Page 1 of the Delta Linear Actuator (LA2-1-1025-33) user manual — 4886 LA2-1-1025-33
Page 1 · cliquer pour agrandir
Page 1

4886 LA2-1-1025-33

Part Number Amplifier Name

Revision 0.a Release Date April 2008 Revision Notes Initial release

Frequency Range: 1 - 1025 MHz P1dB: 2 Watts CW Class: A Supply Voltage: 28 V DC

Gain33dB Efficiency: 12% Temperature Range: 0 to 50 ° C Max VSWR: 10:1

This ultra broadband class A amplifier operates from below 1 MHz to over 1 GHz. Using all gold metallized LDMOS transistors and a stable design, this compact, high performance laboratory amplifier will find use in many applications. The LA2-1-1025-33 is offered as a standalone unit requiring the customer to mount to a modest heat sink, or we offer this with a heat sink. A disable line is option.

Delta Linear Actuator (LA2-1-1025-33) — 4886 LA2-1-1025-33 diagram (page 1)
Fig. 1
Delta Linear Actuator (LA2-1-1025-33) — 4886 LA2-1-1025-33 diagram (page 1)
Fig. 2

Phone +1.775 DELTA RF [775 335 8273]

Delta RF Technology, Inc.

Fax +1.775 DELTA FX [775 335 8239]

  • H i g h P o w e r R F A m p l i fi e r s a n d A c c e s s o r i e s 350 South Rock Boulevard
  • Reno
  • NV
  • 89502
  • USA
websitehttp://www.drft.com
emailsales@ drft.com

Technical Specifications Summary · Amplifier General Description · Amplifier Picture

Page 2 of the Delta Linear Actuator (LA2-1-1025-33) user manual — Electrical Specifications 4886 LA2-1-1025-33
Page 2 · cliquer pour agrandir
Page 2

Electrical Specifications 4886 LA2-1-1025-33

Parameter Min Typ Max Units Notes Frequency 1 1025 MHz P1dB 1.5 2 W, CW Psat 3 W, CW Amplifier is rated for this power into 1:1 load only Power Input 1 mW, CW For 2W output Gain 32 33 dB Noise Figure 3.5 4 dB Vsupply 24 28 V, DC Drain Current 0.5 0.70 A, DC Efficiency 12 % Input VSWR 1.5:1 Insertion Phase Variation 5° ° Unit to unit Gain Variation ±2 dB Unit to unit F2 Second Harmonic -45 dBc F3 Third Harmonic -45 dBc Baseplate Operating Temperature 0 40 °C High temperature at 3:1 VSWR Maximum

Physical Dimensions All specifications valid for 50 Ω output load, Vsup = +28VDC, Idq = 0.5A

Parameter Value Units Notes Maximum Operating Voltage 30 V, DC Stable Operating Voltage 24 - 30 V, DC Maximum Bias Current, Q100 0.065 A, DC Factory set, no user adjustment Maximum Drain Current, Q101 0.65 A, DC Factory set, no user adjustment Load Mismatch Survival 10:1 Up to 40°C Storage Temperature -40 to 85 °C Maximum Operating Baseplate Temp 50 °C Max 3:1 VSWR, 2W CW

♦ Amplifier Disable - optional

♦ SMA Female connectors RF INPUT and RF OUTPUT

♦ Solder connections for Vsup, Ground, Disable

Absolute Maximum Ratings · Features, Auxillary Functions

Page 3 of the Delta Linear Actuator (LA2-1-1025-33) user manual — Mechanical Specifications 4886 LA2-1-1025-33
Page 3 · cliquer pour agrandir
Page 3

Mechanical Specifications 4886 LA2-1-1025-33

Page 4 of the Delta Linear Actuator (LA2-1-1025-33) user manual — Graphs and Charts 4886 LA2-1-1025-33
Page 4 · cliquer pour agrandir
Page 4

Graphs and Charts 4886 LA2-1-1025-33

0 200 400 600 800 1000

0 200 400 600 800 1000

Graph 1. Gain, 2W Graph 2. P1dB

F2 Second Harmonic F3 Third Harmonic

0 200 400 600 800 1000

0 200 400 600 800 1000

Graph 3. Gain, 1W Graph 4. Harmonic Performance

All data taken at +28VDC

Show 12 more labels / short text on this page
Gain 2W · P1dB - Watts · Gain - dB · P1dB - Watts · Frequency - MHz · Frequency - MHz · Gain 2W · Harmonics · Harmonics - dBc · Gain - dB · Frequency - MHz · Frequency - MHz
Page 5 of the Delta Linear Actuator (LA2-1-1025-33) user manual — Integration and Operating Instructions 4886 LA2-1-1025-33
Page 5 · cliquer pour agrandir
Page 5

Integration and Operating Instructions 4886 LA2-1-1025-33

Attach amplifier to heatsink using thin layer of thermal compound. The amplifier will produce approximately 20W of heat, so a medium size heatsink will be adequate - a heatsink with approximate dimensions 2 x the area of the lab amp and approx 1.0” deep. A smaller heatsink may be used if any airflow is used.

Attach RF Input and RF Output using SMA Female connectors and tighten. Install ground wire and Vsup using solder connec- tions - make sure to attach positive wire to Vsup terminal. If optional disable is ordered, install using disable terminal on input side of amplifier.

To operate, apply Vsup and amplifier is ready to operate.

Page 6 of the Delta Linear Actuator (LA2-1-1025-33) user manual — Ordering Information 4886 LA2-1-1025-33
Page 6 · cliquer pour agrandir
Page 6

Ordering Information 4886 LA2-1-1025-33

Ordering Information: Order Code Description DRFT Reference LA2-1-1025-33 2W Broadband Laboratory amplifier module 4886 Options -A12 Heat Sink Option 0202 -A13 Heat Sink Option with DC Fan, pre wired 0203 -A14 Ruggedized for vibration 0204 -T2 Extended Burn In 0271 -T3 Extended Data Collection 0272

Standard Pallet Options: SMA Female Connectors, Input and Output. Stainless Body, Gold Center pin, 4-hole SMA bolted to pallet amplifier edge through bottom two holes located at amplifiers RF IN and RF OUT locations. All stainless steel hardware. Enclosure- all aluminum machined enclosure available for most pallet amplifiers. Alodyned aluminum, alloy 6061-T6. SMA Female input and output RF connectors. Supply voltage and ground through solder / feedthrough connections. Module must be bolted to appropriate heatsink. Heat Sink - aluminum extruded heat sink, black anodized. Pallet amplifier or module will be bolted to heatsink. Customer will be required to provide adequate airflow. Heat sink with fan - aluminum extruded heat sink as above, with included fan bolted to push air through the heat sink. Depending on heat requirements, a second fan may also be provided on the output of the unit. Ruggedized - all screws have threadlocking compound applied, and all flying components are staked and attached to base. Designed to withstand MIL-STD-810E 514.4 Category 8.

Testing Options: Standard - includes power test and brief burn - in under laboratory conditions. Printed test report gives graph of Gain and Input Return Loss at rated P1dB and Voltage Conditions. Report shows pass/fail critera. All amplifiers include this test. Extended burn in - 8-hour burn in at P1dB with standard test run at completion. Unit is monitored during test and any discrepancy reported. Standard test data is included. Extended data collection - Standard data is run and included. Detailed data is taken point by point giving the customer 25 - 70 frequency points, depending on the amplifier model. For each frequency point, data is generated to include gain, input power, input return loss, current, second harmonic, third harmonic, efficiency, audio distortion. Other tests available - Vibration, Temp cycling, Shock. Please inquire.

The specifications contained herein are subject to change without notice. Delta RF Technology, Inc. assumes no liability for the use of this information. This data sheet and contents are the property of Delta RF Technology, Inc. © Delta RF Technology, Inc. 2008.

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Delta Linear Actuator (LA2-1-1025-33)

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Delta Linear Actuator (LA2-1-1025-33)

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Delta Linear Actuator (LA2-1-1025-33) manuel PDF

6 pages·573 KB·Lecteur d'ordinateur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…