Manuel d'utilisation / d'entretien du produit VMH26TPB du fabricant Vanguard
Aller à la page of 36
Save this manual for future reference. O WNER’S OPERA TION AND INST ALLA TION MANU AL VENT -FREE PR OP ANE/LP GAS COMP A CT CLASSIC HEAR TH FIREPLA CE ® 14,000 to 26,000 Btu/Hr with Thermostat .
2 102886 CONTENTS SECTION PAGE Safety Information continues on next page Safety Information ................................................................................... 2 Product Identification ..................................................
3 102886 SAFETY INFORMA TION Continued WARNING ICON G 001 W ARNINGS Continued WARNING: Any change to this fireplace or its controls can be dangerous. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
4 102886 PR ODUCT IDENTIFICA TION LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
5 102886 ASSEMBL Y ASSEMBLING FIREPLACE Tools Required: Phillips screwdriver, 5/16" hex wrench, and slotted screwdriver Installing Log 1. Remove back log, branch, and hood from log box. Discard protective packaging. 2. Remove two shipping screws above screen (see Figure 2).
6 102886 AIR FOR COMBUSTION AND VENTILA TION WARNING ICON G 001 W ARNING This heater shall not be installed in a confined space unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
7 102886 AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
8 102886 AIR FOR COMBUSTION AND VENTILA TION Continued Figure 4 - Ventilation Air from Inside Building Shown with Optional Mantel WARNING ICON G 001 W ARNING If the area in which the heater may be ope.
9 102886 AIR FOR COMBUSTION AND VENTILA TION Continued Figure 5 - Ventilation Air from Outdoors Shown with Optional Mantel Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor.
10 102886 INST ALLA TION CHECK GAS TYPE Use only propane/LP gas. If your gas supply is not propane/LP, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace. INSTALLATION ITEMS Before installing fireplace, make sure you have the items listed below.
11 102886 Figure 7 - Mounting Clearances As Viewed From Front of Fireplace Shown with Optional Mantel WARNING ICON G 001 CA UTION If you install the fireplace in a home garage • fireplace pilot and burner must be at least 18 inches above floor. • locate fireplace where moving vehicle will not hit it.
12 102886 INST ALLING Continued 36 5/8" 25 7/8" 51 3/4" 26 7/8" Figure 9 - Rough Opening for Installing in Corner 2. An optional blower accessory is available (see Accessories , page 32). There are two options for connecting blower to electrical source.
13 102886 INST ALLING Continued Continued 6. Attach flexible gas line to fireplace gas regulator. See Connecting Fireplace to Gas Supply, page 17. 7. If the optional blower has been installed connect blower to electrical source. Option one: Route blower electrical cord through side or rear access door of fireplace.
14 102886 INST ALLING Continued Figure 12 - Attaching Brass Trim to Fireplace Shoulder Screws Assembled Brass Trim OPTIONAL MANTEL INSTALLATION Note: Refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installation.
15 102886 Attaching Wood Base to Solid Floor For attaching base to solid floors (concrete or masonry) Note: Floor anchors and mounting screws are in hardware package. The hardware package is provided with fireplace. 1. Drill holes at marked locations using 5/16" drill bit.
16 102886 CONNECTING T O GAS SUPPL Y Figure 16 - External Regulator with Vent Pointing Down NO TICE A qualified service person must connect fireplace to gas supply. Follow all local codes. WARNING ICON G 001 CA UTION Never connect fireplace directly to the propane/LP supply.
17 102886 Continued CONNECTING T O GAS SUPPL Y Continued Figure 18 - Removing Twig Support From Fireplace CONNECTING FIREPLACE TO GAS SUPPLY Installation Items Needed • Phillips screwdriver • sealant (resistant to propane gas, not provided) 1. Remove fireplace screen.
18 102886 CHECKING GAS CONNECTIONS PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1/2 PSIG 1. Disconnect fireplace and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage fireplace regulator.
19 102886 ON POSITION OFF POSITION Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 20). 2. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve. 3. Check all joints from propane/LP supply tank to manual shutoff valve (see Figure 21).
20 102886 OPERA TING FIREPLA CE FOR Y OUR SAFETY READ BEFORE LIGHTING Continued WARNING ICON G 001 W ARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. LIGHTING INSTR UCTIONS 1.
21 102886 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 20. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise C-clockwise to the PILOT position.
22 102886 T O TURN OFF GAS T O APPLIANCE Shutting Off Fireplace 1. Turn control knob clockwise Clockwise to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed. Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise Clockwise to the PILOT position.
23 102886 INSPECTING BURNER Thermocouple Pilot Burner Figure 24 - Correct Pilot Flame Pattern Thermocouple Pilot Burner Figure 25 - Incorrect Pilot Flame Pattern Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 24 shows a correct pilot flame pattern.
24 102886 BURNER FLAME PATTERN Figure 26 shows a correct burner flame pattern. Figure 27 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than one inch above the log.
25 102886 CLEANING AND MAINTENANCE ODS/PILOT AND BURNER • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean. CABINET Air Passageways • Use a vacuum cleaner or pressurized air to clean. Exterior • Use a soft cloth dampened with a mild soap and water mixture.
26 102886 Continued REMEDY 1. Turn on gas supply or open manual shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat ig- niting operation until air is removed 5.
27 102886 TR OUBLE- SHOO TING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during initial operation Fireplace produces a whistling noise when burner is lit POSSIBLE CAUSE 1.
28 102886 TR OUBLE- SHOO TING Continued WARNING ICON G 001 W ARNING If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
29 102886 TECHNICAL SER VICE You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190.
30 102886 12-1 12-2 23 29 32 36 37 13 7 33 11 8 10 17 17 8 7 30 3 1 2 9 19 6 22 31 21 40 27 38 39 16 15 18 24 28 5 34 26 25 20 35-1 35-2 12 24 12-1 25 14 4 VMH26TP.
31 102886 P AR TS LIST This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.
32 102886 A CCESSORIES Purchase these fireplace accessories from your local dealer. If they cannot supply these accessories call DESA International’s Sales Department at 1-800-458-2472 for referral information. You can also write to the address listed on the back page of this manual.
33 102886 NO TES _______________________________________________________________ _______________________________________________________________ _______________________________________________________.
34 102886 NO TES _______________________________________________________________ _______________________________________________________________ _______________________________________________________.
35 102886 NO TES _______________________________________________________________ _______________________________________________________________ _______________________________________________________.
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 102886-01 REV. D 06/97 LIMITED WARRANTY VENT-FREE PROPANE/LP GAS COMPACT CLASSIC HEARTH ‚ FIREPLACE DESA International warrants this.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vanguard VMH26TPB c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vanguard VMH26TPB - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vanguard VMH26TPB, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vanguard VMH26TPB va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vanguard VMH26TPB, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vanguard VMH26TPB.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vanguard VMH26TPB. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vanguard VMH26TPB ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.