TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- JURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufac- turer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the ser- vice disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. 4. Sufficient air is needed for proper combustion and exhaust- ing of gases through the flue (chimney) of fuel burning equip- ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code au- thorities. 5. This product may have sharp edges. Be careful to avoid cuts and abrasions during installation and cleaning. 6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 7. Ducted fans must always be vented to the outdoors. 8. Use only metal ductwork. 9. Do not use this fan with any solid-state speed control device. 10. As an alternative, this product may be installed with the UL- approved cord kit designated for the product, following in- structions packed with the cord kit. 11. This unit must be grounded.
already know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.
1. For indoor use only. 2. For general ventilating use only. Do not use to exhaust haz- ardous or explosive materials and vapors. 3. To avoid motor bearing damage and noisy and/or unbal- anced impeller, keep drywall spray, construction dust, etc., off power unit. 4. Do not use over cooking equipment greater than 60,000 BTU/hr. as the blower motor will shut down intermittantly. 5. Your hood motor has a thermal overload which will automati- cally shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced. 6. The top of the hood MUST NOT BE LESS than 24” and at a maximum of 30” above cooktop for best capture of cooking impurities. 7. This hood is not intended to be used as a shelf. 8. Please read specification label on product for further infor- mation and requirements.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: 1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ig- nite. Heat oils slowly on low or medium settings. 2. Always turn hood ON when cooking at high heat or when cooking flaming foods (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). 3. Clean ventilating fans frequently. Grease should not be al- lowed to accumulate on fan or filter. 4. Use proper pan size. Always use cookware appropriate for the size of the surface element.
Purchase a set of (2) non-ducted filters for 30” wide hoods (Model BPPF30) & 36” wide hoods (Model BPPF36) or a set of (3) non-ducted filters for 42” wide hoods (Model BPPF42) from your local distributor or retailer and attach them to the aluminum mesh filters.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:* 1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
with the homeowner. Homeowner: Cleaning, Maintenance and
Operating instructions on page 2.


2 Use the proper diagram below, for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole.


17 5/8" (42" hood) 14 5/8" (36" hood) 14 5/8" (36" hood) 11 5/8" (30" hood) 11 5/8" (30" hood)
The Range Hood Control Board contains a Fuse to protect the controls from power surges. If the fuse has opened (blown), the green fan setting or light setting indicators will not operate properly when the fan or light buttons are pressed, and the fan and lights will not turn on.
ELECTRICAL ACCESS HOLE (in cabinet bottom) WOOD SHIMS (recessed-bottom
A new fuse can be purchased at your local electronic supply store. Use an 8A, 120V, 5 mm diameter, 20 mm long, fast-acting, cartridge-type fuse.
To replace the fuse: 1. Disconnect power at service entrance. 2. Remove filters and bottom pan. 3. Remove and inspect fuse. If it is not open (blown), additional diagnostics are needed.


ROOF CAP 3¼" X 10" or 7" ROUND DUCT (For vertical
17 5/8" (42" hood) 17 5/8" (42" hood) 14 5/8" (36" hood) 14 5/8" (36" hood) 11 5/8" (30" hood) 11 5/8" (30" hood)

17 5/8" (42" hood) 17 5/8" (42" hood) 14 5/8" (36" hood) 14 5/8" (36" hood) 11 5/8" (30" hood) 11 5/8" (30" hood)
6 7/8" 107/8"
x 10” or 7” Round), or horizontally (3¼” x 10” only). For vertical or horizontal discharge, run ductwork between the hood location and a roof cap or wall cap. For best results, use a minimum number of transitions and elbows.
* Note the extra wood shim and mounting screw near the cabinet front, on the cabinet center line.

3 Remove parts bag from inside the foam packaging end cap.
4 Remove all protective polyfilm from the hood (stainless steel hoods only).
ç
NON-DUCT
ALUMINUM
PLATE
5 Remove the Aluminum Filters from the hood.
NON-DUCT
PLATE
ç
SLOT
6 Remove 6 Screws holding Bottom Pan to hood. Set bot- tom pan and screws aside.
PLENUM
9 NON-DUCTED INSTALLATION ONLY: Remove 2 Screws holding Non-Duct Plate to Non-Duct Plenum and remove plate.
DAMPER / DUCT CONNECTOR
7 Remove 2 Screws holding Damper / Duct Connector to hood. Remove damper/duct connector from inside the hood.
FOR DUCTED INSTALLATIONS - Skip to Step 12.
PLATE
10 NON-DUCTED INSTALLATION ONLY: Insert short end of Non-Duct Plate into Non-Duct Plenum Slot. Attach with 2 Screws removed in Step 9.
DIVERTER
11 NON-DUCTED INSTALLATION ONLY:
Purchase a set of (2) non-ducted filters for 30” wide hoods (Model BPPF30) & 36” wide hoods (Model BPPF36) or a set of (3) non-ducted filters for 42” wide hoods (Model BPPF42) from your local distributor or retailer. Attach the non-ducted filters to the aluminum mesh filters following instructions packed with the non-ducted filters.
8 NON-DUCTED INSTALLATION ONLY: From parts bag: Attach Non-Duct Diverter to Air Box with 2 Screws and 2 Washers.
FOR NON-DUCTED INSTALLATIONS - Skip to “INSTALL THE HOOD”.



12 DUCTED INSTALLATION ONLY: Remove 3¼” x 10 vertical, 3¼” x 10” horizontal, or 7-inch round knockout plate(s) as appropriate for your ducting method.

14 Remove Electrical Wiring Box Cover from inside of hood and appropriate Electrical Power Cable Knockout from top or back of hood.
15 Run House Power Cable between service panel and hood location. Attach power cable to hood using appropriate clamp.
13 DUCTED INSTALLATION ONLY: Attach 3¼” x 10” Damper/Duct Connector (if using 3¼” x 10” duct) or 7” Round Duct Plate (if using 7-inch round duct) over the knockout opening.
16 Hang hood from (4) mounting screws driven part-way into cabinet locations (shown in illustrations under “PREPARE HOOD LOCATION”). Mounting screws are included in parts bag. Slide hood back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood. Tighten screws securely. Add 5th mounting screw in center hole in hood and tighten securely.
To accomodate off-center ductwork, the 3¼” x 10” damper/duct connector can be installed up to ½” on either side of the hood center and the 7” round duct plate can be installed up to ½” on either side of the hood center.
17 DUCTED INSTALLATION ONLY: Connect ductwork to hood and use duct tape to make joints secure and air-tight. Make sure the damper / duct connector enters the ductwork and that the damper opens and closes freely.
Install the 3¼” x 10” Damper/Duct Connector with the Damper Flap Pivot nearest the Top/Back Edge of Hood.


To change the depth of bulb sockets: - Remove bottom pan (See Step 6). - Remove 2 Light Panel Screws and Light Panel. Set screws aside. - Loosen 2 Screws holding Lamp Socket Bracket to Light Panel. - Adjust socket/bracket to desired depth. - Re-tighten screws securely. - Re-attach light panel and bottom pan.
18 Connect House Power Cable to range hood wiring - BLACK to BLACK, WHITE to WHITE, and GREEN or BARE WIRE to Ground Screw. Replace electrical wiring box cover.
19 Re-attach Bottom Pan with 6 Screws removed in Step 6.
21 DUCTED INSTALLATION ONLY: Re-install aluminum filters removed in Step 5.
NON-DUCTED INSTALLATION ONLY: Install aluminum filters and non-ducted filters - purchased and assembled in Step 11.

One Year Limited Warranty Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711 Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario Canada L5T 1H9 www.broan.ca 877-896-1119 Rev. 08/2007
20 Install (4) Halogen Bulbs (included with hood). Use 120 V, 50 W, shielded halogen bulbs - MR16 with GU10 base.
Align pins on bulb with large diameter opening on socket, then push bulb in towards hood and rotate clockwise until firmly seated.
The position of the bulb socket (depth) is adjustable and may require adjustment when: a) certain brands of bulbs are difficult to install. b) the bulb protrudes too far below the light panel.

KEY NO. PART NO. DESCRIPTION 1 97017727 7” Round Duct Plate (includes mounting hardware) 2 97018245 User Interface Assembly White (includes interface, nameplate, mounting hardware) 97018246 User Interface Assembly Black (includes interface, nameplate, mounting hardware) 97018247 User Interface Assembly Bisque (includes interface, nameplate, mounting hardware) 3 99528248 Nameplate, White 99528249 Nameplate, Black 99528250 Nameplate, Bisque 4 97018251 Capacitor Kit (includes wire nuts, mounting screw) 5 97018225 Light Panel RH White (includes mounting hardware) 97018226 Light Panel RH Black (includes mounting hardware) 97018227 Light Panel RH Stainless (includes mounting hardware) 97018228 Light Panel RH Bisque (includes mounting hardware) 6 97018202 Filter Kit for 30”” (2 per bag) 97018203 Filter Kit for 36” (2 per bag) 97018204 Filter Kit for 42” (3 per bag) 7 97018220 Blower Wheel (includes mounting nut) 8 97018222 Motor Kit (includes motor, isolators, mounting hardware) 9 97017728 Damper / Duct Connector (includes mounting hardware) 10 97018229 Light Panel LH White (includes mounting hardware) 97018230 Light Panel LH Black (includes mounting hardware) 97018231 Light Panel LH Stainless (includes mounting hardware) 97018232 Light Panel LH Bisque (includes mounting hardware) 11 97017731 Lamp Socket (includes lamp socket, wire nuts, mounting screws) 12 97018233 Lamp Socket Bracket 13 97018236 Bottom Pan 30” (includes mounting hardware) 97018237 Bottom Pan 36” (includes mounting hardware) 97018238 Bottom Pan 42” (includes mounting hardware) 14 97018242 Non-duct Plenum (includes gasket & mounting hardware) 15 97018243 Non-duct Diverter (includes mounting hardware) 16 97018244 Non-duct Plate (includes mounting hardware) 17 97018254 Circuit Board Not Shown 97018224 Parts Bag Not Shown 99010353 Non-Duct Filter Kit for 30”” (2 charcoal filters and 8 filter clips) 99010354 Non-Duct Filter Kit for 36” (2 charcoal filters and 8 filter clips) 99010360 Non-Duct Filter Kit for 42” (3 charcoal filters and 12 filter clips) Not Shown 99526707 Suction Cup Tool Not Shown 97018252 Heat Sensor Not Shown 97018253 Fuse Not Shown 97018255 Ribbon Cable Not Shown V05921 50W Halogen GU10 Bulb
Order replacement parts by PART NO. - not by KEY NO.
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.