FR
Broan logo
Notice d'utilisation officielle

Broan MODEL 335

12 pages·280 KB·Ventilateur d'extraction·PDF·ENDEITNLJA
Broan MODEL 335
Table des matières 31 sections WARNING · CAUTION · SPECIFICATIONS · PLAN THE INSTALLATION · … AfficherMasquer
Page 1 of the Broan MODEL 335 user manual — INSTALLER: Leave This Manual With The Homeowner
Page 1 · cliquer pour agrandir
Page 1
Broan MODEL 335 — WARNING diagram (page 1)
Fig. 1

MODEL 335 EXTERIOR MOUNTED BLOWER FOR USE WITH RANGEMASTER 60000 OR RM60000 SERIES OR 64000 SERIES RANGE HOODS FOR USE WITH "BEST BY BROAN" K-210A OR K-260A SERIES RANGE HOODS

WARNING

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufac- turer. If you have questions, contact the manufacturer at the address or phone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhaust- ing of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equip- ment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

5. When cutting or drilling into wall, or ceiling, do not damage electrical wiring or other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. To reduce risk of fire, use only metal ductwork. 8. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not use to exhaust hazardous or explosive material and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. Please read specification label on product for further information and requirements. 4. Electrical circuit, including speed control, (if used), must be rated 6 AMPS minimum.

SPECIFICATIONS

Broan MODEL 335 — SPECIFICATIONS diagram (page 1)
Fig. 2
MODELVOLTSAMPSCFMDUCT SIZE 3351203.0120010" DIA.

PLAN THE INSTALLATION

2. Where possible, blower should be centered between wall studs or roof rafters. 3. Avoid pipes, wires, or other ductwork that may be running through the wall. NOTE: Horizontal discharge requires relocation of the duct opening cover plate. See hood manual for instructions.
Broan MODEL 335 — PLAN THE INSTALLATION diagram (page 1)
Fig. 3
1. Locate the blower so the length of the duct run and number of elbows needed are kept to a minimum.

INSTALLER: Leave This Manual With The Homeowner

HOMEOWNER: Use And Care Information On Page 4

Page 2 of the Broan MODEL 335 user manual — 29-1/2" 2"
Page 2 · cliquer pour agrandir
Page 2

PREPARE THE INSTALLATION LOCATION

PREPARE THE INSTALLATION LOCATION

ROOF INSTALLATIONS

WALL INSTALLATIONS

1. Locate the blower on the rear slope of the roof. Place it in a location to minimize duct run. The location should be free of obstacles (T.V. leads, electrical lines, etc.). If the blower top is level with the roof peak, it will not be seen from the street. Keep this approximate location in mind as you work from within the attic.
1. Choose a position on the outside wall. Make sure that no wall studs, pipes or wires run through the opening area.
2. From inside, mark and drill a guide hole centered between wall studs .
2. Mark and drill a guide hole centered between roof rafters .

Ø

17"

Ø

Ø

15"

1¼" dia. hole 1¼" dia. hole

Ø

Guide hole (centered between studs)

Guide hole (centered between studs)

1¼" dia. hole 1¼" dia. hole

3 "

14 11 / 16 "

REMOVE SHINGLES REMOVE SHINGLES

12 11 / 16 "

12 11 / 16 "

20½"

20½"

29½" 29½"

11" dia. hole

11" dia. hole

11" dia. hole

11" dia. hole

REMOVE

SIDING REMOVE

SIDING

9 11 / 16 "

9 13 / 16 "

18"

18"

1113/16" 1113/16"

22"

22"

3. From the outside, use the guide hole as a starting point to lay out the installation: A. Use a T-square to measure 9 13 / 16 " to the left of the
3. From the outside, use the guide hole as a starting point to lay out the installation: A. Use a T-square to measure 11 13 / 16 " to the left of the

guide hole, then up 1211/16" to locate the top-left corner of the layout. B. Starting from the top-left corner, mark the rectangular

guide hole, then up 1411/16" to locate the top-left corner of the layout. B. Starting from the top-left corner, mark the rectan-

cutout (18" W x 20½" H) and remove only the shingles in this area. C. Mark an 11" diameter hole centered on the guide

gular cutout (22" W x 29½" H) and remove only the siding in this area. C. Mark an 11" diameter hole centered on the guide

hole. Cut this hole through the roof board(s). D. Mark and cut a 1¼" diameter hole through the roof

board(s) where shown.

hole. Cut this hole through the roof board(s). D. Mark and cut a 1¼" diameter hole through the roof

board(s) where shown.

29-1/2" 2"

7"

22" 2"

4. For flat roof installations, build a curb that will mount the blower at a minimum pitch of 2/12. Discharge end of the blower should be pointed away from prevailing winds.
Show 12 more labels / short text on this page
17" · 1" · Roof Rafter · Roof Rafter · Roof Rafter · Roof Rafter · Wall Stud · Guide hole · Guide hole · Wall Stud · (centered between rafters) · (centered between rafters)
Page 3 of the Broan MODEL 335 user manual — ROOF INSTALLATIONS
Page 3 · cliquer pour agrandir
Page 3

INSTALL THE BLOWER

INSTALL THE BLOWER

ROOF INSTALLATIONS

WALL INSTALLATIONS

1. Remove the cover and screws.
1. Place a large bead of caulk on the back side of the housing all along the outer edges.
2. Attach an appropriate U.L. approved cable connector in the hole at the rear of the wiring box.
2. Center the blower ring in the 11" diameter hole, making sure that the 1¼" diameter electrical wiring hole aligns with the hole in the wiring box.
3. Remove roofing nails from shingles around the TOP and SIDES of the cutout area only.Carefully lift the shingles to allow the back flashing sheet on the blower housing to fit under them.
3. Attach blower to the wall with the six (6) screws provided. It is recommended that the screws be located inside the blower housing. Drill pilot holes if necessary.
4. Center the blower ring in the 11" diameter hole, making sure that the 1¼" diameter electrical wiring hole aligns with the hole in the wiring box.
4. Using a good grade of caulk, seal all around the mounting screw heads.
5. Attach the blower to the roof with six (6) screws provided. It is recommended that the screws be located inside the blower housing. Drill pilot holes if necessary.
5. Bring electrical wiring through the hole in the wiring box and secure it according to local codes.
6. Using a good grade of roofing cement, seal all of the shingles around the housing and flashing sheet as well as the mounting screw heads.
Broan MODEL 335 — ROOF INSTALLATIONS diagram (page 3)
Fig. 4
7. Bring electrical wiring through the hole in the wiring box and secure it according to local codes.
Broan MODEL 335 — ROOF INSTALLATIONS diagram (page 3)
Fig. 5
6. Make the electrical connections with the proper connector for the type of wire being used. Connect black to black, white to blue, and green or bare wire to grounding screw.
7. Replace cover and screws. Do not pinch wiring under cover.
8. Make the electrical connections with the proper connector for the type of wiring being used. Connect black to black, white to blue, and the green or bare wire to grounding screw.
8. Make sure damper opens and closes freely.
9. Top and side flanges of the back plate may be covered with trim strips. Do not block grille opening at bottom with trim. It will adversely affect performance of the blower.
9. Replace cover and screws. Do not pinch wiring under the cover.
10. Make sure damper opens and closes freely.
Page 4 of the Broan MODEL 335 user manual — 4 99042798C
Page 4 · cliquer pour agrandir
Page 4

SERVICE PARTS Model 335

USE AND CARE

Disconnect electrical power supply and lock out service panel before cleaning or servicing this unit.

KEY NO.PART NO.DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 2198009429 99100532 98009430 98009497 99140145 98009486 99080478 99710036 99271202 99271222 99100530 99390136 99400079 99150478 99170269 99250958 99150506 99270461 99260477 99150471 99160411Cover Foam Seal Motor Support Damper Flap (2 req.) Damper Spring (2 req.) Grille Blower Assembly Spacer Ring Capacitor Wire Assembly Terminal Boot Capacitor Clamp Bushing Screw, 8-18 x 3/8 Ph Tr Hd (12 req.) Screw, M6 x 1-16 (4 req.) Washer, Lock, Int. Tooth, ¼ (5 req.) Screw, 12-24 x .312 SLT HWH #2 Cord Clamp Nut, Whiz, ¼-20 (9 req.) Ground Screw, 10-32 x ½ Slt Hx Hd (2 req.) Screw, ¼-20 x ½ Ph Pan Hd (9 req.)

CLEANING Remove cover and carefully vacuum blower and inside of housing. Be careful not to bend or otherwise damage blower wheel.

MOTOR LUBRICATION The motor is permanently lubricated. Do not oil or disassemble motor.

* Standard Hardware - may be purchased locally. Order replacement parts by Part No. - NOT by Key No.

BROAN-NUTONE ONE YEAR LIMITED WARRANTY Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687) Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario L5T 1H9 (1-888-882-7626)

4 99042798C

Poser une question sur : Broan MODEL 335

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Broan MODEL 335

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Broan MODEL 335 manuel PDF

12 pages·280 KB·Ventilateur d'extraction·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…