Manuel d'utilisation / d'entretien du produit MD du fabricant Emerson
Aller à la page of 15
® ce c Installation and Maintenance Manual For IntelliGear Plus™ MD and BW1 V ariable Speed Drives UL is believ ed to be a registered trade name and/or trademark of Underwriters Laboratories, Inc. and is NO T owned or controlled by Emerson P o wer T ransmission.
IntelliGear Plus ™ V ariab le Speed MD Gearmotors 2 General Safety Instructions Thank y ou f or choosing an IntelliGear Plus Gear motor . • Read and f ollow all instructions carefully . • Disconnect and lock-out po wer bef ore installation and maintenance.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 3 Contents 1 General Information ................................................................................................................................ 4 1.1 General operating principle ....
IntelliGear Plus ™ V ariable Speed MD Gearmotors 4 General Information 1 - General Information 1.1 - General operating principle The IntelliGear Plus is a combination of a 3-phase induction motor and an integrated open loop v ector v ariable speed drive.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 5 1.5 - Description of cables and pr otection devices (Customer Supplied) NO TICE: When using a circuit-break er , it must be a motor circuit-break er (D cur ve). • Complywiththesizeofprotectionfuses .
IntelliGear Plus ™ V ariable Speed MD Gearmotors 6 1.8 - Dimensions 8.52 .39 .12 6.30 5.00 Ø .344 + .007 / -.002 HOLES Ø 4.72 Ø 3.94 5.90 11 .23 3.50 1.40 5.50 Ø .280 HOLES 4 @ 90º AS SHOWN Ø 3.1500 3.1493 CA TA LOG NUMBER CBN3001BSCB524.556 CCI 109 CCI NUMBER CCI 109-G 1 Ø V oltage Po w e r Model No.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 7 2 - Installation After connection, ensure that the seals are firmly in place, and that the screws and cab le glands are water tight to ensure drive protection. Clear any condensation from the drain holes at the bottom of the motor .
IntelliGear Plus ™ V ariable Speed MD Gearmotors 8 3.3 Wiring diagram based on standar d configuration NOTE: IF AUTO MODE RUN/STOP CONT AC T IS NO T USED, 4-20m A INPUT CONNECTOR PINS 5 & 6 MUST BE JUMPERED TO RUN IN AU TO MODE.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 9 3.4 T erminal block assignments and MD functionality 4. Commissioning W ARNING! Before s witching on the IntelliGear Plus unit, check that the electrical connections are correct, and that any mo ving par ts are mechanically guarded.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 10 5. Operator Pad Each RPD IntelliGear unit has a ke ypad on the controller lid equipped with operator elements for H-O-A selection, manual control of unit, displa y of pump speed, faults and the ability to change some f actor y set parameters .
IntelliGear Plus ™ V ariable Speed MD Gearmotors 11 5. 1 Fault Mode T roubleshooting Guide 5.2 Additional T roubleshooting LED Pad Display Drive Status/Fault Indication Actions Required Blank Displa.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 12 5.3 Field Modifications Of P arameters The new IVD controller with k eypad allows some f actor y set parameters to be adjusted in the field. The table belo w provides the f actor y settings for each par ameter and then optional ranges f or selection of a new setting.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 13 6 - Gear Lubrication Series 3000 CbN gear ing is shipped with one of the f ollowing synthetic lubricants per the table belo w . The gear reducer has been filled to accommodate any mounting position.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 14 T ypical Maintenance Items - Bearings and Seals Rep Description Quantity 001 Housing 1 009 Output flang r ing 1 031 Output shaft 1 042 Pinion 1 0.
IntelliGear Plus ™ V ariable Speed MD Gearmotors 15 3 2 1 5 6 4 9 8 10 11 183 184 254 7 CbN 30 (Quantity P er Unit) FRAME 56 P art # Description Qty .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Emerson MD c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Emerson MD - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Emerson MD, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Emerson MD va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Emerson MD, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Emerson MD.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Emerson MD. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Emerson MD ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.