FR
Bryan Boilers logo
Notice d'utilisation officielle

Bryan Boilers DST-40

2 pages·671 KB·Chaudière·PDF·EN
Bryan Boilers DST-40
Table des matières 4 sections TM BRYAN STEAM · Performance Features · Construction Features · Bryan Spray Type Deaerators — Horizontal and Integral AfficherMasquer
Page 1 of the Bryan Boilers DST-40 user manual — Construction Features
Page 1 · cliquer pour agrandir
Page 1

Form No. 6410

TM BRYAN STEAM

Spray Type Boiler Feedwater Deaerators Capacities 5,000 to 60,000 PPH (145 to 1740 BHP)

Bryan Boilers DST-40 — TM BRYAN STEAM diagram (page 1)
Fig. 1

Performance Features

  • Oxygen removal to .005 cc/l (7 PPB)
  • CO 2 removal to 0% measurable
  • Reduce chemical costs
  • Reduce boiler and system corrosion
  • Improve boiler efficiency
  • Pre-heat boiler feedwater
  • Quick equipment payback, compared to chemical oxygen removal

Construction Features

  • Constructed to ASME Section VIII, Division I for 50 PSIG
  • Easily accessible manway
  • Standard 10 minutes deaerated water storage
  • Internal vent condenser for minimum steam loss
  • Self-adjusting spring-loaded stainless steel spray valve
  • Structural steel stand/pump platform
  • 2-stage deaeration
  • Available as completely packaged unit including pumps and control panel

15,000 PPH unit shown

The Bryan spray type deaerator is rated for oxygen removal to .005cc/l (7 PPB) and CO2 to zero measur- able across its entire operating range. With its all stainless steel spring loaded spray valve and second stage steam scrubber, the spray type deaerator is a

good choice for all deaerator applications.

Units are available with a complete range of boiler feedpumps and control options making them a total deaerator package with minimal amount of field assembly.

Bryan Boilers DST-40 — Construction Features diagram (page 1)
Fig. 2 · Construction Features
Bryan Boilers DST-40 — Construction Features diagram (page 1)
Fig. 3 · Construction Features

(5/00) · Horizontal Tank Design · Integral Tank Design

Page 2 of the Bryan Boilers DST-40 user manual — Bryan Spray Type Deaerators — Horizontal and Integral
Page 2 · cliquer pour agrandir
Page 2

Bryan Spray Type Deaerators — Horizontal and Integral

Horizontal Integral Tank Tank Design Design 8 8 4 36" 4 C 15 1 5 6 11 16 C 15 1 5 6 11 16 3 3 2 10 7 2 10 14 14 7 13 9 12 13 9 12 48" * 48" * A A 1. High water level control *Note: Stand height varies depending upon pump specifications and job conditions. 2. Low water level control Dimensions are for reference only and may change without notice. Consult factory for certified dimensions. 3. Make-up water control 4. Vacuum breaker 5. Temperature gauge 6. Pressure gauge 7. Overflow trap Specifications 8. Vent 9. Pump suction Dimensions Capacity in inches (cm) 10. Pump bypass 11. Chemical port Model Storage A B C* Pounds/hr Boiler hp 12. Drain in gallons Overall Overall Overall (kg/h) (kW) (liters) length width height 13. Sample port 14. High temperature Horizontal Tank Design condensate return 5,000 145 200 15. Gauge glass DSH-5 124 (315) 36 (91) 52 (132) (2,268) (1,422) (757) 16. Manway access opening 10,000 290 200 DSH-10 124 (315) 36 (91) 52 (132) (4,536) (2,844) (757) 15,000 435 300 DSH-15 117 (297) 42 (107) 60 (152) (6,804) (4,267) (1,136) 20,000 580 400 DSH-20 120 (305) 48 (122) 64 (163) (9,072) (5,689) (1,514) 25,000 725 500 DSH-25 137 (348) 48 (122) 64 (163) (11,340) (7,111) (1,893) 30,000 870 600 DSH-30 156 (396) 48 (122) 64 (163) (13,608) (8,533) (2,271) Integral Tank Design 35,000 1,014 700 DST-35 143 (363) 48 (122) 104 (264) (15,876) (9,956) (2,650) 40,000 1,159 800 DST-40 156 (396) 48 (122) 104 (264) (18,144) (11,378) (3,028) TM 45,000 1,304 900 DST-45 141 (358) 54 (137) 110 (279) (20,412) (12,800) (3,407) 50,000 1,449 1,000 DST-50 171 (434) 60 (152) 120 (305) (22,680) (14,222) (3,785) Bryan Steam LLC — Leaders Since 1916 DST-60 60,000 1,739 1,200 177 (450) 60 (152) 120 (305) 783 N. Chili Ave., Peru, Indiana 46970 U.S.A. (27,216) (17,067) (4,542) Phone:765-473-6651 • Internet:www.bryanboilers.com ModelCapacityDimensions in inches (cm) Pounds/hr (kg/h)Boiler hp (kW)Storage in gallons (liters)A Overall lengthB Overall widthC* Overall height Horizontal Tank Design DSH-55,000 (2,268)145 (1,422)200 (757)124 (315)36 (91)52 (132) DSH-1010,000 (4,536)290 (2,844)200 (757)124 (315)36 (91)52 (132) DSH-1515,000 (6,804)435 (4,267)300 (1,136)117 (297)42 (107)60 (152) DSH-2020,000 (9,072)580 (5,689)400 (1,514)120 (305)48 (122)64 (163) DSH-2525,000 (11,340)725 (7,111)500 (1,893)137 (348)48 (122)64 (163) DSH-3030,000 (13,608)870 (8,533)600 (2,271)156 (396)48 (122)64 (163) Integral Tank Design DST-3535,000 (15,876)1,014 (9,956)700 (2,650)143 (363)48 (122)104 (264) DST-4040,000 (18,144)1,159 (11,378)800 (3,028)156 (396)48 (122)104 (264) DST-4545,000 (20,412)1,304 (12,800)900 (3,407)141 (358)54 (137)110 (279) DST-5050,000 (22,680)1,449 (14,222)1,000 (3,785)171 (434)60 (152)120 (305) DST-6060,000 (27,216)1,739 (17,067)1,200 (4,542)177 (450)60 (152)120 (305)
Bryan Boilers DST-40 — Bryan Spray Type Deaerators — Horizontal and Integral diagram (page 2)
Fig. 4 · Bryan Spray Type Deaerators — Horizontal and Integra…
Bryan Boilers DST-40 — Bryan Spray Type Deaerators — Horizontal and Integral diagram (page 2)
Fig. 5 · Bryan Spray Type Deaerators — Horizontal and Integra…

* Not including the stand.

©2000 Bryan Steam LLC 50-2517D

Poser une question sur : Bryan Boilers DST-40

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions