647 BFC cover 8/18/00 djt BFC Balance Flue (Closed Combustion) Heat-Circulating Fireplace Model: BFC36 For use in the U.S. / Canada Underwriter ’s Laboratories Report No.
2 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Safety Information Please Read This Manual Before Installing and Using Fireplace IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instruc- tions may result in a possible fire hazard and will void the warranty .
3 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 BFC36 Balanced Flue Heat-Circulating Fireplace Fig. 1 BFC36 specifications and framing. " (16mm) " (13mm) .
4 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 FP554a BFC Fireplace and chase parts identification circulating model 8/21/00 djt T ermination Cap Storm Collar Pan Flashing Draftstop Standoff .
5 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 D Rise B G H B Offset C E 6 FT . G H A Hearth Floor Chimney Section CHIMNEY FLUE EXIT Elbow FP269 MBUF 5/16/96 rev . 5/25 TCS8A Support Example 1 Example 2 Example 3 Chimney Requirements - Offset Installations Notes: G + H cannot exceed 20 feet.
6 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Planning Information Preplanning an installation is very important to ensure safety and to save time and money . An installer must predetermine where a fireplace will be set and how the chimney system will be run.
7 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30’ (9m) above the hearth. Chimney supports are required if the vertical height exceeds 30’ (9m).
8 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 FPC555a Platform insulation BFC model 8/21/00 djt Hard Flat Surface Insulation Platform FPC555a Fig.
9 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Offset Installation In order to clear an obstruction, it may be necessary to offset chimney from vertical. This is accomplished by using elbows. Use the 30° Offset Elbow table on Page 5 to determine proper offset and parts required.
10 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Positioning, Safety Strips, Securing the Fireplace Slide fireplace into position. Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1 ¹⁄₂ ” (38mm), al- lowing the remainder to extend in front of firebox.
1 1 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 14. When you get a good lock, you will hear the pipe clearly snap together .
12 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Firestop spacers are not available for , nor are they required on vertical walls. DO NOT put any sealant around the area where the outer pipe slides through the firestop spacer . If you seal this area, it may cause a fire hazard.
13 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 FRONT VIEW SIDE VIEW Air Space Clearances FPC559a BFC AIR SP ACES circulating models 8/21/00 djt Standoff Combustible framing material MUST NOT penetrate AIR SP ACE (shaded areas).
14 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 MA81 rev. 8/5/97 1 ¹⁄₂ " Ref. B C Combustible materials are permitted within a shaded area shown in Figure 21 titled Minimum W all Clearances. * * * MA81 Fig. 20 Combustible mantel clearances.
15 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Side W all Protection Adjacent combustible side walls that are within mini- mum dimensions shown in Figure 24 of the fireplace opening must be protected with CFM Corporation W all Shield Model SP40 or a specifically built wall shield described in Figure 18.
16 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 W ARNING: Hearth extension must be installed in accordance with Figure 23 and must not cover the bottom front opening of the circulating model.
17 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Finish Glass Doors The fallaway handles are used to open and close the front doors. The fallaway handles may be removed after each use or may be left in place. CAUTION: If the handles are left in place during operation, they may become hot.
18 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Install 1/2” (13mm) certified gas pipe through opening. After gas pipe installation is complete, use insulation that was removed from gas line tube to repack space around the pipe.
19 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 647 BFC parts 8/24/00 djt 1 2 3 5 6 7 8 9 10 1 1 12 13 14 16 15 19 18 17 � 24 25, 26 20 21, 22, 23 27 27 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
20 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 BFC Balanced Flue Fireplace (continued) 25. Stud 3/8-16 x 1 ⁵⁄₈ ” 20009776 26. Nut Hex Jam 3/8-16 T oplk 1203290 27.
21 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 The following accessories for this appliance are available from your local V ermont Castings, Majestic Products dis- tributor . Should you need additional information beyond what your distributor can furnish, contact: CFM Corporation, 2695 Meadowvale Blvd.
22 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Chimney Components Component Description Model Number Chimney Support Used to support chimney for each of TCS8A 30’ vertical height and 6’ .
23 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 LIMITED W ARRANTY & 30 YEAR PROTECTION PLAN For MAJESTIC FIREPLACES ® PRE-ENGINEERED Fireplace Systems CFM Corporation warrants its Pre-En.
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vermont Castings BFC36 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vermont Castings BFC36 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vermont Castings BFC36, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vermont Castings BFC36 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vermont Castings BFC36, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vermont Castings BFC36.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vermont Castings BFC36. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vermont Castings BFC36 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.