MODELS MP100, MP140 & MP200 MULTI-PORT IN-LINE FANS

READ AND SAVE THESE INSTRUCTIONS

WARNING WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOW- ING:

Protection Association (NFPA), and the American Soci- ety for Heating, Refrigeration and Air Conditioning Engi- neers (ASHRAE), and the local code authorities.

1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed below the warranty.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
7. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
3. If ventilator is installed in an unconditioned space (such as an attic): Surround the ventilator with thermal insulation - to minimize possible condensation.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fueling equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire
4. Please read specification label on product for further information and requirements.

PLAN THE INSTALLATION

Adequate ventilation requires that both intermittent and continuous contamination be controlled.

RECOMMENDED VENTILATOR SIZING

DWELLING SIZE RANGE (Sq. Ftg.) (include finished basement area) MODEL.50 AC/HR*.35 AC/HR*.30 AC/HR* MP100 MP140 MP2001500 2100 30002140 3000 42852500 3500 5000

Intermittent ventilation must be provided in the bathroom and kitchen. The bathroom requires 8 air changes per hour. (Multiply bathroom sq. footage by 1.1 for proper fan sizing). The kitchen requires a minimum of 150 CFM capacity (71 l/s) when a ducted range hood is used. If a kitchen fan is used, determine fan capacity by multiplying the room's sq. footage by 2. All are run intermittently to control pollution at the source.

*AC/HR = Air Changes per Hour. Based on 8' ceilings.

Square Feet x .093 = Square Meters

Continuous ventilation, while the house is occupied, pro- vides the flow of fresh air for good indoor air quality.

This ventilator is intended for continuous operation, supply- ing fresh air to the entire house.

Page 2 of the Broan MP100 user manual — FRESH AIR INLETS
Page 2 · cliquer pour agrandir
Page 2

PLAN THE INSTALLATION LOCATION OF DIFFUSERS & INLETS

Broan MP100 — PLAN THE INSTALLATION LOCATION OF DIFFUSERS & INLETS diagram (page 2)
Fig. 2

FRESH AIR INLET

STALE AIR VENTILATOR

SINGLE-STORY HOME

Broan MP100 — FRESH AIR INLET diagram (page 2)
Fig. 3

FRESH AIR INLETS

DIFFUSER

FRESH AIR

DUCTED KITCHEN RANGE HOOD

DIFFUSER DIFFUSER

DUCTED

BATH FAN

AIR FLOW IN TYPICAL INSTALLATION

VENTILATOR

The ventilator exhausts stale air. There are normally suffi- cient natural intake openings into a dwelling to admit fresh outside air to be drawn in to replace the stale air. For better control, fresh air inlets may be used.

FRESH AIR INLETS

The ventilator should be centrally located to keep ductwork as short as possible. Locations for the ventilator include: joists in an attic space or the basement, or a wall away from the living areas.

TWO-STORY HOME

FRESH AIR INLETS

Broan MP100 — TWO-STORY HOME diagram (page 2)
Fig. 4

EXHAUST DIFFUSERS (Available separately)

DIFFUSER

Exhaust diffusers regulate the flow of fresh air drawn through the house.

SECOND FLOOR

Broan MP100 — SECOND FLOOR diagram (page 2)
Fig. 5

COOKING AREA

DIFFUSER

Do not install above or inside

Exhaust diffusers should be mounted in the ceil- ings or high on the wall.

DUCTED

BATH FAN

45o 45o

For best performance, ex- haust diffusers should be mounted in a central loca- tion. An exhaust diffuser should not be installed near a cooking area. (see figure)

FRESH AIR INLETS

Broan MP100 — FRESH AIR INLETS diagram (page 2)
Fig. 6

DUCTED KITCHEN RANGE HOOD

FRESH AIR INLETS (Available separately)

DIFFUSER DIFFUSER

For best control of fresh air in a room, install a fresh air inlet.

The number of inlet vents depends on the floor plan. Consider the rooms/areas through which fresh air should flow toward the exhaust diffuser(s).

DUCTED

FIRST FLOOR

BATH FAN

Vents should be located in outside walls, preferably near the ceiling and approximately the same distance from a diffuser. Vents should be separated from diffusers far enough to allow fresh air to mix with room air before being exhausted.

FRESH AIR INLETS

Show 4 more labels / short text on this page
this area · Cooking · Floor · Equipment
Page 3 of the Broan MP100 user manual — 120 VAC LINE IN
Page 3 · cliquer pour agrandir
Page 3

INSTALL FRESH AIR INLETS

CONNECT DUCTWORK

1. Mount all fresh air inlets in chosen locations during rough-in construction. Follow directions packed with inlets.

FROM DIFFUSERS

DUCT TAPE OR CLAMP

6" ROUND INSULATED FLEXIBLE DUCT (OUTLET)

4" ROUND INSULATED FLEXIBLE DUCT

MOUNT THE VENTILATOR

CEILING JOISTS

FROM DIFFUSERS TO ROOF OR WALL CAP

1. Run 4" insulated, flexible ductwork from ventilator inlet to diffuser location(s) and 6" insulated flexible ductwork from ventilator outlet to roof or wall cap.Outlet side is marked with a label.
2. To minimize condensation inside of ductwork in the attic, cover ductwork with additional insulation. Also, avoid forming condensation traps in the ductwork runs.

FRAMING

3. Seal ductwork to ventilator and roof or wall cap with duct tape or clamp (available separately).
4. If some ventilator inlets will not be used: Place the inlet cover(s) (provided) over the unused inlet(s) and tape them in place.

OR

WIRE THE VENTILATOR WARNING: DISCONNECT POWER AT SERVICE ENTRANCE AND LOCK OUT SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.

CEILING JOISTS

GROUND WIRE

Broan MP100 — CEILING JOISTS diagram (page 3)
Fig. 7

WIRING ADAPTER

PLATE

BLACK

FRAMING

WHITE

BLACK GROUND (Green or Bare Wires)

ON/OFF SWITCH

1. Add framing to ceiling joists as shown.
2. Set ventilator in place and screw to framing with screws provided. Ventilator may also be hung from joists or rafters with hanging straps (available separately).

120 VAC LINE IN

BLACK

Use an ON/OFF switch to control the in-line ventilator. Accessory timers and humidity controls are also available. 1. Remove the wiring adapter plate.

2. Attach power cable to wiring adapter plate using U.L./ CSA approved connector.
3. Connect black to black, white to white, and green or bare wire to green ground screw.
4. Replace wiring adapter plate. Make sure tab on housing slides through slot in plate.
Page 4 of the Broan MP100 user manual — 99041951J
Page 4 · cliquer pour agrandir
Page 4

INSTALL EXHAUST DIFFUSERS

USE AND CARE

4" ROUND INSULATED FLEXIBLE DUCT

TO VENTILATOR

CLEANING

DUCT TAPE OR CLAMP

A continuously operating in-line ventilator needs to be cleaned once a year to assure proper performance.

Remove cover and carefully vacuum blower and inside of hous- ing. Be careful not to bend or otherwise damage blower wheel.

CEILING DRYWALL

Diffusers and intake vents can be vacuumed and/or wiped clean with a damp cloth.

DIFFUSER

Follow instructions packed with diffuser(s). General instructions:

MOTOR LUBRICATION

The motor is permanently lubricated. Do not oil or disassemble motor.

1. Cut hole(s) in ceiling drywall and install diffuser(s).
2. Connect insulated ductwork to diffuser(s) and use duct tape or clamp (available separately) to seal connection(s).
3. Rotate center of diffuser(s) counterclockwise to fully open for maximum air flow. Reduce air flow by rotating center of diffuser(s) clockwise to desired opening. A balancing damper (available separately) can be used to adjust airflow.
Broan MP100 — MOTOR LUBRICATION diagram (page 4)
Fig. 8

SERVICE PARTS Models MP100, MP140 & MP200

KEY NO.PART NO.DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 ** ** **99150591 97011410 98005512 99150471 97008575 99260477 99420470 98005513 99400035 97011394 97011395 97011396 97011361 97011362 97011363 99100412 97011400 97011411 97011402 95000963 99170245 97011403 97011412 97011405 97011406 99110942 97011407 97011413 97011409Screw, #10 x 7/8" (4 required)* Housing Assembly (includes Key No. 7) Wiring Adapter Plate Ground Screw, #10-32 x 1/2" Wiring Harness Whiz Nut, 1/4-20 (2 required)* Grille Nut (2 required) Outlet Box Cover Strain Relief Bushing Blower Wheel (MP100) Blower Wheel (MP140) Blower Wheel (MP200) Blower Housing (MP100) Blower Housing (MP140) Blower Housing (MP200) Motor Mounting Rubber (2 required) Motor (MP100) (includes Key No. 16) Motor (MP140) (includes Key No. 16) Motor (MP200) (includes Key No. 16) Motor Cup Screw, #8 x 3/8" (10 required)* Capacitor (MP100) Capacitor (MP140) Capacitor (MP200) Cover Inlet Cover (covers unused inlet ports) Blower Assembly Complete (MP100) (includes Key No.s 10 thru 16) Blower Assembly Complete (MP140) (includes Key No.s 10 thru 16) Blower Assembly Complete (MP200) (includes Key No.s 10 thru 16)

* Standard Hardware - May be purchased locally. ** Not shown assembled. Always order replacement parts by “Part No, - not by “Key No.”

BROAN ONE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.

In the U.S., contact: Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) In Canada, contact: Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario L5T 1H9 (1-888-882-7626)

99041951J

Poser une question sur : Broan MP100

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Broan MP100

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Broan MP100 manuel PDF

8 pages·238 KB·Ventilateur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…