FR
Sharp logo
Notice d'utilisation officielle

Sharp Air Conditioner (AY-XPC7JR)

116 pages·5.1 MB·Climatiseur·PDF·ENNLJA
Sharp Air Conditioner (AY-XPC7JR)
Table des matières 20 sections ENGLISH · CONTENTS · IMPORTANT SAFETYINSTRUCTIONS · PART NAMES · … AfficherMasquer
Page 1 of the Sharp Air Conditioner (AY-XPC7JR) user manual — PORTUGUÊS
Page 1 · cliquer pour agrandir
Page 1
Sharp Air Conditioner (AY-XPC7JR) diagram (page 1)
Fig. 1

SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

Sharp Air Conditioner (AY-XPC7JR) — SPLIT TYPE ROOM AIR CONDITIONER diagram (page 1)
Fig. 2

CLIMATISEUR INDIVIDUEL EN DEUX PARTIES

FRANÇAIS ESPAÑOL ITALIANO DEUTSCH EΛΛΗΝΙΚΑ

MODE D'EMPLOI

ACONDICIONADOR DE AIRE DE DOBLE SERVICIO

MANUAL DE INSTRUCCIONES

CONDIZIONATORE D'ARIA DA CAMERA TIPO SPLIT

MANUALE DI ISTRUZIONI

ZWEITEILIGES KLIMAGERÄT

BEDIENUNGSANLEITUNG

ΑΙΡΚΟΝΤΙΣΙΟΝ ΔΩΜΑΤΙΟΥ ΤΥΠΟΥ SPLIT

ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ

Sharp Air Conditioner (AY-XPC7JR) — FRANÇAIS ESPAÑOL ITALIANO DEUTSCH EΛΛΗΝΙΚΑ diagram (page 1)
Fig. 3

AR CONDICIONADO DE SALA DE DUAS UNIDADES

PORTUGUÊS

MANUAL DE OPERAÇÃO

Device of this mark is a trademark of Sharp Corporation. Plasmacluster is a registered trademark or a trademark of Sharp Corporation.

Page 2 of the Sharp Air Conditioner (AY-XPC7JR) user manual — Pb
Page 2 · cliquer pour agrandir
Page 2

A. Information on Disposal for Users (private households) 1. In the European Union Attention: If you want to dispose of this equipment, please do not use the ordinary dust bin! Used electrical and electronic equipment must be treated separately and in accordance with legislation that requires proper treatment, recovery and recycling of used electrical and electronic equipment. Following the implementation by member states, private households within the EU states may return their used electrical and electronic equipment to designated collection facilities free of charge*. In some countries* your local retailer may also take back your old product free of charge if you purchase a similar new one. *) Please contact your local authority for further details. If your used electrical or electronic equipment has batteries or accumulators, please dispose of these separately beforehand according to local requirements. By disposing of this product correctly you will help ensure that the waste undergoes the necessary treatment, recovery and recycling and thus prevent potential negative effects on the environment and human health which could otherwise arise due to inappropriate waste handling. 2. In other Countries outside the EU If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal. For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you don’t purchase a new product. Further collection facilities are listed on the homepage of www.swico.ch or www.sens.ch

B. Information on Disposal for Business Users. 1. In the European Union If the product is used for business purposes and you want to discard it: Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities. For Spain: Please contact the established collection system or your local authority for take-back of your used products. 2. In other Countries outside the EU If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.

The battery supplied with this product contains traces of Lead. For EU: The crossed-out wheeled bin implies that used batteries should not be put to the general household waste! There is a separate collection system for used batteries, to allow proper treatment and recycling in accordance with legislation. Please contact your local authority for details on the collection and recycling schemes. For Switzerland: The used battery is to be returned to the selling point. For other non-EU countries: Please contact your local authority for correct method of disposal of the used battery.

Pb

Contains fl uorinated greenhouse gases covered by the Kyoto Protocol R410A (Global warming potential 1980)

Page 4 of the Sharp Air Conditioner (AY-XPC7JR) user manual — 12 TEMPERATURE INDICATOR
Page 4 · cliquer pour agrandir
Page 4

PART NAMES

INDOOR UNIT

Sharp Air Conditioner (AY-XPC7JR) — INDOOR UNIT diagram (page 4)
Fig. 4

4 Air Purifying Filter

7 Vertical Adjustment Louvre

8 Horizontal Adjustment Louvre

Sharp Air Conditioner (AY-XPC7JR) — INDOOR UNIT diagram (page 4)
Fig. 5

11 PLASMACLUSTER Lamp (blue)

12 TEMPERATURE INDICATOR

13 OUTDOOR Temp. Lamp (green )

14 ROOM Temp. Lamp (green )

15 FULL POWER Lamp (green )

16 TIMER Lamp (orange )

17 OPERATION Lamp (red )

Show 7 more labels / short text on this page
1 AUX Button · 2 Inlet (Air) · 3 Open Panel · 5 Air Filters · 6 Receiver Window · 9 Outlet (Air) · 10 Remote Control
Page 5 of the Sharp Air Conditioner (AY-XPC7JR) user manual — : AUTO : LOW
Page 5 · cliquer pour agrandir
Page 5

REMOTE CONTROL

1 TRANSMITTER

Sharp Air Conditioner (AY-XPC7JR) — REMOTE CONTROL diagram (page 5)
Fig. 6

2 DISPLAY (Liquid Crystal Display)

7 FULL POWER Button

8 PROGRESSIVE AIRFLOW Button

10 TIMER ON Button (for setting the timer)

11 TIMER OFF Button (for setting the timer)

12 ONE-HOUR OFF TIMER Button

13 TIME ADVANCE Button

14 TIME REVERSE Button

15 SELF CLEAN Button

12 13 14 15 16 17 18 19 20

16 TIMER SET/CANCEL Button

17 Indicates battery compartment is below this mark

21 PROGRESSIVE AIRFLOW Symbol 22 SELF CLEAN Symbol 23 PLASMACLUSTER Symbol 24 MODE Symbols : AUTO : COOL

: HEAT : DRY

25 Thermostat setting for AUTO and DRY modes 26 TEMPERATURE Indicator 27 TRANSMITTING Symbol 28 FULL POWER Symbol 29 FAN SPEED Symbols

: AUTO : LOW

: HIGH : SOFT

30 TIMER ON Indicator/CLOCK Indicates the on timer preset time or current time. 31 TIMER OFF Indicator Indicates the preset time for off timer or one-hour off

timer.

Show 8 more labels / short text on this page
3 PLASMACLUSTER Button · 4 DISPLAY Button · 5 ON/OFF Button · 6 THERMOSTAT Button · 9 MODE Button · 18 CLOCK Button · 19 FAN Button · 20 SWING Button
Page 6 of the Sharp Air Conditioner (AY-XPC7JR) user manual — SET CURRENT CLOCK TIME
Page 6 · cliquer pour agrandir
Page 6

USING THE REMOTE CONTROL

LOADING BATTERIES

  • CAUTION:
  • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light.
  • Using a fl uorescent lamp with a quick starter in the same room may interfere with transmission of the signal.
  • The unit can be affected by signals transmitted from the remote control of a television, VCR or other equipment used in the same room.
  • Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit and remote control from moisture and shock which can discolour or damage them.

Use two size-AAA (R03) batteries. 1 Remove the remote control cover. 2 Insert batteries in the compartment,

Sharp Air Conditioner (AY-XPC7JR) — LOADING BATTERIES diagram (page 6)
Fig. 7

making sure the (+) and (-) polarities are correctly a lign ed. • The display indicates “AM 6:00” when batteries are properly installed. 3 Reinstall the cover.

SET CURRENT CLOCK TIME

There are two clock modes: 12-hour mode and 24-hour mode.

Example5 o’clock in the afternoon
ClockDisplay 12-hour modePM 5:00 24-hour mode17:00
Sharp Air Conditioner (AY-XPC7JR) — SET CURRENT CLOCK TIME diagram (page 6)
Fig. 8
  • NOTE:
  • The battery life is approximately one year in normal use.
  • When you replace the batteries, always change both batteries, and make sure they are the same type.
  • If the remote control does not operate properly after replacing the batteries, take out the batteries and reinstall them again after 30 seconds.
  • If you will not be using the unit for a long time, remove the batteries from the remote control.

To set to the 24-hour mode, press the CLOCK button twice in the fi rst step. 2 Press the TIME ADVANCE or REVERSE

  • button to set the current time.
  • Keep the button pressed to advance or reverse the time display quickly. 3 Press the SET/C button.
  • The colon (:) blinks to indicate that the clock is functioning.
  • HOW TO USE THE REMOTE CONTROL Point the remote control towards the unit’s signal receiver window and press the desired button. The unit generates a beep when it receives the signal.
  • Make sure there is no curtain or other object between the remote control and the unit.
  • The remote control can send signals from up to 7 metres away.
Page 7 of the Sharp Air Conditioner (AY-XPC7JR) user manual — AUX
Page 7 · cliquer pour agrandir
Page 7

SETTING AIR PURIFYING FILTER

TIPS ON SAVING ENERGY

The air purifying filters are packed as accessory of this unit. During operation of the air conditioner, the filters remove dust and tobacco smoke from the air and discharges clean air. 1 Take out the air fi lters. 1 Open the open panel. 2 Push the air filters up slightly to unlock

Below are some simple ways to save energy when you use your air conditioner.

  • SET THE CORRECT TEMPERATURE
  • Setting the thermostat 1°C higher than the desired temperature in the COOL mode and 2°C lower in the HEAT mode will save approximately 10 percent in power consumption.
  • Setting the temperature lower than necessary during cooling operation will result in increased power consumption.
Sharp Air Conditioner (AY-XPC7JR) — SETTING AIR PURIFYING FILTER diagram (page 7)
Fig. 9

them. 3 Pull the air fi lters down to remove them.

  • BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS
  • Blocking direct sunlight during cooling operation will reduce power consumption.
  • Close the windows and doors during cooling and heating operations.

SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR CIRCULATION

KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION

2 Set the air purifying fi lter under the fi lter

MAKE MOST OF THE TIMER OFF FUNCTION

stoppers located on the air fi lter.

DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN EXTENDED PERIOD OF TIME • The indoor unit still consumes a small amount of power when it is not operating.

Sharp Air Conditioner (AY-XPC7JR) — MAKE MOST OF THE TIMER OFF FUNCTION diagram (page 7)
Fig. 10

AUXILIARY MODE

Use this mode when the remote control is not available.

  • TO TURN ON Lift the open panel of the indoor unit and press the AUX. button.
  • The red OPERATION lamp ( ) on the unit will light and the unit will start operating in the AUTO mode.
  • The fan speed and temperature setting are set to AUTO.

3 Reinstall the air fi lters. 1 Reinstall the air fi lters in the original posi-

tions. 2 Close the open panel. 3 Push the arrow-marked of the panel fi rmly

to lock it in place.

TO TURN OFF Press the AUX. button again. • The red OPERATION lamp ( ) on the unit will turn off.

Sharp Air Conditioner (AY-XPC7JR) — AUXILIARY MODE diagram (page 7)
Fig. 11
Sharp Air Conditioner (AY-XPC7JR) — AUXILIARY MODE diagram (page 7)
Fig. 12

AUX

Precautions: • The fi lters are sealed in a plastic bag to keep their dust collection effect. Do not open the bag until using the filters.

(Otherwise the fi lters life may get shorter.) • Do not expose the filters to direct sunlight. (Otherwise they may deteriorate.)

Filter stopper · Air fi lter

Page 8 of the Sharp Air Conditioner (AY-XPC7JR) user manual — 5 To turn off the unit, press the ON/OFF
Page 8 · cliquer pour agrandir
Page 8

BASIC OPERATION

1 Press the MODE button to select the

Sharp Air Conditioner (AY-XPC7JR) — BASIC OPERATION diagram (page 8)
Fig. 13

operation mode.

AUTO HEAT COOL DRY

2 5 3 1

2 Press the ON/OFF button to start

operation. • The red OPERATION lamp ( ) on the unit will light.

3 Press the THERMOSTAT button to set

the desired temperature.

AUTO/DRY MODE • The temperature can be changed in 1°C incre- ments within the range of 2°C higher to 2°C lower from the temperature automatically deter- mined by the air conditioner.

(Example1°C higher)
(Example2°C lower)

COOL/HEAT MODE • The temperature can be set within the range of 18 to 32°C.

4 Press the FAN button to set the desired

fan speed.

AUTO SOFT LOW HIGH

  • In the DRY mode, the fan speed is preset to AUTO and cannot be changed.

5 To turn off the unit, press the ON/OFF

button again. • The red OPERATION lamp ( ) on the unit will turn off.

Page 9 of the Sharp Air Conditioner (AY-XPC7JR) user manual — When using your air-conditioner with multi-system
Page 9 · cliquer pour agrandir
Page 9

ADJUSTING THE AIR FLOW DIRECTION

Sharp Air Conditioner (AY-XPC7JR) — ADJUSTING THE AIR FLOW DIRECTION diagram (page 9)
Fig. 14

When using your air-conditioner with multi-system

  • With a multi system air conditioner, multiple indoor units can be connected to one outdoor unit. When the setting mode differs among indoor unit(s), the indoor unit(s) operated later may not work.
  • When the indoor unit(s) is/are operating in HEAT mode, the remaining unit(s) can not operate in COOL or DRY mode.
  • When the indoor unit(s) is/are operating in COOL or DRY mode, the remaining unit(s) can not operate in HEAT mode. When the mode of the indoor unit(s) later operated is/are different from those which is/are in operation, after a few seconds, a long BEEP will be emitted and the temperature indicator on the indicator panel will indicate” ” and the OPERATION lamp and TIMER lamp will blink alternately. This shows that the later operated unit(s) is/are not working. In such case, change the mode to the same mode which the other indoor unit(s) is/are operating in.

control once. • The vertical adjustment louvres will swing continuously. 2 Press the SWING button again when the

Sharp Air Conditioner (AY-XPC7JR) — When using your air-conditioner with multi-system diagram (page 9)
Fig. 15 · When using your air-conditioner with multi-system

In the AUTO mode, the temperature setting and mode are automatically selected accord- ing to the room temperature and outdoor temperature when the unit is turned on. • During operation, if the outdoor tempera- ture changes, the temperature settings will automatically slide as shown in the chart.

The fi gures in ( ) are temperature settings

Hold the horizontal adjustment louvre as shown in the diagram and adjust the air fl ow direction.

  • When using your air-conditioner with multisystem, mode of the unit operated first will have priority over other unit(s) without reference to the above chart.
  • CAUTION: Never attempt to adjust the vertical adjustment louvres manually.
  • Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction when the remote control is used for adjustment.
  • When the vertical adjustment louvre is positioned at the lowest position in the COOL or DRY mode for an extended period of time, condensation may result. Do not adjust the horizontal adjustment louvre to the extreme left or right in the COOL mode with the fan speed set to “SOFT ( )” for an extended period of time. Condensation may form on the louvres.
Page 10 of the Sharp Air Conditioner (AY-XPC7JR) user manual — PROGRESSIVE AIRFLOW FULL POWER OPERATION
Page 10 · cliquer pour agrandir
Page 10

PROGRESSIVE AIRFLOW FULL POWER OPERATION

Press the PROGRESSIVE AIRFLOW button during cooling or dry operation when you do not want to feel cold air. Vertical adjustment louvre is set obliquely upward to deliver cool air to the ceiling. Press the button during heating operation. Vertical adjustment louvre is set downward to deliver the warm air down to the fl oor and warm you. 1 During operation, press the

In this operation, the air conditioner works at the maximum power to makes the room cool or warm so rapidly that you can use it just after you come home. 1 To activate the FULL POWER operation,

  • press the FULL POWER button during operation.
  • The remote control will display “ ”.
  • The temperature display will go off.
  • The green FULL POWER lamp ( ) on the unit will light up.

PROGRESSIVE AIRFLOW button.

Sharp Air Conditioner (AY-XPC7JR) — PROGRESSIVE AIRFLOW FULL POWER OPERATION diagram (page 10)
Fig. 16
Sharp Air Conditioner (AY-XPC7JR) — PROGRESSIVE AIRFLOW FULL POWER OPERATION diagram (page 10)
Fig. 17
  • TO CANCEL Press the FULL POWER button again.
  • FULL POWER operation will also be cancelled when the operation mode is changed, or when the unit is turned off.
  • The green FULL POWER lamp ( ) on the unit will turn off.
  • NOTE:
  • The PROGRESSIVE AIRFLOW setting is cancelled when you press FULL POWER button while PROGRESSIVE AIRFLOW is set.
  • If you want PROGRESSIVE AIRFLOW operation in FULL POWER mode, press PROGRESSIVE AIRFLOW button during FULL POWER operation.
Page 11 of the Sharp Air Conditioner (AY-XPC7JR) user manual — PLASMACLUSTER OPERATION
Page 11 · cliquer pour agrandir
Page 11

PLASMACLUSTER OPERATION

SELF CLEAN OPERATION

The Plasmacluster Ion generator inside the air conditioner will release positive and negative plasmacluster ions into the room. Approximately the same numbers of positive and negative ions released into the air will reduce some airborne mold. 1 During operation, press the

SELF CLEAN operation will reduce the growth mold fungus with Plasmacluster ions, and dry inside of the air conditioner unit. Utilize the operation at seasonal change over terms. Mold fungus already grown can not be eliminated by this operation. 1 Press the SELF CLEAN button when the

  • PLASMACLUSTER button.
  • The remote control will display “ ”.
  • The blue PLASMACLUSTER lamp on the unit will light up.
  • unit is not operating.
  • The remote control displays “ ”.
  • The blue PLASMACLUSTER lamp on the unit will light up.
  • The unit will stop operation after forty minutes.
  • The remaining operation time will be indicated on the TEMPERATURE INDICATOR of the indoor unit in minute decrements.
Sharp Air Conditioner (AY-XPC7JR) — PLASMACLUSTER OPERATION diagram (page 11)
Fig. 18
Sharp Air Conditioner (AY-XPC7JR) — PLASMACLUSTER OPERATION diagram (page 11)
Fig. 19

TO CANCEL Press the PLASMACLUSTER button again. • The PLASMACLUSTER lamp on the unit will turn off.

TO CANCEL Press the SELF CLEAN button. Alternatively, turn the unit off by pressing the ON/OFF button. • The blue PLASMACLUSTER lamp on the unit will turn off.

  • NOTE:
  • Use of the PLASMACLUSTER operation will be memorized, and it will be activated the next time you turn on the air conditioner.
  • To turn off the PLASMACLUSTER lamp, press the DISPLAY button.
  • To perform the PLASMACLUSTER operation without accompanying heat, cool or dry mode, press the PLASMACLUSTER button while the unit is not operating. The mode symbol of the remote control will go off and the fan speed can not be set AUTO.
Page 12 of the Sharp Air Conditioner (AY-XPC7JR) user manual — CANCEL
Page 12 · cliquer pour agrandir
Page 12

ONE-HOUR OFF TIMER

TIMER OPERATION

TIMER OFF 1 Press the TIMER OFF ( ) button.

When the ONE-HOUR OFF TIMER is set, the unit will automatically turn off after one hour. 1 Press the ONE-HOUR OFF TIMER

  • button.
  • The remote control displays “ ”.
  • The orange TIMER lamp ( ) on the unit will light up.
  • The unit will stop operating after one hour.

2 The TIMER OFF indicator will blink;

press the TIME ADVANCE or REVERSE button to set the desired time. (The time can be set in 10-minute increments.) 3 Point the remote control at the receiver

  • window on the unit and press the TIMER SET (SET/C) button.
  • The orange TIMER lamp ( ) on the unit will light.
  • The unit will generate a beep when it receives the signal.
Sharp Air Conditioner (AY-XPC7JR) — 2 The TIMER OFF indicator will blink; diagram (page 12)
Fig. 20 · 2 The TIMER OFF indicator will blink;
Sharp Air Conditioner (AY-XPC7JR) — 2 The TIMER OFF indicator will blink; diagram (page 12)
Fig. 21 · 2 The TIMER OFF indicator will blink;

CANCEL

TO CANCEL Press the TIMER CANCEL (SET/C) button. • The orange TIMER lamp ( ) on the unit will turn off.

Alternatively, turn the unit off by pressing the ON/OFF button. • The red OPERATION lamp ( ) and the orange TIMER lamp ( ) on the unit will turn off.

  • NOTE:
  • The ONE-HOUR OFF TIMER operation has priority over TIMER ON and TIMER OFF operations.
  • If the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit will operate for an hour at the formerly set condition.
  • If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER is activated, press the ONE-HOUR OFF TIMER button again during operation.
  • If TIMER ON and/or TIMER OFF are set, TIMER CANCEL button cancels every setting.

COOL/DRY MODE: • One hour after the time operation begins, the temperature setting rises 1°C higher than the original temperature setting.

HEAT MODE: • One hour after the timer operation begins, the temperature setting drops 3°C lower than the original temperature setting.

Page 13 of the Sharp Air Conditioner (AY-XPC7JR) user manual — 2 The TIMER ON indicator will blink;
Page 13 · cliquer pour agrandir
Page 13

Before setting the timer, make sure the clock is properly set with the current time.

TIMER ON 1 Press the TIMER ON ( ) button.

TO CANCEL TIMER MODE

  • Press the TIMER CANCEL (SET/C) button.
  • The orange TIMER lamp ( ) on the unit will turn off.
  • The current clock time will be displayed on the remote control.

2 The TIMER ON indicator will blink;

press the TIME ADVANCE or REVERSE button to set the desired time.

(The time can be set in 10-minute increments.) 3 Point the remote control at the receiver

Sharp Air Conditioner (AY-XPC7JR) — 2 The TIMER ON indicator will blink; diagram (page 13)
Fig. 22 · 2 The TIMER ON indicator will blink;
  • window on the unit and press the TIMER SET (SET/C) button.
  • The orange TIMER lamp ( ) on the unit will light.
  • The unit will generate a beep when it receives the signal. 4 Select the operation condition.
Sharp Air Conditioner (AY-XPC7JR) — 2 The TIMER ON indicator will blink; diagram (page 13)
Fig. 23 · 2 The TIMER ON indicator will blink;

Cancel the TIMER setting fi rst, then set it again.

COMBINED USE OF ON AND OFF TIMERS You can use the ON and OFF timers in combination.

Example: To stop operation at 11:00 p.m. and resume operation to bring the room temperature to the desired level by 7:00 a.m. 1 Set the TIMER OFF to 11:00 p.m. during

operation. 2 Set the TIMER ON to 7:00 a.m.

The arrow ( or ) between the TIMER ON indicator and the TIMER OFF indicator shows which timer will activate fi rst.

Sharp Air Conditioner (AY-XPC7JR) — 2 The TIMER ON indicator will blink; diagram (page 13)
Fig. 24 · 2 The TIMER ON indicator will blink;
  • NOTE:
  • You cannot programmed the ON-TIMER and OFF-TIMER to operate the unit at different temperatures or other settings.
  • Either timer can be programmed to activate prior the other.
Page 14 of the Sharp Air Conditioner (AY-XPC7JR) user manual — CLEANING THE UNIT AND THE REMOTE CONTROL
Page 14 · cliquer pour agrandir
Page 14

TIPS ABOUT INDICATOR PANEL

MAINTENANCE

The indicator panel will change each time you press the DISPLAY button in the fol- lowing manner.

Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance.

CLEANING THE FILTERS

The air fi lters should be cleaned every two weeks. 1 Turn off the unit. 2 Remove the fi lters.

1 Lift the open panel. 2 Push the air filters up slightly to unlock

them. 3 Pull the air fi lters down to remove them.

The room temperature is displayed.

3 Take off the air purifying fi lters from the

The outdoor temperature is displayed.

air fi lters. 4 Clean the fi lters.

Use a vacuum cleaner to remove dust. If the fi lters are dirty, wash them with warm water and a mild detergent. Dry fi lters in the shade before reinstalling.

No display.

5 Reinstall the air purifying fi lters. 6 Reinstall the fi lters.

  • NOTES:
  • The displayed temperatures are rough estimates and may vary from the actual temperatures.
  • Temperature display ranges Room temperature: 0°C ~ 40°C ( is displayed when less than 0°C and when higher than 40° C) Outdoor temperature: –9°C ~ 45°C ( is displayed when less than –9°C and when higher than 45°C)
  • is displayed during the first about 0~120 seconds of operation while the temperatures are being detected.
  • During SELF CLEAN operation, the indicator panel will display remaining time of the operation. Room and outdoor temperature will not be displayed even if you press the DISPLAY button.

1 Reinstall the fi lters in the original positions. 2 Close the open panel. 3 Push the arrow-marked of the panel fi rmly

Sharp Air Conditioner (AY-XPC7JR) — 3 Take off the air purifying fi lters from the diagram (page 14)
Fig. 25 · 3 Take off the air purifying fi lters from the

CLEANING THE UNIT AND THE REMOTE CONTROL

Single use • Only the room temperature can be displayed for 5 seconds when the unit is not in operation.

  • Wipe them with a soft cloth.
  • Do not directly splash or pour water on them. It can cause electrical shock or equipment damage.
  • Do not use hot water, thinner, abrasive powders or strong solvents.

Multi use • is displayed for 5 seconds when the unit is not in operation.

Page 15 of the Sharp Air Conditioner (AY-XPC7JR) user manual — CHANGING THE AIR PURIFYING FILTER
Page 15 · cliquer pour agrandir
Page 15

ADDITIONAL NOTES ON OPERATION

MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Operate the unit in the SELF CLEAN

OPERATING TEMPERATURE RANGE

Sharp Air Conditioner (AY-XPC7JR) — OPERATING TEMPERATURE RANGE diagram (page 15)
Fig. 26

upper limit 32˚C 46˚C (Single use) 43˚C (Multi use)

operation to allow the mechanism to thoroughly dry. 2 Stop the operation and unplug the unit.

lower limit 21˚C –10˚C (Single use) 21˚C (Multi use)

Turn off the circuit breaker, if you have one exclusively for the air conditioner. 3 Clean the fi lters, then reinstall them.

  • The built-in protective device may prevent the unit from operating when used out of this range.
  • Condensation may form on the air outlet if the unit operates continuously in the COOL or DRY mode when humidity is over 80 percent.

MAINTENANCE BEFORE AIR CONDITIONER SEASON 1 Make sure that the air fi lters are not dirty. 2 Make sure that nothing obstructs the

WHEN POWER FAILURE OCCURS This air conditioner has a memory function to store settings when a power failure occurs. After power recovery, the unit will automatically re- start in the same settings which were active before the power failure, except for timer settings. If the timers were set before a power failure, they will need to be re-set after power recovery.

air inlet or outlet.

CHANGING THE AIR PURIFYING FILTER

PREHEATING FUNCTION In the HEAT operation, the indoor fan may not start for two to fi ve minutes after the unit is turned on to prevent cold air from blowing out of the unit.

The fi lters should be changed every 3 ~ 6 months 1 Remove the air fi lters. 2 Change the air purifying fi lters.

  • DE-ICING FUNCTION
  • When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an automatic de-icer provides heat for about 5 to 10 minutes to remove the ice. During de-icing, the inside and outside fans stop operating.
  • After de-icing is completed, the unit automatically resumes operation in the HEAT mode.

1 Take off the old air purifying fi lters from the

air fi lters. 2 Set the new air purifying fi lters, under the

fi lter stoppers located on the air fi lters.

  • HEATING EFFICIENCY
  • The unit employs a heat pump that draws heat from the outside air and releases it into the room. The outside air temperature therefore greatly affects the heating effi ciency.
  • If the heating effi ciency is reduced due to low outside temperatures, use an additional heater.
  • It takes time to warm up and heat the entire room because of the forced air circulation system.

3 Reinstall the air fi lters.

Replacement fi lterType AZ-F920F

Disposal of Filters Please dispose of replaced fi lters according to the local disposal laws and regulations.

AIR PURIFYING fi lter materials Filter:Polypropylene Frame:Polyester

Filter stopper

Page 16 of the Sharp Air Conditioner (AY-XPC7JR) user manual — BEFORE CALLING FOR SERVICE
Page 16 · cliquer pour agrandir
Page 16

BEFORE CALLING FOR SERVICE

The following conditions do not denote equip- ment malfunctions

  • UNIT DOES NOT OPERATE IN YOUR REQUESTED MODE
  • When one indoor unit is operating in COOL or DRY mode, you can not operate the other unit in HEAT mode. (After a few seconds, a long BEEP will be emitted, and the temperature indicator on the indicator panel will indicate” ” and the OPERATION lamp and TIMER lamp will blink alternately.)
  • When one indoor unit is operating in HEAT mode, you can not operate the other unit in COOL nor DRY mode. (After a few seconds, a long BEEP will be emitted, and the temperature indicator on the indicator panel will indicate” ” and the OPERATION lamp and TIMER lamp will blink alternately.)

UNIT DOES NOT OPERATE The unit will not operate if it is turned on immediately after it is turned off. The unit will not operate immediately after the mode is changed. This is to protect the internal mechanisms. Wait 3 minutes before operating the unit.

UNIT DOES NOT SEND OUT WARM AIR The unit is preheating or de-icing.

ODORS Carpet and furniture odors that entered into the unit may be sent out from the unit.

CRACKING NOISE The unit may produce a cracking noise. This sound is generated by the friction of the front panel and other components expanding or connecting due to a temperature change.

UNIT DOES NOT SEND OUT AIR (PLASMACLUSTER operation without accompanying air conditioning mode, SELF CLEAN operation) The other unit(s) is/are de-icing.

A LOW BUZZING NOISE EMITTED This is a sound emitted when the unit is generating Plasmacluster ions.

If the unit appears to be malfunctioning, check the following points before calling for service.

IF THE UNIT FAILS TO OPERATE Check to see if the circuit breaker has tripped or the fuse has blown.

SWISHING NOISE The soft, swishing noise is the sound of the refrigerant fl owing inside the unit.

  • IF THE UNIT FAILS TO COOL (OR HEAT) THE ROOM EFFECTIVELY
  • Check the fi lters. If dirty, clean them.
  • Check the outdoor unit to make sure nothing is blocking the air inlet or outlet.
  • Check the thermostat is proper setting.
  • Make sure windows and doors are closed tightly.
  • A large number of people in the room can prevent the unit from achieving the desired temperature.
  • Check whether any heat-generating appliances are operating in the room.
  • WATER VAPOUR
  • In the COOL and DRY operation, water vapour can sometimes be seen at the air outlet due to the difference between the room air temperature and the air discharged by the unit.
  • In the HEAT operation, water vapour may fl ow out of the outdoor unit during de-icing.

THE OUTDOOR UNIT DOES NOT STOP After stopping the operation, the outdoor unit will rotate its' fan for about a minute to cool down the unit.

ODOR EMITTED FROM THE PLASMACLUSTER AIR OUTLET This is the smell of ozone generated from the Plasmacluster Ion generator. The ozone concentration is very small, posing no adverse effect on your health. The ozone discharged into the air rapidly decomposes, and its density in the room will not increase.

  • IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL
  • Check whether the remote control batteries have become old and weak.
  • Try to send the signal again with the remote control pointed properly towards the unit’s signal receiver window.
  • Check whether the remote control batteries are installed with the polarities properly aligned.

When using your air conditioner with multi- system

Please call for service when TEMPERATURE INDICATOR on the indicator panel blink.

INDOOR UNIT BECOMES WARM EVEN WHEN IDLE This is because the refrigerant also fl oes through the idle indoor unit's pipes when the other unit is operated in HEAT mode.

INDOOR UNIT BECOMES WARM EVEN WHEN NOT DURING HEATING OPERATION When the PLASMACLUSTER button is pressed while the unit is not operating, the PLASMACLUSTER operation will be performed without accompanying air conditioning mode (eg. HEATING or COOLING). At this time, you may feel warm air coming out from the unit air outlet if HEATING is performed with units in other rooms. Indoor fan will decrease its rotating speed and will turn ON and OFF depending on the room temperature.

Page 17 of the Sharp Air Conditioner (AY-XPC7JR) user manual — BEFORE CALLING FOR SERVICE
Page 17 · cliquer pour agrandir
Page 17
Page 17 of the Sharp Air Conditioner (AY-XPC7JR) user manual — BEFORE CALLING FOR SERVICE
Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Sharp Air Conditioner (AY-XPC7JR)

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Sharp Air Conditioner (AY-XPC7JR)

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Sharp Air Conditioner (AY-XPC7JR) manuel PDF

116 pages·5.1 MB·Climatiseur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…