FR
Bryan Boilers logo
Notice d'utilisation officielle

Bryan Boilers DR250

2 pages·280 KB·Chaudière·PDF·EN
Bryan Boilers DR250
Table des matières 1 sections BRYAN BOILERS DR SERIES FORCED DRAFT STEAM BOILERS REVERSE CONSTRUCTION AfficherMasquer
Page 1 of the Bryan Boilers DR250 user manual
Page 1 · cliquer pour agrandir
Page 1
DR SERIES FORCED DRAFT 15# & 150# EFFECTIVE DATE: 12/9/03 STEAM BOILER (DR250-DR850) REVERSE CONSTRUCTION REPLACES: 10/29/03 NOTES: 1. ALL DIMENSIONS ARE IN INCHES THOSE IN PARENTHESES MINIMUM C ARE CENTIMETERS. BURNER 2. LOCATION DIMENSIONS SERVICE D ARE ALL ±1/2". AREA 3. GAS TRAIN, CONTROL AND (913 .6 4" 4) H A BURNER CONFIGURATION WILL B VARY DEPENDING ON JOB 10 15/16" (27.77) SPECIFICATIONS & CONDITIONS. 4. DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. CONSULT FACTORY FOR CERTIFIED DIMENSIONS. 33 13/16" (85.88) (229 ." 86) 5. ALL FLANGES ARE 150# UNLESS OTHERWISE NOTED, FLANGES TO STRADDLE CENTER LINE. MINIMUM 24" TUBE (60.96) REMOVAL G CLEARANCE 15 PLAN VIEW 9 7 19 1 14 3 5 4 10 Furnace Pressure 17 Tap 74 9/16" 18 2 16 (189.27) 59 7/8" 71 3/4" (152.08) (182.24) 11 13 26 3/8" (66.99) 12 6 8 FRONT VIEW RIGHT SIDE VIEW REAR VIEW 1. PROBE TYPE AUX. L.W.C.O. 2. FORCED DRAFT BURNER 3. RELIEF VALVE 4. ASME NAMEPLATE 5. LWCO/PUMP CONTROL - 1576. JACKET ACCESS PANELS 7. PRESSURE GAUGE 8. CLNOUT./INSP. OPNG.-1 1/2"NPT 9. ELEC. ENCLOSURE - 10. CLNOUT./INSP. OPNG. - 2" NPT11. DRAIN/ BLOWDOWN - 1" NPT 12. BURNER CENTER LINE 13. OIL PUMP LOCATION 14. LIFTING LUG 15. FEED CONNECTION 2" NPT16. HEIGHT OVER JACKET 17. HEIGHT OVER SUPPLY 18. MINIMUM SAFE WATER LEVEL 19. PRESSURE CONTROLS BOILER MODELDR250DR350DR450DR650DR850 A-LENGTH OVER JACKET33 3/4" (85.72)33 3/4" (85.72)33 3/4" (85.72)45 1/16" (114.45)45 1/16" (114.45) B-FLUE LOCATION13 3/4" (34.92)13 3/4" (34.92)13 3/4" (34.92)13 3/4" (34.92)13 3/4" (34.92) C-FLUE DIAMETER6" (15.24)6" (15.24)6" (15.24)8" (20.32)8" (20.32) D-LENGTH OVER BASE62 1/8" (157.79)62 1/8" (157.79)62 1/8" (157.79)73 1/2" (186.69)73 1/2" (186.69) G-SUPPLY NOZZLE SIZE3" (7.62)3" (7.62)3" (7.62)4" (10.16)4" (10.16) H-BURNER EXTENSIONCONSULT FACTORY FOR BURNER EXTENSION 783 NORTH CHILI AVE BRYAN BOILERS PERU, INDIANA 46970O RD ER N O .: ORDER REV. NO.: FORM NO.: 2178
Bryan Boilers DR250 diagram (page 1)
Fig. 1
Page 2 of the Bryan Boilers DR250 user manual — BRYAN BOILERS DR SERIES FORCED DRAFT STEAM BOILERS REVERSE CONSTRUCTION
Page 2 · cliquer pour agrandir
Page 2

BRYAN BOILERS DR SERIES FORCED DRAFT STEAM BOILERS REVERSE CONSTRUCTION

Form # >> 2178 Date >> 2/20/04

BOILER MODELDR250DR350DR450DR650DR850 INPUTMBH250350450650850 (KW)73.2102.5131.8190.4249.0 OUTPUTMBH200280360520680 (KW)58.682.0105.5152.4199.2 BOILER HORSEPOWERHP68101520 (KW)58.682.098.0147.0196.0 TUBE DIAMETERINCHES1.001.001.001.001.00 (CM)2.542.542.542.542.54 NUMBER OF TUBES1818182929 PRESSURE VESSEL VOLUME GAL 31 31 31 45 45 (L) 117.3 117.3 117.3 170.3 170.3 GAL3131314545 (L)117.3117.3117.3170.3170.3 HEATING SURFACESQ FT666666103103 (SQ M)6.16.16.19.69.6 STEAM OUTPUT* LBS/HR 206 288 371 536 701 (KG/HR) 93.4 130.6 168.3 243.1 318.0 LBS/HR206288371536701 (KG/HR)93.4130.6168.3243.1318.0 OPERATING WEIGHTLBS1,4081,4081,4082,0252,025 (KG)638.9638.9638.9918.6918.6 SHIPPING WEIGHTLBS1,1501,1501,1501,6501,650 (KG)521.6521.6521.6748.4748.4 RELIEF VALVE TYPICAL - 15 PSIG (103.4 KPA) QUANTITYA v a N i o l t a b l e(1) 13-213-08(1) 13-213-08(1) 13-213-08(1) 13-213-08 SIZEINCHES1-1/4 x 1-1/41-1/4 x 1-1/41-1/4 x 1-1/41-1/4 x 1-1/4 (CM)3.175 x 3.1753.175 x 3.1753.175 x 3.1753.175 x 3.175 CAPACITY-TOTALMBH1,2001,2001,2001,200 (KW)351.6351.6351.6351.6 RELIEF VALVE TYPICAL - 150 PSIG (1034.0 KPA) QUANTITY(1) 6021DC01(1) 6021DC01 SIZEINCHES1/2 x 3/41/2 x 3/41/2 x 3/41/2 x 3/41/2 x 3/4 (CM)1.27x1.9051.27x1.9051.27x1.9051.27x1.9051.27x1.905 CAPACITY-TOTALMBH925925925925925 (KW)271.0271.0271.0271.0271.0

* Output based on nominal 80% of input. Actual combustion efficiencies will be higher and fuel dependent.

Poser une question sur : Bryan Boilers DR250

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Bryan Boilers DR250

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Bryan Boilers DR250 manuel PDF

2 pages·280 KB·Chaudière·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…