Page 1 of the Pico Technology Diagnostics Kit user manual — 2 Kit Contents
Page 1 · cliquer pour agrandir
Page 1

1 Introduction

The Pico Technology Oscilloscope Diagnostics Kits are based on our PicoScope 3000 Series Automotive PC Oscilloscopes and include our own automotive-specific software. The PC Oscilloscope turns a laptop or desktop PC into a powerful automotive diagnostic tool for fault-finding the increasing number of sensors, actuators and electronic circuits found on today’s vehicles.

This manual is a quick start guide which lists the products in the kit and shows you how to make your first measurements using the Pico Oscilloscope Diagnostics Kit.

For further information, you can consult the PicoScope 3000 Series Automotive user guide which contains detailed information about using the product and its software. It includes all the information you will need to connect and set up your product. The user guide is installed in electronic Windows Help format, but if you would prefer a paper copy, you can print the PDF file listed under ‘User Manuals’ on the CD-ROM.

2 Kit Contents

The Oscilloscope Diagnostics Kit is available in three versions: two-channel (PP280), four-channel (PP276) and commercial (PP286). The number of accessories varies between the versions, as shown below.

Contents Packed in the Base of the UnitPart numberQty PP280Qty PP276Qty PP286 PicoScope 3223 two-channel PC OscilloscopePP279100 PicoScope 3423 four-channel PC OscilloscopePP277011 USB cableMI106111 60 A DC current clampPP264111 600 A AC/DC current clampPP266110 2000 A DC / 1500 A AC current clampPP253001 20:1 attenuatorPP198244
Pico Technology Diagnostics Kit — 2 Kit Contents diagram (page 1)
Fig. 1 · 2 Kit Contents
Page 2 of the Pico Technology Diagnostics Kit user manual — 1 Introduction
Page 2 · cliquer pour agrandir
Page 2
Pico Technology Diagnostics Kit — 1 Introduction diagram (page 2)
Fig. 2 · 1 Introduction
Contents Packed in the Base of the Unit (continued)Part numberQty PP280Qty PP276Qty PP286 Multimeter probe (black)TA001124 Multimeter probe (red)TA002124 Small croc clip (black)TA003122 Small croc clip (red)TA004122 Dolphin clip (black)TA005111 Dolphin clip (red)TA006111 Insulation-piercing probes (pack of 2)TA007110 Acupuncture probe setTA008111 Contents Packed in the Lid of the Unit Test leadTA000244 Cable ID kitTA030111 Secondary ignition pickup leadPP178242 Two-pin break-out leadTA012111 S-hookMI168111 Automotive software CDDI028111 Introductory Video CDDI047111 Automotive Quick Start GuideDO110111 Carry casePP207111
Page 3 of the Pico Technology Diagnostics Kit user manual — 3 Installation Guide
Page 3 · cliquer pour agrandir
Page 3

3 Installation Guide

3.1 Installing the software

The PicoScope Automotive software has been designed to run on computers with Windows XP SP2 and Vista.

1. Insert the Pico CD into your CD-ROM drive. If Autorun is enabled then the CD will start up automatically, and you can go to step 5. 2. Press the Start button and select Run . 3. Type d:\index (where d: is your CD-ROM drive). 4. Press the Enter key. 5. Click the Software button. 6. Click the Install PicoScope Automotive Software button. 7. The program will guide you through the rest of the installation.

3.2 Connecting the PC Oscilloscope to your PC

From this point the software should already have been installed on the PC. If the software hasn’t already been installed then please follow the steps in 3.1 on Installing the software.

Connect the USB connector on the PicoScope PC Oscilloscope to the USB port on the computer. To minimise the risk of electromagnetic interference, please use the USB cable provided. The light on the front of the oscilloscope should now be on or flashing, showing that the unit has power.

3.3 Starting the application software

The Oscilloscope Diagnostics Kit is supplied with the PicoScope application program. To start PicoScope simply click the PicoScope icon in the Pico Technology group in the Start menu.

Pico Technology Diagnostics Kit — 3 Installation Guide diagram (page 3)
Fig. 3 · 3 Installation Guide

PicoScope is our PC Oscilloscope application with added features for Automotive Diagnostics.

Page 4 of the Pico Technology Diagnostics Kit user manual — 3 Installation Guide
Page 4 · cliquer pour agrandir
Page 4

3.4 Finding your way around PicoScope

The drop-down menus and toolbars of the PicoScope display will be familiar to all users of Windows software.

The Automotive drop-down menu in the menu bar is an important feature of the Automotive software.

Pico Technology Diagnostics Kit — 3 Installation Guide diagram (page 4)
Fig. 4 · 3 Installation Guide

This menu displays a selection of the common measurements that can be taken using the Automotive Kit. When you select one of the measurement options from the menu, PicoScope will automatically:

  • Load a sample waveform appropriate to the chosen measurement
  • Change its settings to the defaults for the chosen measurement
  • Display a web-based help page with information on the accessories needed to take the measurement, setting up the equipment, example captured waveforms and any additional technical information that may be useful.
Page 5 of the Pico Technology Diagnostics Kit user manual — 3 Installation Guide
Page 5 · cliquer pour agrandir
Page 5
Pico Technology Diagnostics Kit — 3 Installation Guide diagram (page 5)
Fig. 5 · 3 Installation Guide

The top tool bar gives you all the frequently used controls for the oscilloscope. The first group of buttons on the left of the toolbar opens different windows:

Opens a new oscilloscope window

Opens the spectrum analyser window

Shows the readings in a meter view.

Both channels are controlled by the timebase drop-down menus:

The timebase menus control the amount of time that the trace takes to travel horizontally across one square on the grid. The first drop-down menu selects the amount of time taken to travel through one square when the horizontal zoom factor is set to x1. The second drop-down menu selects the horizontal zoom factor.

The PicoScope 3223 PC Oscilloscope has two channels: A and B. The 3423 variant has two further channels: C and D. Each channel is controlled by its own set of controls in the top toolbar:

Page 6 of the Pico Technology Diagnostics Kit user manual — 3 Installation Guide
Page 6 · cliquer pour agrandir
Page 6

The first drop-down menu selects the range of signal that you are interested in measuring. If any custom ranges are defined, these will also be displayed here.

The second drop-down menu selects either AC or DC coupling.

The third drop-down menu selects a vertical zoom factor of x1, x2 or x5, allowing smaller details in the signal to be viewed.

Additional information on the rest of the drop-down menus in the top toolbar can be found in the help menu installed with the software.

On the bottom toolbar, the ‘STOP’ / ‘GO’ button starts and stops the capturing of waveforms (the spacebar has the same effect). When you stop the oscilloscope, it will hold the last waveform on the display.

The bottom toolbar also contains the controls for setting up the triggering conditions for the oscilloscope. Triggering is used to select the moment when PicoScope starts to collect data to display. This is usually at some fixed time before or after a trigger event. There is only one set of trigger settings, which applies to all views.

A trigger event occurs when a specified channel crosses a voltage threshold (while rising or falling). PicoScope can start collecting data immediately after the trigger event or at a fixed time interval before or after the trigger event.

After PicoScope has collected a block of data and displayed it, it can either start looking for the next trigger event (repeat mode), or stop collecting (single mode), leaving the data after the trigger on the display.

3.5 Making your first measurement

We suggest that you first use the Oscilloscope Diagnostics Kit to capture the current and voltage waveforms from the alternator. You will find this option in the Automotive Menu under Miscellaneous | Charging circuits | Current / Volts. The help page that appears automatically will show you how to connect the different parts of the Oscilloscope Diagnostics Kit and give you a basic understanding of the kit.

Pico Technology Diagnostics Kit — 3 Installation Guide diagram (page 6)
Fig. 6 · 3 Installation Guide
Page 7 of the Pico Technology Diagnostics Kit user manual — 4 Safety Warnings
Page 7 · cliquer pour agrandir
Page 7

4 Safety Warnings

We strongly recommend that you read the general safety information below and also the product-specific safety warning in the user guide before using your product for the first time. If you do not use the equipment in the manner specified, then you may impair the protection provided. This could result in damage to your computer or injury to yourself or others.

The PicoScope 3000 Series Automotive user guide is installed on your computer when you install the supplied software.

Maximum input range The maximum input range of the PicoScope 3000 Series Automotive PC Oscilloscopes is ±50 V, and overload protection is ±100 V. Always operate the product within the maximum input range. Operation outside the range of the overload protection is likely to cause permanent damage to the unit.

Measuring inductive signals When using the PicoScope 3000 Series Automotive PC Oscilloscopes to measure signals from a fuel injector, primary ignition waveforms or any other inductive signal, you must fit the PP198 attenuator.

The PP198 provides increased input protection against overloads when working with primary ignition and injector waveforms. Under no circumstances attempt to use this attenuator to measure any other waveforms. Use the PP178 Secondary Ignition Pickup lead to measure secondary ignition (HT) waveforms.

Using the secondary ignition pickup PP178 When attaching or removing secondary ignition pickups from damaged HT leads there is a possibility of getting an electric shock. To eliminate this danger, attach and remove the secondary ignition pickup with the ignition turned off.

Mains voltages No Pico products are designed for use with mains voltages. To measure mains we recommend the use of a differential isolating probe specifically designed for such measurements.

Safety grounding The ground of every product is connected directly to the ground of your computer through the provided USB cable. This is done in order to minimise interference. Always use the provided cable to attach the product to your computer.

As with most oscilloscopes, you should take care to avoid connecting the ground input of the product to anything which may be at some voltage other than ground. If in doubt, use a meter to check that there is no significant AC or DC voltage. Failure to check may cause damage to the product or computer and could cause injury to yourself or others.

You should assume that the product does not have a protective safety earth. Misconfiguration or use on voltages outside the maximum input range can be hazardous.

Loose items Make sure that any body parts, items of clothing, test equipment and other objects are kept away from any moving parts such as pulleys and fans.

Page 8 of the Pico Technology Diagnostics Kit user manual — 5 Technical Support
Page 8 · cliquer pour agrandir
Page 8

Condition of equipment Before using any of the probes, sensors or test equipment, make sure they are not damaged in any way.

Repairs The unit contains no user-serviceable parts. Repair or calibration of the unit requires specialised test equipment and must be performed by Pico Technology Limited or its authorised distributors.

5 Technical Support

Pico Technology can give technical support on the products within the Oscilloscope Diagnostics Kit, but we cannot give advice on how to diagnose problems with your vehicles.

The Pico Technology web site contains regularly updated technical support at www.picotech.com You can also contact our technical support team directly:

Tel+44 (0) 1480 396 395 Fax: +44 (0) 1480 396 296 Email: support@ picotech.com
Page 9 of the Pico Technology Diagnostics Kit user manual — 6 Key Specifications of the PicoScope 3000 Series Automotive PC Oscilloscopes
Page 9 · cliquer pour agrandir
Page 9

6 Key Specifications of the PicoScope 3000 Series Automotive PC Oscilloscopes

Pico Technology Diagnostics Kit — 6 Key Specifications of the PicoScope 3000 Series Automotive PC Oscilloscopes diagram (page 9)
Fig. 7 · 6 Key Specifications of the PicoScope 3000 Series Au…

±50 V, ±20 V, ± 10V, ±5 V, ±2 V, ±1 V, ±500 mV, ±200 mV, ±100 mV, ±50 mV, ±20

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Pico Technology Diagnostics Kit

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Pico Technology Diagnostics Kit

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Pico Technology Diagnostics Kit manuel PDF

64 pages·8.5 MB·Divers·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…