Bryan Boilers BE-210-WT4T7
Table des matières 6 sections (Rev. 11/06) Bryan Electric Indirect Water Heaters · 98,300 to 1,081,100 BTUH 30 to 330 KW · Model BE-210-WT4T7 · Note these features: · … AfficherMasquer
Page 1 of the Bryan Boilers BE-210-WT4T7 user manual — ® BOILERS
Page 1 · cliquer pour agrandir
Page 1

Form No. 4800

(Rev. 11/06) Bryan Electric Indirect Water Heaters

98,300 to 1,081,100 BTUH 30 to 330 KW

Bryan Boilers BE-210-WT4T7 — (Rev. 11/06) Bryan Electric Indirect Water Heaters diagram (page 1)
Fig. 1 · (Rev. 11/06) Bryan Electric Indirect Water Heaters

Model BE-210-WT4T7

Note these features:

Long life indirect heat exchanger and Incoloy sheathed electric heating elements All brass and copper fi nned-tube, high-effi ciency heat exchanger transfers heat from hot heater water to service water fl owing through exchanger. This results in both long electric heating element and long heat exchanger life with trouble-free operation. Special Incoloy alloy also substan- tially contributes to electric element life as compared to copper sheathing used in conventional electric heaters.

reactions such as oxidation or precipitation, the principal causes of corrosion and scale formation.

Condensation free The Bryan indirect heater operates at water temperatures that eliminate problems caused by moisture from sur- rounding air condensing as water, contributing to rusting and wet fl oors.

Quality construction Structural framework supports primary hot water vessel and power panel cabinet. Vessel and frame protected by a heavy 16 gauge steel, zinc-coated jacket attractively fi nished with two coats of enamel.

Economical scale-free boiler operation Scale-free operation means higher continuous heat trans- fer effi ciencies and reduction of maintenance costs. Con- ventional electric heaters generally require periodic shut- down for descaling of elements. Bryan’s indirect closed system heating means little or no scale build-up.

Applications Versatile for all typical commercial and industrial applica- tions, such as schools, apartments, hotels and motels, laundries, restaurants, hospitals, factories, etc. The heater may be used in conjunction with a storage tank (the tank and accessories may be supplied by Bryan as a packaged “Water-Pak”) or if the application permits, may be applied as a “tankless” installation. Available alternative to fossil fuel units when strict emission requirements must be met. BRYAN

Corrosion-resistant operation Corrosive and scale forming service water does not come into direct contact with steel heater parts and electric heating elements. Service water being heated circulates only through the copper indirect heat exchanger within a temperature range that eliminates or minimizes chemical

® BOILERS

Page 2 of the Bryan Boilers BE-210-WT4T7 user manual — Bryan Electric Indirect Water Heaters
Page 2 · cliquer pour agrandir
Page 2

Bryan Electric Indirect Water Heaters

PLAN VIEW LEFT END VIEW FRONT VIEW RIGHT END VIEW BRYAN ELECTRIC INDIRECT WATER HEATER RATINGS AND DIMENSIONS — in (cm) Model WeightInput KWOutput MBHRecovery Capacity (GPH)Boiler DimensionsPower Panel DimensionsBoiler Inlet & 460/575Coil Inlet & OutletOutletIHeat Exchanger Removal JElement Removal ClearanceShipping Clearance lbs. (kg) lengthwidthheight208-230/3/60380, BE-30-WT3098.340°-140°F 117A 48B 20C 32D 30E 36D 20E 24F & G 2H 1-1/22617K 26L 30840 BE-45-WT45147.4176(122) 48(51) 20(81) 32(76) 30(91) 36(51) 20(61) 24(5) 2(3.8) 2(66) 26(43) 17(66) 26(77) 30(373) 870 BE-60-WT60196.6235(122) 48(51) 20(81) 32(76) 30(91) 36(51) 20(61) 24(5) 2(5.08) 2(66) 26(43) 17(66) 26(77) 30(387) 900 BE-90-WT90294.8354(122) 48(51) 25(81) 40(76) 30(91) 36(51) 20(61) 30(5) 3(5.08) 2(66) 32(43) 20(66) 26(77) 30(400) 1070 BE-105-WT105344.0413(122) 48(71) 28(102) 40(76) 30(91) 48(51) 20(73) 30(8) 3(5.08) 2(79) 32(51) 20(66) 26(77) 30(476) 1115 BE-120-WT120393.1472(122) 48(71) 28(102) 40(76) 30(122) 48(51) 20(76) 30(8) 3(5.08) 2(79) 32(51) 20(66) 26(77) 30(496) 1170 BE-135-WT135441.0531(122) 48(71) 28(102) 40(76) 30(122) 66(76) 30(91) 36(8) 3(5.08) 2-1/2(79) 32(51) 20(66) 26(77) 30(521) 1370 BE-150-WT150491.4590(122) 48(71) 28(102) 40(76) 30(168) 66(76) 30(91) 36(8) 3(6.35) 2-1/2(79) 32(51) 20(66) 26(77) 30(610) 1390 BE-165-WT165539.1649(122) 48(71) 28(102) 40(76) 30(168) 66(76) 30(91) 36(8) 3(6.35) 2-1/2(79) 32(51) 20(66) 56(77) 30(618) 1420 BE-180-WT180589.7708(122) 48(71) 28(102) 40(76) 30(168) 66(76) 30(91) 36(8) 3(6.35) 2-1/2(79) 32(51) 20(142) 56(77) 30(632) 1470 BE-195-WT195637.2767(122) 48(71) 28(102) 40(76) 30(168) 66(76) 30(91) 48(8) 3(6.35) 2-1/2(79) 32(51) 20(142) 56(77) 30(654) 1800 BE-210-WT210688.0826(122) 76(71) 28(102) 40(76) N/A(168) N/A(76) 30(122) 48(8) 3(6.35) 2-1/2(79) 32(51) 20(142) 56(77) 55(801) 2600 BE-240-WT240789.5948(193) 76(71) 28(102) 40N/AN/A(76) 30(122) 48(8) 3(6.35) 2-1/2(79) 32(51) 20(142) 56(140) 55(1157) 2650 BE-270-WT270884.51,062(193) 76(71) 28(102) 40N/AN/A(76) 30(122) 66(8) 3(6.35) 2-1/2(79) 32(51) 20(142) 56(140) 55(1180) 2700 - BE-300-WT300982.01,180(193) 76(71) 28(102) 40N/AN/A(76) 30(168) 66(8) 3(6.35) 2-1/2(79) 32(51) 20(142) 56(140) 55(1202) 2750 BE-330-WT3301,081.11,298(193) 76(71) 28(102) 40N/AN/A(76) 30(168) 66(8) 3(6.35) 2-1/2(79) 32(51) 20(142) 56(140) 55(1224) 2800
Bryan Boilers BE-210-WT4T7 — Bryan Electric Indirect Water Heaters diagram (page 2)
Fig. 2 · Bryan Electric Indirect Water Heaters

Specifi cations subject to change without notice. Consult factory to consult on other boiler options.

Size range: 30-330 KW (98,300 to 1,081,100 BTUH) with the following voltage options: 30 KW to 120 KW — 240 volt/1 phase; 30 KW to 180 KW — 208 or 240 volts/3 phase; 30 KW to 330 — 460 or 480 volts/3 phase.

Equipment furnished: Combination boiler thermometer and pressure gauge, low water cutoff, operating temperature control, high limit tem- perature control, indirect heat exchanger, automatic boiler fi ll valve, boiler relief valve, boiler drain cock, magnetic contactors, pilot switch, power panel, insulated jacket and expansion tank. All equipment installed and wired. Expansion tank (shipped loose). A fused disconnect switch to be furnished by installer. When ordering: Please specify model, KW, type of system (tank or tankless). Initial and fi nal temperature water required, water fl ow rate (gal./ hr. or gal./min.), electrical characteristics (volts, phase, cycles), optional equipment or special requirements. Refer to BE Series brochure No. 3600 for further information.

  • Bryan Steam LLC — Leaders Since 1916 783 N. Chili Ave., Peru, Indiana 46970 U.S.A. Phone:765-473-6651
  • Internet:<a href="http://www.bryanboilers.com" rel="nofollow noopener" target="_blank">www.bryanboilers.com</a> Fax: 765-473-3074
  • E-mail:bryanboilers@<a href="http://iquest.net" rel="nofollow noopener" target="_blank">iquest.net</a>

Form No. 4800 ©2006 Bryan Steam LLC Printed in USA

116-8350

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Bryan Boilers BE-210-WT4T7

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Bryan Boilers BE-210-WT4T7

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Bryan Boilers BE-210-WT4T7 manuel PDF

2 pages·102 KB·Chauffe-eau·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…