on all steel manufactured parts. A one-year warr anty is provided on all electrical components.
31 NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Enviro C-10985 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Enviro C-10985 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Enviro C-10985, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Enviro C-10985 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Enviro C-10985, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Enviro C-10985.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Enviro C-10985. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Enviro C-10985 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.