Please read and comply with these instructions prior to the initial operation of your appliance. Retain these operating instructions for future refer- ence or for subsequent possessors.
The packaging material can be recy- cled. Please do not place the pack- aging into the ordinary refuse for disposal, but arrange for the proper recycling.
Old appliances contain valuable ma- terials that can be recycled. Please arrange for the proper recycling of old appliances. Please dispose your old ap- pliances using appropriate collection sys- tems.
This appliance has been designed for use in private households and is not intended for commercial use. The manufacturer is not responsible for any damages that may occur on account of im- proper use or wrong operations. The appliance is primarily meant for use at home and in the garden.
The warranty terms published by our com- petent sales company are applicable in each country. We will repair potential fail- ures of your appliance within the warranty period free of charge, provided that such failure is caused by faulty material or de- fects in fabrication. In the event of a warran- ty claim please contact your dealer or the nearest authorized Customer Service cent- er. Please submit the proof of purchase.
Approved fluids that can be drained:
processed water Well water Water source Rain water Water from swimming pool (provided the dosing of additives is proper) Caution
The device is not meant for transporting water for human consumption. Caustic, slightly inflammable and other explosive substances such as petrol, petroleum, diluted nitrogen, greases, oils, salt water and waste water from toi- lets should not be transported using the pump. The temperature of the trans- ported fluids should not exceed 35°C. The appliance is not suitable for contin- uous circulation.
Danger of death Violating these safety instructions may re- sult in death through electrocution. Check the power cord with mains plug for damage before every use. If the power cord is damaged, please arrange immediately for the exchange by an au- thorized customer service or a skilled electrician. All electrical sockets should be fixed in an area that is protected against floods. Unsuitable extension cables can be hazardous. Only use extension cables outdoors which have been approved for this purpose and labelled with a suffi- cient cable cross-section. The plug and coupling of the extension cable used must be watertight. Do not use the power cord to carry/ transport the machine.
Dear Customer,

To separate the machine from the mains, pull the plug and not the power cord. Do not scrape the power cord across sharp edges and ensure that it does not get pressed. Install the appliance in a safe position at a place protected against flooding. Do not operate the appliance continu- ously in rain or during humid weather. The voltage indicated on the type plate must correspond to the voltage of the electrical source. To avoid risks, all repairs and replace- ment of spare parts may only be carried out by the authorised customer service personnel. The water in the pump heats up if there is no water supply or the pressure side is closed and can cause injury if it flows out! The pump may be operated for maxi- mum 3 minutes in this operating status. Do not use this pump as an immersion pump. When using the pump near to pools, garden ponds or fountains, observe a minimum distance of 2m and safeguard the device against slipping into the wa- ter. Follow the rules for electrical safety of equipment: Only operate pumps near to pools, gar- den ponds or fountains, if they are equipped with an earth leakage circuit breaker with a nominal error current of max. 30 mA. It is not permitted to acti- vate the pump, if persons are in the pool or garden pond. For safety reasons, we recommend that you operate the appliance only via a earth-leakage circuit breaker (max. 30 mA). The electrical connection of the system may only be performed by a qualified electrician. Please follow the respective national regulations!
In Austria pumps to be used in swim- ming pools and garden ponds should be equipped with a fixed connection line according to ÖVE B/EN 60555 Part 1 to 3; power supply should be via a ÖVE- tested isolating transformer whereby the secondary nominal voltage should not exceed 230V.
Please follow the safety instructions before start-up!
1 Power cord with plug 2 Connection G1“(33.3mm) Pressure pipe 3 Filling nozzle 4 Connection G1“(33.3mm) Suction pipe 5 Drain opening 6 ON/OFF switch 7 Screw-in nozzle G1" (33.3 mm)
Illustration Î Bring the on/off switch to position "0". Illustration Î Screw in the connection nozzle. Î Connect suction and pressure pipes us-
ing Kärcher special accessory G1“(33.3mm). Illustration Î Unscrew the lid of the filling nozzle and
fill in water till it overflows. Î Screw on the lid on the filling nozzle.

CE declaration
Î Insert the plug into the socket. Illustration Î Tip: Raise the suction hose by approx.
We hereby declare that the machine de- scribed below complies with the relevant basic safety and health requirements of the EU Directives, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the machine is modified without our prior approval.
1m to reduce the suction period Î Switch on the unit with the ON/OFF
switch (position 1). Î Wait till the pump sucks in and trans-
ports water uniformly Caution The water in the pump heats up if there is no water supply or the pressure side is closed and can cause injury if it flows out! The pump may be operated for maximum 3 minutes in this operating status.
Product: Pump Type: 1.645-xxx Relevant EU Directives 98/37/EC 2006/95/EC 89/336/EEC (+91/263/EEC, 92/31/EEC, 93/68/EEC) 2000/14/EC Applied harmonized standards EN 55014–1: 2000 + A1: 2001 + A2: 2002 EN 55014–2: 1997 + A1: 2001 EN 60335–1 EN 60335–2–41 EN 61000–3–2: 2000 + A2: 2005 EN 61000–3–3: 1995 + A1: 2001 Applied conformity evaluation method Appendix V Sound power level dB(A) Measured: 82 Guaranteed: 84
Î Rinse the pump after every use if you
use to transport water with additives. Î Disconnect the main plug from the sock-
et.
The appliance is maintenance-free.
Î Empty water in the pump using the drain
The undersigned act on behalf and under the power of attorney of the company man- agement.
screw (item 5). Î Store the appliance in a frost free area.
Alfred Kärcher GmbH Co. KG Alfred Kärcher-Str. 28 - 40 D - 71364 Winnenden Phone: +49 7195 14-0 Fax: +49 7195 14-2212

Caution To avoid risks, all repairs and replacement of spare parts may only be carried out by the authorized customer service personnel. First pull out the plug from the mains before carrying out any tasks on the machine.
Pump runs but does not transport
Air in the pump see chapter "Preparation" fig. B and and chapter "Op- erations" fig. D
Suction area blocked Pull out the mains plug and clean the suction area
Pump does not run or sud- denly comes to a standstill during operations
Power supply interrupted Check fuses and electrical connections
Thermal protection switch has switched off the pump due to over-heating
Pull out the mains plug, let the pump cool down, clean the suction area, prevent dry running
Pump transports is reduc- ing or transported quantity is too low
Suction area blocked Pull out the mains plug and clean the suction area
The quantity transported by the pump depends on the transport height and the con- nected periphery
Keep max. flow height, see technical data
Our Kärcher branch will be pleased to help you further in the case of questions or faults. See address on the reverse.
Fault Cause Remedy

Voltage V 230 - 240
Output Pnom W 650
Max. flow rate l/h 3000
Max. Suction height m 9
Max. pressure MPa (bar)
Max. flow height m 36
Max. grain size of the dirt particles that can be transported mm 1
Subject to technical modifications!
Operating pressure and transported quantity depends on the suction height and the connected periphery!
Frequency Hz 50 · 0,36 (3,6) · Weight kg 7,3
Problèmes fréquents, causes probables et solutions.
| Problème | Cause possible | Solution | |
|---|---|---|---|
| Pump runs but does not transport | Air in the pump | see chapter "Preparation" fig. B and and chapter "Op- erations" fig. D | p.4 |
| Pump runs but does not transport | Suction area blocked | Pull out the mains plug and clean the suction area | p.4 |
| Pump does not run or sud- denly comes to a standstill during operations | Power supply interrupted | Check fuses and electrical connections | p.4 |
| Pump does not run or sud- denly comes to a standstill during operations | Thermal protection switch has switched off the pump due to over-heating | Pull out the mains plug, let the pump cool down, clean the suction area, prevent dry running | p.4 |
| Pump transports is reduc- ing or transported quantity is too low | Suction area blocked | Pull out the mains plug and clean the suction area | p.4 |