FR
Sharp logo
Notice d'utilisation officielle

Sharp AE-XM18CR

219 pages·9.6 MB·Climatiseur·PDF·ENJA
Sharp AE-XM18CR
Table des matières 80 sections AY-XM7CR AY-XM9CR AY-XM1 2CR AY-XPM7CR AY-XPM9CR AY-XPM12CR · AE-XM18CR AE-XM24CR · CONTENTS · PRECAUTIONS · … AfficherMasquer
AY-XM7CR AY-XM9CR AY-XM1 2CR AY-XPM7CR AY-XPM9CR AY-XPM12CRp.1AE-XM18CR AE-XM24CRp.1CONTENTSp.3PRECAUTIONSp.3WARNINGS FOR USEp.3WARNINGS FOR INSTALLATION / REMOVAL / REPAIRp.3CAUTIONS FOR USEp.4CAUTIONS FOR LOCATION / INSTALLATIONp.4ADDITIONAL NOTES ON OPERATIONp.5OPERATING TEMPERATURE RANGEp.5DE-ICING FUNCTIONp.5HEATING EFFICIENCYp.5TIPS ON SAVING ENERGYp.5SET THE CORRECT TEMPERATUREp.5PART NAMESp.6INDOOR UNITp.6OUTDOOR UNITp.6(For models AY-XM7CR, AY-XM9CR, AY-XM12CR) INDOOR UNITp.7AE-XM24CRp.7REMOTE CONTROLp.81 TRANSMITTERp.8: AUTO : LOWp.8: HIGH : SOFTp.8(only for models AY-XPM7CR/AYXPM9CR/AY-XPM12CR) E-6p.8SETTING DUST COLLECTION FILTER AND DEODORANT FILTERp.9(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)p.9USING THE REMOTE CONTROLp.10NOTES:p.10CAUTIONp.11SET CURRENT CLOCK TIMEp.11MODEp.11SWING CLEANp.11SET/Cp.11NOTE:p.11BASIC OPERATIONp.12AUTO HEAT COOL DRYp.12AMp.12DISPLAYp.12FULL POWERp.12TIPS ABOUT AUTO MODEp.1328 18 10 0 34 ( ¡C)p.13-2 ¡Cp.13(¡C)p.13TIPS ABOUT INDICATOR PANELp.13(AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) (AY-XM7CR/AY-XM9CR/AY-XM12CR)p.13ECOp.13POWER MONITORp.13ADJUSTING THE AIR FLOW DIRECTIONp.14VERTICAL AIR FLOW DIRECTIONp.14HOW TO ADJUST THE AIR FLOW DIRECTIONp.14Adjustment rangep.14FULL POWER OPERATIONp.15PMp.15TO CANCELp.15ONE-HOUR OFF TIMERp.15TIMER OPERATIONp.16TIMER OFFp.16TIPS ABOUT TIMER OFF OPERATIONp.16TO CANCEL TIMER MODEp.16COOL/DRY MODE:p.16HEAT MODE:p.16TO CHANGE TIME SETTINGp.16TIMER ONp.17COMBINED USE OF ON AND OFF TIMERSp.17TIPS ABOUT PLASMACLUSTER OPERATIONp.18PLASMACLUSTER OPERATIONp.19You can choose PLASMACLUSTER AUTO OPERATION, AIR CLEAN OPERATION or REFRESHING OPERATIONp.19PLASMACLUSTER AUTO AIR CLEAN REFRESHING CANCELp.19AUTOp.19SELF CLEAN OPERATIONp.19AUXILIARY MODEp.20OPTION KITp.20(only for models AY-XM7CR/AY-XM9CR/AY-XM12CR)p.20MAINTENANCEp.21(for models AY-XM7CR/AY-XM9CR/AY-XM12CR)p.21(for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)p.22BEFORE CALLING FOR SERVICEp.24The following conditions do not denote equipment malfunctionsp.24WATER VAPOURp.24IF THE UNIT FAILS TO OPERATEp.25
Page 1 of the Sharp AE-XM18CR user manual — AY-XM7CR AY-XM9CR AY-XM1 2CR AY-XPM7CR AY-XPM9CR AY-XPM12CR
Page 1 · cliquer pour agrandir
Page 1
Sharp AE-XM18CR — AY-XM7CR AY-XM9CR AY-XM1 2CR AY-XPM7CR AY-XPM9CR AY-XPM12CR diagram (page 1)
Fig. 1
Sharp AE-XM18CR — AY-XM7CR AY-XM9CR AY-XM1 2CR AY-XPM7CR AY-XPM9CR AY-XPM12CR diagram (page 1)
Fig. 2
Sharp AE-XM18CR — AY-XM7CR AY-XM9CR AY-XM1 2CR AY-XPM7CR AY-XPM9CR AY-XPM12CR diagram (page 1)
Fig. 3

ENGLISH DEUTSCH FRANÇAIS ESPAÑOL ITALIANO PORTUGUÊS ΕΛΛΗΝΙΚΑ NEDERLANDS HECCRBQ TÜRKÇE

Sharp AE-XM18CR — AY-XM7CR AY-XM9CR AY-XM1 2CR AY-XPM7CR AY-XPM9CR AY-XPM12CR diagram (page 1)
Fig. 4

MULTI SPLIT TYPE ROOM AIR CONDITIONER MEHRFACH-AUFTEILUNGS- ZIMMER-KLIMAGERÄT CLIMATISEUR DE SALLE DE TYPE A DIVISION MULTIPLE ACONDICIONADOR DE AIRE PARA HABITACIÓN TIPO MULTI DIVISIÓN TIPO A SEZIONE MULTIPLA CONDIZIONATORE D'ARIA PER ABITAZIONI AR CONDICIONADO DE SALA DE MÚLTIPLAS UNIDADES ΣΥΣΚΕΥΗ ΚΛΙΜ∆ΤΙΣΜOΥ ∆ΩΜAΤΙOΥ ΠOΛΛAΠΛOΥ ∆ΙAIPOYMENOY TYΠOY MULTI-SPLIT AIRCONDITIONER MULT∑-SPL∑T KL∑MA RJVZFNZSQ RJZLBWBJZTH DJPLEXF VZJUJ;KJXZJUJ NBGF

  • Uses ozone layer friendly refridgerant R-410A.
  • Verwendet das die Ozonschicht schonende Kühlmittel R-410A.
  • Utilise un réfrigérant qui n’attaque pas la couche d’ozone, le R-410A.
  • Utiliza refrigerante R-410A que no daña la capa de ozono.
  • Utilizza il refrigerante R-410A che non danneggia il buco nell’ozono.
  • Usa refrigerante R-410A amigo da camada de ozono.
  • ρησιµπιεί ψυκτικ R-410A α&λα&ές για τ στρώµα τυ ,ντς.
  • Gebruikt de ozon-vriendelijke koelvloeistof R410A.
  • Ozon tabakasına zarar vermeyen R-410A So©utucu madde kullanılır.
  • Использует охладитель R-410A безвредный для озонового слоя.

INDOOR UNIT ZIMMERGERÄT UNITE INTERIEURE UNIDAD INTERIOR UNITA' INTERNA UNIDADE INTERIOR ΕΣΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ BINNEN-UNIT ∑Ç ÜN∑TE DZENHTZZBQ ;KJR

OUTDOOR UNIT AUSSENGERÄT UNITE EXTERIEURE UNIDAD EXTERIOR UNITA' ESTERNA UNIDADE EXTERIOR ΕΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ BUITEN-UNIT DIΩ ÜN∑TE ZFHEÖZBQ ;KJR

OPERATION MANUAL BEDIENUNGSANLEITUNG NOTICE D'UTILISATION MANUAL DE INSTRUCCIONES MANUALE DI ISTRUZIONE MANUAL DE INSTRUÇÕES ΕΓΕΙΡΙ∆Ι ΛΕΙΤΥΡΓΙΑΣ GEBRUIKSAANWIJZING KULLANMA KILAVUZU РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

AY-XM7CR AY-XM9CR AY-XM1 2CR AY-XPM7CR AY-XPM9CR AY-XPM12CR

AE-XM18CR AE-XM24CR

Page 2 of the Sharp AE-XM18CR user manual — AY-XM7CR AY-XM9CR AY-XM1 2CR AY-XPM7CR AY-XPM9CR AY-XPM12CR
Page 2 · cliquer pour agrandir
Page 2
Page 2 of the Sharp AE-XM18CR user manual — AY-XM7CR AY-XM9CR AY-XM1 2CR AY-XPM7CR AY-XPM9CR AY-XPM12CR
Page 3 of the Sharp AE-XM18CR user manual — Table des matières
Page 3 · Table des matières
Table des matières

Table des matières

AY-XM7CR AY-XM9CR AY-XM1 2CR AY-XPM7CR AY-XPM9CR AY-XPM12CRp.1AE-XM18CR AE-XM24CRp.1CONTENTSp.3PRECAUTIONSp.3WARNINGS FOR USEp.3WARNINGS FOR INSTALLATION / REMOVAL / REPAIRp.3CAUTIONS FOR USEp.4CAUTIONS FOR LOCATION / INSTALLATIONp.4ADDITIONAL NOTES ON OPERATIONp.5OPERATING TEMPERATURE RANGEp.5DE-ICING FUNCTIONp.5HEATING EFFICIENCYp.5TIPS ON SAVING ENERGYp.5SET THE CORRECT TEMPERATUREp.5PART NAMESp.6INDOOR UNITp.6OUTDOOR UNITp.6(For models AY-XM7CR, AY-XM9CR, AY-XM12CR) INDOOR UNITp.7AE-XM24CRp.7REMOTE CONTROLp.81 TRANSMITTERp.8: AUTO : LOWp.8: HIGH : SOFTp.8(only for models AY-XPM7CR/AYXPM9CR/AY-XPM12CR) E-6p.8SETTING DUST COLLECTION FILTER AND DEODORANT FILTERp.9(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)p.9USING THE REMOTE CONTROLp.10NOTES:p.10CAUTIONp.11SET CURRENT CLOCK TIMEp.11MODEp.11SWING CLEANp.11SET/Cp.11NOTE:p.11BASIC OPERATIONp.12AUTO HEAT COOL DRYp.12AMp.12DISPLAYp.12FULL POWERp.12TIPS ABOUT AUTO MODEp.1328 18 10 0 34 ( ¡C)p.13-2 ¡Cp.13(¡C)p.13TIPS ABOUT INDICATOR PANELp.13(AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) (AY-XM7CR/AY-XM9CR/AY-XM12CR)p.13ECOp.13POWER MONITORp.13ADJUSTING THE AIR FLOW DIRECTIONp.14VERTICAL AIR FLOW DIRECTIONp.14HOW TO ADJUST THE AIR FLOW DIRECTIONp.14Adjustment rangep.14FULL POWER OPERATIONp.15PMp.15TO CANCELp.15ONE-HOUR OFF TIMERp.15TIMER OPERATIONp.16TIMER OFFp.16TIPS ABOUT TIMER OFF OPERATIONp.16TO CANCEL TIMER MODEp.16COOL/DRY MODE:p.16HEAT MODE:p.16TO CHANGE TIME SETTINGp.16TIMER ONp.17COMBINED USE OF ON AND OFF TIMERSp.17TIPS ABOUT PLASMACLUSTER OPERATIONp.18PLASMACLUSTER OPERATIONp.19You can choose PLASMACLUSTER AUTO OPERATION, AIR CLEAN OPERATION or REFRESHING OPERATIONp.19PLASMACLUSTER AUTO AIR CLEAN REFRESHING CANCELp.19AUTOp.19SELF CLEAN OPERATIONp.19AUXILIARY MODEp.20OPTION KITp.20(only for models AY-XM7CR/AY-XM9CR/AY-XM12CR)p.20MAINTENANCEp.21(for models AY-XM7CR/AY-XM9CR/AY-XM12CR)p.21(for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)p.22BEFORE CALLING FOR SERVICEp.24The following conditions do not denote equipment malfunctionsp.24WATER VAPOURp.24IF THE UNIT FAILS TO OPERATEp.25
Page 4 of the Sharp AE-XM18CR user manual — CAUTIONS FOR LOCATION / INSTALLATION
Page 4 · cliquer pour agrandir
Page 4

PRECAUTIONS

CAUTIONS FOR USE

1 Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage. 2 Do not operate the buttons with wet hand. It may cause electric shock. 3 For safety, turn the circuit breaker off when not using the unit for an extended period of time. 4 Check the outdoor unit mounting rack periodically for wear and to make sure it is firmly in place. 5 Do not put anything on the outdoor unit nor step on it. The object or the person may fall down or drop, causing injury. 6 This unit is designed for residential use. Do not use for other applications such as in a kennel or greenhouse to raise animals or grow plants. 7 Do not place a vessel with water on the unit. If water penetrates into the unit, electrical insulations may deteriorate and cause electric shock. 8 Do not block the air inlets nor outlets of the unit. It may cause insufficient performance or troubles. 9 Be sure to stop the operation and turn the circuit breaker off before performing any maintenance or cleaning. A fan is rotating inside the unit and you may get injured. 10 Do not splash or pour water directly on the unit. Water can cause electrical shock or equipment damage. 11 This appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance.

CAUTIONS FOR LOCATION / INSTALLATION

  • Make sure to connect the air conditioner to power supply of the rated voltage and frequency. Use of a power supply with improper voltage and frequency can result in equipment damage and possible fire.
  • Do not install the unit in a place where inflammable gas may leak. It may cause fire. Install the unit in a place with minimal dust, fumes and moisture in the air.
  • Arrange the drain hose to ensure smooth drainage. Insufficient drainage may cause wetting of the room, furniture etc.
  • Make sure a leak breaker or a circuit breaker is installed, depending on the installation location, to avoid electrical shock.
Page 5 of the Sharp AE-XM18CR user manual — SET THE CORRECT TEMPERATURE
Page 5 · cliquer pour agrandir
Page 5

ADDITIONAL NOTES ON OPERATION

OPERATING TEMPERATURE RANGE

INDOOR TEMP.OUTDOOR TEMP. COOLINGupper limit32˚C D.B. 23˚C W.B.43˚C D.B. - lower limit21˚C D.B. 15˚C W.B.21˚C D.B. - HEATINGupper limit27˚C D.B. -24˚C D.B. 18˚C W.B. lower limit20˚C D.B. --7˚C D.B. -8˚C W.B.
  • The built-in protective device may prevent the unit from operating when used out of this range.
  • Condensation may form on the air outlet if the unit operates continuously in the COOL or DRY mode when humidity is over 80 percent.

D.B. = Dry-bulb W.B. = Wet-bulb

WHEN POWER FAILURE OCCURS This air conditioner has a memory function to store settings when a power failure occurs. After power recovery, the unit will automatically re-start in the same settings which were active before the power failure, except for timer settings. If the timers were set before a power failure, they will need to be re-set after power recovery.

PREHEATING FUNCTION In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on to prevent cold air from blowing out of the unit.

DE-ICING FUNCTION

  • When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an automatic de-icer provides heat for about 5 to 10 minutes to remove the ice. During de-icing, the inside and outside fans stop operating.
  • After de-icing is completed, the unit automatically resumes operation in the HEAT mode.

HEATING EFFICIENCY

  • The unit employs a heat pump that draws heat from the outside air and releases it into the room. The outside air temperature therefore greatly affects the heating efficiency.
  • If the heating efficiency is reduced due to low outside temperatures, use an additional heater.
  • It takes time to warm up and heat the entire room because of the forced air circulation system.

TIPS ON SAVING ENERGY

Below are some simple ways to save energy when you use your air conditioner.

SET THE CORRECT TEMPERATURE

  • Setting the thermostat 1°C higher than the desired temperature in the COOL mode and 2°C lower in the HEAT mode will save approximately 10 percent in power consumption.
  • Setting the temperature lower than necessary during cooling operation will result in increased power consumption. BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS
  • Blocking direct sunlight during cooling operation will reduce power consumption.
  • Close the windows and doors during cooling and heating operations. SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR CIRCULATION KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION MAKE MOST OF THE TIMER OFF FUNCTION DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN EXTENDED PERIOD OF TIME
  • The indoor unit still consumes a small amount of power when it is not operating.
Page 6 of the Sharp AE-XM18CR user manual — OUTDOOR UNIT
Page 6 · cliquer pour agrandir
Page 6

PART NAMES

INDOOR UNIT

(For models AY-XPM7CR, AY-XPM9CR, AY-XPM12CR)

1 DUST COLLECTION FILTER (non-washable)

Sharp AE-XM18CR — INDOOR UNIT diagram (page 6)
Fig. 5

2 DEODORANT FILTER (washable)

6 AUX. Button

9 Vertical Adjustment Louvres

0 Horizontal Adjustment Louvres

e OUTDOOR Temp. Lamp

t ROOM Temp. Lamp

e r t y u i o

i TIMER Lamp (orange )

o OPERATION Lamp (red )

OUTDOOR UNIT

Sharp AE-XM18CR — OUTDOOR UNIT diagram (page 6)
Fig. 6
Show 23 more labels / short text on this page
3 Inlet (Air) · 4 Open Panel · 5 Air Filters · 7 RECEIVER Window · 8 Indicator Panel · q Outlet (Air) · w Remote Control · q · w · (green ) · r TEMPERATURE INDICATOR · (green ) · y POWER MONITOR · u PLASMACLUSTER Lamp · (blue,green) · ! Inlet (Air) · ! · @ Interconnecting · @ · # CordRefrigerant Tube · # · $ Outlet (Air) · $
Page 7 of the Sharp AE-XM18CR user manual — AE-XM24CR
Page 7 · cliquer pour agrandir
Page 7

(For models AY-XM7CR, AY-XM9CR, AY-XM12CR) INDOOR UNIT

Sharp AE-XM18CR — (For models AY-XM7CR, AY-XM9CR, AY-XM12CR) INDOOR UNIT diagram (page 7)
Fig. 7 · (For models AY-XM7CR, AY-XM9CR, AY-XM12CR) INDOOR UN…

4 AUX. Button

7 Vertical Adjustment Louvres

8 Horizontal Adjustment Louvres

e OUTDOOR Temp. Lamp

q w e r t y

r ROOM Temp. Lamp

t TIMER Lamp (orange )

y OPERATION Lamp (red )

OUTDOOR UNIT

AE-XM24CR

Sharp AE-XM18CR — AE-XM24CR diagram (page 7)
Fig. 8

# Refrigerant Tube and

Show 18 more labels / short text on this page
1 Inlet (Air) · 2 Open Panel · 3 Air Filters · 5 RECEIVER Window · 6 Indicator Panel · 9 Outlet (Air) · 0 Remote Control · q POWER MONITOR · w TEMPERATURE INDICATOR · (green ) · (green ) · ! Inlet (Air) · ! · @ Interconnecting Cord · @ · # · $ Outlet (Air) · $
Page 8 of the Sharp AE-XM18CR user manual — : AUTO : LOW
Page 8 · cliquer pour agrandir
Page 8

PART NAMES

REMOTE CONTROL

1 TRANSMITTER

Sharp AE-XM18CR — 1 TRANSMITTER diagram (page 8)
Fig. 9

2 DISPLAY (Liquid Crystal Display)

4 FULL POWER Button

6 THERMO. (Thermostat) Button

9 ONE-HOUR OFF TIMER Button

0 TIMER ON Button (for setting the timer)

q TIMER OFF Button (for setting the timer)

7 8 9 0 q

(only for models AY-XPM7CR/AY-XPM9CR/AY- XPM12CR)

e TIME ADVANCE Button

r TIME REVERSE Button

t SELF CLEAN Button

w e r t y u

(only for models AY-XPM7CR/AY-XPM9CR/AY- XPM12CR)

y TIMER SET/CANCEL Button

u Indicates BATTERY COMPARTMENT is

Sharp AE-XM18CR — 1 TRANSMITTER diagram (page 8)
Fig. 10

j TIMER ON INDICATOR/CLOCK

Indicates the on timer preset time or current time.

g FULL POWER SYMBOL

k TIMER OFF INDICATOR

h FAN SPEED SYMBOLS

Indicates the preset time for off timer or one- hour off timer.

: AUTO : LOW

: HIGH : SOFT

(only for models AY-XPM7CR/AYXPM9CR/AY-XPM12CR) E-6

Show 16 more labels / short text on this page
3 DISPLAY Button · 5 ON/OFF Button · 7 MODE Button · 8 FAN Button · w PLASMACLUSTER Button · below this mark · i o · i CLOCK Button · o SWING Button · p a · f · s d · g h · j k l · f TEMPERATURE INDICATOR · l PLASMACLUSTER SYMBOL
Page 9 of the Sharp AE-XM18CR user manual — (only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
Page 9 · cliquer pour agrandir
Page 9

SETTING DUST COLLECTION FILTER AND DEODORANT FILTER

(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)

The dust collection filter and the deodorant filter are packed as accessory of this unit. During operation of the air conditioner, the filters remove dust and tobacco smoke from the air and discharges clean air.

1 Take out the air filters. 1 Open the open panel. 2 Push the air filters up slightly to unlock them. 3 Pull the air filters down to remove them.

Sharp AE-XM18CR — (only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) diagram (page 9)
Fig. 11 · (only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)

DUST COLLECTION FILTER (gray) Set the black side facing upward.

2 Set the dust collection filter and the deo- dorant filter under the filter stoppers lo- cated on the air filter.

3 Reinstall the air filters 1 Reinstall the air filters in the original positions. 2 Close the open panel. 3 Push the arrow-marked of the panel firmly to lock it in place.

Sharp AE-XM18CR — (only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) diagram (page 9)
Fig. 12 · (only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
  • Precautions
  • The filters are sealed in a plastic bag to keep their dust collection effect. Do not open the bag until using the filters. (Otherwise the filters life may get shorter.)
  • Do not expose the filters to direct sunlight. (Otherwise they may deteriorate.)

Filter stopper · DEODORANT FILTER (green) · Filter stopper

Page 10 of the Sharp AE-XM18CR user manual — NOTES:
Page 10 · cliquer pour agrandir
Page 10

USING THE REMOTE CONTROL

LOADING BATTERIES Use two size-AAA (R03) batteries.

1 Remove the remote control cover. 2 Insert batteries in the compart- ment, making sure the ± and

— polarities are correctly aligned.

  • The display indicates "AM 6:00" when batteries are properly installed. 3 Reinstall the cover.

NOTES:

  • The battery life is approximately one year in normal use.
  • When you replace the batteries, always change both batteries, and make sure they are the same type.
  • If the remote control does not operate properly after replacing the batteries, take out the batteries and reinstall them again after 30 seconds.
  • If you will not be using the unit for a long time, remove the batteries from the remote control.
Sharp AE-XM18CR — NOTES: diagram (page 10)
Fig. 13

Point the remote control towards the unit’s signal receiver window and press the desired button. The unit generates a beep when it re- ceives the signal.

  • Make sure there is no curtain or other object between the remote control and the unit.
  • The remote control can send signals from up to 7 metres away.

Remote control cover · + - · +

Page 11 of the Sharp AE-XM18CR user manual — NOTE:
Page 11 · cliquer pour agrandir
Page 11

CAUTION

  • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light.
  • Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal.
  • The unit can be affected by signals transmitted from the remote control of a television, VCR or other equipment used in the same room.
  • Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit and remote control from moisture and shock which can discolour or damage them.

SET CURRENT CLOCK TIME

There are two clock modes: 12-hour mode and 24-hour mode.

Example5 o'clock in the afternoon
ClockDisplay 12-hour modePM 5:00 24-hour mode17:00

1 To set to the 12-hour mode, press the CLOCK button once in the first step. To set to the 24-hour mode, press the CLOCK button twice in the first step. 2 Press the TIME ADVANCE or REVERSE button to set the current time.

MODE

SWING CLEAN

SET/C

  • Keep the button pressed to advance or reverse the time display quickly. 3 Press the SET/C button.
  • The colon (:) blinks to indicate that the clock is functioning.
Sharp AE-XM18CR — MODE diagram (page 11)
Fig. 14

The PLASMACLUSTER and the SELF CLEAN buttons are provided only on models AY-XPM7CR/AY-XPM9CR/ AY-XPM12CR.

NOTE:

  • The current time cannot be set when the timer is operating.

1h

Page 12 of the Sharp AE-XM18CR user manual — NOTES:
Page 12 · cliquer pour agrandir
Page 12

BASIC OPERATION

Press the MODE button to select the op- eration mode.

AUTO HEAT COOL DRY

AM

2 Press the ON/OFF button to start opera- tion.

  • The red OPERATION lamp ( ) on the unit will light.

DISPLAY

FULL POWER

Press the THERMO. button to set the de- sired temperature.

(Example1°C higher)
  • In the AUTO and DRY mode, the temperature can be changed in 1°C incerments within the range of 2°C higher to 2°C lower from the temperature automatically determined by the air conditioner.
  • In the COOL and HEAT modes, the temperature can be set within the range of 18 to 32°C.

MODE

(Example2°C lower)

SWING CLEAN

SET/C

Sharp AE-XM18CR — SWING CLEAN diagram (page 12)
Fig. 15

Press the FAN button to set the desired fan speed. AUTO SOFT LOW HIGH

  • In the DRY mode, the fan speed is preset to AUTO and cannot be changed.

To turn off the unit, press the ON/OFF but- ton again.

The PLASMACLUSTER and the SELF CLEAN buttons are provided only on models AY-XPM7CR/AY- XPM9CR/AY-XPM12CR.

  • The red OPERATION lamp ( ) on the unit will turn off.

NOTES:

  • This air conditioner is a multi-type, and two (or three) indoor units are connected to one outdoor unit. When the setting mode differs among indoor unit(s), the indoor unit(s) operated later may not work.
  • When the indoor unit(s) is/are operating in HEAT mode, the remaining unit(s) can not operate in COOL or DRY mode.
  • When the indoor unit(s) is/are operating in COOL or DRY mode, the remaining unit(s) can not operate in HEAT mode. When the mode of the indoor unit(s) later operated is/are different from those which is/are in operation, 4 seconds later, a long BEEP will be emitted and the temperature indicator on the indicator panel will indicate" " and the OPERATION lamp and TIMER lamp will blink alternately. This shows that the later operated unit(s) is/are not working. In such case, change the remote control's mode and send the same mode signal which the other indoor unit(s) is/are operating in. The BEEP will be emitted twice from the indoor unit(s) later operated, and the unit(s) will operate.

1h

Page 13 of the Sharp AE-XM18CR user manual — ECO
Page 13 · cliquer pour agrandir
Page 13

TIPS ABOUT AUTO MODE

In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature and outdoor temperature when the unit is turned on.

Modes and Temperature Settings

  • During operation, if the outdoor temperature changes, the temperature settings will automatically slide as shown in the chart.
  • Mode of the unit operated first will have priority over other unit(s) without reference to the chart.

outdoor temp.

28 18 10 0 34 ( ¡C)

Sharp AE-XM18CR — 28 18 10 0 34 ( ¡C) diagram (page 13)
Fig. 16

Dry ( ) Heat (23¡C) Heat (24¡C)

Room Temp.

-2 ¡C

indoor temp.

(¡C)

the figures in ( ) are temperature settings

TIPS ABOUT INDICATOR PANEL

The indicator panel will change each time you press the DISPLAY button in the following manner.

DISPLAY

FULL POWER

(AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) (AY-XM7CR/AY-XM9CR/AY-XM12CR)

The room temperature and POWER MONITOR are displayed.

ECO

ECO

temperature Indiactor POWER MONITOR

Room Temp. Lamp

Room Temp. Lamp

POWER MONITOR

The outdoor temperature and POWER MONITOR are displayed.

ECO

ECO

Outdoor Temp. Lamp

Outdoor Temp. Lamp

No display.

POWER MONITOR When the room temperature or the outdoor temperature is displayed, the POWER MONITOR will light up in 4 levels for COOL and HEAT modes (3 levels for DRY mode), to indicate the operation power. When the air conditioner is operating at maximum power in the COOL and HEAT modes, "POWER" will light and "ECO" will turn off on the indicator panel. NOTES:

  • The displayed temperatures are rough estimates and may vary from the actual temperatures.
  • Temperature display ranges Room temperature: 0°C ~ 40°C ( is displayed when less than 0°C and when higher than 40°C) Outdoor temperature: -9°C ~ 45°C ( is displayed when less than -9°C and when higher than 45°C)
  • is displayed during the first 120 seconds of operation while the temperatures are being detected. (Temperature detection may more than 120seconds when other unit(s) is/are already being operated.)
  • is displayed for 5 seconds when the unit is not in operation.
Show 5 more labels / short text on this page
Cool (24¡C) · Cool (25¡C) · Cool (26¡C) · Heat (22¡C) · temperature Indiactor
Page 14 of the Sharp AE-XM18CR user manual — Adjustment range
Page 14 · cliquer pour agrandir
Page 14

ADJUSTING THE AIR FLOW DIRECTION

VERTICAL AIR FLOW DIRECTION

The air flow direction is automatically preset in each mode as follows for optimum comfort:

COOL and DRY modes Horizontal air flow HEAT mode Diagonal air flow

HOW TO ADJUST THE AIR FLOW DIRECTION

  • Press the SWING button on the remote control once.
  • The vertical adjustment louvre will change its angle continuously. Press the SWING button again when the vertical adjustment louvre is at the desired position.
  • The louvre will stop moving within the range shown in the diagram.
  • The adjusted position will be memorized and will be automatically set to the same position when operated the next time.

Adjustment range

COOL and DRY modes HEAT mode

The adjustment range is narrower the SWING range in order to pre- vent condensation from dripping.

The range is wide so the air flow can be directed toward the floor.

Sharp AE-XM18CR — Adjustment range diagram (page 14)
Fig. 17 · Adjustment range

Hold the horizontal adjustment louvre as shown in the diagram and adjust the air flow direction.

Never attempt to adjust the vertical adjustment louvres manually.

  • Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction when the remote control is used for the adjustment.
  • When the vertical adjustment louvre is positioned at the lowest position in the COOL or DRY mode for an extended period of time, condensation may result. Do not adjust the horizontal adjustment louvre extremely to the right or left when operating the air conditioner with fan speed "SOFT" for an extended period of time. Condensation may form on the louvres.
Page 15 of the Sharp AE-XM18CR user manual — NOTES:
Page 15 · cliquer pour agrandir
Page 15

FULL POWER OPERATION

In this operation, the air conditioner works at maximum power to makes the room cool or warm so rapidly that you can use it just after you come home.

1 To activate the FULL POWER operation, press the FULL POWER button during operation.

  • The remote control will display .
  • The temperature display will go off.

PM

TO CANCEL

Press the FULL POWER button again.

  • FULL POWER operation will also be cancelled when the operation mode is changed, or when the unit is turned off.

DISPLAY

FULL POWER

NOTE:

  • You cannot set the temperature and fan speed during the FULL POWER operation.

ONE-HOUR OFF TIMER

When the ONE-HOUR OFF TIMER is set, the unit will stop operating after one hour.

1 Press the ONE-HOUR OFF TIMER button.

  • The remote control displays “ ”.
  • The orange TIMER lamp ( ) on the unit will light up.
  • The unit will stop operating after one hour.

TO CANCEL

Press the TIMER CANCEL (SET/C) button. • The orange TIMER lamp ( ) on the unit will turn off.

Or, turn the unit off by pressing the ON/OFF button.

  • The red OPERATION lamp ( ) and the orange TIMER lamp ( ) on the unit will turn off.

The PLASMACLUSTER and the SELF CLEAN buttons are provided only on models AY-XPM7CR/AY- XPM9CR/AY-XPM12CR.

NOTES:

  • The ONE-HOUR OFF TIMER operation has priority over TIMER ON and TIMER OFF operations.
  • When the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit will operate for an hour with the formerly set condition.
  • If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER activates, press the ONE-HOUR OFF TIMER button again during operation.
  • If TIMER ON and/or TIMER OFF are set, TIMER CANCEL button cancels every setting.

MODE 1h

Page 16 of the Sharp AE-XM18CR user manual — TO CHANGE TIME SETTING
Page 16 · cliquer pour agrandir
Page 16

TIMER OPERATION

TIMER OFF

1 Press the TIMER OFF ( ) button. 2 The TIMER OFF indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the desired time. (The time can be set in 10- minute increments.) 3 Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button.

AM

DISPLAY

  • The orange TIMER lamp ( ) on the unit will light.
  • The unit will generate a beep when it receives the signal.

FULL POWER

MODE

SWING CLEAN

SET/C

The PLASMACLUSTER and the SELF CLEAN buttons are provided only on models AY-XPM7CR/AY-XPM9CR/ AY-XPM12CR.

TIPS ABOUT TIMER OFF OPERATION

TO CANCEL TIMER MODE

When the TIMER OFF mode is set, the temperature setting is automatically adjusted to prevent the room from becoming excessively hot or too cold while you sleep. (Auto Sleep function)

Press the TIMER CANCEL (SET/C) button.

  • The orange TIMER lamp ( ) on the unit will turn off.
  • The current clock time will be displayed on the remote control.

MODE

COOL/DRY MODE:

  • One hour after the time operation begins, the temperature setting rises 1°C higher than the original thermostat setting.

The PLASMACLUSTER and the SELF CLEAN buttons are provided only on models AY- XPM7CR/AY-XPM9CR/AY- XPM12CR.

SWING CLEAN

SET/C

HEAT MODE:

NOTE:

  • One hour after the timer operation begins, the temperature setting drops 3°C lower than the original thermostat setting.
  • If any TIMER ON, TIMER OFF and ONE-HOUR OFF TIMER are set, the TIMER CANCEL button cancels all settings.

TO CHANGE TIME SETTING

Cancel the TIMER seting first, then set it again.

1h · 1h

Page 17 of the Sharp AE-XM18CR user manual — NOTES:
Page 17 · cliquer pour agrandir
Page 17

TIMER ON

1 Press the TIMER ON ( ) button. 2 The TIMER ON indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the de- sired time. (The time can be set in 10-minute increments.) 3 Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button.

AM

DISPLAY

  • The orange TIMER lamp ( ) on the unit will light.
  • The unit will generate a beep when it receives the signal. 4 Select the operation condition.
  • The unit will turn on prior to the set time to allow the room to reach the desired temperature by the programmed time. (Awaking function)
  • If unit(s) is/are operated in one mode while TIMER ON is set with another unit in different mode, the timer may not activate the required operation.

FULL POWER

MODE

SWING CLEAN

SET/C

The PLASMACLUSTER and the SELF CLEAN buttons are provided only on models AY-XPM7CR/AY-XPM9CR/ AY-XPM12CR.

COMBINED USE OF ON AND OFF TIMERS

You can use the ON and OFF timers in combination.

Example: To stop operation at 11:00 p.m. and resume opera- tion (With the same mode and temperature settings) to bring the room temperature to the desired level by 7:00 a.m. 1 Set the TIMER OFF to 11:00 p.m. during opera- tion. 2 Set the TIMER ON to 7:00 a.m.

AM

PM

The arrow ( or ) between the TIMER ON indicator and the TIMER OFF indicator shows which timer will activate first.

NOTES:

  • You cannot programme the ON-TIMER and OFF-TIMER to operate the unit at different temperatures or other settings.
  • Either timer can be programmed to activate prior the other.

1h

Page 18 of the Sharp AE-XM18CR user manual — (only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
Page 18 · cliquer pour agrandir
Page 18

TIPS ABOUT PLASMACLUSTER OPERATION

(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)

The ionizer inside the air conditioner will release cluster ions, which are collective mass of positive and negative ions, into the room. The cluster ions reduce airborne mold fungus and deodorize/decompose odor- causing molecules.

Cluster ions Mold fungus Odor

AIR CLEAN OPERATION Cluster ions released into the air will reduce airborne mold fungus and deodorize/decompose odor-causing molecules.

REFRESHING OPERATION It is said that plenty of negative ions exist in places such as waterfalls or forests in natural environment. In this operation mode, negative inos will be released in an increased rate, in order to bring the room air close to this condition.

PLASMACLUSTER AUTO OPERATION Dust sensor and odor sensor will detect foul air in the room. Air Clean Operation will be performed for one minute after the air conditioner is operated to detect foul air. Air Clean Operation and Refreshing Operation will be selected and be performed automatically depending on the air foul degree. Air Clean Operation will be performed when the air is detected to be foul, Refreshing Operation will be performed when the air is clean.

SELF CLEAN OPERATION Plasmacluster Operation will be performed with FAN or HEAT mode, in order to reduce the growth of mold fungus, and dry inside of the air conditioner unit. Utilize the operation at seasonal change over terms. Mold fungus already grown can not be eliminated by this operation.

  • Dust sensor reacts to mold fungus, plants/flowers pollen, dead ticks, dust, tobacco smoke etc.

What does Odor Sensor react to? • Odor Sensor reacts to tobacco smoke, motor exhaust, odor emitted from animals, etc.

Dust and Odor Sensor also may react to vapour of insecticides, cosmetics, alcohol, chemicals and the like, and to extreme change of temperature/humidity.

Ionizer

Page 19 of the Sharp AE-XM18CR user manual — SWING CLEAN
Page 19 · cliquer pour agrandir
Page 19

PLASMACLUSTER OPERATION

(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)

You can choose PLASMACLUSTER AUTO OPERATION, AIR CLEAN OPERATION or REFRESHING OPERATION

1 When the unit is in operation, press the PLASMACLUSTER button to select the mode.

PLASMACLUSTER AUTO AIR CLEAN REFRESHING CANCEL

AUTO

AM

  • In the AIR CLEAN operation, the blue PLASMACLUSTER lamp on the unit will light up.
  • In the REFRESHING operation, the green PLASMACLUSTER lamp on the unit will light up.

MODE

TO CANCEL

Press the PLASMACLUSTER button until PLASMACLUSTER symbol on the remote control display goes off. • The PLASMACLUSTER lamp on the unit will turn off.

SWING CLEAN

SET/C

  • NOTES:
  • Setting of the PLASMACLUSTER operation will be memorized and will operate in the same mode, the next time you turn on the air conditioner.
  • To turn off the PLASMACLUSTER lamp, press the DISPLAY button.
  • When the PLASMACLUSTER button is pressed while the unit is not operating, the PLASMACLUSTER operation will be performed without accompanying air conditioning mode (eg. HEATING or COOLING).The mode symbol of the remote control will go off and the fan speed can not be set AUTO. At this time, you may feel HEATING is performed with units in other rooms. Indoor fan will decrease its rotating speed and will ture ON and OFF depending on the room temperature.

SELF CLEAN OPERATION

(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)

  • 1 Press the SELF CLEAN button when the unit is not operating.
  • The remote control displays " ".
  • The red OPERATION lamp ( ) and the blue PLASMACLUSTER lamp on the unit will light up.
  • The unit will stop operation after forty minutes.
  • The remaining operation time will be indicated on the TEMPERATURE INDICATOR of the indoor unit in minute decrements.

AM

TO CANCEL

Press the SELF CLEAN button. Or, turn the unit off by pressing the ON/OFF button. • The red OPERATION lamp ( ),the blue PLASMACLUSTER lamp and the TEMPERATURE INDICATOR on the unit will turn off.

SWING CLEAN

SET/C

1h

Page 20 of the Sharp AE-XM18CR user manual — (only for models AY-XM7CR/AY-XM9CR/AY-XM12CR)
Page 20 · cliquer pour agrandir
Page 20

AUXILIARY MODE

Use this mode when the remote control is not available.

Sharp AE-XM18CR — AUXILIARY MODE diagram (page 20)
Fig. 18

Lift the front panel of the indoor unit and press the AUX. button on the operation panel.

  • The red OPERATION lamp ( ) on the unit will light and the unit will start operating in the AUTO mode.
  • The fan speed and temperature setting are set to AUTO.

Press the AUX. button on the operation panel again.

  • The red OPERATION lamp ( ) on the unit will turn off.

OPTION KIT

(only for models AY-XM7CR/AY-XM9CR/AY-XM12CR)

Sharp AE-XM18CR — (only for models AY-XM7CR/AY-XM9CR/AY-XM12CR) diagram (page 20)
Fig. 19 · (only for models AY-XM7CR/AY-XM9CR/AY-XM12CR)

Air Purifying Filter During operation of the air conditioner, the air purifying filter removes dust and tobacco smoke from the air and discharges clean air. The apatite antibacterial material used in the air purifying filter suppresses activities of adsorbed viruses and other germs. The replacement period for the disposable type is approximately 3~6 months. Contact your dealer for the purchase of this option.

Page 21 of the Sharp AE-XM18CR user manual — (for models AY-XM7CR/AY-XM9CR/AY-XM12CR)
Page 21 · cliquer pour agrandir
Page 21

MAINTENANCE

(for models AY-XM7CR/AY-XM9CR/AY-XM12CR)

Be sure to turn off the air conditioner and turn off the circuit breaker before perform- ing any maintenance.

Sharp AE-XM18CR — (for models AY-XM7CR/AY-XM9CR/AY-XM12CR) diagram (page 21)
Fig. 20 · (for models AY-XM7CR/AY-XM9CR/AY-XM12CR)

CLEANING THE FILTERS The air filters should be cleaned every two weeks.

2 REMOVE THE FILTERS 1 Lift the open panel. 2 Push the air filters up slightly to unlock them. 3 Pull the air filters down to remove them.

3 CLEAN THE FILTERS Use a vacuum cleaner to remove dust. If the filters are dirty, wash them with warm water and a mild detergent. Dry filters in the shade before reinstalling.

4 REINSTALL THE FILTERS 1 Reinstall the filters in the original positions. 2 Close the front panel. 3 Push the arrow-marked of the panel firmly to lock it in place.

Sharp AE-XM18CR — (for models AY-XM7CR/AY-XM9CR/AY-XM12CR) diagram (page 21)
Fig. 21 · (for models AY-XM7CR/AY-XM9CR/AY-XM12CR)
  • Wipe them with a soft cloth.
  • Do not directly splash or pour water on them. We can cause electrical shock or equipment damage.
  • Do not use hot water, thinner, abrasive powders or strong solvents.
Sharp AE-XM18CR — (for models AY-XM7CR/AY-XM9CR/AY-XM12CR) diagram (page 21)
Fig. 22 · (for models AY-XM7CR/AY-XM9CR/AY-XM12CR)

1 Operate the unit in the COOL mode, temperature setting 32°C, for about half a day to allow the mechanism to thoroughly dry. 2 Stop the operation. Turn off the circuit breaker, if you have one exclusively for the air conditioner. 3 Clean the filters, then reinstall them.

1 Make sure that the air filters are not dirty. 2 Make sure that nothing obstructs the air inlet or outlet. 3 Check the outdoor mounting rack periodically for wear and to make sure it is firmly in place.

Page 22 of the Sharp AE-XM18CR user manual — (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
Page 22 · cliquer pour agrandir
Page 22

MAINTENANCE

(for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)

Be sure to turn off the air conditioner and turn off the circuit breaker before perform- ing any maintenance.

CLEANING THE FILTERS The air filters should be cleaned every two weeks.

1 TURN OFF THE UNIT 2 REMOVE THE FILTERS 1 Lift the open panel. 2 Push the air filters up slightly to unlock them. 3 Pull the air filters down to remove them. 3 TAKE OFF THE DEODORANT FILTER AND THE DUST COLLECTION FILTER FROM THE AIR FILTERS 4 CLEAN THE FILTERS Use a vacuum cleaner to remove dust. If the filters are dirty, wash them with warm water and a mild detergent. Dry filters in the shade before reinstalling. 5 REINSTALL THE DEODORANT FILTER AND THE DUST COLLECTION FILTER 6 REINSTALL THE FILTERS 1 Reinstall the filters in the original positions. 2 Close the front panel. 3 Push the arrow-marked of the panel firmly to lock it in place.

Sharp AE-XM18CR — (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) diagram (page 22)
Fig. 23 · (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
Sharp AE-XM18CR — (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) diagram (page 22)
Fig. 24 · (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
Sharp AE-XM18CR — (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) diagram (page 22)
Fig. 25 · (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
  • Wipe them with a soft cloth.
  • Do not directly splash or pour water on them. We can cause electrical shock or equipment damage.
  • Do not use hot water, thinner, abrasive powders or strong solvents.
Sharp AE-XM18CR — (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) diagram (page 22)
Fig. 26 · (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)

1 Operate the unit in the SELF CLEAN OPERATION to allow the mechanism to thoroughly dry. 2 Stop the operation. Turn off the circuit breaker, if you have one exclusively for the air conditioner. 3 Clean the filters, then reinstall them.

1 Make sure that the air filters are not dirty. 2 Make sure that nothing obstructs the air inlet or outlet. 3 Check the outdoor mounting rack periodically for wear and to make sure it is firmly in place.

Page 23 of the Sharp AE-XM18CR user manual — (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
Page 23 · cliquer pour agrandir
Page 23
Sharp AE-XM18CR — (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) diagram (page 23)
Fig. 27 · (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)

1 REMOVE THE AIR FILTERS 2 CLEAN THE DEODORANT FILTER 1 Take off the deodorant filter from the air filters. 2 Soak the deodorant filter in mild detergent dilution for 10 to 20 minutes. Rinse thoroughly with water, dry completely under sunlight. 3 Set the clean deodorant filter under the fil- ter stoppers located on the air filters. 3 REINSTALL THE AIR FILTERS

Sharp AE-XM18CR — (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) diagram (page 23)
Fig. 28 · (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)

1 REMOVE THE AIR FILTERS 2 CHANGE THE DUST COLLECTION FILTER 1 Take off the old dust collection filter from the air filters. 2 Set the new dust collection filter, the black side facing upward, under the filter stop- pers located on the air filters. 3 REINSTALL THE AIR FILTERS NOTE: • The dirty dust collection filter is not washable for reuse. The new filters are available at your nearest dealer.

Page 24 of the Sharp AE-XM18CR user manual — (only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)
Page 24 · cliquer pour agrandir
Page 24

BEFORE CALLING FOR SERVICE

The following conditions do not denote equipment malfunctions

UNIT DOES NOT OPERATE The unit will not operate if it is turned on immediately after it is turned off. The unit will not operate immediately after the mode is changed. This is to protect the internal mechanisms. Wait 3 minutes before operating the unit.

WATER VAPOUR

  • In the COOL and DRY operation, water vapour can sometimes be seen at the air outlet due to the difference between the room air temperature and the air discharged by the unit.
  • In the HEAT operation, water vapour may flow out of the outdoor unit during de-icing.

UNIT DOES NOT SEND OUT WARM AIR The unit is preheating or de-icing.

THE OUTDOOR UNIT DOES NOT STOP After stopping the operation, the outdoor unit will rotate its' fan for about a minute to cool down the unit.

ODORS Carpet and furniture odors that entered into the unit and the air conditioner's inner component odors at the early stage of installation may be sent out from the unit.

  • UNIT DOES NOT OPERATE IN YOUR REQUESTED MODE
  • When one indoor unit is operating in COOL or DRY mode, you can not operate the other unit in HEAT mode. (4 seconds later, a long BEEP will be emitted, and the temperature indicator on the indicator panel will indicate " " and the OPERATION lamp and TIMER lamp will blink alternately.)
  • When one indoor unit is operating in HEAT mode, you can not operate the other unit in COOL nor DRY mode. (4 seconds later, a long BEEP will be emitted, and the temperature indicator on the indicator panel will indicate " " and the OPERATION lamp and TIMER lamp will blink alternately.)

CRACKING NOISE The unit may produce a cracking noise. This sound is generated by the friction of the front panel and other components expanding or connecting due to a temperature change.

SWISHING NOISE The soft, swishing noise is the sound of the refrigerant flowing inside the unit.

INDOOR UNIT BECOMES WARM EVEN WHEN IDLE This is because the refrigerant also flows through the idle indoor unit's pipes when the other unit is operated in HEAT mode.

(only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR)

ODOR EMITTED FROM THE PLASMACLUSTER AIR OUTLET This is the smell of ozone generated from the ionizer. Density of the ozone is very little, having no adverse effect over your health. The ozone released into the air will decompose soon, and its density in the room will not increase.

A LOW BUZZ NOISE EMITTED This is a sound emitted when the unit is generating cluster ions.

UNIT DOES NOT SEND OUT AIR (PLASMACLUTER operation without accompanying air conditioning mode, SELF CLEAN operation) • The other unit(s) is/are de-icing.

INDOOR UNIT BECOMES WARM EVEN WHEN NOT DURING HEATING OPERATION When the PLASMACLUSTER button is pressed while the unit is not operating, the PLASMACLUSTER operation will be performed without accompanying air conditioning mode (eg. HEATING or COOLING) . At this time, you may feel warm air coming out from the unit air outlet if HEATING is performed with units in other rooms. Indoor fan will decrease its rotating speed and will turn ON and OFF depending on the room temperature.

During PLASMACLUSTER AUTO OPERATION, the air conditioner operates in the REFRESHING OPERA- TION even when there is odor in the room.

  • In case for example, when the room is full of tobacco smokes before the air conditioner is turned on, the ODOR SENSOR may become unreactive.
Page 25 of the Sharp AE-XM18CR user manual — IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL
Page 25 · cliquer pour agrandir
Page 25

If the unit appears to be malfunctioning, check the following points before calling for service.

IF THE UNIT FAILS TO OPERATE

Check to see if the circuit breaker has tripped or the fuse has blown.

IF THE UNIT FAILS TO COOL (OR HEAT) THE ROOM EFFECTIVELY

Check the filters. If dirty, clean them.

Check the outdoor unit to make sure nothing is blocking the air inlet or outlet.

Check the thermostat is proper setting.

Make sure windows and doors are closed tightly.

A large number of people in the room can prevent the unit from achieving the desired temperature.

Check whether any heat- generating appliances are operating in the room.

IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL

Check whether the remote control batteries have be- come old and weak.

Try to send the signal again with the remote control pointed properly towards the unit’s sig- nal receiver window.

Check whether the remote control batteries are in- stalled with the polarities properly aligned.

Please call for service when OPERATION Lamp, TIMER Lamp and TEMPERATURE INDICATOR on the indicator panel blink.

Page 26 of the Sharp AE-XM18CR user manual — IF THE UNIT FAILS TO OPERATE
Page 26 · cliquer pour agrandir
Page 26
Page 26 of the Sharp AE-XM18CR user manual — IF THE UNIT FAILS TO OPERATE

Poser une question sur : Sharp AE-XM18CR

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Sharp AE-XM18CR

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Sharp AE-XM18CR manuel PDF

219 pages·9.6 MB·Climatiseur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…