Thank you for choosing GYSPACK PRO – this is a high quality product and in order to get the maximum from it, we advise you to carefully read this instruction manual. Please also retain the manual for future reference.
The high performance internal battery allows the GYSPACK PRO to serve 3 functions:
Instant Start (1750 A peak / 600 A) from vehicle equipped with 12V Lead battery (Gel or Liquid
electrolyte). 12 V DC power supply, to supply light Spot, TV, tools, etc… In-built torch
To ensure good working conditions and optimize the durability of its internal Battery, it is important to recharge it after each use, and leave it plugged in until Next usage
Test of internal battery before the start In order to test the internal battery, press and the result will be displayed: Green light: Internal battery is charged. Starting is possible
In order to use the GYSPACK PRO as a starter, follow these steps:
Disconnect the Gyspack from the mains. Turn the vehicle ignition key to
OFF. Set the commutator of the Gyspack PRO to OFF. Be careful not to turn the
ignition key on before plugging the Gyspack. Connect the red clamp to the + terminal of the battery, and the black one
to the – terminal. A buzzer will indicate any polarity inversion. Switch the commutator of the Gyspack PRO on ON Go to the driver’s seat and turn the ignition key. If your engine does not
start, wait 3 minutes until next attempt. ( 6 sec max) Nb : A vehicle which does not start could have a problem not related to a defective battery: alternator, spark plug… Unplug the black clamp, then the red one from the vehicle.
Recharge your Gyspack after use. (see ‘Charging internal battery’)
Orange light · Red light · Starting a vehicle


Gyspack PRO is delivered with an automatic charger, which will charge its internal battery up to 100%, and maintain the charge, without supervision. The Floating System stops / restarts the charge automatically if needed, and the Gyspack PRO can remain plugged to the mains permanently.
To recharge the GYSPACK PRO:
Ensure the Gyspack is vertical/upright whilst charging. Nb : Failure to do this can result in an acid leak, and the destruction of the internal battery Plug the charger to the mains (230V socket), and the other end to the front of the GYSPACK The green light indicates that the GYSPACK is charged
Nb : IF after 24 hours the battery is still not charged (red or orange light), please stop charging. The internal battery may be damaged.
USING THE GYSPACK PRO AS 12V DC POWER SUPPLY
The GYSPACK PRO has an in-built spotlight comprised of 7 high intensity LEDs controlled by the "light" button. Repair should always be carried out by qualified personnel. WARRANTY EXCLUSIONS
Gyspack PRO contains a battery, which imperatively needs to be recharged after each use. If this recommendation is not strictly followed, the battery may become sulphated. For this reason, the GYSPACK battery is not covered by the warranty, as its conservation depends on its use and maintenance.

GYSPACK must be stored in a vertical position. Horizontal positions should only be temporary. Store your machine indoors, ensuring the area is well ventilated. Recharge the GYSPACK in a ventilated area, and do not create any sparks in a near location. The machine has to be placed for the main socket to be accessible. Examine GYSPACK charger regularly to detect any damage. If it is damaged, it should not be used
until repaired. If the casing of the charger is damaged, it should be replaced by the manufacturer under its after
sales service Do not open the device. Any modification not made by a GYS technician would invalidate the
warranty cover. GYSPACK is an electrical product, subject to particular waste. Do not dispose in domestic bins. This device is delivered with a CEE 7/7 Plug. It has to be connected to a 230V socket, including earth connection GYSPACK should not be used by young children. CERTIFICATE OF CONFORMITY
GYS confirms that the charger integrated in this product: GYSPACK PRO Is manufactured in conformity with the following European directive: - Directive on Low voltage: 2006/95/CE du 12/12/06. - Directive electromagnetic field : 2004/108/CE du 15/12/2004. It is conform to the following standards: - EN61558-1, EN61558-2-6 - EN55014-1, EN55014-2, EN61000-3-2, EN61000-3-3 Date of CE Mark: 2015