1. Introduction

thank you for purchasing this product.

This product complies with the statutory national and European specifications. To maintain this status and to ensure safe operation, you as the user must ob- serve these operating instructions!

These operating instructions are part of this product. They contain important notes on commissioning and handling. Also consider this if you pass on the product to any third party. Therefore, retain these operating instructions for reference!

If there are any technical questions, please contact:

Internationalwww.conrad.com/contact
United Kingdomwww.conrad-electronic.co.uk/contact

Page · Dear Customer,

Page 2 of the Basetech TS108B user manual — 3. Intended use
Page 2 · cliquer pour agrandir
Page 2

2. Explanation of symbols

The lightning symbol inside of a triangle is used when there is a

potential risk of personal injury, such as electric shock.

An exclamation mark in a triangle indicates important instructions in

these operating instructions which absolutely have to be observed.

The arrow symbol is used when specific tips and information on the

operation are provided.

3. Intended use

Adjust and regulate the temperature of your living space according to your needs with this room thermostat. It is operated via a control panel or the „BLUE STAT“ app (available for iOS and Android devices). Set up programs depending on the time or daytime. Also integrated is a holiday mode which controls the temperature during your absence. It is possible to control heating or cooling systems directly.

The room thermostat is mounted on a wall. The load connected is turned on or off (for max. connectable load, see “Technical data”) depending on the tempera- ture. Temperature is measured by an external sensor.

Power is supplied by two batteries of type AA/Mignon.

The product is designed for indoor use only. Do not use in wet rooms or under unfavourable ambient conditions. Unfavourable ambient conditions include:

-- Wet conditions or high air humidity

-- Dust and flammable gases, vapours or solvents

-- Thunderstorms or similar conditions such as strong electrostatic fields

Page 3 of the Basetech TS108B user manual — Up-to-date operating instructions
Page 3 · cliquer pour agrandir
Page 3

Use other than that described above can lead to damage to the product and may involve additional risks such as, for example, short circuits, fire, electrical shocks etc. No part of the product may be modified or reconfigured! Read the operating instructions carefully and keep them for later reference. If you pass the product on to a third party, please hand over these operating instructions as well.

The safety instructions should be observed without fail!

This product complies with the applicable national and European Regulations. All names of companies and products are the trademarks of the respective own- ers. All rights reserved.

Bluetooth® is a globally registered trademark by Bluetooth SiIG, Inc.

4. Package contents

  • Room thermostat
  • 2x screws
  • 2x dowels
  • Operating instructions

Up-to-date operating instructions

Download the latest operating instructions via the link www.conrad.com/downloads or scan the QR code. Follow the instructions on the website.

Page 4 of the Basetech TS108B user manual — 6. Safety instructions
Page 4 · cliquer pour agrandir
Page 4

5. Functions

  • Bluetooth ® 4.0: Operation possible for iOS and Android with an app
  • Heating and cooling mode; controlling of a heating or cooling device possible
  • The connected device is controlled by a potential-free relay with changeover contact
  • The room thermostat is operated using 2 batteries of type AA/Mignon
  • Up to 24 programs per week can be set
  • Five pre-configured temperature settings
  • Holiday mode

6. Safety instructions

Please read the operating instructions carefully and pay par- ticular attention to the safety instructions. We do not assume liability for any injuries/material damages resulting from failure to observe the safety instructions and the information in these operating instructions regarding the proper use of the product. Furthermore, in such cases, the warranty/guarantee will be null and void.

Only persons with relevant electro-technical knowledge and experience should carry out the installation! *)

If it is not installed properly, you risk:

  • your own life
  • the life of the person using the electrical system.

If it is not installed properly, you risk severe damage to property, e.g., by fire.

Page 5 of the Basetech TS108B user manual — a) General
Page 5 · cliquer pour agrandir
Page 5

You face the risk of being held liable for personal injury and mate- rial damage.

*) Specialist knowledge required for the installation:

In particular the following expertise is required in regards to the installation:

  • the applicable „5 safety rules“: Switch off power; secure against switching back on; determine voltage-free status; earthing and short-circuiting; cover or fence off nearby live parts
  • Choose appropriate tools, meters and, if necessary, personal protective equipment
  • Evaluation of the measurement results
  • Select the electrical installation material to ensure the shutdown conditions
  • IP protection types
  • Installation of the electrical installation material
  • Type of mains supply network (TN system, IT system, TT system) and the connection conditions that follow from them (classical earthing, protective earthing, required additional measures, etc.)

If you do not have the expertise required for the installation, do not connect and install it yourself, but ask a qualified techni- cian.

a) General

  • The unauthorised conversion and/or modification of the product is not allowed for safety and approval reasons.
  • Maintenance, adjustment or repair work may only be carried out by an expert/authorised service centre familiar with the hazards involved and the relevant regulations.

Contact an Electrician!

Page 6 of the Basetech TS108B user manual — b) Installation/connection
Page 6 · cliquer pour agrandir
Page 6
  • The product is not a toy and should be kept out of the reach of children! There is danger of a life-threatening electric shock! Install the product out of the reach of children.
  • Protect the product from extreme temperatures, direct sunlight, strong vibrations, high humidity, moisture, combustible gases, vapours and solvents.
  • On industrial sites, the accident prevention regulations of the association of the industrial workers‘ society for electrical equipment and utilities must be followed!
  • Do not leave the packaging material lying around carelessly as it may be a danger to children.
  • Handle the product with care; it can be damaged by impacts, blows or falls even from a low height.
  • If you have doubts about how the product should be operated or how to safely connect it, consult a qualified technician.
  • Maintenance, adjustment and repair work should only be carried out by an expert or a specialised workshop.
  • If you have any questions that are not answered in these operating instructions, please contact our technical customer service or other professionals.

b) Installation/connection

  • During installation, all poles must be disconnected from the mains voltage, e.g., via RCD. There must be an appropriately dimensioned fuse or circuit breaker between the RCD and the product.
  • The device must be voltage-free during installation and connection. Furthermore, turn off the automatic circuit breaker and the earth leakage circuit breaker to disconnect all the poles from the mains voltage.

Secure it against unauthorised reconnection, e.g., with a warn- ing sign.

Page 7 of the Basetech TS108B user manual — c) Batteries/rechargeable batteries
Page 7 · cliquer pour agrandir
Page 7
  • Check to make sure there is no voltage with a suitable measuring instrument (e.g., a digital multimeter).
  • Never connect the product to the power supply immediately after it has been transferred from a cold room into a warm one (e.g., during transport). The condensation that forms might destroy the device. Moreover, there is danger of electric shock!

Allow the product to reach room temperature. Wait until the con- densation has evaporated. This might take several hours. Only after this, should it be installed, connected to the mains supply and put into use.

  • Do not use the product in rooms with adverse environmental conditions, where combustible gases, vapours or dust are or may be present! There is a danger of explosion!
  • Do not exceed the max. connection load / switching capacity (see the chapter “Technical data”).

c) Batteries/rechargeable batteries

  • In general, it is possible to operate the room thermostat with rechargeable batteries. However, due to the lower voltage of rechargeable batteries (rechargeable battery = 1.2 V, battery = 1.5 V) and the lower capacity there is a shorter operating time. We recommend that you use preferably high-quality alkaline batteries in order to allow for long-lasting and reliable operation.
  • Batteries/rechargeable batteries must be kept out of the reach of children.
  • Do not leave batteries/rechargeable batteries lying around; they could be swallowed by children or pets. If swallowed, consult a doctor immediately. Danger to life!
  • Acid contact due to leaking or damaged single/rechargeable batteries can burn your skin, therefore use suitable protective gloves.
Page 8 of the Basetech TS108B user manual — c) Batteries/rechargeable batteries
Page 8 · cliquer pour agrandir
Page 8
  • Please observe the correct polarity (positive/+ and negative/-) when inserting the batteries (note plus/+ and minus/-).
  • Batteries/rechargeable batteries must never be short-circuited, taken apart or thrown into fire. There is a danger of explosion!
  • Do not recharge single-use, non-rechargeable batteries. There is a danger of explosion!
  • Replace dead batteries as soon as possible with a new one, or remove the spent batteries. Old batteries/rechargeable batteries can leak and damage the product!.
  • Replace a dead battery as soon as possible with a new one, or remove the spent battery. A dead battery may leak and can damage the device!
  • In the case of disuse for a longer period of time (e.g., storage), remove the inserted batteries/rechargeable batteries. As the battery ages, it poses a danger of leaking, which then can cause damage to the product. The warranty/guarantee will be void!
  • Always replace the whole set of batteries/rechargeable batteries, only use batteries/rechargeable batteries of the same type, by the same manufacturer and in the same charging state (do not mix charged batteries with half-charged or flat batteries/rechargeable batteries).
  • Never mix normal batteries with rechargeable batteries. Use either batteries or rechargeable batteries.
  • For the environmentally friendly disposal of batteries/rechargeable batteries, please read the chapter “Disposal”.
Page 9 of the Basetech TS108B user manual — 7. Installation and connection
Page 9 · cliquer pour agrandir
Page 9

7. Installation and connection

Observe the chapter “Safety Information”!

  • Use a suitable mains supply line (e.g. NYM-J) with a line cross-section of 1.5 mm².
  • The room thermostat must be protected with a 10/16 A fuse in the on-site sub-distribution. A residual-current circuit-breaker (FI protection switch) must be used upstream of this.
  • Connection and installation are only permitted in the powered-down condition.

Turn off the power on all poles of the mains supply by removing the respec- tive electric circuit fuse or switching off the circuit breaker. Also switch off the respective fault-current protective switch. Protect it from unauthorised re- activation, e.g. with a danger sign.

  • Check that the mains connection is free of current, e.g. with an appropriate tester.
  • The room thermostat consists of two parts that are held together by clips. The electronic parts with temperature sensor, display and control panel are in the front part. The batteries (2x type AA/Mignon, not included, can be ordered separately) are placed in this part. Please pay attention to the correct polarity (observe plus/+ and minus/-) when inserting the battery.
Basetech TS108B — 7. Installation and connection diagram (page 9)
Fig. 1 · 7. Installation and connection
Page 10 of the Basetech TS108B user manual — 7. Installation and connection
Page 10 · cliquer pour agrandir
Page 10

To separate the housing parts, carefully remove the clips to detach the front part (with electronic parts/display). You find both clips in the middle at the left and right of the housing. Push down the housing carefully below the clips and pull the front part of the room thermostat until both housing parts detach from each other.

  • Check whether the place where you intend to install the thermostat has wires and cables under its surface. These can get damaged by drilling.
  • Remove the terminal block on the bottom part of housing and the cover of the screw contacts. Route the cables (from the rear) through the opening of bottom part of housing behind it. The “UP” arrow should point to the ceiling.
  • Use the device as a template and
Basetech TS108B — 7. Installation and connection diagram (page 10)
Fig. 2 · 7. Installation and connection

mark the locations for the borehole on the wall (alternatively, the thermo- stat can be installed on a 60 mm in- wall socket). To do this use the mounting holes in the rear panel suitable for your mounting position. The holes chosen should be located opposite each other to ensure maxi- mum stability.

  • Use a 6 mm drill and bore at least 30 mm deep at the marks.

the material in the installation kit .enclosed may be required. Use the type of installation depending on the conditions.

  • Press the anchors in until they fully disappear into the wall.
Page 11 of the Basetech TS108B user manual — 7. Installation and connection
Page 11 · cliquer pour agrandir
Page 11
  • Feed the cable through the bottom part of housing and secure to the wall with screws. Tighten the screws well. The “UP” arrow should point to the ceiling.
Basetech TS108B — 7. Installation and connection diagram (page 11)
Fig. 3 · 7. Installation and connection
  • Make sure that the cable in the device remains flexible. Install the clamping mechanism again and tighten the two screws.
  • Cut the cables into length and remove the insulation 6 - 7 mm from the ends. Do not damage the wires.
  • The room thermostat has a relay with two potential-free changeover contacts.

COM = middle contact of relay

NO = closing contact (the contact is opened in standby)

NC = opening contact (the contact is closed in standby)

Connect the connector „COM“ with the neutral wire of the power cable.

Depending on the device you want to control with the room thermostat (cool- ing or heating device), the connector „NO“ or „NC“ must be used as switch output.

The connectors are suitable for a cable diameter of 1 to 2.5 mm².

Actual temperature NO output NC output

Heater > Set temperature +1 °C OPEN CLOSE

< Set temperature -1 °C CLOSE OPEN

Cooling system > Set temperature +1 °C CLOSE OPEN

< Set temperature +1 °C OPEN CLOSE

Page 12 of the Basetech TS108B user manual — 7. Installation and connection
Page 12 · cliquer pour agrandir
Page 12
  • The circuit example shows the connection of a device to the NO output of the relay. Depending on the connected heating or cooling device, the NO connector (closing contact) or NC (opening contact) must be used.
Basetech TS108B — 7. Installation and connection diagram (page 12)
Fig. 4 · 7. Installation and connection

The maximally permissible connection values for the electric device

can be found in chapter 13.

  • Open the screws of the contact strip and insert the wires until the insulation is above the edge of the contact surface in the terminal. Hold in position and tighten the screws. If you cannot push the wire into the terminal strip far enough, check the length of the end splice. After assembling, check and re-tighten all the screws.
  • Fasten the cover with screws to front of the contact strip.
  • Insert the switching logic into the wall-mounted front part of housing. Make sure that labels and display are legible and not in an upside down position. If this is the case, the parts are not in proper contact. The switching signals are transferred from the logic to the front part of housing by way of three contacts.
  • Switch the voltage supply back on.
Page 13 of the Basetech TS108B user manual — A B C D E F G H
Page 13 · cliquer pour agrandir
Page 13

8. Control elements

Basetech TS108B — 8. Control elements diagram (page 13)
Fig. 5 · 8. Control elements

A B C D E F G H

A Arrow button F OK button

B SELECT button G HOLD/COPY button

C PROG button H Arrow button

D SET button I Display

E TEMP button

Page 14 of the Basetech TS108B user manual — 7 8 19 20 22 9 21
Page 14 · cliquer pour agrandir
Page 14

9. Indicators elements

13 14 18 5 16 17 11 4 12

Basetech TS108B — 13 14 18 5 16 17 11 4 12 diagram (page 14)
Fig. 6

7 8 19 20 22 9 21

1 Time 12 HOLD icon

2 Day of week 13 Icon for manual step

3 Day programme 14 AUTO setting

4 Temperature setting 15 Battery icon

5 Anti-freeze icon 16 Setting the Comfort Temperature

6 Time setting icon 17 Setting the Semi-comfort Temperature

7 Programme setting icon 18 Setting the Economy Temperature

8 Function setting icon 19 Temperature setting

9 Control “Heating“ 20 COPY function

10 Control “Cooling“ 21 Room temperature icon

11 Holiday mode 22 Off

Page 15 of the Basetech TS108B user manual — a) Setting the time
Page 15 · cliquer pour agrandir
Page 15

10. Operation

Press and hold the “SET” button for 3 seconds to enter the “Time and function setting” menu. Press the “SELECT” button to toggle between “tI” for the clock time setting and “St” for the function setting. Press “SET” to confirm your selec- tion.

a) Setting the time

Press and hold the “SET” button for 3 seconds to set the time. Select “tI” for the clock time setting and confirm your selection as described above.

1. In the first step the current year in the order 2010 to 2050 is set. To add a year, press the “ ” button. To reduce the number of years press the “ “ button. Confirm your setting with the “SELECT” button.
Basetech TS108B — a) Setting the time diagram (page 15)
Fig. 7 · a) Setting the time
2. Next the month is adjusted. Use the “ “ button as described in step 1, and the “ ” button.

Year · Month

Page 16 of the Basetech TS108B user manual — Holiday mode
Page 16 · cliquer pour agrandir
Page 16
3. Weekday, hours and minutes are now adjusted. You can set and select these as described in step 1.

Once the year, month, weekday and clock time are set, the year setting re- starts. If you want to confirm your selection, press the “OK” button. If you want to change your settings, repeat step 1 to 3.

b) Adjusting the functions

Press and hold the “SET” button for 3 seconds to set the function. Select “St” for the function setting and confirm your selection with the “SET” button.

Press the “SELECT“ button to toggle between holiday mode “Ho“ and the heat/ cool mode “Ht“ or “CL“. Confirm your setting with the “SET” button.

Holiday mode Heat/cool mode

Holiday mode

This function maintains the desired temperature consistent for one to 199 days. Use the “ “ and “ “ to increase or decrease the days. Press the “OK” button to confirm your settings. The countdown that runs counts the set number of days down to 0.

Day

Page 17 of the Basetech TS108B user manual — Heat/Cool control
Page 17 · cliquer pour agrandir
Page 17

When the device is in the holiday mode, the set temperature is

maintained while in this mode. Program settings are only obtained when the countdown of the holiday mode is at 0 or the Holiday Mode is reset to 0!

Heat/Cool control

The device can be used to control a heater or a cooler. In heating mode, the ther- mostat switches the connected device off when the target temperature is exceeded.

In cooling mode, the thermostat switches the connected device on when the target temperature underrun.

The operating mode is indicated with the flame symbol (9: heating mode) and the snowflake symbol (10: cooling mode).

Also a delay of 5 minutes can also be set. This is used as switching hysteresis in order to protect the connected devices from too frequent switching.

To make the setting, go to the function settings as described under Holiday mode. Use the buttons “ “ and “ “ to select “Ht“ for the heating or “CL“ for the cooling system. Press “OK” to confirm.

To enable the delay, press and hold the „SET“ button for 3 seconds.

Use “SELECT” to change from the time setting “ti” to the function setting “St” and confirm with “SET”.

Page 18 of the Basetech TS108B user manual — c) Preconfigured temperature setting
Page 18 · cliquer pour agrandir
Page 18

Use „SELECT“ to switch between holiday „Ho“ and heating / cooling „Ht“ or between heating „Ht“ and cooling „CL“ and confirm with „SET“ every time.

Use “SELECT” to toggle between delay (d:ON) and delay off (d:oF). Save and close your settings with “OK”.

c) Preconfigured temperature setting

By means of this setting you can pre-configure the following four temperature functions: Economy temperature, Semi-comfort temperature, Economy tem- perature und Frost protection temperature

Economy temperature Semi-comfort temperature

Economy temperature Frost protection temperature

1 Press and hold the “TEMP” button for 3 seconds to enter the menu. Briefly press the “TEMP” button to be able to toggle between the preconfigured settings.

2 With the buttons “ “ and “ “ you can decrease or increase the tempera- ture in steps of 0.5 °C depending on the setting.

3 Press the “TEMP” button to confirm your setting. Now you can set the next function.

4 Confirm with “OK” and exit the menu.

Page 19 of the Basetech TS108B user manual — d) Programme functions
Page 19 · cliquer pour agrandir
Page 19

d) Programme functions

Press and hold the “PROG” button to enter the program setting menu.

1. Select first your desired program mode.

The following program modes are available:

-- Daily program: The set program is the same for all 7 days of the week. “7” is displayed in

the upper left corner.

-- Weekdays + weekendA program for weekdays and a program for the weekend can be config-

ured. “5 2” is displayed in the upper left corner.

-- Weekdays + Saturday + Sunday: The mode has the same function as b., but the configuration for Saturday

and Sunday differs. “5 1 1” is displayed in the upper left corner.

-- 7-day programAll 7 weekdays can be programmed separately. “7dY” is displayed in the

upper left corner.

-- Press the “PROG” button to confirm your settings.

Daily program Weekdays + Weekend

Weekdays + Saturday + Sunday 7 days program

Page 20 of the Basetech TS108B user manual — d) Programme functions
Page 20 · cliquer pour agrandir
Page 20
2. Next, select the day for your program settings. To do this, press the “SELECT” button. As shown in the image, this allows you to choose, for example, Monday as the first day of your 7-dayprogram. Press the “PROG” button to configure the program for the selected day.
3. Now you can set the program parameters for the selected day. The program setting starts at 0:00 every day.
4. Press the “TEMP” button to set one of the following five functions:

-- Economy temperature two points are shown

-- Semi-comfort temperature one point is shown

-- Economy temperature no point; moon is shown

-- Frost protection temperature no point; snowflake is shown

-- Off no point; Off is shown

5. Press the buttons “ “ and “ “ to select the individual hours. The setting is maintained until you change it by pressing the “TEMP” button.
6. Press the “PROG” button to exit your program settings. Then you can set the remaining days as described in steps 3 to 5.
7. When you choose to have the same program on two days, you can use the “COPY“ function which easily copies programs. Press the “COPY“ button at the start of the program configuration for the day. The display shows the “COPY“ icon. To confirm the copy function, press the “OK” button.

Repeat steps 1 - 7 to configure the remaining days.

Once everything is configured, press the “OK” button to confirm your selection.

Page 21 of the Basetech TS108B user manual — e) Program overview
Page 21 · cliquer pour agrandir
Page 21

e) Program overview

With the program overview, you can recall and check programs already config- ured.

1. Press and hold the “PROG” button to enter the program settings menu. Press the “SELECT” button 4 times until “7AY” is shown on the display.
Basetech TS108B — e) Program overview diagram (page 21)
Fig. 8 · e) Program overview
2. Press the “PROG” button to set the day for the overview. Use the “SELECT” button to toggle between the days.
3. By pressing the “PROG” button again, you can call up the program overview for the selected day. With the “ “ and “ “ buttons to are able to control each hour within the program.
4. To return to the program setting menu, press the “PROG” button again. Then press the “OK” button to return to the display.
Page 22 of the Basetech TS108B user manual — f) Manual settings
Page 22 · cliquer pour agrandir
Page 22

f) Manual settings

By means of the manual settings you can edit and change configured programs.

  • Editing the current program temperature status: Press the “TEMP” button to toggle between the various temperature functions. The program temperature status will be applied during the next hour. The symbol for the manual steps appears on the display.
  • Temperature change: You can decrease or increase the temperature with the buttons “ “ and “ “. Also these changes will be applied during the next hour. The icon for the manual steps appears on the display.
  • Maintaining the selected temperature: Press and hold the “HOLD” button for 3 seconds. Use the buttons “ “ and “ “ to set the duration during which the temperature should be kept. You can choose a time span of 1 to 99 hours. To confirm your choice, press the “OK” button. The display shows “HOLD”.
  • Y ou can also make a choice between AUTO/OFF/ Anti-Frozen . Press and hold the MANUAL button for 3 seconds. Press the “SELECT” to select the following:
Basetech TS108B — f) Manual settings diagram (page 22)
Fig. 9 · f) Manual settings

OFF - system will turn off ON - system remains on

Press the “OK” button to confirm your settings.

Page 23 of the Basetech TS108B user manual — g) Battery
Page 23 · cliquer pour agrandir
Page 23

g) Battery

When the battery is almost empty, the bat- tery icon appears on the display . If this is the case, you need to change the device batteries soon.

You will loose your settings, if the power supply to the room thermo-

stat is interrupted.

Page 24 of the Basetech TS108B user manual — a) Connecting your phone to the thermostat
Page 24 · cliquer pour agrandir
Page 24

11. Using the mobile app

a) Connecting your phone to the thermostat

Install the “BLUE STAT“ app on your smartphone. The app is available for iOS and Android devices.

If you are using an Android device, check that you are running An-

droid 4.3 or later.

When you open the app, your phone will automatically search for the thermostat and establish a connection. “Connecting OK“ will be displayed once the connec- tion has been established.

After configuring the settings, touch “OK“ in the lower-left corner of

the screen to apply the settings and send them to the thermostat. “Send Ok/Confirm“ will be displayed once the settings have been sent successfully.

Basetech TS108B — a) Connecting your phone to the thermostat diagram (page 24)
Fig. 10 · a) Connecting your phone to the thermostat
Basetech TS108B — a) Connecting your phone to the thermostat diagram (page 24)
Fig. 11 · a) Connecting your phone to the thermostat

Apple Store Google Play

Page 25 of the Basetech TS108B user manual — b) Setting the temperature
Page 25 · cliquer pour agrandir
Page 25

b) Setting the temperature

Basetech TS108B — b) Setting the temperature  diagram (page 25)
Fig. 12 · b) Setting the temperature

You can set the temperature in two ways:

-- Manually set the temperature ac-

cording to your needs. Move the slider to the desired setting.

-- Set the temperature using a preset

Basetech TS108B — b) Setting the temperature  diagram (page 25)
Fig. 13 · b) Setting the temperature

mode. Press the middle button on the display to select a preset mode. Refer to “Operation - predefined tem- perature settings“ for more informa- tion. There are four preset modes: Economy temperature, Semi-comfort temperature, Economy temperature and Frost protection temperature.

Page 26 of the Basetech TS108B user manual — c) Changing the thermostat mode
Page 26 · cliquer pour agrandir
Page 26

c) Changing the thermostat mode

There are four different heating modes:

Basetech TS108B — c) Changing the thermostat mode diagram (page 26)
Fig. 14 · c) Changing the thermostat mode
-- AUTOThe temperature is set us-

ing the preset program.

-- ANTI-FROZENThe room is main-

tained at a low temperature to pre- vent frost.

-- TURBO: The heating is on full.

-- OFF: The heating is switched off.

To change to another mode, touch the left-hand button.

Page 27 of the Basetech TS108B user manual — d) “Temperature hold” and “Holiday mode”
Page 27 · cliquer pour agrandir
Page 27

d) “Temperature hold” and “Holiday mode”

“Temperature hold” maintains the room at a preset temperature for a predefined period of time

Touch the “HOLD/VACATION” button on the right-hand side of the display, and then drag the slider to set the time.

Basetech TS108B — d) “Temperature hold” and “Holiday mode” diagram (page 27)
Fig. 15 · d) “Temperature hold” and “Holiday mode”

Set the desired temperature

before touching the “HOLD/ VACATION” button. No other preset programs will be used when this mode is enabled. The temperature can be maintained for a du- ration of 1 to 90 hours.

To configure holiday mode, touch the HOLD/VACATION button and select “Holiday” at the top of the screen. Drag the slider in the middle of the screen to set the duration of your holiday.

Basetech TS108B — d) “Temperature hold” and “Holiday mode” diagram (page 27)
Fig. 16 · d) “Temperature hold” and “Holiday mode”

The room will be kept at the preset tem- perature for the duration of your holiday. You can choose a duration from 1 to 199 days.

Page 28 of the Basetech TS108B user manual — Preset temperature settings
Page 28 · cliquer pour agrandir
Page 28

e) Advanced settings

To access the advanced settings, touch the settings icon in the lower-left corner of the display.

Basetech TS108B — e) Advanced settings diagram (page 28)
Fig. 17 · e) Advanced settings

You can change the program settings and preset temperature. You can also view your energy footprint and control data. Touch the corresponding option to access the settings.

Preset temperature settings

This menu allows you to manually set the temperature for the follow- ing modes: Economy temperature, Semi-comfort temperature, Econo- my temperature and Frost protection temperature. Keep touching the the left-hand button until the desired mode is displayed. Drag the slider in the middle of the display to set the temperature. To exit the menu, touch the arrow at the top of the display.

Basetech TS108B — Preset temperature settings diagram (page 28)
Fig. 18 · Preset temperature settings
Page 29 of the Basetech TS108B user manual — Program review
Page 29 · cliquer pour agrandir
Page 29

Program control

This menu allows you to view and change the program settings. Touch the cor- responding option to access the settings. To exit the menu, touch the arrow at the top of the display.

Program review

This menu allows you to view your preset program settings. Select the day for which you want to view the program settings.

Basetech TS108B — Program review diagram (page 29)
Fig. 19 · Program review

Touch the corresponding day of the week at the top of the display. The program settings are displayed in dif- ferent colours (the preset temperature settings).

Page 30 of the Basetech TS108B user manual — Program setting
Page 30 · cliquer pour agrandir
Page 30

Program setting

Use this menu to configure existing programs or add new programs.

Basetech TS108B — Program setting diagram (page 30)
Fig. 20 · Program setting

Touch the day of the week for which you want to configure the program. You can select more than one day.

Touch the desired mode (Economy temperature, Frost protection tem- perature etc.). The selected button will be highlighted. To set the time period, drag the slider to the desired position. Repeat this step to configure addi- tional time periods.

Touch “OK” in the lower-right corner of the display to apply the settings. To exit the menu, touch the arrow at the top of the display.

Touch “HOME” to access

the home page.

Page 31 of the Basetech TS108B user manual — 12. Maintenance and care
Page 31 · cliquer pour agrandir
Page 31

Control data

This menu allows you to control the heating using “Cooling” or “Heating”. Refer to the operating instructions for more information.

Basetech TS108B — Control data diagram (page 31)
Fig. 21 · Control data

12. Maintenance and care

  • If the display contrast decreases or the time display stops, the batteries are flat and must be replaced. To do this, detach the front part of the housing by releasing the clips carefully (they are situated in the middle on the left and right side). Press under the clips and pull the front part of the housing slowly away.

Replace the exhausted batteries for new ones; dispose of the old batteries in an environmentally correct way.

Close the housing of the room thermostat again.

  • To clean the outside of the product, a dry, clean and lint-free cloth is sufficient.
  • Do not use any aggressive cleaning agents or chemicals. Improper cleaning agents can cause discolouration on the plastic surface or damage the lettering. Never use aggressive scouring cleaners, alcohol, gasoline, spirit or similar liquids for cleaning the device!
Page 32 of the Basetech TS108B user manual — b) Disposal of used batteries/rechargeable batteries
Page 32 · cliquer pour agrandir
Page 32

13. Disposal

a) General information

The product must not be disposed of in the household waste.

Dispose of the product at the end of its serviceable life in accord-

ance with the current statutory requirements; e.g., return it to any suitable collection point.

Remove any normal or rechargeable batteries inserted and dispose of them sepa- rately from the product.

b) Disposal of used batteries/rechargeable batteries

As the end user, you are required by law (Battery Ordinance) to return all spent rechargeable batteries; disposal of them in the household waste is prohibited!

Contaminated rechargeable batteries are labelled with these sym-

bols to indicate that disposal in the domestic waste is forbidden. The symbols of the critical heavy metals are: Cd = Cadmium, Hg = Mer- cury, Pb = Lead. You can return used rechargeable batteries free of charge, to any collection facility in your local authority, to our stores or to any other store where rechargeable batteries are sold.

You thereby fulfil your statutory obligations and contribute to the protection of the environment!

Page 33 of the Basetech TS108B user manual — Storage conditions
Page 33 · cliquer pour agrandir
Page 33

14. Technical data

Bluetooth® 4.0

Rated voltage 230 V/AC, 50 Hz

Adjustable temperature +5 °C to +30 °C

Accuracy (control) ± 1 °C at 20 °C

Power 2x AA batteries (not included)

Battery discharge within 6 months

Connection power Ohmic load: 1840 W (230 V/AC, 8 A)

Inductive load460 W (230 V/AC, 2 A)

Changeover contact Relay, single-pole, potential-free

Transmission frequency 2.4 GHz

Transmission power 4 dBm

Supported operating systems from iOS 7.2, Android 4.2 or higher

Operating conditions

Temperature 0 °C to +40 °C

Humidity 15% to 95% relative, non-condensing

Storage conditions

Temperature -15 °C to +65 °C

Humidity 15% to 95% relative, non-condensing

Dimensions (W x H x D) 126 x 86 x 31 mm

Weight 0.165 kg

changeover contact

Page 34 of the Basetech TS108B user manual — 15. Declaration of conformity (DOC)
Page 34 · cliquer pour agrandir
Page 34

15. Declaration of conformity (DOC)

Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby de- clares that this product complies with directive 2014/53/EU.

The complete text of the EU declaration of conformity is available under the following web address:

www.conrad.com/downloads

Choose a language by clicking a flag symbol and enter the order number of the product into the search field; then you may download the EU declaration of conformity in the PDF format.

Page 35 of the Basetech TS108B user manual — 15. Declaration of conformity (DOC)
Page 35 · cliquer pour agrandir
Page 35
Page 35 of the Basetech TS108B user manual — 15. Declaration of conformity (DOC)

Poser une question sur : Basetech TS108B

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Basetech TS108B

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Basetech TS108B manuel PDF

110 pages·4.4 MB·Thermostat·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…