FR
Zephyr logo
Notice d'utilisation officielle

Zephyr Tornado Mini

48 pages·553 KB·Ventilateur·PDF·ENDEITNLJA
Zephyr Tornado Mini
Table des matières 56 sections WWW.ZEPHYRONLINE.COM · Tornado Mini AK8400BS, AK8400BS290 · EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation · JAN21.0101 · … AfficherMasquer
Page 1 of the Zephyr Tornado Mini user manual — JAN21.0101
Page 1 · cliquer pour agrandir
Page 1
Zephyr Tornado Mini — WWW.ZEPHYRONLINE.COM diagram (page 1)
Fig. 1

WWW.ZEPHYRONLINE.COM

Tornado Mini AK8400BS, AK8400BS290

EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation

Zephyr Tornado Mini — WWW.ZEPHYRONLINE.COM diagram (page 1)
Fig. 2

JAN21.0101

Page 2 of the Zephyr Tornado Mini user manual — C O R E
Page 2 · cliquer pour agrandir
Page 2

C O R E

Page 3 of the Zephyr Tornado Mini user manual — C O R E
Page 3 · cliquer pour agrandir
Page 3
Page 3 of the Zephyr Tornado Mini user manual — C O R E
Page 4 of the Zephyr Tornado Mini user manual — WARNING
Page 4 · cliquer pour agrandir
Page 4

C O R E Safety Information

READ AND SAVE THESE INSTRUCTIONS

Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety

WARNING

messages.

a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

This is the Safety Alert Symbol. This symbol alerts you to potential hazards that can cause severe bodily injury or death. All safety messages will follow the Safety Alert Symbol and either

b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

the words “DANGER” “WARNING” or “CAUTION”

DANGER

CAUTION

result in severe injury or death.

For General Ventilating Use Only. Do Not Use To Exhaust

Hazardous Or Explosive Materials And Vapors. Take care when using cleaning agents or detergents. Suitable for use in

WARNING

household cooking area.

WARNING

injury, or death.

CAUTION

a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b) Always turn hood ON when cooking at high heat or when flambeing food. (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).

equipment damage.

c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

d) Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING

To reduce the risk of fire or electric shock, do not use this fan

with any solid-state control device.

General Safety

Page 5 of the Zephyr Tornado Mini user manual — CAUTION
Page 5 · cliquer pour agrandir
Page 5

ZEPHYRONLINE.COM Safety Information

READ AND SAVE THESE INSTRUCTIONS

WARNING

WARNING

a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

b) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

b) NEVER PICK UP A FLAMING PAN – You may be burned.

c) DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.

d) Use an extinguisher ONLY if:

1. You know you have a Class ABC extinguisher, and you already know how to operate it.

c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

2. The fire is small and contained in the area where it started.

d) Ducted fans must always be vented to the outdoors.

3. The fire department is being called.

e) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

4. You can fight the fire with your back to an exit

aBased on “Kitchen Firesafety Tips” published by NFPA.

WARNING

WARNING

Prop. 65 Warning for California Residents: This product may

contain chemicals known to the State of California to cause

cancer, birth defects, or other reproductive harm.

CAUTION

To reduce risk of fire and to properly exhaust air outside, do not vent exhaust air into spaces within walls, ceilings, attics,

crawl spaces, or garages.

Page 6 of the Zephyr Tornado Mini user manual — READ AND SAVE THESE INSTRUCTIONS
Page 6 · cliquer pour agrandir
Page 6

C O R E Safety Information

READ AND SAVE THESE INSTRUCTIONS

Ź Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.

Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.

Ź Observe all governing codes and ordinances.

Ź It is the customer’s responsibility to be aware of these below:

Ź To contact a qualified electrical installer.

Ź To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.

Ź If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Ź Do not ground to a gas pipe.

Ź Check with a qualified electrician if you are not sure the range hood is properly grounded.

Ź Do not have a fuse in the neutral or ground circuit.

Ź This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram on product.

Ź A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and install appropriate connector if necessary.

* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575

Operation · Electrical Requirements

Page 7 of the Zephyr Tornado Mini user manual — ZEPHYRONLINE.COM List of Materials
Page 7 · cliquer pour agrandir
Page 7

ZEPHYRONLINE.COM List of Materials

QuantityPart 1Power pack hood 1Aluminum mesh filter 2LumiLight LED, 6W (pre-installed) 1Single blower motor (pre-installed) 1Hardware package
Zephyr Tornado Mini — ZEPHYRONLINE.COM List of Materials diagram (page 7)
Fig. 3 · ZEPHYRONLINE.COM List of Materials

#6 x 1-1/2” (4)

Zephyr Tornado Mini — ZEPHYRONLINE.COM List of Materials diagram (page 7)
Fig. 4 · ZEPHYRONLINE.COM List of Materials
Zephyr Tornado Mini — ZEPHYRONLINE.COM List of Materials diagram (page 7)
Fig. 5 · ZEPHYRONLINE.COM List of Materials

Ducting, conduit and all installation tools Cable locking connector (if required by local codes) Stainless steel liner Recirculating kit (ZRC-8400A)

Parts Supplied · Parts Not Supplied

Page 8 of the Zephyr Tornado Mini user manual — Ducting Calculation Sheet
Page 8 · cliquer pour agrandir
Page 8

C O R E Installation Instructions

Ducting Calculation Sheet

Zephyr Tornado Mini — Ducting Calculation Sheet diagram (page 8)
Fig. 6 · Ducting Calculation Sheet
Duct piecesEquivalent number length x used =Total 3-1 / 4” x 10” Rect., straight1 Ft. x ( ) =Ft. 6”, 7”, 8”, 10” Round, straight1 Ft. x ( ) =Ft. 3-1 / 4” x 10” Rect. 900 elbow15 Ft. x ( ) =Ft. 3-1 / 4” x 10” Rect. 450 elbow9 Ft. x ( ) =Ft. 3-1 / 4” x 10” Rect. 900 flat elbow24 Ft. x ( ) =Ft. 7” to 6” or 8” to 7” Round tapered reducer25 Ft. x ( ) =Ft. 6”, 7“, 8” Round in-line damper15 Ft. x ( ) =Ft. 6”, 7”, 8”, 10” Round, 900 elbow15 Ft. x ( ) =Ft. 6”, 7”, 8”, 10” Round, 450 elbow9 Ft. x ( ) =Ft. Subtotal column 1 =Ft.
Duct piecesEquivalent number length x used =Total 3-1 / 4” x 10” Rect. to 6” round transition5 Ft. x ( ) =Ft. 3-1 / 4” x 10” Rect. to 6” round transition 900 elbow20 Ft. x ( ) =Ft. 6” round to 3-1 / 4” x 10” rect. transition1 Ft. x ( ) =Ft. 6” round to 3-1 / 4” x 10” rect. transition 900 elbow16 Ft. x ( ) =Ft. 7” round to 3 1/ 4” x 10” rect.8 Ft. x ( ) =Ft. transition 7” round to 3-1 / 4” x 10” rect. transition 900 elbow23 Ft. x ( ) =Ft. 3-1 / 4” x 10” Rect. wall cap with damper30 Ft. x ( ) =Ft. 6”, 7”, 8”, 10” Round, wall cap with damper30 Ft. x ( ) =Ft. 6”, 7”, 8”, 10” Round roof cap30 Ft. x ( ) =Ft. Subtotal column 2 = Subtotal column 1 = Total ductwork =Ft. Ft. Ft.

Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 150 equivalent feet.

Page 9 of the Zephyr Tornado Mini user manual — Mounting Height, Clearance, & Ducting
Page 9 · cliquer pour agrandir
Page 9

ZEPHYRONLINE.COM Installation Instructions

Mounting Height, Clearance, & Ducting

A minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air flow efficiency.

Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.

Also use the ducting calculation sheet (on page 8) to compute total available duct run when using elbows, transitions and caps.

ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size.

Min 20” - Max 36” (electric cooktops) Min 24” - Max 36” (gas cooktops)

If turns or transitions are required; install as far away from hood duct output and as far apart, between the two as possible.

Minimum mount height between range top to hood bottom should be no less than 20” for electric cook tops and 24” for gas cook tops.

Maximum mount height should be no higher than 36”.

It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose its performance and efficiency.

If available, also refer range manufacturer’s height clearance requirements and recommended hood mounting height above range. Always check your local codes for any differences.

For shipment and installation damages:

Ź Please fully inspect unit for damage before installation.

Ź If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or

replacement.

Ź If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.

Ź If the unit is damaged by the installer (if other than the customer), repair of replacement must be

made by arrangement between customer and installer.

36"

Page 10 of the Zephyr Tornado Mini user manual — Ducting Options
Page 10 · cliquer pour agrandir
Page 10

C O R E Installation Instructions

Ducting Options

Zephyr Tornado Mini — Ducting Options diagram (page 10)
Fig. 7 · Ducting Options

Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages.

All exhaust must be ducted to the outside, unless using the

Ź Use single wall rigid metal ductwork only.

Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct

Tape.

Zephyr Tornado Mini — Ducting Options diagram (page 10)
Fig. 8 · Ducting Options
Page 11 of the Zephyr Tornado Mini user manual — Bottom
Page 11 · cliquer pour agrandir
Page 11

ZEPHYRONLINE.COM Installation Instructions

‘‘†’‡ ‹Ů ƒ–‹‘•

Zephyr Tornado Mini — ‘‘†’‡ ‹Ů ƒ–‹‘• diagram (page 11)
Fig. 9
Zephyr Tornado Mini — ‘‘†’‡ ‹Ů ƒ–‹‘• diagram (page 11)
Fig. 10

Front

Top

Zephyr Tornado Mini — Front diagram (page 11)
Fig. 11 · Front
Zephyr Tornado Mini — Front diagram (page 11)
Fig. 12 · Front

Bottom

Side

Show 4 more labels / short text on this page
19-1/2” · 3-1/4” · 11” · 1-3/16” 9-11/16”
Page 12 of the Zephyr Tornado Mini user manual — FIG. A
Page 12 · cliquer pour agrandir
Page 12

C O R E Installation Instructions

Electrical Supply

Zephyr Tornado Mini — Electrical Supply diagram (page 12)
Fig. 13 · Electrical Supply

Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off

For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance.

Follow national electrical codes or prevailing local codes and ordinances.

This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/ ground. Please also refer to the Electrical Diagram labeled on product.

Grounding

GROUNDING INSTRUCTIONS

Zephyr Tornado Mini — GROUNDING INSTRUCTIONS diagram (page 12)
Fig. 14

This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.

FIG. A

Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded.

Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.

Position the electrical outlet within the space covered by or above the decorative canopy housing as space permits and as to not interfere with the round duct. Make sure the outlet is no further than 28” from the top of the hood body.

Page 13 of the Zephyr Tornado Mini user manual — FIG. E
Page 13 · cliquer pour agrandir
Page 13

ZEPHYRONLINE.COM Installation Instructions

Mounting the Hood

Zephyr Tornado Mini — Mounting the Hood diagram (page 13)
Fig. 15 · Mounting the Hood

At least two installers are required due to the weight

1. Install optional AK084xAS Stainless Steel Liner. Review manual included with liner for more details.

FIG. B

2. If no liner is used, cut out an opening in bottom of the cabinet by following the dimensions in FIG. B.
Zephyr Tornado Mini — FIG. B diagram (page 13)
Fig. 16
3. Remove aluminum mesh filter.
4. Lift Power Pack into opening and ensure locking clip has locked into position. (Locking clip is located on left side of Power Pack. FIG. C.
5. Fasten (2) #6 screws into the rear long side of Power Pack. If a liner is used, the screws will go through the Power Pack mounting holes, then the liner and the wood base. NOTE: Wood blocking may need to be added to cabinet base if additional support is needed. See FIG. D and FIG. E.

FIG C

FIG. C

Zephyr Tornado Mini — FIG C diagram (page 13)
Fig. 17
6. Remove 4 screws from Power Pack face plate. The face plate will drop down and hang by internal chains. Access to front long side of Power Pack is now available. Fasten (2) #6 screws into the front long side of Power Pack.
7. Re-install Power Pack face plate by (4) previously removed screws.

secure (2) #6 screws to mounting holes on each long side of Power Pack

8. Install duct work and seal with duct tape and install electrical.

FIG. D

Zephyr Tornado Mini — FIG. D diagram (page 13)
Fig. 18
9. Remove all packing materials before using Power Pack. Switch power on and check for leaks around duct tape. Install aluminum mesh filter.

FIG. E

Page 14 of the Zephyr Tornado Mini user manual — FIG. F
Page 14 · cliquer pour agrandir
Page 14

C O R E Installation Instructions

Ductless Recirculation

Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and re-circulated back within the home.

We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work, if possible. The hood is most effective and efficient as an exhaust hood. Only when the exhaust option is not possible should you recourse to converting the hood into a recirculating hood.

When converted to be a recirculating hood, a set of charcoal filters are required on top of its standard Metal Filter set. Order according to its part number below. The standard mesh filters are intended to capture residue from cooking, and the optional charcoal filters help to purify fumes exhausted from cooking for recirculation.

For detailed installation instructions, please refer to the manual included with the recirculating kit.

Recirculating Kit Hood Model Part Number Quantity to Order AK8400BS ZRC-8400A 1 AK8400BS290 ZRC-8400A 1

Zephyr Tornado Mini — Ductless Recirculation diagram (page 14)
Fig. 19 · Ductless Recirculation

Charcoal Filter Replacements Hood Model Part Number Quantity to Order AK8400BS Z0F-C084 1 AK8400BS290 Z0F-C084 1

Zephyr Tornado Mini — Ductless Recirculation diagram (page 14)
Fig. 20 · Ductless Recirculation

DO NOT WASH CHARCOAL FILTERS. Charcoal filters may need to be changed more often depending on cooking habits.

Installing Charcoal Filter (FIG. F):

Zephyr Tornado Mini — Ductless Recirculation diagram (page 14)
Fig. 21 · Ductless Recirculation
1. Place charcoal filter on top of back side of aluminum mesh filter.
2. Secure charcoal filter by 4 C clips from ZRC-8400A recirculation kit, 2 C clips for each elongated side of charcoal filter.

FIG. F

Page 15 of the Zephyr Tornado Mini user manual — LIGHTS OFF/DIM/BRIGHT
Page 15 · cliquer pour agrandir
Page 15

ZEPHYRONLINE.COM Features & Controls

Slide Controls

Blower On/Oے‡‡†‡Ž‡ –‹‘ 1 ‹‰Š–•Űħ‹ħ”‹‰Š– 2

0 I II III

BLOWER ON/OFF/SPEED SELECTION

ř‹•‘Űĕ ‹•Ž‘™•’‡‡†ĕ ‹•‡†‹—•’‡‡†ƒ† ‹•Š‹‰Š•’‡‡†Ę

LIGHTS OFF/DIM/BRIGHT

ř‹•‘Űĕ ‹•†‹ĕƒ† ‹•„”‹‰Š–Ę

Page 16 of the Zephyr Tornado Mini user manual — C O R E
Page 16 · cliquer pour agrandir
Page 16

C O R E

Maintenance

Hood & Filter Cleaning

Ź Do not use corrosive detergents, abrasive detergents or oven cleaners.

Ź Do not use any product containing chlorine bleach or any product containing chloride.

Ź Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface.

Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain. To remove heavier grease build up use a liquid degreaser detergent.

After cleaning use a non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth or micro fiber cloth and buff in the direction of the stainless steel grain.

The aluminum mesh filters installed by the factory are intended to filter out residue and grease from cooking. They need not be replaced on a regular basis but are required to be kept clean.

Remove and clean by hand or in dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate detergents, or as a result of local water conditions - but this will not affect filter performance. This discoloration is not covered by the warranty. Spray degreasing detergent and leave to soak if heavily soiled.

Dry filters and re-install before using hood.

Surface Maintenance · Cleaning Stainless Steel · Aluminum Mesh Filters

Page 17 of the Zephyr Tornado Mini user manual — FIG. H
Page 17 · cliquer pour agrandir
Page 17

ZEPHYRONLINE.COM Maintenance

Zephyr Tornado Mini — ZEPHYRONLINE.COM Maintenance diagram (page 17)
Fig. 22 · ZEPHYRONLINE.COM Maintenance
1. Place back of filter into channel on left side of Power Pack.
2. Pull filter handle towards left side of Power Pack.

FIG. G

Replacing Aluminum Mesh Filters

Zephyr Tornado Mini — FIG. G diagram (page 17)
Fig. 23

Hood Model Part Number Qty. to Order AK8400BS 50200054 1 AK8400BS290 50200054 1

To order parts, visit us online at http://store.zephyronline.com

LumiLight LED

In the unlikely event that your LumiLight LED fails, please contact Zephyr to order replacement parts. See the list of parts and accessories page for part numbers and contact information.

Zephyr Tornado Mini — LumiLight LED diagram (page 17)
Fig. 24 · LumiLight LED

LED Removal (FIG. H):

1. Remove aluminum mesh filter.
2. Remove bottom panel by two screws.
3. Disconnect LED light quick connector.
4. Push in the two side clips on the ends of the LED light.
5. Push LED light through the light panel opening.

FIG. H

Page 18 of the Zephyr Tornado Mini user manual — C O R E Wiring Diagram
Page 18 · cliquer pour agrandir
Page 18

C O R E Wiring Diagram

Zephyr Tornado Mini — C O R E Wiring Diagram diagram (page 18)
Fig. 25 · C O R E Wiring Diagram
Page 19 of the Zephyr Tornado Mini user manual — ZEPHYRONLINE.COM Troubleshooting
Page 19 · cliquer pour agrandir
Page 19

ZEPHYRONLINE.COM Troubleshooting

Possible Problem Possible Cause Solutions

After installation, the unit doesn’t work.

The power source is not turned ON.

Make sure the circuit breaker and the unit’s power is ON. The power line and the cable locking connector is not connecting properly.

Check the power connection with the unit is connected properly.

The switch board or control board wirings are disconnected.

Make sure the wirings at the switch board and control board are connected properly. The switch board or control board is defective.

Change the switch board or control board. The wires on control board are loose.

Make sure the wires on the control board are connected properly. Light works, but blower is not turning.

The thermally protected system detects if the blower is too hot to operate and shuts the blower down.

The blower will function properly after the thermally protected system cool down.

Damaged capacitor. Change the capacitor.

The blower is defective, possibly seized.

Change the blower.

The unit is vibrating. The blower is not secured in place. Tighten the blower in place. Damaged blower wheel. Replace the blower. The hood is not secured in place. Check the installation of the hood.

The unit is whistling. A filter is not in the correct position.

Adjust the filters until the whistling stops.

Check the duct pipe connections to be sure all connections are sealed properly. The blower is working, but the LumiLight LEDs are not.

The duct pipe connections are not sealed or connected properly.

The LumiLight LED connector is disconnected.

Connect the LumiLight LED connector.

Defective LumiLight LED. Change the LumiLight LED.

Change the switch board or control board. LumiLight LEDs flicker when changing speed levels.

The switch board or control board is defective.

N/A This is a normal operation and the hood is working correctly.

Page 20 of the Zephyr Tornado Mini user manual — C O R E Troubleshooting
Page 20 · cliquer pour agrandir
Page 20

C O R E Troubleshooting

Possible Problem Possible Cause Solutions

The hood is not venting out properly.

Using the wrong size of ducting. Change the ducting to the correct size.

The hood might be hanging to high from the cook top.

Adjust the distance between the cook top and the bottom of the hood within 20” (electric cook tops) or 24” (gas cook tops) and 36” range. The wind from the opened windows or opened doors in the surrounding area are affecting the ventilation of the hood.

Close all the windows and doors to eliminate the outside wind flow.

Remove all the blocking from the duct work or duct opening. Filter is vibrating. Filter is loose. Adjust or change the filter.

Blockage in the duct opening or ductwork.

Spring clip is broken on the filter. Change the spring clip.

Page 21 of the Zephyr Tornado Mini user manual — ZEPHYRONLINE.COM List of Parts & Accessories
Page 21 · cliquer pour agrandir
Page 21

ZEPHYRONLINE.COM List of Parts & Accessories

Description Part Number Replacement Parts LumiLight LED, 6W Z0B0049 Aluminum Mesh Filter 50200054

Optional Accessories Recirculating Kit ZRC-8400A Replacement Charcoal Filter Z0F-C084 Liner, 30” AK0840AS Liner, 36” AK0846AS

To order parts, visit us online at http://store.zephyronline.com

Page 22 of the Zephyr Tornado Mini user manual — C O R E Notes
Page 22 · cliquer pour agrandir
Page 22

C O R E Notes

Page 23 of the Zephyr Tornado Mini user manual — MAY20.0401
Page 23 · cliquer pour agrandir
Page 23

ZEPHYRONLINE.COM Limited Warranty

Zephyr Tornado Mini — ZEPHYRONLINE.COM Limited Warranty diagram (page 23)
Fig. 26 · ZEPHYRONLINE.COM Limited Warranty

Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:

Three Year Limited Warranty for Parts: For three years from the date of your original purchase of the Products, we will provide, free of charge, Products or parts (including LED light bulbs, if applicable) to replace those that failed due to manufacturing defects subject to the exclusions and limitations below. We may choose, in our sole discretion, to repair or replace parts before we elect to replace the Products.

One Year Limited Warranty for Labor: For one year from the date of your original purchase of the Products, we will provide, free of charge, the labor cost associated with repairing the Products or parts to replace those that failed due to manufacturing defects subject to the exclusions and limitations below. After the first year from the date of your original purchase, you are responsible for all labor costs associated with this warranty.

Warranty Exclusions: This warranty covers only repair or replacement, at our option, of defective Products or parts and does not cover any other costs related to the Products including but not limited to: (a) normal maintenance and service required for the Products and consumable parts such as fluorescent, incandescent or halogen light bulbs, mesh and char- coal filters and fuses; (b) any Products or parts which have been subject to freight damage, misuse, negligence, accident, faulty installation or installation contrary to recommended installation instructions, improper maintenance or repair (other than by us); (c) commercial or government use of the Products or use otherwise inconsistent with its intended purpose; (d) natural wear of the finish of the Products or wear caused by improper maintenance, use of corrosive and abrasive cleaning products, pads, and oven cleaner products; (e) chips, dents or cracks caused by abuse or misuse of the Products; (f) service trips to your home to teach you how to use the Products; (g) damage to the Products caused by accident, fire, floods, acts of God; or (h) Custom installations or alterations that impact serviceability of the Products. If you are outside our service area, additional charges may apply for shipping costs for warranty repair at our designated service locations and for the travel cost to have a service technician come to your home to repair, remove or reinstall the Products. After the first year from the date of your original purchase, you are also responsible for all labor costs associated with this warranty. All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service.

Limitations of Warranty. OUR OBLIGATION TO REPAIR OR REPLACE, AT OUR OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. WE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS. THE EXPRESS WARRANTIES IN THE PRECEDING SECTION ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. WE HEREBY DISCLAIM AND EXCLUDE ALL OTHER EXPRESS WARRANTIES FOR THE PRODUCTS, AND DISCLAIM AND EXCLUDE ALL WARRANTIES IMPLIED BY LAW, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states or provinces do not allow limitations on the duration of an implied warranty or the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. To the extent that applicable law prohibits the exclusion of implied warranties, the duration of any applicable implied warranty is limited to the same three-year and one-year periods described above if permitted by applicable law. Any oral or written description of the Products is for the sole purpose of identifying the Products and shall not be construed as an express warranty. Prior to using, implementing or permitting use of the Products, you shall determine the suitability of the Products for the intended use, and you shall assume all risk and liability whatsoever in connection with such determination. We reserve the right to use functionally equivalent refurbished or reconditioned parts or Products as warranty replacements or as part of warranty service. This warranty is not transferable from the original purchaser and only applies to the consumer residence where the Product was originally installed located in the United States and Canada. This warranty is not extended to resellers.

To Obtain Service Under Limited Warranty: To qualify for warranty service, you must: (a) notify us at the address or telephone number stated below within 60 days of the discovery of the defect; (b) give the model number and serial number; and (c) describe the nature of any defect in the Product or part. At the time of the request for warranty service, you must present evidence of your proof of purchase and proof of the original purchase date. If we determine that the warranty exclusions listed above apply or if you fail to provide the necessary documentation to obtain service, you will be responsible for all shipping, travel, labor and other costs related to the services. This warranty is not extended or restarted upon warranty repair or replacements.

Please check our website for any additional Product information, www.zephyronline.com

Zephyr Ventilation Service Department, 2277 Harbor Bay Parkway, Alameda, CA 94502 1-888-880-8368

MAY20.0401

Page 24 of the Zephyr Tornado Mini user manual — IT’S IMPORTANT
Page 24 · cliquer pour agrandir
Page 24

C O R E Product Registration

Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration

IT’S IMPORTANT

Prompt registration helps in more ways than one.

Ensures warranty coverage should you need service.

Ownership verification for insurance purposes.

Notification of product changes or recalls.

Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.8368

Page 25 of the Zephyr Tornado Mini user manual — JAN21.0101
Page 25 · cliquer pour agrandir
Page 25

WWW.ZEPHYRONLINE.COM

Tornado Mini AK8400BS, AK8400BS290

EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation

Zephyr Tornado Mini — WWW.ZEPHYRONLINE.COM diagram (page 25)
Fig. 27

JAN21.0101

Page 26 of the Zephyr Tornado Mini user manual — C O R E
Page 26 · cliquer pour agrandir
Page 26

C O R E

I N S É R E R

2 Tornado Mini Guide d’utilisation, d’entretien et d’installation

Page 27 of the Zephyr Tornado Mini user manual — I N S É R E R
Page 27 · cliquer pour agrandir
Page 27
Page 27 of the Zephyr Tornado Mini user manual — I N S É R E R
Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
The hood is not venting out properly.Using the wrong size of ducting.Change the ducting to the correct size. p.20
The hood is not venting out properly.The hood might be hanging to high from the cook top.Adjust the distance between the cook top and the bottom of the hood within 20” (electric cook tops) or 24” (gas cook tops) and 36” range. p.20
The hood is not venting out properly.The wind from the opened windows or opened doors in the surrounding area are afefcting the ventilation of the hood.Close all the windows and doors to eliminate the outside wind flow. p.20
The hood is not venting out properly.Blockage in the duct opening or ductwork.Remove all the blocking from the duct work or duct opening. p.20
Filter is vibrating.Filter is loose.Adjust or change the filter. p.20
Filter is vibrating.Spring clip is broken on the filter.Change the spring clip. p.20

Poser une question sur : Zephyr Tornado Mini

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Zephyr Tornado Mini

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Zephyr Tornado Mini manuel PDF

48 pages·553 KB·Ventilateur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…