User’s Guide Value Series Model VS375C, VS575C.
For your records The serial number of your UPS is on the rear panel. You should note the serial number in the space provided below. Retain this booklet as a permanent record of your purchase to aid in identification in the ev ent of theft or loss. Model No: Serial No.
LIMITED WARRANTY What the warranty covers: We warrant this product to be free from defec ts in material and workmanship during the warranty period. If a product proves to be defecti ve in material or workmanship during the warranty period, we w ill at our sole option r epair or replace the product with a like product.
Limitation of implied warranties: THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, WHICH EXTEND BEYOND THE DESCRIPTION CONTAINED HEREIN INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Exclusion of damages: OUR LIABILITY IS LIMITED TO THE COST OF REPAIR OR REPLACEMENT OF THE PRODUCT.
Life Support: We do not recommend the use of our UPS produc ts for life support equipment or direct care where failure of a UPS product could cause failu re of, or diminished effectiveness of the life support equipment or patient care.
.
VS375C/VS575C 1 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS ! THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS. KEEP THIS MANUAL HANDY FOR REFERENCE. ♦ CAUTION: A BATTERY CAN PRESENT A RISK OF ELECTRICAL SHOCK, BURNS FROM HIGH SHORT-CIRCUIT CURRENT, FIRE OR EXPLOSION FROM VENTED GASES.
2 VS375C/VS575C ♦ CAUTION: ! THE UPS CONTAINS VOLTAGES WHICH ARE POTENTIALLY HAZARDOUS. ALL REPAIRS SHOULD BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. THE UPS HAS ITS OWN INTERNAL ENERGY SOURCE (BATTERY). THE OUTPUT RECEPTACLES MAY BE LIVE EVEN WHEN THE UPS IS NOT CONNECTED TO AN AC SUPPLY.
VS375C/VS575C 3 FEDERAL COMMUNICATIONS COMMISSION (FCC) WARNING: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protecti on against harmful interference in a residential installation.
4 VS375C/VS575C TABLE OF CONTENTS 1. INTRODUCTION 1.1 Overview 5 1.2 Frequency Auto-Selection 5 1.3 User Replaceable Battery Design 5 1.4 Over Voltage and Under Voltage Protection 6 1.5 Schedule Shutdown & Startup 6 1.6 Data-Line Surge Protection 6 2.
VS375C/VS575C 5 1. INTRODUCTION 1.1 Overview The Value Series of Uninterruptible Power Systems ( UPS ) was designed to prevent spikes, transients and blackouts from reac hing your sensitive equipment. Your equipment may include such items as comput ers and computerized instruments to telecommunication systems.
6 VS375C/VS575C 1.4 Over Voltag e an d Under Voltage Protectio n The UPS will switch to backup mode and provide the power from its internal battery w hen the input line voltage is too low or too high.
VS375C/VS575C 7 2. UPS CONTROLS 2.1 External Views 2.2 Power On/Off/Test/Silence Button: The On/Off/Test/Silence Butt on has four functions: 1. When the UPS is off and AC power is present, press this button for more than 3 seconds to turn on the UPS. The UPS can be turned on even when AC power is not present.
8 VS375C/VS575C AC Mode When this Green LED is lit, the UPS is in normal mode, and providing power to your equipment. The UPS will continue to filter and provide surge protection. Battery Mode When this Yellow LED is lit, the UPS is providing pow er from its battery.
VS375C/VS575C 9 3. INSTALLATION AND OPERATION Before installation, please read and understand the following instructions: 3.1 Unpacking and Insp ectio n Examine the packing carton for damage and accessory in the box. Notify the carrier immediately if damage is observed.
10 VS375C/VS575C View So nic G8 10 120V 2.7A 50 / 60 Hz SN: Q771515388 Computer Co Pent ium Pro 200MHz 120V 2.0A 50/60 Hz SN: 123456 3. Multiply the voltage and current of each piece of equipment ( VA requirements ); for example, 120V x 2.7A = 324VA, 120V x 2.
VS375C/VS575C 11 3.5 Connecting Your Equipment to the UPS 1. For all UPS models except the 2x0V ve rsions: connect the power cord(s) of your computer equipment to the output receptacle(s) of the UPS.
12 VS375C/VS575C Note: Backup all unsaved files before you perform the following functional test. 3. To test the backup function, you may unplug the pow er cord of the UPS. During this test, observe that your equipment operates properly and w ithout interruption.
VS375C/VS575C 13 4. SPECIFICATIONS 4.1 Electrical Specifications Product Name Frequency (Hz) Voltage (V) Capacity VA / W 100 / 110 / 120 VS375C 50/60 220 / 230 / 240 375VA / 225W 100 / 110 / 120 VS575.
14 VS375C/VS575C Audible A larm: Battery discharge at power failure Beep every 4 seconds Battery approaches final discharge Beep every second Overload Continuous buzzer 4.2 Mechanical Sp ecificatio ns: Product Name Dimensions Weight (Kg) W × D × H ( mm ) Net Gross VS375C 200*77*175 2.
VS375C/VS575C 15 5. TROUBLESHOOTING If the UPS fails to operate properly, please review the following steps before calling the repair center: 1. Is the UPS plugged into a proper working outlet? 2. Is the line voltage within the rating specified? 3. Does the circuit breaker on the rear panel need to be reset? 5.
16 VS375C/VS575C 6. USER REPLACEABLE BATTERY The Batteries inside your UPS should last fr om between 3 to 5 years. If you suspect that the batteries are weak, allow the UPS to c harge the batteries for at least six hours and then test the backup time.
VS375C/VS575C 17 6.2 Battery Replacemen t Pro cedure for VS375C/ VS575C Changing the batteries in your UPS is a sa fe and easy procedure. Since the battery is isolated from the AC input you may leave your UPS and computer or other equipment on during the following procedure.
18 VS375C/VS575C Fuse Replacement Procedure 1. Use a slotted screwdriver to take out the fuse socket. 2. Take out the broken fuse from the fuse socket. 3. Throw away the broken fuse. 4. Use the slotted screwdriver to push out the spare fuse. 5.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté ViewSonic VS575C c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du ViewSonic VS575C - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation ViewSonic VS575C, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le ViewSonic VS575C va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le ViewSonic VS575C, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du ViewSonic VS575C.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le ViewSonic VS575C. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei ViewSonic VS575C ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.