The Pico Technology Oscilloscope Diagnostics Kits are based on our PicoScope 3000 Series Automotive PC Oscilloscopes and include our own automotive-specific software. The PC Oscilloscope turns a laptop or desktop PC into a powerful automotive diagnostic tool for fault-finding the increasing number of sensors, actuators and electronic circuits found on today’s vehicles.
This manual is a quick start guide which lists the products in the kit and shows you how to make your first measurements using the Pico Oscilloscope Diagnostics Kit.
For further information, you can consult the PicoScope 3000 Series Automotive user guide which contains detailed information about using the product and its software. It includes all the information you will need to connect and set up your product. The user guide is installed in electronic Windows Help format, but if you would prefer a paper copy, you can print the PDF file listed under ‘User Manuals’ on the CD-ROM.
The Oscilloscope Diagnostics Kit is available in three versions: two-channel (PP280), four-channel (PP276) and commercial (PP286). The number of accessories varies between the versions, as shown below.




3.1 Installing the software
The PicoScope Automotive software has been designed to run on computers with Windows XP SP2 and Vista.
3.2 Connecting the PC Oscilloscope to your PC
From this point the software should already have been installed on the PC. If the software hasn’t already been installed then please follow the steps in 3.1 on Installing the software.
Connect the USB connector on the PicoScope PC Oscilloscope to the USB port on the computer. To minimise the risk of electromagnetic interference, please use the USB cable provided. The light on the front of the oscilloscope should now be on or flashing, showing that the unit has power.
3.3 Starting the application software
The Oscilloscope Diagnostics Kit is supplied with the PicoScope application program. To start PicoScope simply click the PicoScope icon in the Pico Technology group in the Start menu.

PicoScope is our PC Oscilloscope application with added features for Automotive Diagnostics.

3.4 Finding your way around PicoScope
The drop-down menus and toolbars of the PicoScope display will be familiar to all users of Windows software.
The Automotive drop-down menu in the menu bar is an important feature of the Automotive software.

This menu displays a selection of the common measurements that can be taken using the Automotive Kit. When you select one of the measurement options from the menu, PicoScope will automatically:


The top tool bar gives you all the frequently used controls for the oscilloscope. The first group of buttons on the left of the toolbar opens different windows:
Opens a new oscilloscope window
Opens the spectrum analyser window
Shows the readings in a meter view.
Both channels are controlled by the timebase drop-down menus:
The timebase menus control the amount of time that the trace takes to travel horizontally across one square on the grid. The first drop-down menu selects the amount of time taken to travel through one square when the horizontal zoom factor is set to x1. The second drop-down menu selects the horizontal zoom factor.
The PicoScope 3223 PC Oscilloscope has two channels: A and B. The 3423 variant has two further channels: C and D. Each channel is controlled by its own set of controls in the top toolbar:

The first drop-down menu selects the range of signal that you are interested in measuring. If any custom ranges are defined, these will also be displayed here.
The second drop-down menu selects either AC or DC coupling.
The third drop-down menu selects a vertical zoom factor of x1, x2 or x5, allowing smaller details in the signal to be viewed.
Additional information on the rest of the drop-down menus in the top toolbar can be found in the help menu installed with the software.
On the bottom toolbar, the ‘STOP’ / ‘GO’ button starts and stops the capturing of waveforms (the spacebar has the same effect). When you stop the oscilloscope, it will hold the last waveform on the display.
The bottom toolbar also contains the controls for setting up the triggering conditions for the oscilloscope. Triggering is used to select the moment when PicoScope starts to collect data to display. This is usually at some fixed time before or after a trigger event. There is only one set of trigger settings, which applies to all views.
A trigger event occurs when a specified channel crosses a voltage threshold (while rising or falling). PicoScope can start collecting data immediately after the trigger event or at a fixed time interval before or after the trigger event.
After PicoScope has collected a block of data and displayed it, it can either start looking for the next trigger event (repeat mode), or stop collecting (single mode), leaving the data after the trigger on the display.
3.5 Making your first measurement
We suggest that you first use the Oscilloscope Diagnostics Kit to capture the current and voltage waveforms from the alternator. You will find this option in the Automotive Menu under Miscellaneous | Charging circuits | Current / Volts. The help page that appears automatically will show you how to connect the different parts of the Oscilloscope Diagnostics Kit and give you a basic understanding of the kit.


We strongly recommend that you read the general safety information below and also the product-specific safety warning in the user guide before using your product for the first time. If you do not use the equipment in the manner specified, then you may impair the protection provided. This could result in damage to your computer or injury to yourself or others.
The PicoScope 3000 Series Automotive user guide is installed on your computer when you install the supplied software.
Maximum input range The maximum input range of the PicoScope 3000 Series Automotive PC Oscilloscopes is ±50 V, and overload protection is ±100 V. Always operate the product within the maximum input range. Operation outside the range of the overload protection is likely to cause permanent damage to the unit.
Measuring inductive signals When using the PicoScope 3000 Series Automotive PC Oscilloscopes to measure signals from a fuel injector, primary ignition waveforms or any other inductive signal, you must fit the PP198 attenuator.
The PP198 provides increased input protection against overloads when working with primary ignition and injector waveforms. Under no circumstances attempt to use this attenuator to measure any other waveforms. Use the PP178 Secondary Ignition Pickup lead to measure secondary ignition (HT) waveforms.
Using the secondary ignition pickup PP178 When attaching or removing secondary ignition pickups from damaged HT leads there is a possibility of getting an electric shock. To eliminate this danger, attach and remove the secondary ignition pickup with the ignition turned off.
Mains voltages No Pico products are designed for use with mains voltages. To measure mains we recommend the use of a differential isolating probe specifically designed for such measurements.
Safety grounding The ground of every product is connected directly to the ground of your computer through the provided USB cable. This is done in order to minimise interference. Always use the provided cable to attach the product to your computer.
As with most oscilloscopes, you should take care to avoid connecting the ground input of the product to anything which may be at some voltage other than ground. If in doubt, use a meter to check that there is no significant AC or DC voltage. Failure to check may cause damage to the product or computer and could cause injury to yourself or others.
You should assume that the product does not have a protective safety earth. Misconfiguration or use on voltages outside the maximum input range can be hazardous.
Loose items Make sure that any body parts, items of clothing, test equipment and other objects are kept away from any moving parts such as pulleys and fans.

Condition of equipment Before using any of the probes, sensors or test equipment, make sure they are not damaged in any way.
Repairs The unit contains no user-serviceable parts. Repair or calibration of the unit requires specialised test equipment and must be performed by Pico Technology Limited or its authorised distributors.
Pico Technology can give technical support on the products within the Oscilloscope Diagnostics Kit, but we cannot give advice on how to diagnose problems with your vehicles.
The Pico Technology web site contains regularly updated technical support at www.picotech.com You can also contact our technical support team directly:


±50 V, ±20 V, ± 10V, ±5 V, ±2 V, ±1 V, ±500 mV, ±200 mV, ±100 mV, ±50 mV, ±20