Environmental protection

Please read and comply with these instructions prior to the initial operation of your appliance. Retain these operating instructions for future refer- ence or for subsequent possessors.

The packaging material can be recy- cled. Please do not place the pack- aging into the ordinary refuse for disposal, but arrange for the proper recycling.

Old appliances contain valuable ma- terials that can be recycled. Please arrange for the proper recycling of old appliances. Please dispose your old ap- pliances using appropriate collection sys- tems.

Proper use

This appliance has been designed for use in private households and is not intended for commercial use. The manufacturer is not responsible for any damages that may occur on account of im- proper use or wrong operations. The appliance is primarily meant for use at home and in the garden.

Warranty

The warranty terms published by our com- petent sales company are applicable in each country. We will repair potential fail- ures of your appliance within the warranty period free of charge, provided that such failure is caused by faulty material or de- fects in fabrication. In the event of a warran- ty claim please contact your dealer or the nearest authorized Customer Service cent- er. Please submit the proof of purchase.

Approved fluids that can be drained:

„ processed water „ Well water „ Water source „ Rain water „ Water from swimming pool (provided the dosing of additives is proper) Caution

The device is not meant for transporting water for human consumption. Caustic, slightly inflammable and other explosive substances such as petrol, petroleum, diluted nitrogen, greases, oils, salt water and waste water from toi- lets should not be transported using the pump. The temperature of the trans- ported fluids should not exceed 35°C. The appliance is not suitable for contin- uous circulation.

Safety instructions

Danger of death Violating these safety instructions may re- sult in death through electrocution. „ Check the power cord with mains plug for damage before every use. If the power cord is damaged, please arrange immediately for the exchange by an au- thorized customer service or a skilled electrician. „ All electrical sockets should be fixed in an area that is protected against floods. „ Unsuitable extension cables can be hazardous. Only use extension cables outdoors which have been approved for this purpose and labelled with a suffi- cient cable cross-section. The plug and coupling of the extension cable used must be watertight. „ Do not use the power cord to carry/ transport the machine.

Dear Customer,

Page 2 of the Gardena GP 40 user manual — Preparing the Appliance
Page 2 · cliquer pour agrandir
Page 2

„ To separate the machine from the mains, pull the plug and not the power cord. „ Do not scrape the power cord across sharp edges and ensure that it does not get pressed. „ Install the appliance in a safe position at a place protected against flooding. „ Do not operate the appliance continu- ously in rain or during humid weather. „ The voltage indicated on the type plate must correspond to the voltage of the electrical source. „ To avoid risks, all repairs and replace- ment of spare parts may only be carried out by the authorised customer service personnel. „ The water in the pump heats up if there is no water supply or the pressure side is closed and can cause injury if it flows out! The pump may be operated for maxi- mum 3 minutes in this operating status. „ Do not use this pump as an immersion pump. „ When using the pump near to pools, garden ponds or fountains, observe a minimum distance of 2m and safeguard the device against slipping into the wa- ter. „ Follow the rules for electrical safety of equipment: Only operate pumps near to pools, gar- den ponds or fountains, if they are equipped with an earth leakage circuit breaker with a nominal error current of max. 30 mA. It is not permitted to acti- vate the pump, if persons are in the pool or garden pond. For safety reasons, we recommend that you operate the appliance only via a earth-leakage circuit breaker (max. 30 mA). The electrical connection of the system may only be performed by a qualified electrician. Please follow the respective national regulations!

In Austria pumps to be used in swim- ming pools and garden ponds should be equipped with a fixed connection line according to ÖVE B/EN 60555 Part 1 to 3; power supply should be via a ÖVE- tested isolating transformer whereby the secondary nominal voltage should not exceed 230V.

Start up

Please follow the safety instructions before start-up!

Description of the Appliance

1 Power cord with plug 2 Connection G1“(33.3mm) Pressure pipe 3 Filling nozzle 4 Connection G1“(33.3mm) Suction pipe 5 Drain opening 6 ON/OFF switch 7 Screw-in nozzle G1" (33.3 mm)

Preparing the Appliance

Illustration Î Bring the on/off switch to position "0". Illustration Î Screw in the connection nozzle. Î Connect suction and pressure pipes us-

ing Kärcher special accessory G1“(33.3mm). Illustration Î Unscrew the lid of the filling nozzle and

fill in water till it overflows. Î Screw on the lid on the filling nozzle.

Page 3 of the Gardena GP 40 user manual — Storage
Page 3 · cliquer pour agrandir
Page 3

Operation

CE declaration

Î Insert the plug into the socket. Illustration Î Tip: Raise the suction hose by approx.

We hereby declare that the machine de- scribed below complies with the relevant basic safety and health requirements of the EU Directives, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the machine is modified without our prior approval.

1m to reduce the suction period Î Switch on the unit with the ON/OFF

switch (position 1). Î Wait till the pump sucks in and trans-

ports water uniformly Caution The water in the pump heats up if there is no water supply or the pressure side is closed and can cause injury if it flows out! The pump may be operated for maximum 3 minutes in this operating status.

Product: Pump Type: 1.645-xxx Relevant EU Directives 98/37/EC 2006/95/EC 89/336/EEC (+91/263/EEC, 92/31/EEC, 93/68/EEC) 2000/14/EC Applied harmonized standards EN 55014–1: 2000 + A1: 2001 + A2: 2002 EN 55014–2: 1997 + A1: 2001 EN 60335–1 EN 60335–2–41 EN 61000–3–2: 2000 + A2: 2005 EN 61000–3–3: 1995 + A1: 2001 Applied conformity evaluation method Appendix V Sound power level dB(A) Measured: 82 Guaranteed: 84

Finish operation

Î Rinse the pump after every use if you

use to transport water with additives. Î Disconnect the main plug from the sock-

et.

Maintenance and Care

Maintenance

The appliance is maintenance-free.

Storage

Î Empty water in the pump using the drain

The undersigned act on behalf and under the power of attorney of the company man- agement.

screw (item 5). Î Store the appliance in a frost free area.

Alfred Kärcher GmbH Co. KG Alfred Kärcher-Str. 28 - 40 D - 71364 Winnenden Phone: +49 7195 14-0 Fax: +49 7195 14-2212

Page 4 of the Gardena GP 40 user manual — Troubleshooting
Page 4 · cliquer pour agrandir
Page 4

Troubleshooting

Caution To avoid risks, all repairs and replacement of spare parts may only be carried out by the authorized customer service personnel. First pull out the plug from the mains before carrying out any tasks on the machine.

Pump runs but does not transport

Air in the pump see chapter "Preparation" fig. B and and chapter "Op- erations" fig. D

Suction area blocked Pull out the mains plug and clean the suction area

Pump does not run or sud- denly comes to a standstill during operations

Power supply interrupted Check fuses and electrical connections

Thermal protection switch has switched off the pump due to over-heating

Pull out the mains plug, let the pump cool down, clean the suction area, prevent dry running

Pump transports is reduc- ing or transported quantity is too low

Suction area blocked Pull out the mains plug and clean the suction area

The quantity transported by the pump depends on the transport height and the con- nected periphery

Keep max. flow height, see technical data

Our Kärcher branch will be pleased to help you further in the case of questions or faults. See address on the reverse.

Fault Cause Remedy

Page 5 of the Gardena GP 40 user manual — GP 40
Page 5 · cliquer pour agrandir
Page 5

Specifications

GP 40

Voltage V 230 - 240

Output Pnom W 650

Max. flow rate l/h 3000

Max. Suction height m 9

Max. pressure MPa (bar)

Max. flow height m 36

Max. grain size of the dirt particles that can be transported mm 1

Subject to technical modifications!

Operating pressure and transported quantity depends on the suction height and the connected periphery!

Frequency Hz 50 · 0,36 (3,6) · Weight kg 7,3

Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
Pump runs but does not transportAir in the pumpsee chapter "Preparation" fig. B and and chapter "Op- erations" fig. D p.4
Pump runs but does not transportSuction area blockedPull out the mains plug and clean the suction area p.4
Pump does not run or sud- denly comes to a standstill during operationsPower supply interruptedCheck fuses and electrical connections p.4
Pump does not run or sud- denly comes to a standstill during operationsThermal protection switch has switched off the pump due to over-heatingPull out the mains plug, let the pump cool down, clean the suction area, prevent dry running p.4
Pump transports is reduc- ing or transported quantity is too lowSuction area blockedPull out the mains plug and clean the suction area p.4
Pump transports is reduc- ing or transported quantity is too lowThe quantity transported by the pump depends on the transport height and the con- nected peripheryKeep max. flow height, see technical data p.4

Poser une question sur : Gardena GP 40

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Gardena GP 40

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Gardena GP 40 manuel PDF

50 pages·911 KB·Pompe de jardin·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…