ACM 15 E/ER ACM 20 E/ER ACM 25 E/ER ACM 28 E/ER
A5CM 15 E/ER A5CM 20 E/ER A5CM 25 E/ER A5CM 28 E/ER




ACM - E2007



Indoor
Others
Other Specifications
I : Ionizer Generator N : Non Thermal Plasma
Controller Specifications
G : Wireless handset S : SLM3 N : Netware III
Market Region
C : Export with CE mark
Electrical
A : 220 - 240V/1Ph/50Hz
A CM 20 E R
G I A C A -
Model Type
R : heatpump Omitted if Cooling Only
Series
E : E series
Capacity
20 : 20,000 Btu/h
Model Name
CM : Ceiling Convertible
Refrigerant
5 : R410A Omitted if R22 model
Brand
A : ACSON

Others
Specifications Variation
O : Standard unit I : Gold Fin B : With Contactor L : Long Piping Unit G : Low Ambient Unit S : With H/L Pressure Switch H : High ambient unit X :Oxygen Unit
Market Region
C : Export with CE marking E : Export without marking U : ETL Spec.
A LC 20 C R
5 P O A C A -
Model Type
R : heatpump Omitted if Cooling
Series
C : C series
Capacity
20 : 20,000 Btu/h
Model Name
LC : Single Split Condensing unit
Refrigerant
5 : R410A Omitted if R22 model
Brand
A : ACSON

Ceiling And Floor Installation Option The unit is uniquely designed with the option to install either below the ceiling or mounted at low wall position without any modification needed. Furthermore, the unit is design adds a touch of elegance to suit any interior design requirement
Excellent Air Distribution The louver with automatic air swing function fully optimize the room comfort by enables the air flow to be evenly distributed into the room from the front discharge area.
Negative Ion Generator ACSON emphasis on provide indoor air quality solution. Therefore, the negative ionizer technology is being brought in as an essential part of the unit. The negative ion generator increases the amount of negative ion in the air-conditioning area, creating a refreshing and healthy living environment.
Easy Installation The ceiling convertible fan coil unit is easily installed with a very economical and space saving installation. No need renovation on wall or ceiling for installation. This easy to install and ready to operate unit ensure rapid and low installation cost.
Magnificent Serviceability The blower, fan motor assembly and electrical parts can be inspected and air filter can be accessed by pulling down the air intake grille. During servicing or repairing, only the bottom panel needs to be removed in order to access the fan motor, blower, control box piping connection and drain pan.
Wireless Remote Controller The standard unit comes with a simple, user friendly and stylish wireless controller. The G12 controller offers many features:
Auto Random Restart Auto random restart function allows the unit to automatic restart as the last setting condition when the power supply is resumed after power failure. However, the compressor will restart randomly if more than one unit is installed and sharing the same phase of power.
Self Diagnosis The microprocessor provides the possibility to detect and diagnose any fault or malfunction that occurs in the system. The error will be reflected by the blinking of the LED lights.

Operating Range
Ensure the operating temperature is in allowable range.


The use of your air conditioner outside the range of working temperature and humidity can result in serious failure.
Heatpump
Heating
Cooling


Outdoor temp. (°CDB)
Indoor temp. (°CDB)
Indoor temp. (°CWB)
Note :
Standard operating range.
With High ambient unit. (Optional item) Please refer to local dealer for unit of this specification.
With Low ambient kit. (Optional item) Please refer to local dealer for unit of this specification.

MODEL : ACM / A5CM 15E - ALC / A5LC 15C ACM 20E - ALC 18C ACM / A5CM 20E - ALC / A5LC 20C A5CM 25E - A5LC 25C

A5CM 28E - A5LC 28C








A5CM 25ER - A5LC 25CR








G12 Remote Controller
Personalised Setting

OFF Timer Setting
Clock Time Setting • Press button + or - to increase or decrease the clock time.
Sleep Mode



Cooling Only Heatpump
HEAT FAN COOL DRY
FAN COOL DRY
Normal Operation / Fault Indication
|
Cool mode
|
Heat mode
|
Dry mode
|
Fan mode
|
Auto mode in cooling operation
|
Auto mode in heating operation
Room air sensor open or short
Indoor coil sensor open or short
Outdoor coil sensor open or short
Compressor overload / indoor coil sensor short / outdoor coil sensor short
Gas leak
| - ON
- Blinking

Blink E1 Room sensor open or short
Blink E2 Indoor coil sensor open
Blink E3 Outdoor coil sensor open
Compressor overload /
Blink E4
Indoor coil sensor short /
Outdoor coil sensor short
Blink E5 Gas leak
Blink E6 Water pump faulty
Phase Sequencer
LED_P LED_R LED_S LED_T
(Red) (Yellow) (Yellow) (Yellow)
Normal Operation On - - -
Reverse Phase Blink Blink Blink Blink
S & T Phase Missing Blink - Blink Blink
T Phase Missing Blink - - Blink
S Phase Missing Blink - Blink -
R Phase Missing - - - -
Overload Blink - - -
Sensor Missing Blink On On On

Caution
Sharp edges and coil surfaces are potential injury hazard. Avoid from contact with them.
Standard Mounting Ensure that the overhead supports are strong enough to hold the weight of the unit. Position the hanger rods (wall mounting bracket for floor standing), and check for its alignment with the unit as shown in Figure A. Also, check that the hangers are secured and the base of the fan coil unit is leveled in both horizontal directions, taking into account the gradient for drainage flow as recommended in Figure B.







Figue C

Install the Suspension Bolts






Under Ceiling Type







1. Remove the air inlet grille by both hands as the direction shown. 2. Loosen the screws for fixing the panel arm (3 screws - Left, Right and Center). Do not remove the screws at this time. 3. Move the air inlet grille upward, and then turn it backwards. (Do not use too much force). 4. Remove the grille holder (both left and right side). After that, remove the air intake grille. 5. Remove the grille holder (center) from the panel.




To Adjust the Vane Direction Adjust the vane linkage as the direction shown to get the required vane direction.



(2) Installation Of Outdoor Unit As condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achieve maximum cooling capacity, the location selected for outdoor unit should fulfill the following requirements :





Installation Clearance • Outdoor units must be installed such that there is no short circuit of the hot discharge air or obstruction to smooth air flow. Select the coolest possible place where intake air should not be hotter than the outside temperature (max. 45°C)


Minimum Distance 300 mm 1000 mm 300 mm 500 mm

Maximum Piping Length And Maximum Number Of Bends When the pipe length becomes too long, both the capacity and reliability drop. As the number of bends in- creases, system piping resistance to the refrigerant flow increases, thus lowering the cooling capacity, and as the result the compressor may become defective. Always choose the shortest path and follow the recommen- dation as tabulated below:
28E/ER
Model
Outdoor 15C/CR 18 / 20C/CR 25C/CR 28C/CR 30 / 35C/CR
Maximum Length, m
12 15 15 15 45
Maximum Elevation, m
5 8 8 8 25
10 10 10 10 10 Maximum No. of Bends
Piping Sizes (Flare Connection Type) Piping sizes are as follows:
R22
Model ALC 15C/CR ALC 18/20C/CR ALC 25C/CR ALC 28C/CR ALC 30C/CR
Liquid (mm/in) 6.35 / 1/4 6.35 / 1/4 9.52 / 3/8 9.52 / 3/8 9.52 / 3/8
Suction (mm/in) 12.70 / 1/2 15.88 / 5/8 15.88 / 5/8 15.88 / 5/8 15.88 / 5/8
Model A5LC 15C/CR A5LC 20C/CR A5LC 25C/CR A5LC 28C/CR A5LC 35C/CR
Liquid (mm/in) 6.35 / 1/4 6.35 / 1/4 6.35 / 1/4 9.52 / 3/8 9.52 / 3/8
Suction (mm/in) 12.70 / 1/2 12.70 / 1/2 15.88 / 5/8 15.88 / 5/8 15.88 / 5/8
6.35 (1/4) 18
9.52 (3/8) 42
12.70 (1/2) 55
15.88 (5/8) 65
19.05 (3/4) 78


Electrical Connections • Wiring regulations on wire diameters differ from country to country. Please refer to your LOCAL ELECTRI- CAL CODES for field wiring rules. Be sure that installations comply with the rules and regulations.
The pre-charged outdoor unit does not need any vacuuming or charging. However once it is connected, the connecting pipe line and the indoor unit need to be vacuumed before releasing the R22/R407C/R410A from the outdoor unit. 1. Open the service port core cap. 2. Connect pressure gauge to the service port. 3. Connect the line to vacuum pump. Open the charging manifold valve and turn the pump on. Vacuum to - 0.1 MPa (-760mmHg) or lower. (Evacuation time varies by the pump but averagely in 1 hour).

R22 - Nil R410A - Nil
Model 10m 12m 15m 25m 35m 45m
ALC 15C/CR 37 / 57 68 / 104 -
ALC 18C/CR 38 / 54 70 / 98 118 / 166 - - -
ALC 20C/CR 38 / 53 70 / 96 118 / 162 - - -
ALC 25C/CR 94 / 53 172 / 98 289 / 164 - - -
ALC 28C/CR 94 / 133 172 / 244 291 / 411 - - -
ALC 30C/CR 133 / 133 244 / 243 410 / 409 964 / 961 1518 / 1514 2072 / 2067
Model 10m 15m 20m 25m 35m 45m
A5LC 15C/CR 20 / 39 37 / 71 -
A5LC 20C/CR 24 / 40 44 / 73 74 / 123 - - -
A5LC 25C/CR 24 / 23 45 / 43 75 / 72 - - -
A5LC 28C/CR 58 / 91 106 / 167 178 / 281 - - -
A5LC 35C/CR 65 / 98 118 / 180 199 / 303 469 / 712 738 / 1122 1007 / 1531
The additional refrigerant charge amount recommended is a guideline for longer piping application. The actual charge required may be different from the guideline due to different application and variation in site conditions.


R22 - Nil R410A - Nil
Temperature Ts ˚C / ˚F Th ˚C / ˚F
Maximum Indoor Temperature 26.7 / 80.1 19.4 / 66.9
Minimum Outdoor Temperature 19.4 / 66.9 13.9 / 57.0
Maximum Outdoor Temperature 46 / 114.8 24 / 75.2
Heat Pump Unit
Temperature Ts ˚C / ˚F Th ˚C / ˚F
Maximum Indoor Temperature 26.7 / 80.1 -
Minimum Outdoor Temperature -8 / 17.6 -9 / 15.8
Maximum Outdoor Temperature 24 / 75.2 18 / 64.4

i) What Is New Refrigerant R410A?
R410A is a new HFC refrigerant which does not damage the ozone layer. The working pressure of this new refrigerant is 1.6 times higher than conventional refrigerant (R22), thus proper installation / servicing is essential.
Mixture weight composition R32(50%) and R125(50%)
i) Manifold gauge and charging hose ii) Gas leak detector iii) Refrigerant cylinder/charging cylinder iv) Vacuum pump c/w adapter v) Flare tools vi) Refrigerant recovery machine
v) Handling And Installation Guidelines Like R22 system, the handling and installation of R410A system are closely similar. All precautionary measures; such as ensuring no moisture, no dirt or chips in the system, clean brazing using nitrogen, and thorough leak check and vacuuming are equally important requirements. However, due to its hydroscopic POE oil, additional precautions must be taken to ensure optimum and trouble free system operation.
a) During installation or servicing, avoid prolong exposure of the internal part of the refrigerant system to
moist air. Residual POE oil in the piping and components can absorb moisture from the air.
b) Ensure that the compressor is not expose to open air for more than the recommended time specified by its manufacturer (typically less than 10 minutes). Removed the seal plugs only when the compressor is about to be brazed.
c) The system should be thoroughly vacuumed to 1.0 Pa ( 700mmHg) or lower. This vacuuming level is more stringent than R22 system so as to ensure no incompressible gas and moisture in the system.

d) When charging R410A, ensure that only liquid is being withdrawn from the cylinder or can. This is to ensure that only the original composition of R410A is being delivered into the system. The liquid composition can be different from the vapor composition.


Dip-pipe
Liquid withdrawal
f) Normally, the R410A cylinder or can is being equipped with a dip pipe for liquid withdrawal. However, if the dip pipe is not available, invert the cylinder or can so as to withdraw liquid from the valve at the bottom.

GENERAL DATA - COOLING ONLY (R22)



V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
48 / 46 / 43 SOUND PRESSURE LEVEL (H/M/L)




V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
l/s / CFM 741 / 1570 1605 / 3400


1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.


V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.


1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.


V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
l/s / CFM 741 / 1570 1605 / 3400
kg/lb 2.40 / 5.30 2.15 / 4.12 REFRIGERANT CHARGE
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.


48 / 43 / 41 SOUND PRESSURE LEVEL (H/M/L)


l/s / CFM 245 / 520 274 / 580
l/s / CFM 217 / 460 250 / 530
l/s / CFM 192 / 406 231 / 490
EXTERNAL STATIC PRESSURE (H/M/L) Pa / in.wg. 0 0
dBA 48 / 46 / 43 50 / 47 / 46
l/s / CFM 614 / 1300 689 / 1460
GAS mm/in 12.7 / 1/2 15.9 / 5/8 kg/lb 1.40 / 3.09 1.65 / 3.64 REFRIGERANT CHARGE


l/s / CFM 684 / 1450 1605 / 3400
GAS mm/in 15.9 / 5/8 15.9 / 5/8 kg/lb 1.70 / 3.75 1.90 / 4.19 REFRIGERANT CHARGE


1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.


NOMINAL TOTAL INPUT POWER (COOLING) - 1Ø / <3Ø>
NOMINAL TOTAL INPUT POWER (HEATING) - 1Ø / <3Ø>
l/s / CFM 245 / 520 274 / 580
l/s / CFM 217 / 460 250 / 530
l/s / CFM 192 / 406 231 / 490
EXTERNAL STATIC PRESSURE (H/M/L) Pa / in.wg. 0 0
dBA 48 / 46 / 43 50 / 47 / 46
l/s / CFM 614 / 1300 689 / 1460
GAS mm/in 12.7 / 1/2 15.9 / 5/8 kg/lb 1.40 / 3.09 1.65 / 3.64
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.


NOMINAL TOTAL INPUT POWER (COOLING) - 1Ø / <3Ø>
NOMINAL TOTAL INPUT POWER (HEATING) - 1Ø / <3Ø>
l/s / CFM 684 / 1450 1605 / 3400
GAS mm/in 15.9 / 5/8 15.9 / 5/8 kg/lb 1.70 / 3.75 1.90 / 4.19
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.








ATMOS M60 or SUNISO 4GDID MINERAL (Sontex 200 LT)
cm3 / fl.oz. 1130 / 39.8 1240 / 43.6
m2/ft2 0.61 / 6.52 0.87 / 9.33








ATMOS M60 or SUNISO 4GDID MINERAL (Sontex 200 LT)
cm3 / fl.oz. 1130 / 39.8 1240 / 43.6
m2/ft2 0.61 / 6.52 0.87 / 9.33




cm3 / fl.oz. 670 / 23.6 1130 / 39.8
m2/ft2 0.510 / 5.460 0.620 / 6.630


cm3 / fl.oz. 1130 / 39.8 1242 / 43.7
m2/ft2 0.620 / 6.630 0.87 / 9.33




cm3 / fl.oz. 670 / 23.6 1130 / 39.8
m2/ft2 0.510 / 5.460 0.620 / 6.630


cm3 / fl.oz. 1130 / 39.8 1242 / 43.7
m2/ft2 0.620 / 6.630 0.87 / 9.33





DISCHARGE THERMOSTAT SETTING - 1Ø / <3Ø> °C / °F N/A N/A /





DISCHARGE THERMOSTAT SETTING - 1Ø / <3Ø> °C / °F N/A N/A /



DISCHARGE THERMOSTAT SETTING - 1Ø / <3Ø> °C / °F

DISCHARGE THERMOSTAT SETTING - 1Ø / <3Ø> °C / °F

DISCHARGE THERMOSTAT SETTING - 1Ø / <3Ø> °C / °F N/A / N/A /



DISCHARGE THERMOSTAT SETTING - 1Ø / <3Ø> °C / °F

DISCHARGE THERMOSTAT SETTING - 1Ø / <3Ø> °C / °F

DISCHARGE THERMOSTAT SETTING - 1Ø / <3Ø> °C / °F N/A / N/A /

Interpolation and Extrapolation method can be used to get the total capacity, Q and sensible capacity, SC at those temperatures which are not stated out in the table.
Model: ACM 15E / ALC 15C Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 37°C DB
1. Refer to the Indoor DB column,
- 23°C is located between 20°C and 24°C (Thus, Interpolation need to be applied)
- 15°C only available in the case of Indoor DB = 20°C. (Thus, Extrapolation between 16°C WB and 17°C WB during 24°C indoor DB is required)
- 37°C is located between 35°C and 40°C. (Thus, Interpolation need to be applied)
Please follow the steps below in order to get the required capacity.
2 nd Step Interpolation of Indoor DB
3 rd Step Interpolation of Outdoor DB
Find TC, SC for (a) Indoor : 24°C DB, 15°C WB
Find TC, SC for (a) Indoor : 23°C DB , 15°C WB
Find TC, SC for (a) Indoor : 23°C DB, 15°C WB
Outdoor : 35°C DB
Outdoor : 35°C DB
Outdoor : 37°C DB
(b) Indoor : 24°C DB, 15°C WB
(b) Indoor : 23°C DB , 15°C WB
Outdoor : 40°C DB
Outdoor : 40°C DB

1 st Step:
To obtain the Total capacity and Sensible capacity for
(a) Indoor Condition: 24°C DB, 15°C WB
Outdoor Condition: 35°C DB
Outdoor DB ° C Indoor DB Indoor WB 35 ° C ° C TC (kW) SC (kW)
Total capacity, TC
⇒ x1 = 3.295kW (Same as Total capacity at 20°C Indoor DB / 15°C Indoor WB & 35°C Outdoor WB)*
Extrapolation Method:
⇒
17°C - 15°C = 2.288kW - y1 17°C - 16°C 2.288kW - 2.381kW
(b) Indoor Condition: 24°C DB, 15°C WB
Outdoor Condition: 40°C DB
Outdoor DB ° C Indoor DB Indoor WB 40 ° C ° C TC (kW) SC (kW)
Total capacity, TC
⇒ x2 = 2.995kW (Same as Total capacity at 20°C Indoor DB / 15°C Indoor WB & 40°C Outdoor WB)*
Extrapolation Method:
⇒
17°C - 15°C = 1.954kW - y2 17°C - 16°C 1.954kW - 2.056kW
* This is due to 2 different conditions with same WB temperature, will have the same level of enthalpy. For more details, please refer to psychrometrics chart

To obtain the Total capacity and Sensible capacity for
(a) Indoor Condition: 23°C DB , 15°C WB Outdoor Condition: 35°C DB
Outdoor DB ° C Indoor DB Indoor WB 35 ° C ° C TC (kW) SC (kW)
20 15 3.295 1.510 23 15 x3 y3 24 15 3.295 2.474
⇒ x3 = 3.295kW (Same as Total capacity at 20°C Indoor DB / 15°C Indoor WB & 35°C Outdoor WB)*
Interpolation Method:
⇒
24°C - 20°C = 2.474kW - 1.510kW 24°C - 23°C 2.474kW - y3
(b) Indoor Condition: 23°C DB , 15°C WB
Outdoor Condition: 40°C DB
Outdoor DB ° C Indoor DB Indoor WB 40 ° C ° C TC (kW) SC (kW)
20 15 2.995 1.195 23 15 x4 y4 24 15 2.995 2.158
⇒ x4 = 2.995kW (Same as Total capacity at 20°C Indoor DB / 15°C Indoor WB & 40°C Outdoor WB)*
Interpolation Method:
24°C - 20°C = 2.158kW - 1.195kW 24°C - 23°C 2.158kW - y4
⇒ y 4 = 1.917kW
* This is due to 2 different conditions with same WB temperature will have the same level of enthalpy. For more details, please refer to psychrometrics chart

To obtain the Total capacity and Sensible capacity for
(a) Indoor Condition: 23°C DB, 15°C WB
Outdoor Condition: 37°C DB
Outdoor DB ° C Indoor DB Indoor WB 35 37 40 ° C ° C TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW)
Total capacity, TC
Interpolation Method:
40°C - 35°C = 2.995kW - 3.295kW 40°C - 37°C 2.995kW - x
⇒ x = 3.175kW
Sensible capacity, SC
Interpolation Method:
40°C - 35°C = 1.917kW - 2.233kW 40°C - 37°C 1.917kW - y
⇒ y = 2.107kW

MODEL : ACM 15E / ALC 15C
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 4.198 2.455 3.897 2.140 3.596 1.825 3.295 1.510 2.995 1.195 2.634 0.816
16 4.255 2.390 3.958 2.065 3.660 1.741 3.363 1.417 3.066 1.093 2.709 0.704
16 4.255 3.353 3.958 3.029 3.660 2.705 3.363 2.381 3.066 2.056 2.709 1.667
17 4.313 3.288 4.019 2.955 3.725 2.621 3.431 2.288 3.137 1.954 2.784 1.554
18 4.370 3.224 4.080 2.881 3.789 2.538 3.498 2.195 3.208 1.853 2.859 1.441
19 4.428 3.159 4.140 2.807 3.853 2.455 3.566 2.103 3.279 1.751 2.934 1.328
20 4.486 3.095 4.207 2.744 3.928 2.393 3.649 2.042 3.370 1.691 3.036 1.270
18 4.370 4.187 4.080 3.844 3.789 3.502 3.498 3.159 3.208 2.816 2.859 2.405
19 4.428 4.122 4.140 3.770 3.853 3.418 3.566 3.066 3.279 2.714 2.934 2.292
20 4.486 4.059 4.207 3.708 3.928 3.357 3.649 3.006 3.370 2.655 3.036 2.234
21 4.544 3.996 4.277 3.653 4.010 3.310 3.742 2.967 3.475 2.624 3.154 2.213
22 4.603 3.933 4.347 3.598 4.091 3.263 3.836 2.928 3.580 2.593 3.273 2.192
23 4.661 3.870 4.417 3.543 4.173 3.216 3.929 2.890 3.685 2.563 3.392 2.170
24 4.720 3.807 4.487 3.489 4.255 3.170 4.022 2.851 3.790 2.532 3.511 2.149
20 4.540 4.540 4.207 4.190 3.928 3.839 3.649 3.488 3.370 3.137 3.036 2.716
21 4.544 4.478 4.277 4.135 4.010 3.792 3.742 3.449 3.475 3.106 3.154 2.695
22 4.603 4.415 4.347 4.080 4.091 3.745 3.836 3.410 3.580 3.075 3.273 2.673
23 4.661 4.352 4.417 4.025 4.173 3.698 3.929 3.371 3.685 3.044 3.392 2.652
24 4.720 4.289 4.487 3.970 4.255 3.651 4.022 3.333 3.790 3.014 3.511 2.631
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 5.742 3.706 5.396 3.412 5.049 3.117 4.702 2.822 4.355 2.528 3.939 2.174
16 5.967 3.456 5.597 3.186 5.227 2.916 4.857 2.646 4.487 2.376 4.043 2.052
16 5.967 4.367 5.597 4.097 5.227 3.827 4.857 3.557 4.487 3.287 4.043 2.963
17 6.192 4.116 5.799 3.871 5.406 3.626 5.013 3.381 4.620 3.136 4.148 2.842
18 6.417 3.866 6.001 3.645 5.585 3.425 5.168 3.205 4.752 2.985 4.252 2.720
19 6.643 3.615 6.203 3.420 5.763 3.224 5.324 3.029 4.884 2.833 4.357 2.599
20 6.869 3.364 6.415 3.189 5.962 3.013 5.509 2.838 5.055 2.663 4.511 2.453
18 6.417 4.776 6.001 4.556 5.585 4.336 5.168 4.116 4.752 3.895 4.252 3.631
19 6.643 4.526 6.203 4.330 5.763 4.135 5.324 3.940 4.884 3.744 4.357 3.510
20 6.869 4.275 6.415 4.099 5.962 3.924 5.509 3.749 5.055 3.574 4.511 3.363
21 7.096 4.023 6.635 3.865 6.174 3.707 5.713 3.549 5.252 3.390 4.699 3.200
22 7.323 3.772 6.854 3.631 6.386 3.489 5.917 3.348 5.449 3.207 4.887 3.037
23 7.549 3.520 7.073 3.396 6.598 3.272 6.122 3.148 5.646 3.023 5.074 2.874
24 7.776 3.269 7.293 3.162 6.809 3.055 6.326 2.947 5.842 2.840 5.262 2.711
20 6.869 4.730 6.415 4.555 5.962 4.380 5.509 4.204 5.055 4.029 4.511 3.819
21 7.096 4.479 6.635 4.320 6.174 4.162 5.713 4.004 5.252 3.846 4.699 3.656
22 7.323 4.227 6.854 4.086 6.386 3.945 5.917 3.803 5.449 3.662 4.887 3.493
23 7.549 3.976 7.073 3.852 6.598 3.727 6.122 3.603 5.646 3.479 5.074 3.330
24 7.776 3.724 7.293 3.617 6.809 3.510 6.326 3.403 5.842 3.295 5.262 3.167
Outdoor DB°C · Outdoor DB°C

MODEL : ACM 20E / ALC 20C
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 5.850 3.645 5.531 3.384 5.213 3.123 4.894 2.862 4.575 2.602 4.193 2.288
16 6.081 3.339 5.746 3.114 5.410 2.889 5.074 2.664 4.738 2.439 4.335 2.169
16 6.081 4.310 5.746 4.085 5.410 3.860 5.074 3.635 4.738 3.410 4.335 3.140
17 6.313 4.004 5.960 3.814 5.607 3.625 5.254 3.436 4.900 3.247 4.477 3.020
18 6.544 3.697 6.174 3.544 5.804 3.391 5.433 3.238 5.063 3.085 4.619 2.901
19 6.776 3.391 6.388 3.274 6.001 3.157 5.613 3.039 5.226 2.922 4.761 2.781
20 7.008 3.084 6.605 2.993 6.202 2.902 5.800 2.811 5.397 2.720 4.914 2.610
18 6.544 4.668 6.174 4.515 5.804 4.362 5.433 4.209 5.063 4.055 4.619 3.872
19 6.776 4.362 6.388 4.245 6.001 4.127 5.613 4.010 5.226 3.893 4.761 3.752
20 7.008 4.054 6.605 3.963 6.202 3.872 5.800 3.781 5.397 3.690 4.914 3.581
21 7.240 3.746 6.823 3.675 6.407 3.604 5.990 3.532 5.574 3.461 5.074 3.376
22 7.472 3.438 7.041 3.386 6.611 3.335 6.181 3.284 5.750 3.232 5.234 3.170
23 7.703 3.130 7.259 3.098 6.815 3.066 6.371 3.035 5.927 3.003 5.394 2.965
24 7.935 2.822 7.477 2.810 7.020 2.798 6.562 2.786 6.104 2.774 5.554 2.759
20 7.008 4.540 6.605 4.449 6.202 4.358 5.800 4.267 5.397 4.176 4.914 4.067
21 7.240 4.232 6.823 4.160 6.407 4.089 5.990 4.018 5.574 3.947 5.074 3.861
22 7.472 3.923 7.041 3.872 6.611 3.820 6.181 3.769 5.750 3.717 5.234 3.656
23 7.703 3.615 7.259 3.583 6.815 3.552 6.371 3.520 5.927 3.488 5.394 3.450
24 7.935 3.307 7.477 3.295 7.020 3.283 6.562 3.271 6.104 3.259 5.554 3.245
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 7.548 5.116 7.125 4.731 6.702 4.345 6.278 3.960 5.855 3.574 5.347 3.112
16 7.724 4.701 7.311 4.360 6.897 4.019 6.484 3.678 6.070 3.336 5.573 2.927
16 7.724 5.768 7.311 5.427 6.897 5.086 6.484 4.745 6.070 4.404 5.573 3.994
17 7.900 5.353 7.497 5.056 7.093 4.759 6.689 4.462 6.285 4.166 5.800 3.810
18 8.077 4.937 7.682 4.685 7.288 4.433 6.894 4.180 6.499 3.928 6.026 3.625
19 8.253 4.522 7.868 4.314 7.483 4.106 7.099 3.898 6.714 3.690 6.252 3.441
20 8.428 4.106 8.044 3.938 7.660 3.769 7.275 3.601 6.891 3.433 6.431 3.231
18 8.077 6.004 7.682 5.752 7.288 5.500 6.894 5.247 6.499 4.995 6.026 4.692
19 8.253 5.589 7.868 5.381 7.483 5.173 7.099 4.965 6.714 4.757 6.252 4.508
20 8.428 5.173 8.044 5.005 7.660 4.837 7.275 4.668 6.891 4.500 6.431 4.298
21 8.602 4.757 8.212 4.625 7.823 4.493 7.434 4.362 7.044 4.230 6.577 4.072
22 8.776 4.340 8.381 4.245 7.986 4.150 7.592 4.055 7.197 3.960 6.723 3.845
23 8.950 3.924 8.550 3.865 8.150 3.807 7.750 3.748 7.350 3.689 6.869 3.619
24 9.125 3.508 8.719 3.486 8.313 3.463 7.908 3.441 7.502 3.419 7.015 3.393
20 8.428 5.707 8.044 5.538 7.660 5.370 7.275 5.202 6.891 5.034 6.431 4.832
21 8.602 5.290 8.212 5.159 7.823 5.027 7.434 4.895 7.044 4.763 6.577 4.605
22 8.776 4.874 8.381 4.779 7.986 4.684 7.592 4.588 7.197 4.493 6.723 4.379
23 8.950 4.458 8.550 4.399 8.150 4.340 7.750 4.282 7.350 4.223 6.869 4.153
24 9.125 4.041 8.719 4.019 8.313 3.997 7.908 3.975 7.502 3.953 7.015 3.926
Outdoor DB°C · Outdoor DB°C

MODEL : ACM 28E / ALC 28C
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 8.627 5.602 8.148 5.215 7.669 4.828 7.190 4.441 6.711 4.054 6.136 3.589
16 9.034 5.190 8.509 4.841 7.985 4.492 7.460 4.142 6.935 3.793 6.306 3.374
16 9.034 6.458 8.509 6.109 7.985 5.760 7.460 5.410 6.935 5.061 6.306 4.642
17 9.442 6.047 8.871 5.735 8.301 5.423 7.730 5.112 7.160 4.800 6.475 4.426
18 9.849 5.635 9.233 5.361 8.617 5.087 8.001 4.813 7.385 4.540 6.645 4.211
19 10.256 5.223 9.595 4.987 8.933 4.751 8.271 4.515 7.609 4.279 6.815 3.996
20 10.665 4.811 9.971 4.607 9.276 4.403 8.581 4.200 7.887 3.996 7.053 3.751
18 9.849 6.903 9.233 6.629 8.617 6.355 8.001 6.081 7.385 5.807 6.645 5.479
19 10.256 6.491 9.595 6.255 8.933 6.019 8.271 5.783 7.609 5.547 6.815 5.264
20 10.665 6.078 9.971 5.875 9.276 5.671 8.581 5.467 7.887 5.264 7.053 5.019
21 11.075 5.666 10.356 5.491 9.637 5.315 8.918 5.140 8.199 4.965 7.336 4.755
22 11.485 5.253 10.742 5.106 9.999 4.960 9.255 4.813 8.512 4.667 7.620 4.491
23 11.895 4.840 11.128 4.722 10.360 4.604 9.592 4.486 8.824 4.368 7.903 4.226
24 12.305 4.427 11.513 4.338 10.721 4.248 9.929 4.159 9.137 4.069 8.186 3.962
20 10.665 6.712 9.971 6.509 9.276 6.305 8.581 6.101 7.887 5.897 7.053 5.653
21 11.075 6.300 10.356 6.124 9.637 5.949 8.918 5.774 8.199 5.599 7.336 5.389
22 11.485 5.887 10.742 5.740 9.999 5.594 9.255 5.447 8.512 5.300 7.620 5.124
23 11.895 5.474 11.128 5.356 10.360 5.238 9.592 5.120 8.824 5.002 7.903 4.860
24 12.305 5.061 11.513 4.972 10.721 4.882 9.929 4.793 9.137 4.703 8.186 4.596
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 8.897 5.879 8.367 5.441 7.837 5.003 7.307 4.564 6.778 4.126 6.142 3.600
16 9.245 5.407 8.681 5.018 8.117 4.629 7.553 4.240 6.989 3.851 6.312 3.385
16 9.245 6.675 8.681 6.286 8.117 5.897 7.553 5.508 6.989 5.119 6.312 4.653
17 9.594 6.203 8.995 5.863 8.397 5.524 7.798 5.184 7.200 4.844 6.482 4.437
18 9.942 5.731 9.309 5.441 8.677 5.150 8.044 4.860 7.411 4.570 6.652 4.221
19 10.290 5.259 9.623 5.018 8.956 4.777 8.289 4.536 7.622 4.295 6.822 4.006
20 10.640 4.786 9.952 4.589 9.263 4.392 8.575 4.195 7.886 3.997 7.060 3.761
18 9.942 6.999 9.309 6.708 8.677 6.418 8.044 6.128 7.411 5.837 6.652 5.489
19 10.290 6.527 9.623 6.286 8.956 6.045 8.289 5.804 7.622 5.563 6.822 5.273
20 10.640 6.054 9.952 5.857 9.263 5.660 8.575 5.462 7.886 5.265 7.060 5.028
21 10.992 5.581 10.290 5.424 9.588 5.267 8.887 5.109 8.185 4.952 7.344 4.764
22 11.343 5.108 10.628 4.991 9.914 4.874 9.199 4.757 8.485 4.639 7.627 4.499
23 11.694 4.635 10.966 4.558 10.239 4.481 9.511 4.404 8.784 4.326 7.911 4.234
24 12.045 4.162 11.304 4.125 10.564 4.088 9.823 4.051 9.083 4.014 8.195 3.969
20 10.640 6.688 9.952 6.491 9.263 6.293 8.575 6.096 7.886 5.899 7.060 5.662
21 10.992 6.215 10.290 6.058 9.588 5.901 8.887 5.743 8.185 5.586 7.344 5.397
22 11.343 5.742 10.628 5.625 9.914 5.508 9.199 5.390 8.485 5.273 7.627 5.133
23 11.694 5.269 10.966 5.192 10.239 5.115 9.511 5.037 8.784 4.960 7.911 4.868
24 12.045 4.796 11.304 4.759 10.564 4.722 9.823 4.685 9.083 4.648 8.195 4.603
Outdoor DB°C · Outdoor DB°C

MODEL : ACM 15ER / ALC 15CR COOLING MODE
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 4.198 2.455 3.897 2.140 3.596 1.825 3.295 1.510 2.995 1.195 2.634 0.816
16 4.255 2.390 3.958 2.065 3.660 1.741 3.363 1.417 3.066 1.093 2.709 0.704
16 4.255 3.353 3.958 3.029 3.660 2.705 3.363 2.381 3.066 2.056 2.709 1.667
17 4.313 3.288 4.019 2.955 3.725 2.621 3.431 2.288 3.137 1.954 2.784 1.554
18 4.370 3.224 4.080 2.881 3.789 2.538 3.498 2.195 3.208 1.853 2.859 1.441
19 4.428 3.159 4.140 2.807 3.853 2.455 3.566 2.103 3.279 1.751 2.934 1.328
20 4.486 3.095 4.207 2.744 3.928 2.393 3.649 2.042 3.370 1.691 3.036 1.270
18 4.370 4.187 4.080 3.844 3.789 3.502 3.498 3.159 3.208 2.816 2.859 2.405
19 4.428 4.122 4.140 3.770 3.853 3.418 3.566 3.066 3.279 2.714 2.934 2.292
20 4.486 4.059 4.207 3.708 3.928 3.357 3.649 3.006 3.370 2.655 3.036 2.234
21 4.544 3.996 4.277 3.653 4.010 3.310 3.742 2.967 3.475 2.624 3.154 2.213
22 4.603 3.933 4.347 3.598 4.091 3.263 3.836 2.928 3.580 2.593 3.273 2.192
23 4.661 3.870 4.417 3.543 4.173 3.216 3.929 2.890 3.685 2.563 3.392 2.170
24 4.720 3.807 4.487 3.489 4.255 3.170 4.022 2.851 3.790 2.532 3.511 2.149
20 4.540 4.540 4.207 4.190 3.928 3.839 3.649 3.488 3.370 3.137 3.036 2.716
21 4.544 4.478 4.277 4.135 4.010 3.792 3.742 3.449 3.475 3.106 3.154 2.695
22 4.603 4.415 4.347 4.080 4.091 3.745 3.836 3.410 3.580 3.075 3.273 2.673
23 4.661 4.352 4.417 4.025 4.173 3.698 3.929 3.371 3.685 3.044 3.392 2.652
24 4.720 4.289 4.487 3.970 4.255 3.651 4.022 3.333 3.790 3.014 3.511 2.631
-9 -6 -5 6 12 15 18
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 1.760 1.760 2.115 2.115 2.233 2.233 3.532 3.532 4.241 4.241 4.596 4.596 4.950 4.950
17 1.738 1.738 2.079 2.079 2.192 2.192 3.471 3.471 4.127 4.127 4.468 4.468 4.809 4.809
19 1.716 1.716 2.043 2.043 2.152 2.152 3.410 3.410 4.012 4.012 4.340 4.340 4.669 4.669
21 1.693 1.693 2.007 2.007 2.111 2.111 3.350 3.350 3.897 3.897 4.213 4.213 4.528 4.528
23 1.669 1.669 1.970 1.970 2.071 2.071 3.232 3.232 3.783 3.783 4.085 4.085 4.387 4.387
25 1.645 1.645 1.934 1.934 2.030 2.030 3.115 3.115 3.668 3.668 3.957 3.957 4.246 4.246
27 1.621 1.621 1.897 1.897 1.989 1.989 2.997 2.997 3.554 3.554 3.830 3.830 4.106 4.106
Outdoor DB°C · Outdoor WB°C

MODEL : ACM 20ER / ALC 18CR COOLING MODE
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 5.743 3.699 5.397 3.404 5.050 3.110 4.703 2.816 4.356 2.522 3.940 2.168
16 5.969 3.449 5.599 3.179 5.228 2.910 4.858 2.640 4.488 2.371 4.044 2.047
16 5.969 4.359 5.599 4.090 5.228 3.820 4.858 3.551 4.488 3.281 4.044 2.958
17 6.194 4.109 5.800 3.864 5.407 3.620 5.014 3.375 4.621 3.130 4.149 2.837
18 6.419 3.859 6.002 3.639 5.586 3.419 5.169 3.199 4.753 2.979 4.253 2.715
19 6.644 3.609 6.204 3.414 5.765 3.219 5.325 3.023 4.885 2.828 4.358 2.594
20 6.870 3.358 6.417 3.183 5.963 3.008 5.510 2.833 5.056 2.658 4.512 2.448
18 6.419 4.770 6.002 4.550 5.586 4.330 5.169 4.110 4.753 3.890 4.253 3.626
19 6.644 4.520 6.204 4.324 5.765 4.129 5.325 3.934 4.885 3.739 4.358 3.505
20 6.870 4.269 6.417 4.094 5.963 3.919 5.510 3.744 5.056 3.569 4.512 3.359
21 7.097 4.018 6.636 3.860 6.175 3.702 5.714 3.544 5.253 3.386 4.700 3.196
22 7.324 3.767 6.855 3.626 6.387 3.485 5.918 3.344 5.450 3.202 4.888 3.033
23 7.551 3.516 7.075 3.392 6.599 3.268 6.123 3.143 5.647 3.019 5.075 2.871
24 7.778 3.265 7.294 3.158 6.811 3.050 6.327 2.943 5.844 2.836 5.263 2.708
20 6.870 4.724 6.417 4.549 5.963 4.374 5.510 4.199 5.056 4.024 4.512 3.814
21 7.097 4.473 6.636 4.315 6.175 4.157 5.714 3.999 5.253 3.841 4.700 3.651
22 7.324 4.222 6.855 4.081 6.387 3.940 5.918 3.799 5.450 3.658 4.888 3.489
23 7.551 3.971 7.075 3.847 6.599 3.723 6.123 3.599 5.647 3.475 5.075 3.326
24 7.778 3.720 7.294 3.613 6.811 3.506 6.327 3.399 5.844 3.292 5.263 3.163
-9 -6 -5 6 12 15 18
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 2.597 2.597 3.151 3.151 3.335 3.335 5.366 5.366 6.474 6.474 7.028 7.028 7.582 7.582
17 2.556 2.556 3.094 3.094 3.274 3.274 5.299 5.299 6.299 6.299 6.833 6.833 7.367 7.367
19 2.516 2.516 3.038 3.038 3.213 3.213 5.231 5.231 6.124 6.124 6.637 6.637 7.151 7.151
21 2.475 2.475 2.982 2.982 3.151 3.151 5.164 5.164 5.948 5.948 6.442 6.442 6.935 6.935
23 2.447 2.447 2.929 2.929 3.090 3.090 4.958 4.958 5.773 5.773 6.246 6.246 6.720 6.720
25 2.419 2.419 2.876 2.876 3.028 3.028 4.751 4.751 5.597 5.597 6.051 6.051 6.504 6.504
27 2.390 2.390 2.823 2.823 2.967 2.967 4.545 4.545 5.422 5.422 5.855 5.855 6.289 6.289
Outdoor DB°C · Outdoor WB°C

MODEL : ACM 20ER / ALC 20CR COOLING MODE
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 5.850 3.645 5.531 3.384 5.213 3.123 4.894 2.862 4.575 2.602 4.193 2.288
16 6.081 3.339 5.746 3.114 5.410 2.889 5.074 2.664 4.738 2.439 4.335 2.169
16 6.081 4.310 5.746 4.085 5.410 3.860 5.074 3.635 4.738 3.410 4.335 3.140
17 6.313 4.004 5.960 3.814 5.607 3.625 5.254 3.436 4.900 3.247 4.477 3.020
18 6.544 3.697 6.174 3.544 5.804 3.391 5.433 3.238 5.063 3.085 4.619 2.901
19 6.776 3.391 6.388 3.274 6.001 3.157 5.613 3.039 5.226 2.922 4.761 2.781
20 7.008 3.084 6.605 2.993 6.202 2.902 5.800 2.811 5.397 2.720 4.914 2.610
18 6.544 4.668 6.174 4.515 5.804 4.362 5.433 4.209 5.063 4.055 4.619 3.872
19 6.776 4.362 6.388 4.245 6.001 4.127 5.613 4.010 5.226 3.893 4.761 3.752
20 7.008 4.054 6.605 3.963 6.202 3.872 5.800 3.781 5.397 3.690 4.914 3.581
21 7.240 3.746 6.823 3.675 6.407 3.604 5.990 3.532 5.574 3.461 5.074 3.376
22 7.472 3.438 7.041 3.386 6.611 3.335 6.181 3.284 5.750 3.232 5.234 3.170
23 7.703 3.130 7.259 3.098 6.815 3.066 6.371 3.035 5.927 3.003 5.394 2.965
24 7.935 2.822 7.477 2.810 7.020 2.798 6.562 2.786 6.104 2.774 5.554 2.759
20 7.008 4.540 6.605 4.449 6.202 4.358 5.800 4.267 5.397 4.176 4.914 4.067
21 7.240 4.232 6.823 4.160 6.407 4.089 5.990 4.018 5.574 3.947 5.074 3.861
22 7.472 3.923 7.041 3.872 6.611 3.820 6.181 3.769 5.750 3.717 5.234 3.656
23 7.703 3.615 7.259 3.583 6.815 3.552 6.371 3.520 5.927 3.488 5.394 3.450
24 7.935 3.307 7.477 3.295 7.020 3.283 6.562 3.271 6.104 3.259 5.554 3.245
-9 -6 -5 6 12 15 18
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 2.506 2.506 3.124 3.124 3.330 3.330 5.597 5.597 6.834 6.834 7.452 7.452 8.071 8.071
17 2.446 2.446 3.062 3.062 3.267 3.267 5.499 5.499 6.648 6.648 7.245 7.245 7.841 7.841
19 2.386 2.386 2.999 2.999 3.204 3.204 5.401 5.401 6.462 6.462 7.037 7.037 7.612 7.612
21 2.326 2.326 2.937 2.937 3.140 3.140 5.303 5.303 6.276 6.276 6.829 6.829 7.382 7.382
23 2.319 2.319 2.887 2.887 3.077 3.077 5.113 5.113 6.089 6.089 6.621 6.621 7.153 7.153
25 2.311 2.311 2.838 2.838 3.014 3.014 4.924 4.924 5.903 5.903 6.413 6.413 6.923 6.923
27 2.304 2.304 2.789 2.789 2.951 2.951 4.734 4.734 5.717 5.717 6.205 6.205 6.694 6.694
Outdoor DB°C · Outdoor WB°C

MODEL : ACM 25ER / ALC 25CR COOLING MODE
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 7.548 5.116 7.125 4.731 6.702 4.345 6.278 3.960 5.855 3.574 5.347 3.112
16 7.724 4.701 7.311 4.360 6.897 4.019 6.484 3.678 6.070 3.336 5.573 2.927
16 7.724 5.768 7.311 5.427 6.897 5.086 6.484 4.745 6.070 4.404 5.573 3.994
17 7.900 5.353 7.497 5.056 7.093 4.759 6.689 4.462 6.285 4.166 5.800 3.810
18 8.077 4.937 7.682 4.685 7.288 4.433 6.894 4.180 6.499 3.928 6.026 3.625
19 8.253 4.522 7.868 4.314 7.483 4.106 7.099 3.898 6.714 3.690 6.252 3.441
20 8.428 4.106 8.044 3.938 7.660 3.769 7.275 3.601 6.891 3.433 6.431 3.231
18 8.077 6.004 7.682 5.752 7.288 5.500 6.894 5.247 6.499 4.995 6.026 4.692
19 8.253 5.589 7.868 5.381 7.483 5.173 7.099 4.965 6.714 4.757 6.252 4.508
20 8.428 5.173 8.044 5.005 7.660 4.837 7.275 4.668 6.891 4.500 6.431 4.298
21 8.602 4.757 8.212 4.625 7.823 4.493 7.434 4.362 7.044 4.230 6.577 4.072
22 8.776 4.340 8.381 4.245 7.986 4.150 7.592 4.055 7.197 3.960 6.723 3.845
23 8.950 3.924 8.550 3.865 8.150 3.807 7.750 3.748 7.350 3.689 6.869 3.619
24 9.125 3.508 8.719 3.486 8.313 3.463 7.908 3.441 7.502 3.419 7.015 3.393
20 8.428 5.707 8.044 5.538 7.660 5.370 7.275 5.202 6.891 5.034 6.431 4.832
21 8.602 5.290 8.212 5.159 7.823 5.027 7.434 4.895 7.044 4.763 6.577 4.605
22 8.776 4.874 8.381 4.779 7.986 4.684 7.592 4.588 7.197 4.493 6.723 4.379
23 8.950 4.458 8.550 4.399 8.150 4.340 7.750 4.282 7.350 4.223 6.869 4.153
24 9.125 4.041 8.719 4.019 8.313 3.997 7.908 3.975 7.502 3.953 7.015 3.926
-9 -6 -5 6 12 15 18
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 3.228 3.228 4.000 4.000 4.257 4.257 7.088 7.088 8.633 8.633 9.405 9.405 10.177 10.177
17 3.157 3.157 3.922 3.922 4.177 4.177 7.052 7.052 8.398 8.398 9.143 9.143 9.887 9.887
19 3.086 3.086 3.844 3.844 4.097 4.097 7.015 7.015 8.163 8.163 8.880 8.880 9.598 9.598
21 3.015 3.015 3.766 3.766 4.016 4.016 6.978 6.978 7.928 7.928 8.618 8.618 9.309 9.309
23 2.999 2.999 3.702 3.702 3.936 3.936 6.647 6.647 7.693 7.693 8.356 8.356 9.019 9.019
25 2.984 2.984 3.638 3.638 3.856 3.856 6.315 6.315 7.458 7.458 8.094 8.094 8.730 8.730
27 2.968 2.968 3.574 3.574 3.775 3.775 5.984 5.984 7.223 7.223 7.832 7.832 8.440 8.440
Outdoor DB°C · Outdoor WB°C

MODEL : ACM 28ER / ALC 28CR COOLING MODE
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 8.627 5.602 8.148 5.215 7.669 4.828 7.190 4.441 6.711 4.054 6.136 3.589
16 9.034 5.190 8.509 4.841 7.985 4.492 7.460 4.142 6.935 3.793 6.306 3.374
16 9.034 6.458 8.509 6.109 7.985 5.760 7.460 5.410 6.935 5.061 6.306 4.642
17 9.442 6.047 8.871 5.735 8.301 5.423 7.730 5.112 7.160 4.800 6.475 4.426
18 9.849 5.635 9.233 5.361 8.617 5.087 8.001 4.813 7.385 4.540 6.645 4.211
19 10.256 5.223 9.595 4.987 8.933 4.751 8.271 4.515 7.609 4.279 6.815 3.996
20 10.665 4.811 9.971 4.607 9.276 4.403 8.581 4.200 7.887 3.996 7.053 3.751
18 9.849 6.903 9.233 6.629 8.617 6.355 8.001 6.081 7.385 5.807 6.645 5.479
19 10.256 6.491 9.595 6.255 8.933 6.019 8.271 5.783 7.609 5.547 6.815 5.264
20 10.665 6.078 9.971 5.875 9.276 5.671 8.581 5.467 7.887 5.264 7.053 5.019
21 11.075 5.666 10.356 5.491 9.637 5.315 8.918 5.140 8.199 4.965 7.336 4.755
22 11.485 5.253 10.742 5.106 9.999 4.960 9.255 4.813 8.512 4.667 7.620 4.491
23 11.895 4.840 11.128 4.722 10.360 4.604 9.592 4.486 8.824 4.368 7.903 4.226
24 12.305 4.427 11.513 4.338 10.721 4.248 9.929 4.159 9.137 4.069 8.186 3.962
20 10.665 6.712 9.971 6.509 9.276 6.305 8.581 6.101 7.887 5.897 7.053 5.653
21 11.075 6.300 10.356 6.124 9.637 5.949 8.918 5.774 8.199 5.599 7.336 5.389
22 11.485 5.887 10.742 5.740 9.999 5.594 9.255 5.447 8.512 5.300 7.620 5.124
23 11.895 5.474 11.128 5.356 10.360 5.238 9.592 5.120 8.824 5.002 7.903 4.860
24 12.305 5.061 11.513 4.972 10.721 4.882 9.929 4.793 9.137 4.703 8.186 4.596
-9 -6 -5 6 12 15 18
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 3.707 3.707 4.621 4.621 4.926 4.926 8.276 8.276 10.103 10.103 11.017 11.017 11.931 11.931
17 3.619 3.619 4.529 4.529 4.832 4.832 8.122 8.122 9.828 9.828 10.710 10.710 11.591 11.591
19 3.531 3.531 4.437 4.437 4.739 4.739 7.969 7.969 9.553 9.553 10.402 10.402 11.252 11.252
21 3.443 3.443 4.344 4.344 4.645 4.645 7.816 7.816 9.278 9.278 10.095 10.095 10.913 10.913
23 3.431 3.431 4.271 4.271 4.552 4.552 7.544 7.544 9.003 9.003 9.788 9.788 10.573 10.573
25 3.420 3.420 4.198 4.198 4.458 4.458 7.272 7.272 8.727 8.727 9.481 9.481 10.234 10.234
27 3.409 3.409 4.125 4.125 4.364 4.364 7.000 7.000 8.452 8.452 9.173 9.173 9.895 9.895
Outdoor DB°C · Outdoor WB°C

MODEL : ACM 28ER / ALC 30CR COOLING MODE
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 8.897 5.879 8.367 5.441 7.837 5.003 7.307 4.564 6.778 4.126 6.142 3.600
16 9.245 5.407 8.681 5.018 8.117 4.629 7.553 4.240 6.989 3.851 6.312 3.385
16 9.245 6.675 8.681 6.286 8.117 5.897 7.553 5.508 6.989 5.119 6.312 4.653
17 9.594 6.203 8.995 5.863 8.397 5.524 7.798 5.184 7.200 4.844 6.482 4.437
18 9.942 5.731 9.309 5.441 8.677 5.150 8.044 4.860 7.411 4.570 6.652 4.221
19 10.290 5.259 9.623 5.018 8.956 4.777 8.289 4.536 7.622 4.295 6.822 4.006
20 10.640 4.786 9.952 4.589 9.263 4.392 8.575 4.195 7.886 3.997 7.060 3.761
18 9.942 6.999 9.309 6.708 8.677 6.418 8.044 6.128 7.411 5.837 6.652 5.489
19 10.290 6.527 9.623 6.286 8.956 6.045 8.289 5.804 7.622 5.563 6.822 5.273
20 10.640 6.054 9.952 5.857 9.263 5.660 8.575 5.462 7.886 5.265 7.060 5.028
21 10.992 5.581 10.290 5.424 9.588 5.267 8.887 5.109 8.185 4.952 7.344 4.764
22 11.343 5.108 10.628 4.991 9.914 4.874 9.199 4.757 8.485 4.639 7.627 4.499
23 11.694 4.635 10.966 4.558 10.239 4.481 9.511 4.404 8.784 4.326 7.911 4.234
24 12.045 4.162 11.304 4.125 10.564 4.088 9.823 4.051 9.083 4.014 8.195 3.969
20 10.640 6.688 9.952 6.491 9.263 6.293 8.575 6.096 7.886 5.899 7.060 5.662
21 10.992 6.215 10.290 6.058 9.588 5.901 8.887 5.743 8.185 5.586 7.344 5.397
22 11.343 5.742 10.628 5.625 9.914 5.508 9.199 5.390 8.485 5.273 7.627 5.133
23 11.694 5.269 10.966 5.192 10.239 5.115 9.511 5.037 8.784 4.960 7.911 4.868
24 12.045 4.796 11.304 4.759 10.564 4.722 9.823 4.685 9.083 4.648 8.195 4.603
-9 -6 -5 6 12 15 18
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 3.707 3.707 4.621 4.621 4.926 4.926 8.276 8.276 10.103 10.103 11.017 11.017 11.931 11.931
17 3.619 3.619 4.529 4.529 4.832 4.832 8.122 8.122 9.828 9.828 10.710 10.710 11.591 11.591
19 3.531 3.531 4.437 4.437 4.739 4.739 7.969 7.969 9.553 9.553 10.402 10.402 11.252 11.252
21 3.443 3.443 4.344 4.344 4.645 4.645 7.816 7.816 9.278 9.278 10.095 10.095 10.913 10.913
23 3.431 3.431 4.271 4.271 4.552 4.552 7.544 7.544 9.003 9.003 9.788 9.788 10.573 10.573
25 3.420 3.420 4.198 4.198 4.458 4.458 7.272 7.272 8.727 8.727 9.481 9.481 10.234 10.234
27 3.409 3.409 4.125 4.125 4.364 4.364 7.000 7.000 8.452 8.452 9.173 9.173 9.895 9.895
Outdoor DB°C · Outdoor WB°C

MODEL : A5CM 15E / A5LC 15C
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 4.362 2.573 3.980 2.190 3.593 1.802 3.206 1.414 2.819 1.027 2.354 0.562
16 4.440 2.359 4.074 2.005 3.706 1.648 3.338 1.292 2.970 0.936 2.528 0.508
16 4.440 3.385 4.074 3.031 3.706 2.675 3.338 2.318 2.970 1.962 2.528 1.534
17 4.517 3.171 4.168 2.846 3.819 2.521 3.470 2.196 3.121 1.871 2.702 1.481
18 4.597 2.960 4.266 2.665 3.935 2.370 3.604 2.075 3.273 1.781 2.876 1.427
19 4.679 2.753 4.380 2.515 4.082 2.276 3.783 2.038 3.450 1.736 3.050 1.373
20 4.752 2.529 4.437 2.257 4.122 1.986 3.807 1.714 3.492 1.443 3.114 1.117
18 4.597 3.986 4.266 3.691 3.935 3.396 3.604 3.102 3.273 2.807 2.876 2.453
19 4.679 3.779 4.380 3.541 4.082 3.302 3.783 3.064 3.450 2.762 3.050 2.400
20 4.752 3.555 4.437 3.283 4.122 3.012 3.807 2.740 3.492 2.469 3.114 2.143
21 4.827 3.336 4.510 3.057 4.193 2.778 3.876 2.500 3.559 2.221 3.178 1.887
22 4.903 3.116 4.583 2.831 4.264 2.545 3.945 2.259 3.625 1.974 3.242 1.631
23 4.978 2.897 4.657 2.604 4.335 2.312 4.014 2.019 3.692 1.726 3.306 1.374
24 5.054 2.678 4.730 2.378 4.406 2.078 4.082 1.778 3.759 1.478 3.370 1.118
20 4.752 4.068 4.437 3.796 4.122 3.525 3.807 3.254 3.492 2.982 3.114 2.656
21 4.827 3.849 4.510 3.570 4.193 3.292 3.876 3.013 3.559 2.734 3.178 2.400
22 4.903 3.630 4.583 3.344 4.264 3.058 3.945 2.772 3.625 2.487 3.242 2.144
23 4.978 3.410 4.657 3.117 4.335 2.825 4.014 2.532 3.692 2.239 3.306 1.887
24 5.054 3.191 4.730 2.891 4.406 2.591 4.082 2.291 3.759 1.991 3.370 1.631
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 5.715 3.788 5.176 3.247 4.622 2.692 4.068 2.137 3.514 1.581 2.849 0.915
16 5.842 3.492 5.34 2.99 4.83 2.481 4.32 1.971 3.811 1.462 3.199 0.85
16 5.842 4.601 5.34 4.099 4.83 3.59 4.32 3.08 3.811 2.57 3.199 1.959
17 5.968 4.306 5.503 3.842 5.038 3.378 4.573 2.914 4.107 2.451 3.549 1.894
18 6.102 4.017 5.678 3.596 5.255 3.176 4.831 2.755 4.408 2.334 3.899 1.829
19 6.238 3.737 5.868 3.403 5.498 3.068 5.128 2.733 4.729 2.293 4.249 1.764
20 6.36 3.431 5.971 3.051 5.582 2.671 5.194 2.29 4.805 1.91 4.339 1.454
18 6.102 5.126 5.678 4.705 5.255 4.285 4.831 3.864 4.408 3.443 3.899 2.938
19 6.238 4.846 5.868 4.512 5.498 4.177 5.128 3.842 4.729 3.402 4.249 2.873
20 6.36 4.54 5.971 4.16 5.582 3.78 5.194 3.399 4.805 3.019 4.339 2.563
21 6.484 4.243 6.088 3.86 5.693 3.477 5.298 3.094 4.902 2.712 4.428 2.252
22 6.608 3.945 6.206 3.56 5.804 3.175 5.402 2.789 4.999 2.404 4.517 1.942
23 6.732 3.648 6.323 3.26 5.914 2.872 5.505 2.484 5.097 2.097 4.606 1.631
24 6.856 3.35 6.44 2.96 6.025 2.57 5.609 2.18 5.194 1.789 4.695 1.321
20 6.36 5.095 5.971 4.714 5.582 4.334 5.194 3.954 4.805 3.574 4.339 3.117
21 6.484 4.797 6.088 4.414 5.693 4.032 5.298 3.649 4.902 3.266 4.428 2.807
22 6.608 4.5 6.206 4.115 5.804 3.729 5.402 3.344 4.999 2.959 4.517 2.496
23 6.732 4.202 6.323 3.815 5.914 3.427 5.505 3.039 5.097 2.651 4.606 2.186
24 6.856 3.905 6.44 3.515 6.025 3.124 5.609 2.734 5.194 2.344 4.695 1.875
Outdoor DB°C · Outdoor DB°C

MODEL : A5CM 20E / A5LC 20C (3 PHASE)
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 5.670 3.743 5.205 3.276 4.741 2.812 4.278 2.347 3.815 1.883 3.258 1.325
16 5.833 3.471 5.392 3.044 4.951 2.617 4.511 2.190 4.071 1.763 3.543 1.251
16 5.833 4.580 5.392 4.153 4.951 3.726 4.511 3.299 4.071 2.872 3.543 2.360
17 5.995 4.309 5.578 3.920 5.161 3.531 4.744 3.142 4.327 2.753 3.827 2.286
18 6.157 4.037 5.764 3.686 5.370 3.335 4.977 2.984 4.584 2.633 4.111 2.212
19 6.324 3.766 5.984 3.463 5.644 3.159 5.304 2.855 4.891 2.529 4.396 2.137
20 6.473 3.482 6.091 3.155 5.710 2.828 5.328 2.501 4.946 2.174 4.488 1.782
18 6.157 5.146 5.764 4.795 5.370 4.444 4.977 4.093 4.584 3.742 4.111 3.321
19 6.324 4.875 5.984 4.572 5.644 4.268 5.304 3.964 4.891 3.638 4.396 3.246
20 6.473 4.591 6.091 4.264 5.710 3.937 5.328 3.610 4.946 3.283 4.488 2.891
21 6.627 4.308 6.234 3.967 5.840 3.627 5.446 3.286 5.053 2.945 4.580 2.536
22 6.782 4.025 6.376 3.671 5.971 3.316 5.565 2.961 5.159 2.607 4.673 2.181
23 6.936 3.743 6.519 3.374 6.101 3.005 5.684 2.637 5.266 2.268 4.765 1.826
24 7.091 3.460 6.661 3.077 6.232 2.695 5.802 2.312 5.373 1.930 4.857 1.471
20 6.473 5.145 6.091 4.818 5.710 4.492 5.328 4.165 4.946 3.838 4.488 3.446
21 6.627 4.863 6.234 4.522 5.840 4.181 5.446 3.840 5.053 3.499 4.580 3.091
22 6.782 4.580 6.376 4.225 5.971 3.870 5.565 3.516 5.159 3.161 4.673 2.735
23 6.936 4.297 6.519 3.929 6.101 3.560 5.684 3.191 5.266 2.823 4.765 2.380
24 7.091 4.014 6.661 3.632 6.232 3.249 5.802 2.867 5.373 2.484 4.857 2.025
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 5.924 4.060 5.602 3.715 5.279 3.405 4.956 3.096 4.633 2.787 4.246 2.416
16 6.138 3.823 5.810 3.519 5.481 3.233 5.153 2.947 4.824 2.662 4.430 2.319
16 6.138 4.870 5.810 4.566 5.481 4.281 5.153 3.995 4.824 3.710 4.430 3.367
17 6.352 4.633 6.018 4.371 5.684 4.109 5.349 3.847 5.015 3.585 4.614 3.270
18 6.567 4.378 6.227 4.146 5.886 3.915 5.546 3.683 5.206 3.452 4.798 3.174
19 6.789 4.112 6.479 3.854 6.170 3.595 5.860 3.337 5.461 3.219 4.981 3.077
20 6.993 3.855 6.626 3.616 6.260 3.378 5.893 3.140 5.526 2.901 5.086 2.615
18 6.567 5.426 6.227 5.194 5.886 4.963 5.546 4.731 5.206 4.499 4.798 4.221
19 6.789 5.160 6.479 4.901 6.170 4.643 5.860 4.385 5.461 4.267 4.981 4.125
20 6.993 4.903 6.626 4.664 6.260 4.426 5.893 4.187 5.526 3.949 5.086 3.663
21 7.205 4.634 6.817 4.359 6.430 4.083 6.043 3.807 5.655 3.532 5.191 3.201
22 7.416 4.366 7.008 4.053 6.600 3.740 6.193 3.427 5.785 3.114 5.295 2.739
23 7.628 4.098 7.199 3.748 6.771 3.397 6.342 3.047 5.914 2.697 5.400 2.277
24 7.839 3.829 7.390 3.442 6.941 3.055 6.492 2.667 6.043 2.280 5.504 1.815
20 6.993 5.427 6.626 5.188 6.260 4.950 5.893 4.711 5.526 4.473 5.086 4.187
21 7.205 5.158 6.817 4.883 6.430 4.607 6.043 4.331 5.655 4.056 5.191 3.725
22 7.416 4.890 7.008 4.577 6.600 4.264 6.193 3.951 5.785 3.638 5.295 3.263
23 7.628 4.622 7.199 4.271 6.771 3.921 6.342 3.571 5.914 3.221 5.400 2.801
24 7.839 4.353 7.390 3.966 6.941 3.578 6.492 3.191 6.043 2.804 5.504 2.339
Outdoor DB°C · Outdoor DB°C

MODEL : A5CM 25E / A5LC 25C (3 PHASE)
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 6.763 4.405 6.436 4.061 6.057 3.765 5.677 3.469 5.298 3.173 4.842 2.818
16 6.992 4.182 6.649 3.879 6.279 3.600 5.910 3.321 5.540 3.042 5.097 2.708
16 6.992 5.341 6.649 5.038 6.279 4.759 5.910 4.480 5.540 4.201 5.097 3.867
17 7.221 5.117 6.861 4.855 6.502 4.594 6.142 4.332 5.783 4.071 5.351 3.757
18 7.474 4.871 7.115 4.635 6.755 4.400 6.396 4.164 6.037 3.929 5.606 3.646
19 7.730 4.623 7.386 4.406 7.042 4.188 6.699 3.971 6.318 3.773 5.860 3.536
20 7.975 4.363 7.592 4.103 7.209 3.842 6.826 3.582 6.443 3.322 5.984 3.009
18 7.474 6.030 7.115 5.794 6.755 5.559 6.396 5.323 6.037 5.088 5.606 4.805
19 7.730 5.782 7.386 5.565 7.042 5.347 6.699 5.130 6.318 4.932 5.860 4.695
20 7.975 5.522 7.592 5.262 7.209 5.001 6.826 4.741 6.443 4.481 5.984 4.168
21 8.223 5.260 7.816 4.949 7.409 4.638 7.002 4.326 6.595 4.015 6.107 3.641
22 8.471 4.999 8.040 4.636 7.609 4.274 7.178 3.912 6.747 3.549 6.230 3.115
23 8.719 4.737 8.264 4.324 7.809 3.910 7.354 3.497 6.899 3.084 6.353 2.588
24 8.967 4.476 8.488 4.011 8.009 3.547 7.530 3.082 7.051 2.618 6.476 2.061
20 7.975 6.101 7.592 5.841 7.209 5.581 6.826 5.321 6.443 5.060 5.984 4.748
21 8.223 5.840 7.816 5.529 7.409 5.217 7.002 4.906 6.595 4.595 6.107 4.221
22 8.471 5.578 8.040 5.216 7.609 4.854 7.178 4.491 6.747 4.129 6.230 3.694
23 8.719 5.317 8.264 4.903 7.809 4.490 7.354 4.077 6.899 3.663 6.353 3.167
24 8.967 5.055 8.488 4.591 8.009 4.126 7.530 3.662 7.051 3.198 6.476 2.640
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 8.117 5.375 7.585 4.821 6.954 4.289 6.323 3.757 5.693 3.225 4.936 2.587
16 8.318 5.027 7.780 4.527 7.192 4.039 6.605 3.550 6.018 3.061 5.314 2.475
16 8.318 6.369 7.780 5.869 7.192 5.381 6.605 4.892 6.018 4.404 5.314 3.817
17 8.518 6.022 7.975 5.576 7.431 5.131 6.888 4.685 6.344 4.240 5.692 3.705
18 8.764 5.664 8.246 5.265 7.728 4.867 7.210 4.469 6.691 4.071 6.070 3.593
19 9.015 5.298 8.550 4.910 8.085 4.521 7.620 4.133 7.087 3.837 6.448 3.481
20 9.246 4.931 8.734 4.549 8.222 4.167 7.710 3.785 7.198 3.403 6.583 2.944
18 8.764 7.006 8.246 6.607 7.728 6.209 7.210 5.811 6.691 5.413 6.070 4.935
19 9.015 6.640 8.550 6.252 8.085 5.864 7.620 5.475 7.087 5.179 6.448 4.823
20 9.246 6.273 8.734 5.891 8.222 5.509 7.710 5.127 7.198 4.745 6.583 4.286
21 9.482 5.899 8.951 5.486 8.419 5.073 7.888 4.659 7.356 4.246 6.719 3.749
22 9.719 5.526 9.168 5.081 8.617 4.636 8.066 4.191 7.515 3.746 6.854 3.213
23 9.956 5.152 9.385 4.676 8.815 4.199 8.244 3.723 7.674 3.247 6.989 2.676
24 10.192 4.778 9.602 4.270 9.012 3.763 8.423 3.256 7.833 2.748 7.125 2.139
20 9.246 6.944 8.734 6.562 8.222 6.180 7.710 5.798 7.198 5.416 6.583 4.957
21 9.482 6.571 8.951 6.157 8.419 5.744 7.888 5.330 7.356 4.917 6.719 4.420
22 9.719 6.197 9.168 5.752 8.617 5.307 8.066 4.862 7.515 4.417 6.854 3.884
23 9.956 5.823 9.385 5.347 8.815 4.870 8.244 4.394 7.674 3.918 6.989 3.347
24 10.192 5.449 9.602 4.941 9.012 4.434 8.423 3.927 7.833 3.419 7.125 2.810
Outdoor DB°C · Outdoor DB°C

MODEL : A5CM 28E / A5LC 35C
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 8.685 5.958 8.373 5.617 8.022 5.364 7.670 5.111 7.318 4.858 6.897 4.555
16 9.015 5.683 8.659 5.401 8.283 5.162 7.907 4.923 7.531 4.684 7.079 4.398
16 9.015 7.025 8.659 6.743 8.283 6.504 7.907 6.265 7.531 6.026 7.079 5.740
17 9.345 6.751 8.944 6.526 8.544 6.302 8.143 6.077 7.743 5.852 7.262 5.583
18 9.693 6.435 9.261 6.241 8.828 6.047 8.396 5.853 7.964 5.659 7.445 5.426
19 10.051 6.097 9.634 5.821 9.218 5.546 8.801 5.271 8.268 5.270 7.628 5.269
20 10.389 5.781 9.889 5.539 9.389 5.296 8.888 5.053 8.388 4.810 7.788 4.519
18 9.693 7.777 9.261 7.583 8.828 7.389 8.396 7.195 7.964 7.001 7.445 6.768
19 10.051 7.439 9.634 7.163 9.218 6.888 8.801 6.613 8.268 6.612 7.628 6.611
20 10.389 7.123 9.889 6.881 9.389 6.638 8.888 6.395 8.388 6.152 7.788 5.861
21 10.737 6.786 10.200 6.463 9.664 6.141 9.128 5.819 8.592 5.497 7.948 5.110
22 11.084 6.448 10.512 6.046 9.940 5.645 9.367 5.243 8.795 4.842 8.108 4.360
23 11.432 6.110 10.823 5.629 10.215 5.148 9.607 4.667 8.998 4.186 8.269 3.609
24 11.779 5.772 11.135 5.212 10.491 4.652 9.846 4.091 9.202 3.531 8.429 2.858
20 10.389 7.794 9.889 7.552 9.389 7.309 8.888 7.066 8.388 6.823 7.788 6.532
21 10.737 7.457 10.200 7.135 9.664 6.812 9.128 6.490 8.592 6.168 7.948 5.781
22 11.084 7.119 10.512 6.717 9.940 6.316 9.367 5.914 8.795 5.513 8.108 5.031
23 11.432 6.781 10.823 6.300 10.215 5.819 9.607 5.338 8.998 4.857 8.269 4.280
24 11.779 6.444 11.135 5.883 10.491 5.323 9.846 4.762 9.202 4.202 8.429 3.529
Outdoor DB°C

MODEL : A5CM 15ER / A5LC 15CR COOLING MODE
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 4.362 2.573 3.980 2.190 3.593 1.802 3.206 1.414 2.819 1.027 2.354 0.562
16 4.440 2.359 4.074 2.005 3.706 1.648 3.338 1.292 2.970 0.936 2.528 0.508
16 4.440 3.385 4.074 3.031 3.706 2.675 3.338 2.318 2.970 1.962 2.528 1.534
17 4.517 3.171 4.168 2.846 3.819 2.521 3.470 2.196 3.121 1.871 2.702 1.481
18 4.597 2.960 4.266 2.665 3.935 2.370 3.604 2.075 3.273 1.781 2.876 1.427
19 4.679 2.753 4.380 2.515 4.082 2.276 3.783 2.038 3.450 1.736 3.050 1.373
20 4.752 2.529 4.437 2.257 4.122 1.986 3.807 1.714 3.492 1.443 3.114 1.117
18 4.597 3.986 4.266 3.691 3.935 3.396 3.604 3.102 3.273 2.807 2.876 2.453
19 4.679 3.779 4.380 3.541 4.082 3.302 3.783 3.064 3.450 2.762 3.050 2.400
20 4.752 3.555 4.437 3.283 4.122 3.012 3.807 2.740 3.492 2.469 3.114 2.143
21 4.827 3.336 4.510 3.057 4.193 2.778 3.876 2.500 3.559 2.221 3.178 1.887
22 4.903 3.116 4.583 2.831 4.264 2.545 3.945 2.259 3.625 1.974 3.242 1.631
23 4.978 2.897 4.657 2.604 4.335 2.312 4.014 2.019 3.692 1.726 3.306 1.374
24 5.054 2.678 4.730 2.378 4.406 2.078 4.082 1.778 3.759 1.478 3.370 1.118
20 4.752 4.068 4.437 3.796 4.122 3.525 3.807 3.254 3.492 2.982 3.114 2.656
21 4.827 3.849 4.510 3.570 4.193 3.292 3.876 3.013 3.559 2.734 3.178 2.400
22 4.903 3.630 4.583 3.344 4.264 3.058 3.945 2.772 3.625 2.487 3.242 2.144
23 4.978 3.410 4.657 3.117 4.335 2.825 4.014 2.532 3.692 2.239 3.306 1.887
24 5.054 3.191 4.730 2.891 4.406 2.591 4.082 2.291 3.759 1.991 3.370 1.631
-9 -6 -5 6 12 15 18
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 2.091 2.091 2.366 2.366 2.458 2.458 3.469 3.469 4.020 4.020 4.296 4.296 4.571 4.571
17 2.036 2.036 2.334 2.334 2.405 2.405 3.465 3.465 3.974 3.974 4.251 4.251 4.527 4.527
19 1.981 1.981 2.302 2.302 2.352 2.352 3.460 3.460 3.927 3.927 4.205 4.205 4.484 4.484
21 1.926 1.926 2.252 2.252 2.299 2.299 3.418 3.418 3.881 3.881 4.160 4.160 4.440 4.440
23 1.871 1.871 2.183 2.183 2.245 2.245 3.338 3.338 3.835 3.835 4.115 4.115 4.396 4.396
25 1.817 1.817 2.114 2.114 2.192 2.192 3.257 3.257 3.789 3.789 4.070 4.070 4.352 4.352
27 1.762 1.762 2.045 2.045 2.139 2.139 3.177 3.177 3.742 3.742 4.025 4.025 4.308 4.308
Outdoor DB°C · Outdoor WB°C

MODEL : A5CM 20ER / A5LC 20CR (1 PHASE) COOLING MODE
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 5.715 3.788 5.176 3.247 4.622 2.692 4.068 2.137 3.514 1.581 2.849 0.915
16 5.842 3.492 5.340 2.990 4.830 2.481 4.320 1.971 3.811 1.462 3.199 0.850
16 5.842 4.601 5.340 4.099 4.830 3.590 4.320 3.080 3.811 2.570 3.199 1.959
17 5.968 4.306 5.503 3.842 5.038 3.378 4.573 2.914 4.107 2.451 3.549 1.894
18 6.102 4.017 5.678 3.596 5.255 3.176 4.831 2.755 4.408 2.334 3.899 1.829
19 6.238 3.737 5.868 3.403 5.498 3.068 5.128 2.733 4.729 2.293 4.249 1.764
20 6.360 3.431 5.971 3.051 5.582 2.671 5.194 2.290 4.805 1.910 4.339 1.454
18 6.102 5.126 5.678 4.705 5.255 4.285 4.831 3.864 4.408 3.443 3.899 2.938
19 6.238 4.846 5.868 4.512 5.498 4.177 5.128 3.842 4.729 3.402 4.249 2.873
20 6.360 4.540 5.971 4.160 5.582 3.780 5.194 3.399 4.805 3.019 4.339 2.563
21 6.484 4.243 6.088 3.860 5.693 3.477 5.298 3.094 4.902 2.712 4.428 2.252
22 6.608 3.945 6.206 3.560 5.804 3.175 5.402 2.789 4.999 2.404 4.517 1.942
23 6.732 3.648 6.323 3.260 5.914 2.872 5.505 2.484 5.097 2.097 4.606 1.631
24 6.856 3.350 6.440 2.960 6.025 2.570 5.609 2.180 5.194 1.789 4.695 1.321
20 6.360 5.095 5.971 4.714 5.582 4.334 5.194 3.954 4.805 3.574 4.339 3.117
21 6.484 4.797 6.088 4.414 5.693 4.032 5.298 3.649 4.902 3.266 4.428 2.807
22 6.608 4.500 6.206 4.115 5.804 3.729 5.402 3.344 4.999 2.959 4.517 2.496
23 6.732 4.202 6.323 3.815 5.914 3.427 5.505 3.039 5.097 2.651 4.606 2.186
24 6.856 3.905 6.440 3.515 6.025 3.124 5.609 2.734 5.194 2.344 4.695 1.875
-9 -6 -5 6 12 15 18
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 3.278 3.278 3.710 3.710 3.854 3.854 5.438 5.438 6.302 6.302 6.735 6.735 7.167 7.167
17 3.192 3.192 3.680 3.680 3.770 3.770 5.432 5.432 6.228 6.228 6.662 6.662 7.096 7.096
19 3.106 3.106 3.649 3.649 3.686 3.686 5.425 5.425 6.154 6.154 6.589 6.589 7.025 7.025
21 3.020 3.020 3.573 3.573 3.603 3.603 5.358 5.358 6.080 6.080 6.517 6.517 6.954 6.954
23 2.934 2.934 3.450 3.450 3.519 3.519 5.229 5.229 6.005 6.005 6.444 6.444 6.883 6.883
25 2.848 2.848 3.327 3.327 3.435 3.435 5.101 5.101 5.931 5.931 6.371 6.371 6.812 6.812
27 2.762 2.762 3.204 3.204 3.352 3.352 4.973 4.973 5.857 5.857 6.299 6.299 6.741 6.741
Outdoor DB°C · Outdoor WB°C

MODEL : A5CM 20ER / A5LC 20CR (3 PHASE) COOLING MODE
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 5.670 3.743 5.205 3.276 4.741 2.812 4.278 2.347 3.815 1.883 3.258 1.325
16 5.833 3.471 5.392 3.044 4.951 2.617 4.511 2.190 4.071 1.763 3.543 1.251
16 5.833 4.580 5.392 4.153 4.951 3.726 4.511 3.299 4.071 2.872 3.543 2.360
17 5.995 4.309 5.578 3.920 5.161 3.531 4.744 3.142 4.327 2.753 3.827 2.286
18 6.157 4.037 5.764 3.686 5.370 3.335 4.977 2.984 4.584 2.633 4.111 2.212
19 6.324 3.766 5.984 3.463 5.644 3.159 5.304 2.855 4.891 2.529 4.396 2.137
20 6.473 3.482 6.091 3.155 5.710 2.828 5.328 2.501 4.946 2.174 4.488 1.782
18 6.157 5.146 5.764 4.795 5.370 4.444 4.977 4.093 4.584 3.742 4.111 3.321
19 6.324 4.875 5.984 4.572 5.644 4.268 5.304 3.964 4.891 3.638 4.396 3.246
20 6.473 4.591 6.091 4.264 5.710 3.937 5.328 3.610 4.946 3.283 4.488 2.891
21 6.627 4.308 6.234 3.967 5.840 3.627 5.446 3.286 5.053 2.945 4.580 2.536
22 6.782 4.025 6.376 3.671 5.971 3.316 5.565 2.961 5.159 2.607 4.673 2.181
23 6.936 3.743 6.519 3.374 6.101 3.005 5.684 2.637 5.266 2.268 4.765 1.826
24 7.091 3.460 6.661 3.077 6.232 2.695 5.802 2.312 5.373 1.930 4.857 1.471
20 6.473 5.145 6.091 4.818 5.710 4.492 5.328 4.165 4.946 3.838 4.488 3.446
21 6.627 4.863 6.234 4.522 5.840 4.181 5.446 3.840 5.053 3.499 4.580 3.091
22 6.782 4.580 6.376 4.225 5.971 3.870 5.565 3.516 5.159 3.161 4.673 2.735
23 6.936 4.297 6.519 3.929 6.101 3.560 5.684 3.191 5.266 2.823 4.765 2.380
24 7.091 4.014 6.661 3.632 6.232 3.249 5.802 2.867 5.373 2.484 4.857 2.025
-9 -6 -5 6 12 15 18
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 3.326 3.326 3.764 3.764 3.910 3.910 5.518 5.518 6.394 6.394 6.833 6.833 7.271 7.271
17 3.238 3.238 3.712 3.712 3.823 3.823 5.511 5.511 6.306 6.306 6.745 6.745 7.183 7.183
19 3.151 3.151 3.660 3.660 3.735 3.735 5.504 5.504 6.218 6.218 6.656 6.656 7.094 7.094
21 3.064 3.064 3.578 3.578 3.648 3.648 5.428 5.428 6.130 6.130 6.568 6.568 7.006 7.006
23 2.977 2.977 3.465 3.465 3.561 3.561 5.282 5.282 6.042 6.042 6.480 6.480 6.918 6.918
25 2.890 2.890 3.353 3.353 3.473 3.473 5.136 5.136 5.954 5.954 6.392 6.392 6.829 6.829
27 2.803 2.803 3.240 3.240 3.386 3.386 4.991 4.991 5.866 5.866 6.303 6.303 6.741 6.741
Outdoor DB°C · Outdoor WB°C

MODEL : A5CM 25ER / A5LC 25CR (1 PHASE) COOLING MODE
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 5.924 4.060 5.602 3.715 5.279 3.405 4.956 3.096 4.633 2.787 4.246 2.416
16 6.138 3.823 5.810 3.519 5.481 3.233 5.153 2.947 4.824 2.662 4.430 2.319
16 6.138 4.870 5.810 4.566 5.481 4.281 5.153 3.995 4.824 3.710 4.430 3.367
17 6.352 4.633 6.018 4.371 5.684 4.109 5.349 3.847 5.015 3.585 4.614 3.270
18 6.567 4.378 6.227 4.146 5.886 3.915 5.546 3.683 5.206 3.452 4.798 3.174
19 6.789 4.112 6.479 3.854 6.170 3.595 5.860 3.337 5.461 3.219 4.981 3.077
20 6.993 3.855 6.626 3.616 6.260 3.378 5.893 3.140 5.526 2.901 5.086 2.615
18 6.567 5.426 6.227 5.194 5.886 4.963 5.546 4.731 5.206 4.499 4.798 4.221
19 6.789 5.160 6.479 4.901 6.170 4.643 5.860 4.385 5.461 4.267 4.981 4.125
20 6.993 4.903 6.626 4.664 6.260 4.426 5.893 4.187 5.526 3.949 5.086 3.663
21 7.205 4.634 6.817 4.359 6.430 4.083 6.043 3.807 5.655 3.532 5.191 3.201
22 7.416 4.366 7.008 4.053 6.600 3.740 6.193 3.427 5.785 3.114 5.295 2.739
23 7.628 4.098 7.199 3.748 6.771 3.397 6.342 3.047 5.914 2.697 5.400 2.277
24 7.839 3.829 7.390 3.442 6.941 3.055 6.492 2.667 6.043 2.280 5.504 1.815
20 6.993 5.427 6.626 5.188 6.260 4.950 5.893 4.711 5.526 4.473 5.086 4.187
21 7.205 5.158 6.817 4.883 6.430 4.607 6.043 4.331 5.655 4.056 5.191 3.725
22 7.416 4.890 7.008 4.577 6.600 4.264 6.193 3.951 5.785 3.638 5.295 3.263
23 7.628 4.622 7.199 4.271 6.771 3.921 6.342 3.571 5.914 3.221 5.400 2.801
24 7.839 4.353 7.390 3.966 6.941 3.578 6.492 3.191 6.043 2.804 5.504 2.339
-9 -6 -5 6 12 15 18
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 3.898 3.898 4.412 4.412 4.583 4.583 6.467 6.467 7.495 7.495 8.009 8.009 8.523 8.523
17 3.796 3.796 4.347 4.347 4.488 4.488 6.459 6.459 7.431 7.431 7.950 7.950 8.470 8.470
19 3.694 3.694 4.282 4.282 4.393 4.393 6.452 6.452 7.367 7.367 7.892 7.892 8.417 8.417
21 3.591 3.591 4.190 4.190 4.298 4.298 6.387 6.387 7.304 7.304 7.834 7.834 8.364 8.364
23 3.489 3.489 4.071 4.071 4.204 4.204 6.264 6.264 7.240 7.240 7.776 7.776 8.312 8.312
25 3.387 3.387 3.951 3.951 4.109 4.109 6.142 6.142 7.176 7.176 7.718 7.718 8.259 8.259
27 3.285 3.285 3.832 3.832 4.014 4.014 6.019 6.019 7.113 7.113 7.659 7.659 8.206 8.206
Outdoor DB°C · Outdoor WB°C

MODEL : A5CM 25ER / A5LC 25CR (3 PHASE) COOLING MODE
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 6.763 4.405 6.436 4.061 6.057 3.765 5.677 3.469 5.298 3.173 4.842 2.818
16 6.992 4.182 6.649 3.879 6.279 3.600 5.910 3.321 5.540 3.042 5.097 2.708
16 6.992 5.341 6.649 5.038 6.279 4.759 5.910 4.480 5.540 4.201 5.097 3.867
17 7.221 5.117 6.861 4.855 6.502 4.594 6.142 4.332 5.783 4.071 5.351 3.757
18 7.474 4.871 7.115 4.635 6.755 4.400 6.396 4.164 6.037 3.929 5.606 3.646
19 7.730 4.623 7.386 4.406 7.042 4.188 6.699 3.971 6.318 3.773 5.860 3.536
20 7.975 4.363 7.592 4.103 7.209 3.842 6.826 3.582 6.443 3.322 5.984 3.009
18 7.474 6.030 7.115 5.794 6.755 5.559 6.396 5.323 6.037 5.088 5.606 4.805
19 7.730 5.782 7.386 5.565 7.042 5.347 6.699 5.130 6.318 4.932 5.860 4.695
20 7.975 5.522 7.592 5.262 7.209 5.001 6.826 4.741 6.443 4.481 5.984 4.168
21 8.223 5.260 7.816 4.949 7.409 4.638 7.002 4.326 6.595 4.015 6.107 3.641
22 8.471 4.999 8.040 4.636 7.609 4.274 7.178 3.912 6.747 3.549 6.230 3.115
23 8.719 4.737 8.264 4.324 7.809 3.910 7.354 3.497 6.899 3.084 6.353 2.588
24 8.967 4.476 8.488 4.011 8.009 3.547 7.530 3.082 7.051 2.618 6.476 2.061
20 7.975 6.101 7.592 5.841 7.209 5.581 6.826 5.321 6.443 5.060 5.984 4.748
21 8.223 5.840 7.816 5.529 7.409 5.217 7.002 4.906 6.595 4.595 6.107 4.221
22 8.471 5.578 8.040 5.216 7.609 4.854 7.178 4.491 6.747 4.129 6.230 3.694
23 8.719 5.317 8.264 4.903 7.809 4.490 7.354 4.077 6.899 3.663 6.353 3.167
24 8.967 5.055 8.488 4.591 8.009 4.126 7.530 3.662 7.051 3.198 6.476 2.640
-9 -6 -5 6 12 15 18
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 4.110 4.110 4.652 4.652 4.833 4.833 6.820 6.820 7.904 7.904 8.446 8.446 8.987 8.987
17 4.003 4.003 4.538 4.538 4.724 4.724 6.812 6.812 7.790 7.790 8.331 8.331 8.872 8.872
19 3.895 3.895 4.424 4.424 4.615 4.615 6.804 6.804 7.676 7.676 8.216 8.216 8.756 8.756
21 3.787 3.787 4.315 4.315 4.506 4.506 6.706 6.706 7.562 7.562 8.102 8.102 8.641 8.641
23 3.679 3.679 4.210 4.210 4.397 4.397 6.520 6.520 7.448 7.448 7.987 7.987 8.525 8.525
25 3.572 3.572 4.105 4.105 4.288 4.288 6.334 6.334 7.335 7.335 7.872 7.872 8.410 8.410
27 3.464 3.464 4.001 4.001 4.180 4.180 6.147 6.147 7.221 7.221 7.758 7.758 8.294 8.294
Outdoor DB°C · Outdoor WB°C

MODEL : A5CM 28ER / A5LC 28CR COOLING MODE
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 8.117 5.375 7.585 4.821 6.954 4.289 6.323 3.757 5.693 3.225 4.936 2.587
16 8.318 5.027 7.780 4.527 7.192 4.039 6.605 3.550 6.018 3.061 5.314 2.475
16 8.318 6.369 7.780 5.869 7.192 5.381 6.605 4.892 6.018 4.404 5.314 3.817
17 8.518 6.022 7.975 5.576 7.431 5.131 6.888 4.685 6.344 4.240 5.692 3.705
18 8.764 5.664 8.246 5.265 7.728 4.867 7.210 4.469 6.691 4.071 6.070 3.593
19 9.015 5.298 8.550 4.910 8.085 4.521 7.620 4.133 7.087 3.837 6.448 3.481
20 9.246 4.931 8.734 4.549 8.222 4.167 7.710 3.785 7.198 3.403 6.583 2.944
18 8.764 7.006 8.246 6.607 7.728 6.209 7.210 5.811 6.691 5.413 6.070 4.935
19 9.015 6.640 8.550 6.252 8.085 5.864 7.620 5.475 7.087 5.179 6.448 4.823
20 9.246 6.273 8.734 5.891 8.222 5.509 7.710 5.127 7.198 4.745 6.583 4.286
21 9.482 5.899 8.951 5.486 8.419 5.073 7.888 4.659 7.356 4.246 6.719 3.749
22 9.719 5.526 9.168 5.081 8.617 4.636 8.066 4.191 7.515 3.746 6.854 3.213
23 9.956 5.152 9.385 4.676 8.815 4.199 8.244 3.723 7.674 3.247 6.989 2.676
24 10.192 4.778 9.602 4.270 9.012 3.763 8.423 3.256 7.833 2.748 7.125 2.139
20 9.246 6.944 8.734 6.562 8.222 6.180 7.710 5.798 7.198 5.416 6.583 4.957
21 9.482 6.571 8.951 6.157 8.419 5.744 7.888 5.330 7.356 4.917 6.719 4.420
22 9.719 6.197 9.168 5.752 8.617 5.307 8.066 4.862 7.515 4.417 6.854 3.884
23 9.956 5.823 9.385 5.347 8.815 4.870 8.244 4.394 7.674 3.918 6.989 3.347
24 10.192 5.449 9.602 4.941 9.012 4.434 8.423 3.927 7.833 3.419 7.125 2.810
-9 -6 -5 6 12 15 18
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 4.695 4.695 5.314 5.314 5.520 5.520 7.790 7.790 9.028 9.028 9.647 9.647 10.266 10.266
17 4.572 4.572 5.287 5.287 5.408 5.408 7.781 7.781 8.961 8.961 9.589 9.589 10.216 10.216
19 4.449 4.449 5.260 5.260 5.296 5.296 7.771 7.771 8.895 8.895 9.530 9.530 10.165 10.165
21 4.326 4.326 5.157 5.157 5.184 5.184 7.699 7.699 8.829 8.829 9.472 9.472 10.115 10.115
23 4.203 4.203 4.980 4.980 5.071 5.071 7.564 7.564 8.762 8.762 9.414 9.414 10.065 10.065
25 4.080 4.080 4.802 4.802 4.959 4.959 7.429 7.429 8.696 8.696 9.356 9.356 10.015 10.015
27 3.957 3.957 4.624 4.624 4.847 4.847 7.295 7.295 8.630 8.630 9.297 9.297 9.965 9.965
Outdoor DB°C · Outdoor WB°C

MODEL : A5CM 28ER / A5LC 35CR COOLING MODE
20 25 30 35 40 46
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 8.685 5.958 8.373 5.617 8.022 5.364 7.670 5.111 7.318 4.858 6.897 4.555
16 9.015 5.683 8.659 5.401 8.283 5.162 7.907 4.923 7.531 4.684 7.079 4.398
16 9.015 7.025 8.659 6.743 8.283 6.504 7.907 6.265 7.531 6.026 7.079 5.740
17 9.345 6.751 8.944 6.526 8.544 6.302 8.143 6.077 7.743 5.852 7.262 5.583
18 9.693 6.435 9.261 6.241 8.828 6.047 8.396 5.853 7.964 5.659 7.445 5.426
19 10.051 6.097 9.634 5.821 9.218 5.546 8.801 5.271 8.268 5.270 7.628 5.269
20 10.389 5.781 9.889 5.539 9.389 5.296 8.888 5.053 8.388 4.810 7.788 4.519
18 9.693 7.777 9.261 7.583 8.828 7.389 8.396 7.195 7.964 7.001 7.445 6.768
19 10.051 7.439 9.634 7.163 9.218 6.888 8.801 6.613 8.268 6.612 7.628 6.611
20 10.389 7.123 9.889 6.881 9.389 6.638 8.888 6.395 8.388 6.152 7.788 5.861
21 10.737 6.786 10.200 6.463 9.664 6.141 9.128 5.819 8.592 5.497 7.948 5.110
22 11.084 6.448 10.512 6.046 9.940 5.645 9.367 5.243 8.795 4.842 8.108 4.360
23 11.432 6.110 10.823 5.629 10.215 5.148 9.607 4.667 8.998 4.186 8.269 3.609
24 11.779 5.772 11.135 5.212 10.491 4.652 9.846 4.091 9.202 3.531 8.429 2.858
20 10.389 7.794 9.889 7.552 9.389 7.309 8.888 7.066 8.388 6.823 7.788 6.532
21 10.737 7.457 10.200 7.135 9.664 6.812 9.128 6.490 8.592 6.168 7.948 5.781
22 11.084 7.119 10.512 6.717 9.940 6.316 9.367 5.914 8.795 5.513 8.108 5.031
23 11.432 6.781 10.823 6.300 10.215 5.819 9.607 5.338 8.998 4.857 8.269 4.280
24 11.779 6.444 11.135 5.883 10.491 5.323 9.846 4.762 9.202 4.202 8.429 3.529
-9 -6 -5 6 12 15 18
TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW)
15 5.492 5.492 6.217 6.217 6.458 6.458 9.113 9.113 10.561 10.561 11.285 11.285 12.009 12.009
17 5.348 5.348 6.075 6.075 6.285 6.285 9.102 9.102 10.264 10.264 10.966 10.966 11.668 11.668
19 5.204 5.204 5.933 5.933 6.112 6.112 9.091 9.091 9.967 9.967 10.647 10.647 11.328 11.328
21 5.061 5.061 5.770 5.770 5.938 5.938 8.872 8.872 9.670 9.670 10.328 10.328 10.987 10.987
23 4.917 4.917 5.587 5.587 5.765 5.765 8.446 8.446 9.373 9.373 10.010 10.010 10.646 10.646
25 4.773 4.773 5.404 5.404 5.592 5.592 8.020 8.020 9.076 9.076 9.691 9.691 10.306 10.306
27 4.629 4.629 5.221 5.221 5.419 5.419 7.593 7.593 8.779 8.779 9.372 9.372 9.965 9.965
Outdoor DB°C · Outdoor WB°C

INDOOR UNIT
ACM 15/20/25/28E/ER A5CM 15/20/25/28E/ER




For 25/28 C/CR Only
MODEL A B C D E F G H I J K L M N O P Q R S T
855 628 328 508 181 44 93 149 101 113 603 126 164 17 49 32 3 23 73 75
ALC / A5LC 25/28 C/CR
855 730 328 513 182 44 93 149 101 113 603 126 164 17 47 32 3 23 73 75


ELECTRICAL DATA - COOLING ONLY (R22)














RATED INPUT POWER W 1502 / 1732 /
RATED RUNNING CURRENT A 6.6 / 7.8 /
LOCKED ROTOR AMP. A 27 / 63 /

MODEL
A5LC 28C A5LC 35C
INSULATION GRADE CLASS B
POWER SOURCE V/Ph/Hz
INDOOR MOTOR
RATED RUNNING CURRENT A
MOTOR OUTPUT W
POLES 4
INSULATION GRADE CLASS B
POWER SOURCE V/Ph/Hz
OUTDOOR MOTOR
RATED RUNNING CURRENT A 0.62 1.06
MOTOR OUTPUT W 75 145
POLES
INSULATION GRADE
CLASS E -
POWER SOURCE V/Ph/Hz
CAPACITOR mF 45.0 / 60.0 /
RATED INPUT POWER W 2378 / 2547 /
RATED RUNNING CURRENT A 11.30 / 12.70 /
LOCKED ROTOR AMP. A 65 / 97 /



RATED INPUT POWER (COOLING) W 1502 / 1732 /
RATED INPUT POWER (HEATING) W 1272 / 1762 /
RATED RUNNING CURRENT (COOLING) A 6.6 / 7.8 /
RATED RUNNING CURRENT (HEATING) A 5.6 / 8.0 /
LOCKED ROTOR AMP. A 27 / 63 /

MODEL
A5LC 28CR A5LC 35CR
INSULATION GRADE CLASS B
POWER SOURCE V/Ph/Hz
INDOOR MOTOR
RATED RUNNING CURRENT A
MOTOR OUTPUT W
POLES 4
INSULATION GRADE CLASS B
POWER SOURCE V/Ph/Hz
OUTDOOR MOTOR
RATED RUNNING CURRENT A 0.62 1.06
MOTOR OUTPUT W 75 145
POLES
INSULATION GRADE
CLASS E -
POWER SOURCE V/Ph/Hz
CAPACITOR mF 45.0 / 60.0 /
RATED INPUT POWER (COOLING) W 2378 / 2547 /
RATED INPUT POWER (HEATING) W 2128 / 2407 /
RATED RUNNING CURRENT (COOLING) A 11.30 / 12.70 /
RATED RUNNING CURRENT (HEATING) A 10.30 / 11.80 /
LOCKED ROTOR AMP. A 65 / 97 /

COOLING ONLY
INDOOR UNIT MODEL: ACM / A5CM 15E



ALC / A5LC 20/25C







INDOOR UNIT MODEL: ACM / A5CM 15ER



ALC / A5LC 20/25CR










Warning : Disconnect from main supply before servicing the air conditioner
The unit is designed to give long life operation with minimum maintenance required. However, it should be regularly checked and the following items should be given due attention.
Indoor Air Filter 1. Remove any dust adhering on the filter by using a vacuum cleaner or wash in lukewarm water (below 40°C/104°F) with a neutral cleaning detergent. 2. Rinse the filter well and dry before placing it back onto the unit. 3. Note :Do not use gasoline, volatile substances or chemicals to clean the filter.
At least once every 2 weeks. More frequently if necessary.
Indoor Unit 1. Clean any dirt or dust on the grille or panel by wiping it with a soft cloth soaked in lukewarm water (below 40°C/104°F) and a neutral detergent solution. 2. Note : Do not use gasoline, volatile substances or chemicals to clean the indoor unit.
Condensate Drain Pan and Pipe
Indoor Fan 1. Check for unusual noise. As necessary.
Every month. Every month.
Electrical 1. Check voltage, current and wiring. 2. Check faulty contacts caused by loose connections, foreign matters, etc.
Every 2 months. Every 2 months.
Compressor 1. No maintenance needed if refrigerant circuit remains sealed. However, check for refrigerant leak at joints and fittings.
Every 6 months.
No maintenance required.

– Inspect thoroughly and clean indoor and outdoor units. – Clean or replace air filters. – Clean condensate drain line. – Clean clogged indoor and outdoor coils. – Check fan imbalance before operation. – Tighten all wiring connections and panels. – Check for refrigerant leakage.
The design of the ALC outdoor series allows servicing to be carried out readily and easily. The removal of the top/front and back panel make almost every part accessible.

Under normal circumstances, these outdoor units only require a check and cleaning of air intake coil surface once quar- terly. However, if a unit is installed in areas subjected to much oil mist and dust, the coils must be regularly cleaned by qualified Air Conditioner Service Technicians to ensure sufficient heat exchange and proper operation. Otherwise, the systems life span may be shortened.
Do not charge OXYGEN, ACETYLENE OR OTHER FLAMMABLE and poisonous gases into the unit when performing a leakage test or an airtight test. These gases could cause severe explosion and damage if exposed to high temperature and pressure. It is recommended that only nitrogen or refrigerant be charged when performing the leakage or airtight test.

When a malfunction of the air conditioner unit is detected, immediately switch off the main power supply before proceeding with the following troubleshooting procedures. The following are common fault conditions and simple troubleshooting tips. If any other fault conditions which are not listed occur, contact your nearest local dealer. DO NOT attempt to troubleshoot the unit by yourself.
1 The air conditioner unit will not resume after power failure.
2 The compressor does not operate 3 minutes after the air conditioner unit is started.
3 The airflow is too slow or room cannot be cooled sufficiently.
5 Condensation on the front air grille of the indoor unit.
6 Water flowing out from the air conditioner. • Switch off the unit and contact your nearest dealer. This might be due to tilted installation.
7 Hissing airflow sound from the air conditioner unit during operation.
10 No cool air comes out during cooling cycle, or no hot air comes out during heating cycle.
11 On heating cycle, warm air does not come out. • Unit is in defrost mode. Heating operation will resume after defrost cycle ends.

Pressure
Data
A little high
A little low
Too high
Probable cause
Too low
Normal
Circuit
●
High side Low side
High side Low side
High side Low side

By means of diagnostic flow chart: Generally, there are two kinds of problems, i.e. starting failure and insufficient cooling/heating. “Starting failure” is caused by electrical defect while improper application or defects in refrigerant circuit causes “Insufficient cooling / heating”.

The most common causes of air conditioner failure to “start” are : a) Voltage not within ±10% of rated voltage. b) Power supply interrupted. c) Improper control settings. d) Air conditioner is disconnected from main power source. e) Fuse blown or circuit breaker off.

There might be some causes where the unit starts running but does not perform satisfactorily, i.e. insufficient cooling. Judgement could be made by measuring temperature difference of indoor unit’s intake and discharge air as well as running current.

Satisfactory operation with temperature difference of air intake & discharge of indoor unit 8°C to 13°C. * ( * value is for reference only )


Satisfactory operation with temperature difference of air intake & discharge of indoor unit 14°C to 20°C. * ( * value is for reference only )

MODEL: ACM / A5CM 15/20/25/28 E/ER

1 Assy., Top Panel R50124074907 8 Motor, Bracket R01014071324
2 Assy., Coil 9 Blower Wheel R03024004754
ACM / A5CM 15E/ER R50024085233 10 Blower Housing R12014071385
ACM 20E/ER, A5CM 25E/ER R50024071828 11 Motor, Air Swing R03039023303
A5CM 20E/ER R50024080385 12 Assy., Bottom Panel R50124074909
ACM 25E/ER, ACM 28ER,A5CM 28E/ER R50024074757 13 Cover, Hanger L1 (C) R12014071354
ACM 28E R50024075729 14 Cover, Hanger L2 (D) R12014071355
3 Assy., Vane R50124074906 15 Cover, Hanger R1 (A) R12014071356
4 Assy., Drain Pan 16 Cover, Hanger R2 (B) R12014071357
ACM / A5CM 20/25/28E R50124076123 17 Mounting Bracket R01014071319
ACM / A5CM 20/25/28ER R50124080076 18 Control Module
5 Assy., Control Box ACM / A5CM 20/25/28E (IONIZER) R04089023399
ACM / A5CM 15/20/25/028E (IONIZER) R50044083484 ACM / A5CM 20/25/28E (NTP) R04089023670
ACM / A5CM 20/25/28E (NTP) R50044083700 ACM / A5CM 20/25/28ER (IONIZER) R04089023668
ACM / A5CM 15/20/25ER (IONIZER) R50044080078 ACM / A5CM 20/25/28ER (NTP) R04089023667
ACM / A5CM 20/25ER (NTP) R50044083701 19 G12 Handset (Cooling Only) R04084065327
ACM / A5CM 28ER (IONIZER) R50044080079 G12 Handset (Heatpump) R04084067315
ACM / A5CM 28ER (NTP) R50044083702 20 Louver R12014071335
6 Cover, Control Box R01014069872 21 Saranet Filter R12014071342
7 Motor 22 Assy., LED Board
ACM / A5CM 15E/ER R03034085800 ACM / A5CM 20/25/28E R50044076124
ACM / A5CM 20E/ER R03039023304 ACM / A5CM 20/25/28ER R50044080080
ACM / A5CM 25E/ER R03039023305 23 Air Intake Grille R12014071341


No Description Part No No Description Part No 1 Assy. Base Pan R50014051158 13 Assy., Control Panel R50044086056 2 Assy. Outdoor Coil 14 Assy., Valve Cover R50124051173 ALC 15C A50024087838 15 Assy., Front Grille R50124056700 A5LC 15C R50024084998 16 Plastic Handle R12014057948 3 Valve Bracket R01014051164 17 Rubber Grommet R11054000271 4 Compressor 18 Assy., Flare Valve 2 Ways 1/4" ALC 15C A04019027709 ALC 15C R50054054950 A5LC 15C R04019026326 A5LC 15C R50059019453 5 Assy., Partition R50064055063 19 Assy., Flare Valve 3 Ways 1/2" 6 Assy., Cap Tube R50024087757 ALC 15C R50054064042 7 Bracket, Fan Motor R01014051162 A5LC 15C R50059019452 8 Fan Motor R03039015323 Parts Not in Diagram 9 Fan Blade R03019015339 Capacitor, Fan Motor R04029026755 10 Left Panel R01014051166 Capacitor, Compressor 11 Right Panel R01014051167 ALC 15C R04029026775 12 Assy., Front Panel R01014051171 A5LC 15C R04029026776


No Description Part No No Description Part No 1 Assy. Base Pan R50014078281 10 Compressor 2 Assy. Outdoor Coil ALC 18/20C A04019027266 ALC 18C R50024089940 A5LC 20C R04019020625 ALC 20C A50024084570 11 Front Panel, Left R01014070597 A5LC 20C R50024079078 12 Service Panel R01014070598 3 Motor Bracket R01014070601 13 Terminal Cover Panel R01014070838 4 Fan Motor R03039024539 14 Assy. Control Panel R50014072877 5 Fan Blade R03019023393 15 Top Panel R01014070596 6 Valve Bracket 16 Assy. Front Grille R50124072880 ALC 18/20C A50014072861 17 Plastic Handle R12014057948 A5LC 20C R50014078280 18 Assy. Valve Cover R50124072885 7 ALC 18/20C 19 Assy. Cap Tube Assy. Flare Valve 3 Ways 5/8" R50054072863 ALC 18C R50024089926 A5LC 20C ALC 20C A50024087066 Assy. Flare Valve 3 Ways 1/2" R50059023335 A5LC 20C R50024081921 8 Assy. Flare Valve 2 Ways 1/4" 20 Partition R01014070603 ALC 18/20C R50059022156 Parts Not in Diagram A5LC 20C R50059023334 Capacitor, Fan Motor R04029026759 9 Back Panel, Right R01014070599 Capacitor, Compressor ALC 18/20C R04029026782 A5LC 20C R04029026779


No Description Part No No Description Part No 1 Assy. Base Pan R50014073884 10 Compressor 2 Assy. Outdoor Coil ALC 25C A04019027570 ALC 25C R50024089206 A5LC 25C R04019021361 A5LC 25/28C R50024079238 ALC 28C R04019012828 ALC 28C A50024070959 A5LC 28C R04019020449 3 Motor Bracket R01014070948 11 Front Panel, Left R01014070947 4 Fan Motor 12 Service Panel R01014070949 ALC 25C R03039028207 13 Terminal Cover Panel A01014070838 A5LC 25C R03039023391 14 Assy. Control Panel ALC / A5LC 28C R03039024538 ALC / A5LC 25C R50044086076 5 Fan Blade R03019023393 ALC 28C R50044086137 6 Valve Bracket A5LC 28C R50044086138 ALC 25/28C A50014073890 15 Top Panel R01014070596 A5LC 25C R50014078321 16 Assy. Front Grille R50124072880 A5LC 28C R50014080371 17 Plastic Handle, Side R12014057948 7 Assy. Flare Valve 3 Ways 5/8" 18 Assy. Valve Cover R50124073905 ALC 25/28C R50054072863 19 Assy. Cap Tube A5LC 25/28C R50059023336 ALC 25C R50024090095 8 ALC 25/028C A5LC 25C R50024081916 Assy. Flare Valve 3 Ways 3/8" R50059022577 A5LC 28C R50024079593 A5LC 25C 20 Partition R01014070951 Assy. Flare Valve 2 Ways 1/4" R50059023334 21 Plastic Handle, Front R12014070955 A5LC 28C Parts Not in Diagram Assy. Flare Valve 3 Ways 3/8" R50059024820 Capacitor, Fan Motor 9 Back Panel, Right R01014070950 ALC / A5LC 25C R04029026759 ALC / A5LC 28C R04029026966 Capacitor, Compressor ALC / A5LC 25C, ALC 28C R04029026779 A5LC 28C R04029026778


No Description Part No No Description Part No 1 Assy. Base Pan R50014051158 11 Left Panel R01014051166 2 Assy. Outdoor Coil 12 Right Panel R01014051167 ALC 15CR A50024086953 13 Assy., Front Panel R01014051171 A5LC 15CR R50024084998 14 Assy., Control Panel R50044086063 3 Valve Bracket R01014051164 15 Assy., Valve Cover R50124051173 4 Compressor 16 Assy., Front Grille R50124056700 ALC 15CR R04019019125 17 Plastic Handle R12014057948 A5LC 15CR R04019026326 18 Rubber Grommet R11054000271 5 Assy., Partition R50064055063 19 Assy., Flare Valve 2 Ways 1/4" 6 Assy., 4 Way Valve ALC 15CR R50054054950 ALC 15CR A50024087158 A5LC 15CR R50059019453 A5LC 15CR R50024084737 20 Assy., Flare Valve 3 Ways 1/2" 7 Assy., Cap Tube ALC 15CR R50054064042 ALC 15CR A50024087023 A5LC 15CR R50059019452 A5LC 15CR R50024084738 21 Sensor, Outdoor Defrost R50134039416 8 Bracket, Fan Motor R01014051162 Parts Not in Diagram 9 Fan Motor R03039015323 Capacitor, Fan Motor R04029026755 10 Fan Blade R03019015339 Capacitor, Compressor R04029026776


No Description Part No No Description Part No 1 Assy. Base Pan R50014078281 11 Front Panel, Left R01014070597 2 Assy. Outdoor Coil 12 Service Panel R01014070598 ALC 18CR R50024090296 13 Terminal Cover Panel R01014070838 ALC / A5LC 20CR R50024075143 14 Assy. Control Panel R50014072877 3 Motor Bracket R01014070601 15 Top Panel R01014070596 4 Fan Motor R03039024539 16 Assy. Front Grille R50124072880 5 Fan Blade R03019023393 17 Plastic Handle R12014057948 6 Valve Bracket 18 Assy. Valve Cover R50124072885 ALC 18/20CR A50014072861 19 Assy. Cap Tube A5LC 20CR R50014078280 ALC 18CR R50024089931 7 ALC 18/20CR ALC 20CR R50024087058 Assy. Flare Valve 3 Ways 5/8" R50054072863 A5LC 20CR R50024081904 A5LC 20CR 20 Assy. 4 Way Valve Assy. Flare Valve 3 Ways 1/2" R50059023335 ALC 18/20CR R50054077222 8 Assy. Flare Valve 2 Ways 1/4" A5LC 20CR R50059024520 ALC 18/20CR R50059022156 21 Partition R01014070603 A5LC 20CR R50059023334 Parts Not in Diagram 9 Back Panel, Right R01014070599 Capacitor, Fan Motor R04029026759 10 Compressor Capacitor, Compressor ALC 18/20CR A04019027266 ALC 18/20CR R04029026782 A5LC 20CR R04019020625 A5LC 20CR R04029026779


No Description Part No No Description Part No 1 Assy. Base Pan R50014073884 11 Front Panel, Left R01014070947 2 Assy. Outdoor Coil 12 Service Panel R01014070949 ALC 25CR R50024088731 13 Terminal Cover Panel R01014070838 A5LC 25/28CR R50024075147 14 Assy. Control Panel ALC 28CR A50024082133 ALC / A5LC 25CR R50044086136 3 Motor Bracket R01014070948 ALC 28CR R50044086139 4 Fan Motor A5LC 28CR R50044086140 ALC 25CR R03039028207 15 Top Panel R01014070596 A5LC 25CR R03039023391 16 Assy. Front Grille R50124072880 ALC / A5LC 28CR R03039024538 17 Plastic Handle, Side R12014057948 5 Fan Blade R03019023393 18 Assy. Valve Cover R50124073905 6 Valve Bracket 19 Assy.Cap Tube ALC 25/28CR A50014073890 ALC 25CR R50024088789 A5LC 25CR R50014078321 A5LC 25CR R50024081899 A5LC 28CR R50014080371 ALC 28CR A50024080186 7 Assy. Flare Valve 3 Ways 5/8" A5LC 28CR R50024080312 ALC 25/28CR R50054072863 20 Assy. 4 Way Valve A5LC 25/28CR R50059023336 ALC 25/28CR R50054077222 8 ALC 25/28CR A5LC 25/28CR R50059024520 Assy. Flare Valve 3 Ways 3/8" R50059022577 21 Partition R01014070951 A5LC 25CR 22 Plastic Handle, Front R12014070955 Assy. Flare Valve 2 Ways 1/4" R50059023334 Parts Not in Diagram A5LC 28CR Capacitor, Fan Motor Assy. Flare Valve 3 Ways 3/8" R50059024820 ALC /A5LC 25CR R04029026759 9 Back Panel, Right R01014070950 ALC /A5LC 28CR R04029026966 10 Compressor Capacitor, Compressor ALC 25CR A04019027570 ALC /A5LC 25CR, ALC 28CR R04029026779 A5LC 25CR R04019021361 A5LC 28CR R04029026778 ALC 28CR R04019012828 A5LC 28CR R04019020449


No Description Part No No Description Part No 1 Assy. Base Pan R50014053238 11 Bracket, Fan Motor R01014053232 2 Assy. Flare Valve 3/8" 12 Side Panel, Left R01010029899 ALC 30C/CR R50059000221 13 Fan Motor R03039004046 A5LC 35C/CR R50059017536 14 Fan Blade R03013028160 3 Assy. Flare Valve 5/8" 15 Assy. Front Panel R50014053236 ALC 30C/CR R50059000071 16 Plate, Flare Vlave R01013034235 A5LC 35C/CR R50059020805 Parts Not in Diagram 4 Panel, Partition R50014053277 Phase Sequencer R04089017029 5 Compressor High Pressure Switch ALC 30C/CR ALC 30C/CR R04109015136 220-240V/1PH/50Hz R50049013221 A5LC 35C/CR R04104061879 380-415V/3PH/50Hz R50049019889 Low Pressure Switch A5LC 35C/CR ALC 30C R04109015125 220-240V/1PH/50Hz R50049025547 A5LC 35C/CR R04109015400 380-415V/3PH/50Hz R50049025336 Assy. 4 Way Valve 6 Service Panel R01010029898 ALC 30CR R05029001991 7 Accumulator A5LC 35CR R50024087051 ALC 30C/CR R02119025988 Capacitor, Fan Motor R04029026761 A5LC 35C/CR R02119024262 Capacitor, Compressor 8 Back Panel, Right R01014053233 ALC 30C/CR R04029026779 9 Top Panel R01011029900 A5LC 35C R04029026782 10 Assy. Coil TXV R05019020252 ALC 30C A50024041851 ALC 30CR A50024035282 A5LC 35C/CR R50024082878



While upmost care is taken in ensuring that all details in the publication are correct at time of going to press, we are constantly striving for improvement and therefore reserve the rights to alter model specifications and equipment without prior notice. Details of specifications and equipment are also subject to change to suit local conditions and equirements and not all models are available in every market.
La signification des codes d'erreur affichés à l'écran et la façon de les effacer.
Problèmes fréquents, causes probables et solutions.
| Problème | Cause possible | Solution | |
|---|---|---|---|
| The air conditioner unit will not resume after power failure. | • The auto restart function is not functioning. Please turn on the unit with the wireless / wired controller. | p.109 | |
| The compressor does not operate 3 minutes after the air conditioner unit is started. | • Protection against frequent starting. • Wait for 3 or 4 minutes for the compressor to start operating by it self. | p.109 | |
| The airflow is too slow or room cannot be cooled sufficiently. | • The air filter is dirty. • The doors and windows are opened. • The air suction and discharge of both indoor and outdoor units are clogged or blocked. • The regulated temperature or temperature setting is not low enough. | p.109 | |
| Discharge airflow has bad odor. | • Cigarettes, smoke particles, perfume and others, which might have adhered onto the coil, may cause odor. • Contact your nearest dealer. | p.109 | |
| Condensation on the front air grille of the indoor unit. | • This is caused by air humidity after an extended period of operation. • The set temperature is too low. Increase the temperature setting and operate the unit at high fan speed. | p.109 | |
| Water flowing out from the air conditioner. | • Switch off the unit and contact your nearest dealer. This might be due to tilted installation. | p.109 | |
| Hissing airflow sound from the air conditioner unit during operation. | • Liquid refrigerant flowing into the evaporator coil. | p.109 | |
| The wireless controller display is dim. | • The batteries are discharged. • The batteries are not correctly inserted. • The assembly is not good. | p.109 | |
| Compressor operates continuously. | • Dirty air filter. Clean the air filter. • Temperature setting too low (cooling). Use higher temperature setting. • Temperature setting too high (heating), Use lower temperature setting. | p.109 | |
| No cool air comes out during cooling cycle, or no hot air comes out during heating cycle. | • Temperature setting too high (cooling). Use lower temperature setting. • Temperature setting too low (heating). Use higher temperature setting. | p.109 | |
| On heating cycle, warm air does not come out. | • Unit is in defrost mode. Heating operation will resume after defrost cycle ends. | p.109 |