FR
Bryan Boilers logo
Notice d'utilisation officielle

Bryan Boilers Broile System

2 pages·453 KB·Chaudière·PDF·EN
Bryan Boilers Broile System
Table des matières 5 sections Condensate Transfer Stations · Condensate rates from 1,500 PPH (3.0 GPM) · to 15,000 PPH (30.0 GPM) · Bryan Condensate Transfer Stations Features · … AfficherMasquer
Page 1 of the Bryan Boilers Broile System user manual — Bryan Condensate Transfer Stations Features
Page 1 · cliquer pour agrandir
Page 1

Form No. 8000-12

Bryan Boilers Broile System — Condensate Transfer Stations diagram (page 1)
Fig. 1 · Condensate Transfer Stations

Condensate Transfer Stations

Condensate rates from 1,500 PPH (3.0 GPM)

to 15,000 PPH (30.0 GPM)

Bryan Boilers Broile System — Condensate Transfer Stations diagram (page 1)
Fig. 2 · Condensate Transfer Stations
  • 8 to 50 gallon receivers
  • 6 to 60 GPM (3,000 to 30,000 PPH) pump capacities
  • 10 to 60 PSI discharge pressures

In most heating systems, condensate, and sometimes steam, is trapped out of heaters, kettles, hot presses, molds, absorbers, and other equipment and drained to a return unit having given up some of its heat in the process. If a trap malfunctions, the condensate can be passed to the return unit at a much higher temperature causing the return unit to fail. When using Bryan Condensate Transfer Stations as the return unit, this problem is overcome because they are designed to eliminate cavitation at higher temperatures. In addition, Bryan Condensate Transfer Stations are designed to handle the higher load placed on them during cold starts and are supplied with reliable pumps that are designed to handle hotter water and develop higher pressures at lower speeds. Bryan Condensate Transfer Stations are ideal for remote or non-accessible locations where unattended, dependable per- formance is essential.

handle water at up to 10 psi (0.68 bar) above the selected discharge pressure. Safety venting to the atmosphere is re- quired. Units will deliver hot water at temperatures up to 200ºF (93ºC) and will not vapor bind at 210ºF (98ºC). Electrical equipment is generally mounted at least 1 foot (0.305 m) above floor level for safety and to maintain pumping if flooding occurs. Bryan Condensate Transfer units are supplied with an internal pump that operates at 1750 rpm. Pumps, which are mounted vertically on top of the receiver, are leak proof and easy to maintain. Floats are set at the factory to provide about 2 inches (5.08 cm) of water level variation between start and stop. This insures frequent recycling and smaller condensate transfers at higher temperatures, thus improving overall efficiency of the boiler system. Settings for both float switches and mechanical alternators can be field adjusted. All units can be provided with optional pressure gauges for the pump discharge. An optional thermom- eter can be provided for the receiver. Electrical Motor sizes range from 1/4 hp to 2 hp and operate at 1750 rpm. Operating voltages are 115/230 volt single phase or 230/460 volt three phase. Enclosed motors are available as an option. Electrical options are available. Consult your Bryan represen- tative for more information.

Bryan Condensate Transfer Stations Features

Construction Bryan Condensate Transfer Stations can be supplied for either simplex or duplex operations. Simplex units can be converted to duplex operations in the field if an upgrade is required for receivers larger than eight gallons. Users can specify either cast iron or 3/16 inch (4.8 mm) steel receivers with receiver capacities ranging from 8 to 50 gallons (30 to 189 liters). A safety reserve is provided in these capacities to

(11/99) · Available Sizes

Page 2 of the Bryan Boilers Broile System user manual — Bryan Condensate Transfer Stations
Page 2 · cliquer pour agrandir
Page 2

Bryan Condensate Transfer Stations

Condensate RatePump Discharge Pressure PSIG (Bar)Minimum Pump GPM (M3/H)Motor HPReceiver CapacityPump Discharge Size NPTUnit Number Simplex G (L)Duplex G (L)Cast Iron ReceiverSteel Receiver 3.0 gpm (0.68 m3/h) or 1,500 PPH (680 kg/h)10 (0.68)6.0 (1.36)1/48 (30)15 (57)1B-6FB-6S 15 (1.02)6.0 (1.36)1/48 (30)15 (57)1B-6FB-6S 20 (1.36)6.0 (1.36)1/48 (30)15 (57)1B-6FB-6S 30 (2.04)6.0 (1.36)1/38 (30)15 (57)1B-9FB-9S 40 (2.72)6.0 (1.36)1/28 (30)15 (57)1-1/4B-37FB-37S 50 (3.40)6.0 (1.36)1/28 (30)15 (57)1-1/4B-37FB-37S 60 (4.08)6.0 (1.36)18 (30)15 (57)1-1/4B-39FB-39S 5.0 gpm (1.14 m3/h) or 2,500 PPH (1134 kg/h)10 (0.68)10.0 (2.27)1/48 (30)15 (57)1B-26FB-26S 15 (1.02)10.0 (2.27)1/38 (30)15 (57)1B-27FB-27S 20 (1.36) 30 (2.04) 40 (2.72)10.0 (2.27)1/38 (30)15 (57)1B-27FB-27S 10.0 (2.27)1/28 (30)15 (57)1B-29FB-29S 10.0 (2.27)3/48 (30)15 (57)1-1/4B-38FB-38S 50 (3.40) 60 (4.08)10.0 (2.27)3/48 (30)15 (57)1-1/4B-38FB-38S 10.0 (2.27)1-1/28 (30)15 (57)1-1/4B-61FB-61S 7.5 gpm (1.70 m3/h) or 3,750 PPH (1701 kg/h)10 (0.68) 15 (1.02)15.0 (3.41)1/315 (57)15 (57)1-1/4B-23FB-23S 15.0 (3.41)1/215 (57)15 (57)1-1/4B-25FB-25S 20 (1.36) 30 (2.04) 40 (2.72)15.0 (3.41)1/215 (57)15 (57)1-1/4B-25FB-25S 15.0 (3.41)3/415 (57)15 (57)1-1/4B-48FB-48S 15.0 (3.41)115 (57)15 (57)1-1/4B-50FB-50S 50 (3.40) 60 (4.08)15.0 (3.41)1-1/215 (57)15 (57)1-1/4B-62FB-62S 15.0 (3.41)215 (57)15 (57)1-1/4B-68FB-68S 10.0 gpm (2.27 m3/h) or 5,000 PPH (2268 kg/h)10 (0.68)20.0 (4.54)1/215 (57)15 (57)1-1/4B-2FB-2S 15 (1.02)20.0 (4.54)1/215 (57)15 (57)1-1/4B-2FB-2S 20 (1.36)20.0 (4.54)3/415 (57)15 (57)1-1/4B-3FB-3S 30 (2.04)20.0 (4.54)115 (57)15 (57)1-1/4B-59FB-59S 40 (2.72)20.0 (4.54)1-1/215 (57)15 (57)1-1/4B-62FB-62S 50 (3.40)20.0 (4.54)215 (57)15 (57)1-1/2B-75FB-75S 15.0 gpm (3.41 m3/h) or 7,500 PPH (3402 kg/h)10 (0.68)30.0 (6.81)3/423 (87)23 (87)1-1/4B-58FB-58S 15 (1.02)30.0 (6.81)3/423 (87)23 (87)1-1/4B-58FB-58S 20 (1.36) 30 (2.04)30.0 (6.81)3/423 (87)23 (87)1-1/4B-58FB-58S 30.0 (6.81)1-1/223 (87)23 (87)1-1/2B-74FB-74S 40 (2.72)30.0 (6.81)1-1/223 (87)23 (87)1-1/2B-74FB-74S 17.5 gpm (3.97 m3/h) or 8,750 PPH (3969 kg/h)10 (0.68)35.0 (7.95)3/423 (87)23 (87)1-1/2B-70FB-70S 15 (1.02)35.0 (7.95)123 (87)23 (87)1-1/2B-72FB-72S 20 (1.36) 30 (2.04)35.0 (7.95)123 (87)23 (87)1-1/2B-72FB-72S 35.0 (7.95)223 (87)23 (87)1-1/2B-78FB-78S 20.0 gpm (4.54 m3/h) or 10,000 PPH (4536 kg/h)10 (0.68)40.0 (9.08)3/435 (132)35 (132)1-1/2B-80FB-80S 15 (1.02)40.0 (9.08)135 (132)35 (132)1-1/2B-82FB-82S 20 (1.36)40.0 (9.08)135 (132)35 (132)1-1/2B-82FB-82S 30 (2.04)40.0 (9.08)235 (132)35 (132)1-1/2B-90FB-90S 25.0 gpm (5.68 m3/h) or 12,500 PPH (5670 kg/h)10 (0.68)50.0 (11.36)135 (132)35 (132)1-1/2B-87FB-87S 15 (1.02)50.0 (11.36)1-1/235 (132)35 (132)1-1/2B-89FB-89S 20 (1.36)50.0 (11.36)1-1/235 (132)35 (132)1-1/2B-89FB-89S 30.0 gpm (6.81 m3/h) or 15,000 PPH (8304 kg/h)10 (0.68)60.0 (13.63)1-1/250 (189)50 (189)1-1/2B-94FB-94S 15 (1.02)60.0 (13.63)250 (189)50 (189)1-1/2B-96FB-96S 20 (1.36)60.0 (13.63)250 (189)50 (189)1-1/2B-96FB-96S

Dimensions and specifications are subject to change without notice. Consult factory for certified dimensions.

  • P.O.Box 27, Peru, Indiana 46970-0027 U.S.A. Phone:765-473-6651
  • Internet:<a href="http://www.bryanboilers.com" rel="nofollow noopener" target="_blank">www.bryanboilers.com</a> Fax: 765-473-3074
  • E-mail: bryanboilers@<a href="http://iquest.net" rel="nofollow noopener" target="_blank">iquest.net</a>

Form No. 8000-12 ©1999 Bryan Steam Corp. Printed in USA

119-2310

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Bryan Boilers Broile System

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Bryan Boilers Broile System

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Bryan Boilers Broile System manuel PDF

2 pages·453 KB·Chaudière·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…