Manuel d'utilisation / d'entretien du produit BHDT36 du fabricant Vermont Casting
Aller à la page of 34
- 1 - INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER 10001827 11/01 Rev.1 Direct V ent T op V ent Model BHDT36 DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance.
- 2 - T ABLE OF CONTENTS PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase. IMPORTANT: R ead all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
- 3 - IMPORTANT: PLEASE REVIEW THE FOLLOWING CAREFULLY Remove any plastic from trim parts before turning the fireplace ON. It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle.
- 4 - A 36" 914mm B 34 1/4" 870mm C 21" 533mm D 33" 838mm E 24" 610mm F 16" 406mm G 37 1/4" 946mm I7 1/8" 181mm J6 3/4" 171mm K 10" 254mm L 13 1/2&quo.
- 5 - Ref. Mantel Ref. Mantel From Mantel Leg from Depth Top Louvre Fireplace Side V 10" (254 mm) A 12" (305 mm) 10" (254mm) W 8" (203 mm) B 10" (254 mm) 8" (203mm) X 6&q.
- 6 - Do not use this fireplace if any part of it has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control which has been under water.
- 7 - P I L O T TPTH TP TH SIT VALVE REMOTE SWITCH INSTALLATION 1. Thread wire through the electrical knockout located on either side of fireplace.. Do not cut wire or insulation on metal edges. Ensure that wire is protected. Run the other end to a conveniently located wall receptacle box.
- 8 - V V V V V V V V V X X X D E B B B C B M B A J K A F L G G TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) H I Fixed Closed Fixed Closed Openable Openable Fixed Closed G G N N Your fireplace is approved to be vented either through the side wall, or vertical through the roof.
- 9 - Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. A = Combustible 6"(152mm) Noncombustible 2"(50mm.
- 10 - For some installations, it may be desireable to have some amount of the horizontal vent run immediately after the fireplace. A verti- cal rise must be used but can be located anywhere in the vent system, to meet the perimeters identified in the venting graph.
- 11 - If a 90 degree elbow is used in the horizon- tal vent run (level height maintained) the maximum horizontal vent length is reduced by 36 inches. Fig. 15. This does not apply if the 90 degree elbows are used to increase or redirect a vertical rise.
- 12 - COMBUSTIBLE WALLS (Fig. 18): Cut a 9-3/8"H x 9-3/8"W (240 mm x 240 mm) hole through the exterior wall and frame as shown. NON-COMBUSTIBLE WALLS (Fig.
- 13 - Sealing vent pipe and firestop gaps with hi- temperature sealant will restrict cold air being drawn in around fireplace. STEP 5 (Fig. 23) Use the appropriate length of pipe section – telescopic or fixed – and install.
- 14 - DO NOT BACK FILL AROUND SNORKEL. SOIL SHOULD NOT BE LESS THAN 4" (100mm) BELOW SNORKEL. FOUNDATION RECESS SNORKEL SCREWS WALL SCREWS SHEET METAL WATERTIGHT SEAL AROUND PIPE If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel.
- 15 - TYPICAL STRAIGHT-UP INSTALLATION 40 FEET (12.2m) ATTIC INSULATION SHIELD JOISTS ROOF VENT TERMINATION ATTIC INSULATION ROOF SUPPORT STORM COLLAR ROOF FLASHING 2' Min. CEILING JOISTS Fig. 33 1. Locate your fireplace. 2. Plumb to centre of the (4") collar from ceiling above and mark position.
- 16 - CRIMPED ENDS VENTING COMPONENTS Starter Kit -Model 7DVSK - Sidewall Venting Starter Kit - Model 7DVSKV - Vertical Venting for 7DVSKV-A order 1/12 to 6/12 roof pitch for 7DVSKV-B order 7/12 to 1.
- 17 - GENERAL INFORMA TION ON ASSEMBLING THE TWIST LOCK VENT PIPES When using CFM Majestic twist lock pipe it is not neces- sary to use silicone to seal the twist lock joints. The only areas that need silicone are the collars on the fireplace, the telescoping pipe (if used) and the horizontal termina- tion connection (when necessary).
- 18 - The maximum number of 90 degree elbows per side wall installation is three (3). The maximum number of 45 degree elbows permitted per side wall installation is two (2).
- 19 - HOW TO USE THE VENT GRAPH 1. Determine the height of the centre of the horizontal vent pipe exiting through the outer wall. Using this dimension on the Sidewall Vent Graph (Fig. 39), locate the point it intersects with the slanted graph line. 2.
- 20 - Fig.44 Fig. 42 #8 SCREWS(2) ADJUSTABLE ZERO CLEARANCE SLEEVE ADJUSTABLE ZERO CLEARANCE SLEEVE #8 SCREWS(2) #8 SCREWS(2) Maximum Length 12" (294mm) FIRESTOP Fig. 43 STEP 4 (Fig. 44) Measure the horizontal length requirement including a 2" (50mm)overlap, i.
- 21 - STEP 7 Support the horizontal pipes every 36 inches (914mm) with metal pipe straps. Make sure that the horizontal vent pipe is installed on a level horizontal plane. STEP 8 Recheck the fireplace to make sure that it is levelled, properly positioned, and nailed or screwed to the floor.
- 22 - TYPICAL STRAIGHT-UP INSTALLATION 40 FEET (12.2m) ATTIC INSULATION SHIELD JOISTS ROOF VENT TERMINATION ATTIC INSULATION ROOF SUPPORT STORM COLLAR ROOF FLASHING 2' Min.
- 23 - 1. Locate your fireplace. 2. Plumb to centre of the (4") collar from ceiling above and mark position. 3. Cut opening equal to 9-3/8" x 9-3/8" (240 mm x 240 mm). 4. Proceed to plumb for additional openings through the roof. In all cases, the opening must provide a minimum of 1 inch clearance to the vent pipe, i.
- 24 - TWIST LOCK VENTING COMPONENTS Starter Kit -Model 7TDVSK - Sidewall Venting Starter Kit - Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to.
- 25 - GLASS FRAME REMOVAL 1. Shut off gas. 2. Let the fireplace cool if it has been operating. 3. Remove top louvre. (See Louvre Removal) 4. Open the lower louvre assembly. 5. Release the two clamps at the bottom of the window frame by pulling down on the clamp handles.
- 26 - HI OFF PILOT LO LAVA ROCK The lava rock provided with this fireplace must be placed on the firebox base on either side of the burner assem- bly. Under no circumstances should this lava rock be placed on any part of the burner assembly. INSTALLATION OF LOGS Fig.
- 27 - The burner and control system consists of: • burner tube • gas orifices • pilot assembly • thermopile • millivolt gas valve Most of these components may require only an occasional checkup and cleaning and some may require adjustment. If repair is necessary, it should be performed by a qualified technician.
- 28 - 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears.
- 29 - • GAS SUPPLY ON • SUPPLY LINE HOOKED UP • SHUTOFF VALVE OPEN NO NO NO NO • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN. • FOR SPARK AT ELECTRODE WHILE DEPRESSING PIEZO — 1/8" GAP TO PILOT HOOD NEEDED. • ALL WIRING CONNECTIONS • REPLACE PIEZO IGNITOR • FOR AIR IN THE LINES • THERMOPILE NEEDS A MINIMUM 325mV.
- 30 - TROUBLE SHOOTING THE GAS CONTROL SYSTEM SIT 820 NOV A MILLIVOL T V AL VE START CHECK GLASS DOOR TO BE REMOVED BEFORE SERVICE WORK GAS SUPPLY ON • SHUTOFF VALVE OPEN • CONFIRM GAS HOOK-UP LIGHT PILOT WITH PIEZO IGNITION • ELECTRODE GAP MIN.
- 31 - REPLACEMENT P ARTS LIST D ESCRIPTION BHDR36 1. Log Set Complete 10001818 1a. Log Front BH1 1b. Log Rear BH2 1c. Log Top Left BH3 1d. Log Top Right BH4 2. Lava Rock (Package) 10001454 3. Burner Tube Assembly 10001811 4a. Orifice Burner (Nat) SEE RATING PLATE FOR ORIFICE SIZE 4b.
- 32 - REPLACEMENT P ARTS 27 26 24 25 22 4 a/b 17 31 32 33 30 30 29 21 23 19 a/b 5 a/b 34 2 28 36 31 12 L O H I PILOT ADJ PILOT ON OFF 20 a/b 18 8 a/b 3 6 a/b 16 11 9 15 13 7 a/b 10 15 14 #1 - COMPLET.
- 33 - 1. Slide fan assembly from the left side into fireplace opening, line up mounting holes with screw studs on back of fireplace and fasten with #10-24 hex nuts.
- 34 - OPTIONAL CERAMIC REFRACTORY INSTALLATION 6. Hang Bay Window Frame assembly over existing glass frame. Do not remove existing glass frame 7. Re-install top louvre assembly.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vermont Casting BHDT36 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vermont Casting BHDT36 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vermont Casting BHDT36, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vermont Casting BHDT36 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vermont Casting BHDT36, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vermont Casting BHDT36.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vermont Casting BHDT36. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vermont Casting BHDT36 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.