This user manual includes information to operate your device and precautions for your safety. To get the best of your equipment please read carefully before use.
START devices are designed for charging and starting 12V (6 element) and 24V (12 element) lead acid batteries (electrolyte):
Check that the power and protection (fuse and / or circuit breaker) are compatible with the current required. The appliance must be positioned so that the plug socket is accessible. They must be connected to a single phase 230V socket with EARTH protected by a 16A circuit breaker.
Monitoring and state of charge CAUTION: Charging batteries require monitoring and the charge will only stop when the operator switches the START to "OFF" or disconnects the device from the mains. When the battery is charged, the liquid (electrolyte) in the battery starts to "boil". It is recommended to stop the charge at the beginning of this phenomenon to avoid damaging the battery. Moreover if the battery is connected to a vehicle, a prolonged load unsupervised can damage the vehicle electronics. As well as sulphated battery refusing the load will cause the same risks directly from connecting the charger to the battery. The end of the load is detected by the needle position of the ammeter when it is between 0 and 10A or by a time greater than 10H load.

Sealed battery To charge a sealed battery, it is necessary to be extremely careful. The charge must be applied slowly whilst constantly monitoring the battery voltage. It is recommended to stop the charge when the voltage (voltage charging court) reaches 14.4V for a 12V battery and 28.8V for a 24V battery. This voltage can be measured using a voltmeter or battery tester.
Charge Once the charger is connected to the battery as recommended (see connection and disconnection),
For the START 200 and 300: - Turn the switch to the CHARGE or BOOST 1 position according to the battery capacity. Warning : In Boost 1 mode thermal protection might be activated at the beginning of the charge if the battery is deeply discharged.
After use follow the recommended instructions for disconnection.
Charging multiple batteries simultaneously You can charge multiple batteries simultaneously connecting them in parallel. Connect the positive terminals to the red clamp and the negative terminals to the black clamp. These batteries or group of batteries must all be the same voltage, 12 or 24V. Charging in series is not recommended.
Precautions before use • Do not disconnect the battery from the vehicle. Disconnecting the battery may result in loss of information and a possible inability to restart.
Starting Once you have connected the starter to the battery as recommended (see connection), it may be necessary to precharge the battery to provide the energy needed for starting. To perform a precharge turn the switch on the "BOOST " position.
START 200 and 300 :
To perform the precharge set the switch to the "BOOST" position. To start a vehicle turn the switch to the "START" position. Go to the vehicle driver side. By turning the key you activate the starter function. This function must be stopped as soon the vehicle start. It is ideal to work with two people. The one close to the START can turn the switch to the START position at the last moment and stops the device once the vehicle has started.
If your engine does not start, wait 2 minutes between two start attempts. The attempt must last a maximum of 3 sec. Nb: A vehicle that will not start can be a problem other than a battery in poor condition. It could come from many other causes.
After use follow the recommended instructions for disconnection.