In USA - BEST BY BROAN® P.O. Box 140, Hartford, WI 53027 In Canada - BEST BY BROAN® 550 Lemire Blvd., Drummondville, QC, J2C 7W9
V07693 rev. B

WARNING WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
know how to operate it. B. The fire is small and contained in the area
where it started. C. The fire department has been called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it will be cooled down. If the motor continues to shut off and restart, have the hood serviced. 4. For best capture of cooking impurities, the bottom of the hood should be at a minimum of 24” and at a maximum of 30” above the cooking surface. 5. Two installers are recommended because of the large size and weight of this hood. 6. To reduce the risk of fire and to properly exhaust air, be sure to duct air outside—Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage. 7. This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel. 8. To reduce the risk of fire and electric shock, the Best by Broan WP29M Series hood must be installed with Best by Broan interior blower models P6 or P12; Best by Broan exterior blower models EB6, EB9, EB12 or EB15; Best by Broan in-line blowers models ILB3, ILB6, ILB9, ILB11. Other blowers cannot be substituted. (Blowers sold separately.) 9. Please read specification label on product for further information and requirements.
a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambeing food (Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.

INTERIOR BLOWERS
Model 441 (10’’ Round wall cap)
(roof cap) Model 647 (7” Round wall cap)
Model 634 or 644

Model 427 (41/2” x 181/2” to 10” Round, 6” high - lateral
Model 423 (41/2” x 181/2” to 10” Round - vertical
Model 424 (41/2” x 181/2” to 10” Round - horiz. front/rear
Model 454 (41/2” x 181/2” to 10” Round -
Model 453 (41/2” x 181/2” to 10” Round -
MODEL P12 BLOWER/ROUGH-IN KIT (1200 cfm interior blower & rough-in plate)

IN-LINE AND EXTERIOR BLOWERS
Model 441 (10” Round wall cap)
Model ILB9 (800 cfm)

Model 421 (10” Round vert. in-line damper) Recommended for use with exterior blowers Model 410 (10” Round duct —2ft. sections)
In-line and exterior blower rough-in kit (included with EB6, EB9, EB12, EB15, ILB3, ILB6, ILB9 and ILB11 blowers.)

1.1 NON-DUCTED INSTALLATION For a non-ducted installation, we recommend using interior blower Best by Broan model P6 for effectiveness. (Blower sold separately.) The non-duct kit ANKWP Series (sold separately) must be installed. This kit fits hood from 30-inch width up to 48-inch width. See installation instructions included with the non-duct kit ANKWP Series.
1.2 DUCTED INSTALLATION For a ducted installation, either an interior or exterior blower or in-line blower may be used with this hood. The Best by Broan WP29M Series must be installed with blower models P6, P12, ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 only. Other blowers cannot be substituted. (Blowers sold separately.) Plan where and how the ductwork will be installed. If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 8, 11, 12, 14 and up of this manual. Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. Use metal duct tape to seal duct joints.


ROUND TRANSITION 4½" x 18½" to 10" (114 mm x 470 mm to 254 mm) (see page 3)
24" TO 30" (609 mm to 762 mm) ABOVE COOKING SURFACE
24" to 30" (609 mm to 762 mm) ABOVE COOKING SURFACE
24" to 30" (609 mm to 762 mm) ABOVE COOKING SURFACE
MODEL ILB3, ILB6, ILB9 OR ILB11 IN-LINE BLOWER TYPICAL DUCTWORK

Dimensions for the most common installation are shown beside. The minimum hood distance above cooktop must not be less than 24’’. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities. Distances over 30” are at the installer and users discretion.
Top of wood mounting strip A + 0.25’’ (6 mm)
A
non-duct kit flue
Hood
Minimum distance between
the hood and cooktop:
24’’ (610 mm)
Recommended maximum distance between the hood and cooktop: 30’’ (762 mm)
Standard 36” (914 mm)
HH0072A
high cooktop
MINIMUM AND MAXIMUM DISTANCE
OVER COOKTOP
3. PREPARE THE INSTALLATION
Remove the installation kit from inside the hood.
- Wood strip (screwed on back of hood) - Installation manual - Accessories including:
numbers. - Non-duct kit ANKWPD Series, mandatory for non-ducted installation. - Optional decorative flue AEWP Series, for ducted installation only. - Optional flat top cover ADPWP Series, for ducting through back of hood, intalled on hood or installed on the optional decorative
flue AEWP Series. Can also be installed on the non-duct kit flue ANKWPD Series.


Remove filters from hood and set aside. NOTE: It is recommended to start with the central one.
B. Remove tape on grease drip rail (1).
Lift out grease drip rail and set aside. NOTE: The 60-inch width hood has 2 grease drip

Using a Phillips no. 2 or Robertson no. 2 screwdriver, remove the screws retaining the pan (shaded part on illustration beside) to the hood. Remove the pan and set aside.

Measure and mark a level line on wall above cooktop location for the wood mounting strip (see illustration beside and under step 2). Remove wood mounting strip from back of hood. Use #10 - 2’’ flat head screws to secure the mounting strip to the drywall. Make sure to hit the wall studs.
7.1 DUCTED INSTALLATION: A) OPTIONAL DECORATIVE FLUE AEWP SERIES For a ducted installation, refer to the instructions sheet included with the optional decorative flue.
B) OPTIONAL FLAT TOP COVER ADPWP SERIES For ducting through back of hood only, install on hood or on the Optional Decorative Flue AEWP Series. Refer to the instructions sheet included with the optional flat top cover. 7.2 NON-DUCTED INSTALLATION: NON-DUCT KIT FLUE ANKWP SERIES Refer to the installation sheet included with the non-duct kit for details. NOTE: The Optional Flat Top Cover ADPWP Series can be installed on the Non-Duct Kit Flue ANKWP Series. Refer to
the instructions included with the optional flat top cover.

Rest the top back cavity of the hood on the wood mounting strip.
M OUNTING SCREWS LOCATION
Secure the hood to wood mounting strip with (4) screws #8 x 3/4” (for 30” and 36” width hoods) or (6) screws (for 42” width and wider hoods) provided at locations shown. Drill (2) 3/16’’ size holes into the drywall for wall anchors through the existing holes in the inside hood back in the locations shown. Then, install the two wall anchors with the remaining #8 x 3/4” screws and the (2) washers provided.
W ALL ANCHORS LOCATION
For a non-ducted installation, go to step 11, Install the Rough-in Plate.
9. SELECT BLOWER OPTION (EXTERIOR OR INTERIOR, DUCTED INSTALLATION)
INTERIOR BLOWER: Follow all subsequent steps of this manual.
EXTERIOR BLOWER: Refer to instructions packed with exterior blower and follow steps 11 and up of the present manual.

Model 423, 424, 427 453, or 454 Attach transition (if required) to blower rough-in plate. Use metal duct tape to make all joints secure and air-tight.
11.1 ALL INSTALLATIONS: Run power cable to installation location. Refer to the instructions included with the selected blower/rough-in kit (sold separately) for details on installing the rough-in plate. Install the rough-in plate so that the wiring box is located on the right side as you are facing the hood. 11.2 DUCTED INSTALLATIONS ONLY: For ducting through back of hood, remove existing plate from inside back of hood and attach it to inside top of hood to cover hole. Secure to threaded studs with same (4) nuts. For ducting through top of hood, existing plate remains in place on inside back of hood. Connect ducting to transition or rough-in plate as you are installing the rough-in plate. Use duct tape to make all joints secure and air-tight.
R OUGH - IN PLATE
ON TOP OF HOOD
L OCKNUTS
L OCKNUTS
P LATE ON BACK OF HOOD
HD0179
12.CONNECT THE WIRING (ALL INSTALLATIONS)

Remove wiring cover from rough-in plate and set aside. Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw. Reinstall wiring cover.


Once the blower is installed, plug the blower cord (A) into the female receptacle and the power supply cord (B) onto the male connector inside the hood.

Using a Phillips no. 2 or Robertson no. 2 screwdriver and the retaining screws, reinstall the pan (previously removed in step 6) inside the hood (shaded part on illustration beside).

Reinstall grease drip rail(s) (1). The illustration beside shows how to reinsert the grease drip rail(s) into the range hood.
Before reinstalling Evolutionary™ hybrid baffle filters, slide out the secondary micromesh filters from their back and remove all protective plastic film. 15.1 DUCTED INSTALLATION: Slide in the secondary filters into each baffle filters before reinstalling them on the hood. 15.2 NON-DUCTED INSTALLATION: Discard the secondary filters. Slide in the charcoal filters included in the non-duct kit. Reinstall the filters on the hood.
It is recommended to install side filters first and finish with center one(s). 1. Insert one end of Evolutionary™ hybrid baffle filter into the upper channel of the hood.

Replacement filters are available from your dealer. See label inside hood for size and part number.
For charcoal filter replacement kit, see table on page 12.

This hood must use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (included).
17.USE AND CARE
Evolutionary™ Hybrid Baffle Filters The Evolutionary™ hybrid baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Remove Evolutionary™ hybrid baffle filters by pushing them towards the back of hood and rotating filters downward. Slide out the secondary micromesh filter from the back of each hybrid baffle filter before cleaning. Baffle filters are dishwasher safe. Clean secondary filters with a warm detergent solution. Allow filters to dry completely before reinstalling them in the hood.
Grease Drip Rail The grease drip rail should be cleaned frequently. Lift it out from the hood and use a warm detergent solution. As for the baffle filters, wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Allow grease drip rail to dry completely before reinstalling it in the hood. Blower Cleaning Remove the filters in order to access the blower. Vacuum blower to clean. Do not immerse in water. Refer to blower instruction manual for more details. Hood Cleaning Stainless steel cleaning: How to maintain its “BRIGHT LOOK” Do:

Always turn ON your hood before you begin cooking in order to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
1. ON/OFF Blower switch 3. ON/OFF Halogen light switch 2. Blower speed control 4. Light intensity control Blower The blower is operated using two (2) controls. Use the ON/OFF switch (item 1 on picture above) to start and stop the blower. When turned on, the blower will operate at the previous setting of the speed control (item 2 on picture above). Turn the speed control knob counterclockwise to increase blower speed—clockwise to decrease speed. HEAT SENTRY This hood is equipped with a HEAT SENTRY thermostat. This thermostat is a device that will speed up the blower if it senses excessive heat above the cooking surface.
If blower is ON at a lower speed setting—it turns the blower up to HIGH speed. When the temperature level drops to normal, the blower will return to its original setting.
Cooktop Lighting (Halogen) The halogen lighting is controlled by two switches; one ON/OFF switch (item 3 on picture above) and one light intensity control switch. When turned on, the halogen bulbs will light cooktop at the previous setting of the light intensity control (item 4 on picture above). Turn the light intensity control knob counterclockwise to increase lighting—clockwise to decrease lighting. Use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (included).
BROAN ONE-YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states or provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to another. Any modification performed on this product without the authorization of Broan will void this warranty. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan at the address or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. Best by Broan®, P.O. Box 140, Hartford, WI 53027 USA (1-800-637-1453) Best by Broan®, 550 Lemire Blvd., Drummondville, QC J2C 7W9 CANADA (1-866-737-7770)


* NOT SHOWN.
WP29XX7 MODEL SAME PART NUMBERS, EXCEPT FOR ITEM 11 (SEE BELOW)



Aux États-Unis - BEST BY BROAN® P.O. Box 140, Hartford, WI 53027 USA Au Canada - BEST BY BROAN® 550 boul. Lemire, Drummondville, QC, J2C 7W9 CANADA
V07693 rév. B
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.