Manuel d'utilisation / d'entretien du produit M370078-01 II du fabricant Xantrex Technology
Aller à la page of 70
GPIB and Ethernet Interface for XG Series Pr ogr ammable DC P ower Supplies Oper ating Manual GPIB ENET www .programmablepower .com.
.
XG 850 Watt Series Programmable DC Power Supply Operating Manual.
M370078-01 ii About Xantrex Xantrex T echnology Inc. is a world-lea ding supp lier of advanced power electr onics and controls with products from small mobile units to util ity-scale systems for wind, solar, batteries, fuel cells, microturbines, and backup power applicati ons in both grid-connected and stand-alon e systems.
M370078-01 iii Product Numbers (FGAs) P art Numbers for Rack Mount Kits Contact Information XG6-1 10 XG60-14 XG8-100 XG80-10.5 XG12-70 XG100-8.5 XG20-42 XG150-5.
.
M370078-06 v About This Manual Purpose This Operating Manual provides explanations and procedures for programming the XG 850 W att Series Programmable DC Power Supply from the GPIB interface and connectin g and configuring th e power supply to the Ethernet.
About T his Manual vi M370078-06 Conventions Used The following conventions ar e used in this Manual. Related Information For related materials on this product, see also: • XG 850 W att Series Programmabl e DC Power Supply Operating Manual (Part number: M37007 8-01).
M370078-06 vii Important Safety Instructions W ARNING: High Ener gy and High V oltag e Exercise caution when using a power supply . High energy levels can be stored at the output voltage termin als on a power supply in normal operatio n.
viii.
M370046-06 ix Important Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - vii 1 GPIB Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - .
x.
M370046-06 xi Figure 1-1 GPIB Connector and Pins - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–2 Figure 1-2 Scanning for Instruments - - - - - - - - - - - - - - - - - - - - - -.
F igures xii M370046-06 Figure 2-29 Saved Session - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–25 Figure 2-30 Multiple Power Supplies and Two Comput ers - - - .
M370046-06 xiii Table 1-1 GPIB Pin Description (J2) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–3 Table 2-1 Description of PIN on RJ-45 Plug - - - - - - - - - - - - - - - - -.
xiv.
1 GPIB Chapter 1, “GPIB” provides in formation and procedures on programming the XG 850 W att Series Programmable DC Power Supply from the GPIB (General Purpose Interface Bus) interface.
GPIB 1-2 M370078-06 Overview The power supply can b e programmed from a remote terminal using a GPIB interface. Communication over the GPIB interface meets IEEE 488.2 standards and are Standa rd Commands for Programmable Instrumentation (SCPI) compliant.
Overview M370078-06 1-3 T able 1-1 identifies the pin name and describes the pin functions. T able 1-1 GPIB Pin Desc ription (J2) Pin # Name Function Note 1D I O 1 D I O 1 D a t a 2D I O 2 D I O 2 D a.
GPIB 1-4 M370078-06 Communication with Y our Device This section provides information on selecting the GPIB interface as the communication port used on the XG , and it also provides an example of how commands can be sent and receiv ed. The details of the IEEE 488.
Communication with Y our Device M370078-06 1-5 : 7. In the righ t window , click on Instrument1 and review the dev ice properties. See Figure 1-3. Figure 1-2 Scanning for Instruments.
GPIB 1-6 M370078-06 8. Click Communicate with Instrument in the GPIB Explorer toolbar . See Figure 1-3. NI-488.2 Communicator appears. See Figure 1-4. Figure 1-3 Instrument Proper ties Figure 1-4 ID S.
Communication with Y our Device M370078-06 1-7 9. In the Send String box, enter *IDN? and cl ick Query . 10. The String Received window will show the ID string for the XG . The ID string indicates the model, serial number , firmware version as well as the GPIB card firmware vers ion.
1-8.
2 Ethernet (ENET) Chapter 2, “Ethernet (ENET) ” provides information and procedures to connect and configure the power supply to the ENET ..
Ethernet (ENET) 2-2 M370078-06 Overview This chapter is intended for network administrators responsible for the configuration and maintena nce of devices on the netwo rk. This chapter provides information for connecting an d configuring the power su pply to Ethernet.
Basic Section M370078-06 2-3 Figure 2-2 P ower Supply Plug Figure 2-3 RJ-45 Plug T able 2-1 Description of PIN on RJ-45 Plug Pin# Name Description 1 TX+ T ransmit data + 2 TX– T ransmit data – 3 R.
Ethernet (ENET) 2-4 M370078-06 ENET Connector The XPort® ENET connecto r is located on the rear panel of the power supply . See Figure 2-5. XP ort™ LEDs The device contains two bi-color LEDs built into the front of the XPort™ connector . See Figure 2-5.
Basic Section M370078-06 2-5 Network T opology and Connection The following section describes the ne twork topology for the single computer and sin gle XG power supply unit. Th e other possible network topologies will be disc ussed later in the “Advanced Section” on page 2– 26.
Ethernet (ENET) 2-6 M370078-06 Setting Up the Computer T o set up the computer: 1. Open Explorer on the main computer , go to Contr ol Panel > Network Connections > Local Ar ea connections. See Figure 2-7. 2. Right click on the mouse button and click on Properties.
Basic Section M370078-06 2-7 3. Click the Inte rnet Protocol (TCP/IP) check box and click Properties . See Figure 2-8. The Internet Protocol (TCP/IP) Pr operties Dialog Box appears.
Ethernet (ENET) 2-8 M370078-06 4. Click on Use the following IP address option and type the appropriate IP ad dress in the box, or select the Obtain an IP addr ess automatically setting if your network is configured using DHCP .
Basic Section M370078-06 2-9 Software Installations T o set up the ENET option card, the Lantronix® DeviceInsta ller program needs to be installed on your PC. De viceInstaller is an all-in-one utility for setting up various Lantronix devices on a network.
Ethernet (ENET) 2-10 M370078-06 3. Click Next to begin the installation. The Installation Complete window displays when the installation is finished. 6.
Configuring the Device Using DeviceInstaller M370078-06 2-11 Configuring the Device Using DeviceInstaller The DeviceInstaller displays a list of the XG units with the ENE T option that are on the network. When the DeviceInstaller initially starts, the device list is empty .
Ethernet (ENET) 2-12 M370078-06 Assigning an IP Address to the P ower Supply Unit If your system is auto-IP configured , the following warning message is displayed: T o assign an IP address to the power supply unit: 1. Click OK to dismiss the Auto-IP warn ing me ssage.
Configuring the Device Using DeviceInstaller M370078-06 2-13 2. Click Search to get a list of all the XG devices that can be reached from the network adaptor that you previously selected. If your XG unit (s) are powered up, the y should appear in this list.
Ethernet (ENET) 2-14 M370078-06 5. In this window , click the W eb Configuration tab, which will open a new window . See Figure 2-17. Figure 2-16 IP Address Details Window Important: Do NOT use the Assign IP button in the tool bar , upper left of this window .
Configuring the Device Using DeviceInstaller M370078-06 2-15 6. Next to the Address field, click the green Go button. 7. Y ou will be prompted for user name and password : ignore these fields (leave blank) and click OK . This brings up the Lantronix XP ort® interface (Figure 2-18).
Ethernet (ENET) 2-16 M370078-06 8. At the top of the sidebar menu click Network.See Fig ure 2-19. Figure 2-18 Lantronix XP ort® Interface.
Configuring the Device Using DeviceInstaller M370078-06 2-17 9. In the IP Configuration section, cl ick the radio button next to “Use the following IP configuration.
Ethernet (ENET) 2-18 M370078-06 2. Turn the rotary Adjust/Enter control to select the LAn communication port. 3. Press the rotary Adjust/Enter control. ADDR is display ed on the output voltage display . 4. Turn the rotary Adjust/Enter control to select the desired address between 1 to 30.
T erminal Configuration M370078-06 2-19 T erminal Configur ation The terminal program a llows for communication with the power supply . T o use a terminal program, set it up using the parameters from the following sections. If you wish to u se HyperT erminal, see “Setting Up a HyperT erminal Connection” for instructions.
Ethernet (ENET) 2-20 M370078-06 2. Click New to create a new connection. The Connection Descri ption window appears. See Figure 2-21. 3. Enter the na me of the connection and select the icon. 4. Click OK . The new connection setup dialog box will appear .
T erminal Configuration M370078-06 2-21 5. In the Connect using: box, select “TCP/IP (Winsock)”. 6. In the Host address box, enter the IP address, obtained in step 14 of the section entitled “Assigning an IP Address to the Power Supply Unit” on page 2–12 .
Ethernet (ENET) 2-22 M370078-06 The XG-ENET Propert ies dialog box appe ars. See Figure 2-25 . Figure 2-24 ENET Properties Window Figure 2-25 XG-ENET Properties Dialog Box.
T erminal Configuration M370078-06 2-23 3. Click the ASCII Setup button. The ASCII Setup dialog box will appear as shown in Figure 2-26. 4. V erify that the ASCII Sending and ASCII Receiving boxes are checked as shown in Figure 2-26.
Ethernet (ENET) 2-24 M370078-06 Figure 2-27 Main HyperT erminal Window Figure 2-28 Saving Session.
T erminal Configuration M370078-06 2-25 5. T ype the name of the session. It is recommended that you include the IP in your naming conv ention so that it is clear which XG you are connecting to. 6. Click Save . Congratulations! Y our network is in stalled and functioning p roperly .
Ethernet (ENET) 2-26 M370078-06 Advanced Section The advanced section describes the setup and connection for various network topologies involv ing multiple power supplies. Network T opology 1: Simple LAN The simple LAN topology is the mo st common configuration for setting up the ENET option on the XG .
Advanced Section M370078-06 2-27 T o set up for multiple power supplies and two computers: 1. Set up your computer as described in “Setting Up the Computer” on page 2–6. Repeat the procedure for each computer hooked up to the system. 2. Install the DeviceInsta ller software on the PC you wish to use to configure the XG unit (s) with.
Ethernet (ENET) 2-28 M370078-06 There are two HyperT erminal windows for controlling two power supply units. See Figure 2-31. Figure 2-31 HyperT erminal Session.
Advanced Section M370078-06 2-29 Figure 2-32 shows a system with two connected devices. Figure 2-32 System with T wo Connected Devices Important: In this system configuration, every power supply needs a unique IP address, whereas the address defined from front panel (power supply ’ s own address) may be arbitrary .
Ethernet (ENET) 2-30 M370078-06 Network T o pology 2: ENET and RS-485 Bus Up to 30 units may be connected to the RS-485 bus. The first unit connects to the controller via ENET , and the other units are connected with the RS-485 bus. Figure 2-33 shows the system of an XG unit with the ENET option and several XG units connected via the RS -485 bus.
Advanced Section M370078-06 2-31 Figure 2-34 shows the HyperT erminal session for the combined configuration which i s an ENET and RS-485 network. This figure also shows access to power supplies #2 and #10 sequentia lly . Setting Up Y our System T o set up your system: 1.
2-32 5. Config ure the master power s upply which is the unit with the ENET option (power supply #1 in Figure 2-33) by follo wing the instructions in “Selecting ENET as the Communication Port” on page 2–17. 6. The follow ing Steps 7, 8 and 9 must be repeated for each slave unit.
Advanced Section M370078-06 2-33.
Ethernet (ENET) 2-34 M370078-06.
A T r oubleshooting Appendix A, “T roubleshooting” provides troubleshooting information for the combined ENET and RS-485 communication and for ENET communication.
T roubleshooting A-2 M370078-06 T r oubleshooting for ENET – RS-485 Communication This section describes specific tr oubleshooting for the combined ENET – RS-485 communicat ion only . See “T roubleshooting for ENET Communication” on page A–3 for typical troubleshooting procedures for connecting and setting up ENET communications.
M370078-06 A-3 T r oubleshooting for ENET Communication This section describes typical troubles hooting for connectin g and setting up the ENET communication. T able A-2 T r oubleshooting for ENET Communication Symptom Check Action DeviceInstaller does not detect your device.
T roubleshooting A-4 M370078-06 The power suppl y is not responding. The communication port on the power supply unit is not selected properly . The address of the power supply unit is not val id. The address has not been selected using the *ADR <address> .
B Links Appendix B, “Links” provides the W eb site links for relevant third party vendors..
Links B-2 M370078-06 Links Lantronix, Inc. W eb site www .lantronix .com/index.html XPort™ Embedded D evice Server www .lantronix.com/products/ eds/xport/ index. html DeviceInstaller http://www .lantronix.com/ device- networking/utilities-to ols/device- installer .
M370078-01 WA-1 W arr anty and Product Information Wa r r a n t y What does this warranty cover? This Limit ed W a rranty is provided by Xantrex T echnology In c. ("Xantrex") and covers defects in workm anship and materials in your XG 850 W att Series Programmable DC Power Supply.
W arranty and Return WA-2 M370078-01 What proof of pur chas e is requir e d? In any warranty claim, da ted proof of purchase must accompany the product and th e product must not have been disass embled or modifi ed without prior written authorization by Xantrex.
W arranty and Return M370078-01 WA-3 Exclusions If this product is a consumer product, federal law do es not allow an exclusion of implied warranties. T o the extent you are entitled to i mplied warranties un der federal law , to the extent permitted by applicable law they are limited to the duration of this Limited W arranty .
W arranty and Return WA-4 M370078-01 Return Procedur e 1. Package the unit safely , preferably using the original box and packi ng materials. Please ensure that your product is ship ped fully insured in t he original packaging or equivalent. This warrant y will not apply where the product is damaged due to improper packaging.
.
Xantrex Technology Inc. 1 800 733 5427 (toll free North America) 1 858 450 0085 (direct) 1 858 458 0267 (direct) sales @programmablepower .com service@programmablepower .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Xantrex Technology M370078-01 II c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Xantrex Technology M370078-01 II - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Xantrex Technology M370078-01 II, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Xantrex Technology M370078-01 II va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Xantrex Technology M370078-01 II, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Xantrex Technology M370078-01 II.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Xantrex Technology M370078-01 II. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Xantrex Technology M370078-01 II ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.