A.V. 2 Any reprints, even partial, are subject to approval. Technical changes reserved. Pictures are just for illustration Marking:
Appliance description (pic. 1) 1. Ammeter 2. Fuse (2 x 50 A) 3. Level selector (1-2) 4. Mode selector (charging/start) 5. Pole Poled connection a 24 V 6. Pole Poled connection a 12 V 7. Level selector (min./max.) 8. Main switch (ON/OFF) +remote control Warranty
Product safety:
Product corresponds to appropriate
standards of the EU
Prohibitions:
Using the appliance when wet
prohibited! Warning:
A warranty period of 12 months applies to commercial use and 24 months apply to private use and commences on the day of purchase of the device. Warranty applies exclusively to failures due to defective material or workmanship. An original sale slip with indication of date of sale must be presented in case of claiming for the warranty rights. Warranty does not cover unprofessional use such as device overload, violent use, damage caused by third party or foreign materials, failure to comply with operations and assembly manual, and normal wear and tear. General Safety Regulations
Commands:
Read operating manual before use Use protection gloves
Environment Protection:

Packing cardboard material may be delivered to collecting centres
or electronic devices must be delivered to appropriate collection
Package:
Protect against humidity This side up
Technical data:

Professional charger start to load and quick loading, and for starting of vehicles.
General prohibition mark

Notice: Do not use unless the mains connection is provided with a back up circuit breaker (FI circuit breaker). Commissioning 1. Check on the line voltage (230 V three-phase or 400 V three phase). 2. Connect the red-clamp cable to terminal (+12) or (+24) of the battery charger. 3. Connect the red clamp to the positive pole (+) of the battery. 4. Connect the black clamp to the negative pole (-) of the battery Emergency Action
Apply the first aid adequate to the injury and get qualified medical assistance as quickly as possible. Protect the injured person from more accidents and calm him/her down. Assigned Use These devices can be used to charge lead batteries typically used in motor vehicles (petrol and diesel fuel). The type of electrolyte may be selected freely

Using the appliance only requires corresponding training by a professional or following of the Operating Instructions. No special training is necessary. Technical data

Important Notice! Replacement fuses, the resistance values of which are different from the plate values, may cause material and personal damage The fuses replacement should not be done unless the mains cable is unplugged. We shall not be held liable, not even for the repair if the procedure is contrary to the requirement Fig 1 Fig 2 A. Fuse A. Fuse B. Fuse Residual Electrical Hazards 1. Direct electrical contact
Pic. 4: 1: Beginning of charging 2: In the course of charging 3: End of Chargign 4: Empty 5: Half-charged 6: Fully charged During charging, the current (value being shown on the digital ammeter) drops slowly based on the W curve according to DIN 41774. As soon as the battery is fully charged, the digital indicator shows values close to zero. Values given in pictures are just for information purposes and may differ during the actual charging process, depending on the battery.
Defective cable one plug may cause an electrical shock injury. Have the defective cables and plugs replaced at a
specialist’s. Use the unit on a connection equipped with a current protection (FI). 2. Indirect electrical contact
A risk of injury by conductive parts with open or defective parts of the unit Disconnect the unit from the source of power to
maintain it. Operate with a current protection only. 3. Insufficient Lighting of Workplace
Insufficient lighting always present a high safety risk. Always provide for sufficient lighting when working
with the unit. Disposal
The disposal instructions are based on icons on the appliance or its package. Handling requirements
The operating staff must carefully read the Operating Instructions before using the appliance. Qualification
Apart from the detailed instruction by a professional no special qualification is necessary for using the appliance. Minimum age
Only persons over 16 years of age can work with the appliance. An exception includes youngsters if they work within their professional education the purpose of which is to obtain knowledge supervised by a trainer.
Training

Too heavy charging current at the beginning of charging 1. Watch out the charging current if it is high even after 15 - 20 minutes, it may mean that the charge would not hold Have the battery checked at a specialist’s. Replace the battery.
Too weak charging current . 1. Try to adjust the charging current control higher.
Ammeter pointer touches the lowest position of the scale 1. Have the battery checked at a specialist. Replace the batteries 2. Ensure that the mains voltage is equal to the desired value
Ammeter does not indicate. 1. Clean the terminals and put the clamp on again. 2. Have it checked at a specialists . Replace the battery.
Check on the charger working ability on a perfect charged battery.
Overload Causes 1. Mixing up the poles when connecting the clamp to the battery 2. The battery is heavily or completely discharged. 3. Battery is completely discharged and its capacity is higher than the charger power 4. Battery is damaged or defective (internal elements short circuit). Inspections and Maintenance
After every use Clean the vents and moving parts from dust
Regularly Oil the moving metal parts (multi-purpose oil)
Regularly Check all the screws to see if they are tight.
Charging 1. Connect the charger . 2. Set the charging function up (min/1). 3. Switch the charger on . 4. Plug in . 5. Battery is being charged. (max. 10 hrs) Starting 1. Connect the charger . 2. Set the starting up. 3. Connect to the mains ě. 4. Switch the charger on and start the vehicle immediately. 5. Jas soon as the vehicle is up, stop starting and switch off and disconnect the charger. Troubles-Causes-Troubleshooting
Overload circuit-breaker: 1. Connect the red clamp to the positive pole and the black one to the negative pole. 2. Remove the contact and check the fuses. 3. Set the charger at the lowest charging degree. .
•