Manuel d'utilisation / d'entretien du produit Q-SCAN Q-Scan 250 du fabricant Chauvet
Aller à la page of 17
CHAUVET, 30 00 N 29 th Ct, Hollywoo d, FL 3302 0 U.S.A (800) 762-1084 – (954) 929-1 115 FAX (954) 929-5 560 www.chauvetlig hting.com 2005-11-1 5/13:24 Q-Scan ™ 250 250W HSD Intelligen t Scanner Q-.
Q-Scan 250 & Q- Roll 250 Use r Manual 2 2005-11-1 5/13:24 T able of Con tent BEFOR E Y OU B EGIN.......................................................................................................................................................
Q-Scan 250 & Q- Roll 250 Use r Manual 3 2005-11-1 5/13:24 Figure 1 - AC Voltage Switch B EFORE Y OU B EGIN What is included Q-Scan ™ 250 w it h MSD250 bulb or Q-Roll ™ 250 w ith MSD250bulb.
Q-Scan 250 & Q- Roll 250 Use r Manual 4 2005-11-1 5/13:24 I NTRODUC TION Technical Features Q-Scan ™ 250 Q-Roll ™ 250 Control Feature s 6-7 channel DMX Intelligent Scanner Pan: 180° .
Introduction Q-Scan 250 & Q- Roll 250 Use r Manual 5 2005-11-1 5/13:24 Product Over view Control Board Enter Choose Up Down SEGMENT BUTT ONS I/O PANE L OVERV IEW B UTTONS I/O P AN .
Q-Scan 250 & Q- Roll 250 Use r Manual 6 2005-11-1 5/13:24 S1 S2 S1 S ETUP Lamp You will need to in stall a lamp prio r to the initial operat ion of the fix ture.
Introduction Q-Scan 250 & Q- Roll 250 Use r Manual 7 2005-11-1 5/13:24 Slide switch up or down depending on your line voltag e. Lamp Alignmen t Screws are accessible via the rear plate.
Introduction Q-Scan 250 & Q- Roll 250 Use r Manual 8 2005-11-1 5/13:24 Mounting O r i e n t a t i o n Both fixtures can sit on stage or be mounted on a truss using a clamp in any pos ition, provided, there is adequate roo m for ventilation. W a r n i n g It is important never to obstruct th e fan or vents pathway.
Q-Scan 250 & Q- Roll 250 Use r Manual 9 2005-11-1 5/13:24 O PERA TING I NSTRUCTIONS Control Panel On the control pan el you can set the DMX address, set the fixture to Master/Slave mode, reset the fixture and change fixture per sonality traits.
Q-Scan 250 & Q- Roll 250 Use r Manual 10 2005-11-1 5/13:24 Note! If the fixture is con nected to a controller, please disconnect it. The display will r ead the previ ously selected setting . Only one fixtur e can be the Ma ster assigned fixtur e. However, 1 6 units can be slaved to t he master u nit.
Operating Instruc tions Q-Scan 250 & Q- Roll 250 Use r Manual 11 2005-11-1 5/13:24 Daisy Chain Connection D M X M o d e Operating in a DM X Co ntrol mode environment give s the user the gr eatest flexibility when it comes to customizing or creat ing a show .
Q-Scan 250 & Q- Roll 250 Use r Manual 12 2005-11-1 5/13:24 User Configurat ions P 1 - P a n I n v e r t / P 2 - T i l t I n v e r t It is possible to inv ert the pan and tilt mirror move ment from within th e fixture itself.
Q-Scan 250 & Q- Roll 250 Use r Manual 13 2005-11-1 5/13:24 A PPENDIX DMX Primer There are 512 chann els in a DMX -512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX -5 12 will require one or a number of sequential channel s.
Appendix Q-Scan 250 & Q- Roll 250 Use r Manual 14 2005-11-1 5/13:24 DMX Channel Value s (16 Bit) D EFAULT V ALUE F UNCTION 1 000 255 Pan Left > Right ( 128 = center) 000 255 Tilt (Q-Sc .
Q-Scan 250 & Q- Roll 250 Use r Manual 15 2005-11-1 5/13:24 Maintenance To maintain opti mum performan ce and minimize w ear fi xtures should be cleaned freque ntly. Usage and environ ment are contributing factors in deter mining frequency. A s a general rule, fix t ures should be cleaned at lea st twice a mon th.
Appendix Q-Scan 250 & Q- Roll 250 Use r Manual 16 2005-11-1 5/13:24 General Troublesho oting Applies to Symptom Solution(s) Lights Foggers & Snow Contr ollers Dimmers & Chaser Auto shut of.
Appendix Q-Scan 250 & Q- Roll 250 Use r Manual 17 2005-11-1 5/13:24 Technical Specific ations WEIGHT & DIMEN SIONS Leng th ........................................................................................................................
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Chauvet Q-SCAN Q-Scan 250 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Chauvet Q-SCAN Q-Scan 250 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Chauvet Q-SCAN Q-Scan 250, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Chauvet Q-SCAN Q-Scan 250 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Chauvet Q-SCAN Q-Scan 250, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Chauvet Q-SCAN Q-Scan 250.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Chauvet Q-SCAN Q-Scan 250. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Chauvet Q-SCAN Q-Scan 250 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.