START 200 / 300 EN

This user manual includes information to operate your device and precautions for your safety. To get the best of your equipment please read carefully before use.

GENERAL DESCRIPTION

START devices are designed for charging and starting 12V (6 element) and 24V (12 element) lead acid batteries (electrolyte):

ChargingStarting Start 20053 - 240 Ah35 - 80 Ah Start 30038 - 300 Ah35 - 100 Ah

POWER SUPPLY

Check that the power and protection (fuse and / or circuit breaker) are compatible with the current required. The appliance must be positioned so that the plug socket is accessible. They must be connected to a single phase 230V socket with EARTH protected by a 16A circuit breaker.

CONNECTION AND DISCONNECTION

  • Starting and Charging a battery connected on the vehicle: Where the negative pole of the battery is connected to the vehicle chassis
  • Connect the red clamp to the positive pole of the battery.
  • Connect the black clamp to the vehicle chassis, ensure it is not close to fuel lines and the battery.
  • Connect the device to the mains.
  • After use, turn the switch to OFF (if any), then disconnect the charger from the mains supply then disconnect the black clamp and finally the red clamp.
  • Some vehicles have the positive pole of the battery connected to the chassis, in this case:
  • Connect the black clamp to the negative terminal of the battery.
  • Connect the red clamp to the vehicle chassis, ensure it is not close to fuel lines and battery.
  • Connect the device to the mains.
  • After use, turn the switch to OFF (if any), then disconnect the charger from the mains supply then disconnect the red clamp and finally the black clamp.
  • Charging a battery not connected to the vehicle:
  • Connect the red clamp to the positive battery terminal and then the black clamp to the negative terminal of the battery.
  • After use, turn the switch to OFF (if any), then disconnect the charger from the mains supply then disconnect the red clamp and finally the black clamp.

USE IN CHARGING MODE

  • Precautions before use
  • Choose a sufficiently ventilated area
  • Remove the caps on the battery (if any) and make sure the water level (electrolyte) is sufficient. Otherwise add deionized water and carefully clean the battery terminals.
  • Check that the battery capacity in amps/hour and voltage in volts are compatible with your charger.

Monitoring and state of charge CAUTION: Charging batteries require monitoring and the charge will only stop when the operator switches the START to "OFF" or disconnects the device from the mains. When the battery is charged, the liquid (electrolyte) in the battery starts to "boil". It is recommended to stop the charge at the beginning of this phenomenon to avoid damaging the battery. Moreover if the battery is connected to a vehicle, a prolonged load unsupervised can damage the vehicle electronics. As well as sulphated battery refusing the load will cause the same risks directly from connecting the charger to the battery. The end of the load is detected by the needle position of the ammeter when it is between 0 and 10A or by a time greater than 10H load.

Page 2 of the Gys START 200 user manual — USE IN STARTING MODE
Page 2 · cliquer pour agrandir
Page 2

START 200 / 300 EN

Sealed battery To charge a sealed battery, it is necessary to be extremely careful. The charge must be applied slowly whilst constantly monitoring the battery voltage. It is recommended to stop the charge when the voltage (voltage charging court) reaches 14.4V for a 12V battery and 28.8V for a 24V battery. This voltage can be measured using a voltmeter or battery tester.

Charge Once the charger is connected to the battery as recommended (see connection and disconnection),

For the START 200 and 300: - Turn the switch to the CHARGE or BOOST 1 position according to the battery capacity. Warning : In Boost 1 mode thermal protection might be activated at the beginning of the charge if the battery is deeply discharged.

CHARGE (12-24V) Start 20053 - 240 Ah (11A) Start 30038 - 300Ah (10A)

After use follow the recommended instructions for disconnection.

Charging multiple batteries simultaneously You can charge multiple batteries simultaneously connecting them in parallel. Connect the positive terminals to the red clamp and the negative terminals to the black clamp. These batteries or group of batteries must all be the same voltage, 12 or 24V. Charging in series is not recommended.

USE IN STARTING MODE

Precautions before use • Do not disconnect the battery from the vehicle. Disconnecting the battery may result in loss of information and a possible inability to restart.

Starting Once you have connected the starter to the battery as recommended (see connection), it may be necessary to precharge the battery to provide the energy needed for starting. To perform a precharge turn the switch on the "BOOST " position.

START 200 and 300 :

Instantaneously5 min precharge Start 20035 - 40 Ah40 - 80 Ah Start 30035 - 50 Ah50 - 100 Ah

To perform the precharge set the switch to the "BOOST" position. To start a vehicle turn the switch to the "START" position. Go to the vehicle driver side. By turning the key you activate the starter function. This function must be stopped as soon the vehicle start. It is ideal to work with two people. The one close to the START can turn the switch to the START position at the last moment and stops the device once the vehicle has started.

If your engine does not start, wait 2 minutes between two start attempts. The attempt must last a maximum of 3 sec. Nb: A vehicle that will not start can be a problem other than a battery in poor condition. It could come from many other causes.

After use follow the recommended instructions for disconnection.

Page 3 of the Gys START 200 user manual — TROUBLESHOOTING
Page 3 · cliquer pour agrandir
Page 3

START 200 / 300 EN

PROTECTION

  • This device has been designed with maximum protection:
  • The charging clamps are fully insulated.
  • A fuse provides proctection against reverse polarity and short circuits :
Start 200Start 300 Primary fuseCylindrical type 6.35x31.75 - Fast acting - 5A (little fuse ref : 53346)Cylindrical type 6.35c31.75 10A - Little Fuse. (Ref. 53356) Secondary fuse300mm - 50A (Little fuse serie : BF1 - 32 (Little Fuse ref : 51342)Little Fuse BF1 type - 80A (Ref. 53353)
  • The thermal protection is covered by a thermostat (cooling time is around 15mins). The green light turns itself off in the event of overheating for the Start 200, or the orange light turns itself on for the Start 300.

SULPHATED OR DAMAGED BATTERIES

  • START does not detect sulphated or damaged batteries.
  • Your battery is deeply damaged if in charge, the ammeter needle deflects rapidly to very high intensities. Your battery is permanently out of use.
  • In the case of a sulphated battery : turn the device on the highest speed "BOOST" and regularly monitor if the ammeter shows a charging current. As soon as the charging current increases, put the switch onto the suitable charging mode for the battery. If there is no improvement after 5 hours, the battery is permanently out of use. Caution - This procedure must be done with the battery disconnected from the vehicle!

WARNING

  • WARNING! Explosive gas , avoid flames and sparks . During charging, the battery should be placed in a ventilated area.
  • Protect the unit from rain and moisture
  • If the power cable is damaged it must be replaced by the manufacturer , its after sales or a similarly qualified person to avoid hazard.
  • Under no circumstances this appliance should be used to charge accu;ulators or non rechargeable batteries.
  • Respect the connection sequence indicated .
  • Product subject to separate collection , do not dispose in domestic waste .
  • This appliance is not intended for use by persons (including children) with reduced physical , sensory or mental capabilities, or lack of experience or knowledge, unless they could benifit by through a person responsible for their safety, supervision or instruction concerning use of the appliance .
  • Do not open the device. Modifications not performed by a manufacturer's technician leads to void the warranty .
  • Check that the available voltage corresponds to the one indicated on the nameplate of the charger.

TROUBLESHOOTING

AnomaliesCausesRemedies The ammeter does not move.Power supply problemCheck the power supply Check the machine is switched to the charge position "Polarity reversal or clamp in short circuit"Check the fuses is intact The battery is faultyCheck with a voltmeter the voltage on the terminals. If the voltage rises instantly at more than 2.5V per element, the battery may be damaged or sulphated. Volage error (12 -24 V)Check the switch is on the correct selection (12 or 24V) Following intensive use, the machine has switched off due to thermal protection to cool down.Wait for 15 min to allow cooling The ammeter indicates more than 20A whereas the selector adjustment is at the minimumThe battery is deeply dischargedKeep charging but only at a low output Voltage error (12 - 24 V)Check the switch is set correctly (12 or 24V) Some battery elements are in short-circuitChange the battery The machine stopsYou are starting whilst in the “charge” mode of the machineSwitch to the “start” position otherwise it could damaged the machine. A 12V battery is charged on the 24V outputPut the switch on the 12V position

Poser une question sur : Gys START 200

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Gys START 200

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Gys START 200 manuel PDF

28 pages·829 KB·Chargeur de batterie·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…