Hand-Held

UBZZ01313ZZ Operating Guide



23 22 24

Before you use this scanner, please read and observe the following:
Earphone Warning! Be sure to use only the recommended optional monaural earphone (EP009). You may also use a 32Ωstereo headset. Use of an incorrect earphone or stereo headset may be potentially hazardous to your hearing. The output of the Phone jack is monaural, but you will hear it in both headphones of a stereo headset. Set the Volume to a comfortable audio level coming from the speaker before plugging in the monaural earphone or a stereo headset of the proper impedance (32Ω). Otherwise you might experience some discomfort or possible hearing damage if the volume suddenly becomes too loud because of the Volume Control or Squelch Switch setting. This may be particularly true of the type of earphone that is placed in the ear canal.
General Battery Warning! Do not short-circuit any battery. Do not discard batteries in a fire; they may explode.
Uniden® and Bearcat® are registered trademarks of Uniden America Corporation.


The BC45XLT Scanner is a sophisticated information radio that allows you to monitor 10 different frequency bands and the NOAA weather information broadcasts. It is a state-of-the-art radio with scanning capabilities, and it can save up to 20 different frequencies in memory.
Unlike standard AM or FM radio stations, most two-way communications do not transmit continuously. The BC45XLT scans programmed channels until it finds an active frequency.
Scanning stops on an active frequency and remains on that channel as long as the transmission continues. When the transmission ends, the scanning cycle resumes until another transmission is received.
You can program five different personal search bands in your new scanner. You simply select a Chain Search location, define the search range, and begin your search.
The scanner looks for active communications in the range you’ve specified, so you can locate frequencies in your area which may not be listed in your Betty Bearcat Starter Frequency Guide.
You can set your scanner to search up to all five Chain Search bands at once, or you can turn off those search bands you do not want. This gives you complete control of the search function.

Monitor communications such as:
29-29.7 MHz 10 Meter Amateur Band
29.7-50 MHz VHF Low Band
50-54 MHz 6 Meter Amateur Band
137-144 MHz Military Land mobile
144-148 MHz 2 Meter Amateur Band
148-174 MHz VHF High Band
406-420 MHz Federal Govt. Land Mobile
420-450 MHz 70 cm Amateur Band
450-470 MHz UHF Standard Band
470-512 MHz UHF “T” Band
Frequency Range Transmission


Before using your scanner, you must program frequencies into available channels. The Betty Bearcat Starter Frequency Guide lists typical frequencies used around the U.S.A. and Canada that you may program into your new scanner.
If the frequencies listed in the starter guide do not work in your area, call the Bearcat Frequency Hotline (937) 299-0414 (Hours are from 9:00 a.m. to 5:00 p.m. Eastern Time Monday through Friday) or you may want to visit their website at: www.bearcat1.com/free.htm
The Bearcat Radio Club and other similar hobby clubs have publications, information on computer bulletin boards, and even contests for the radio enthusiast.
You may also contact the Uniden Parts Dept. (800) 554-3988 (Hours are from 7:00 a.m. to 5:00 p.m. Central Time Monday through Friday) or visit our website at: www.uniden.com

If any of these items are missing or damaged, immediately contact your place of purchase or Uniden Parts Dept. at: (800) 554-3988, 7:00 a.m. to 5:00 p.m., Central Time Monday through Friday.





These are helpful guidelines when using your new scanner.



When the batteries are low, the battery icon appears in the display. Also an audible alert tone sounds every 15 seconds. Replace the batteries with four new ones. The information that you have previously entered will be retained in memory until the batteries are replaced.

and Indicators while reading this Guide.
Turn the VOLUME control clockwise out of the detent position. Adjust for a comfortable listening level. The scanner automatically starts scanning.
You can cut out weak transmissions and noise when you switch on this squelch function. This is a fixed squelch setting so you do not have to adjust the squelch yourself.

and noise.
Squelch ON Squelch OFF
Key Lock prevents accidental key entries during manual mode and search mode.


Before the BC45XLT can receive radio broadcasts, you must program a frequency into at least one channel. Before scanning, repeat this procedure for each channel you program.

Press L,M, or repeatedly until the channel number appears in the display.

number. b. Then press .
entering the frequency, press twice, and start over.
If the frequency entered is outside the Frequency Range of the scanner, a distinctive beep sounds. (See the Table on page 3 or the Band List on the back of the scanner).
Press and go back to Step 4.

If you enter a frequency stored in another channel, you hear a beep and another channel appears in the display.
Press to start again.
Press again to store the frequency in both channels.

When you turn on the power, the BC45XLT automatically starts in the Scan mode.
During normal scanning the scanner skips unprogrammed or locked out channels.

1 3 4 5 9 10 2 6 7 8 CHANNELS
When a transmission is received, the scanner stops on that channel. When the transmission ends, scanning resumes automatically after two seconds.
To stop on a channel during scanning, press .


You can lockout any channel so it is not reviewed during normal scanning. You can restore the channel to scanning whenever you wish.


Press L,M, or repeatedly until the channel number appears in the display.


If the scanner keeps stopping on a particular channel due to noise or too frequent transmissions, you may want to prevent the channel from being in the scanning sequence.

For example, if you are locking out channels 4, 7, 8, 12, and 15, start with Channel 4. After selecting channel 4, press . Then press one or more times to step up to the next channel to be locked out. • Record the locked-out channels in some convenient place so you can restore them.



Press L,M, or repeatedly until the channel number appears in the display.


Mode before restoring all locked-out channels.

You will hear two beeps when all the channels have been restored.
frequency entered are automatically locked out.

When Priority Scan is turned on, your scanner checks the priority channel every two seconds for activity. If a signal is present on the priority channel, your scanner monitors the channel until the transmission ends, then resumes normal scanning. You can designate any one of the 20 available channels as your Priority Channel.
To activate Priority Scan (in either Manual or Scan Mode):



You cannot eliminate the Priority Channel, but you can change it to any other of the 20 available channels.


Press L,M, or repeatedly until the channel number appears in the display.

Two beeps indicate that the Priority Channel is changed.
“P” icon appears in the display.

Use Chain Search to find active frequencies in your area. You can search all five personal bands at once or turn off those bands you don’t want to hear. This gives you flexibility of searching for any channel between 29 and 512 MHz, as long as they are within the 10 frequencies bands covered by the BC45XLT. See the table on page 3, the Technical Specifications on page 28, or the table on the back of the BC45XLT.
An error message displays when
is pressed and you have not either specified a search range in at least one Chain Search band.
If you attempt to turn off all Personal Chain Search bands.
The Error message turns off. Press to select the band you want to program.
To program a frequency range into one of the five personal Chain Search bands, follow these steps:

a. Enter the frequency
number. b. Then press .


between the upper and lower ranges.

a. Enter the frequency
number. b. Then press .

between the upper and lower ranges. If you program the wrong limit, then “Error” displays. To reset the “Error” message, press key. You can set the limit frequency.

each selected Personal Chain Search band. The display flashes the band it is searching.
Press to move to the next chain location.

To turn off a Chain Search band during search scanning, press its location number.

For example, (a) if Chain Search locations 1, 2 and 3 are selected, (b) press to turn off band three so that it is not scanned during your search.



Press to move down to the previous frequency.

toward either the upper or lower search limit, depending on which direction key ( or ) was pressed last.

If a particular channel continues to interrupt search scanning, it is possible to set your scanner to skip the frequency.
If your scanner stops while searching, press to lockout the frequency from the search range.

frequencies. The 11th skip frequency entered causes the 1st skip frequency to unlock.
To unlock all skip frequencies at once, follow these steps:

Hold before restoring all skipped frequencies.

You will hear two beeps when all the channels have been restored.

You can quickly store any frequency you find during Search.
store the frequency before entering the search mode. Otherwise, you may erase a stored frequency that you want to keep.


Press L,M, or repeatedly until the channel number appears in the display.

For example, select CHAIN 2.

used during “Setting a Search Range,” on page 18.

search Hold mode. Press
to resume scanning.


manual mode.
Repeat steps 2 through 6 for all the Search frequencies you want to store.
store frequencies, whether you program them directly or while using the Chain Search mode.

Your BC45XLT is designed to scan 7 programmed NOAA frequencies, so you easily find your local NOAA weather broadcast.
one of the 20 channels since weather channels transmit continuously. The scanner will remain on the weather channel, disrupting the scanning cycle.

to deactivate the squelch.

monitor weather broadcasts, such as in low-lying areas. Normally, a higher location or a better antenna improves reception.
weather station, press


Press to lockout the channel, and then press to resume scanning.

If your BC45XLT is not performing properly, try the following steps.
If you still cannot get satisfactory results and want additional information, or to return the unit for service, please call or write the Uniden Customer Service. The address and phone number are listed in the Warranty at the end of this manual, or call 1-800-297-1023.

Certified in accordance with FCC Rules and Regulations Part 15, Subpart C, as of date of manufacture.
29.7 – 50 MHz VHF Low Band 50 – 54 MHz 6 Meter Amateur Band 137 – 144 MHz Military Land Mobile 144 – 148 MHz 2 Meter Amateur Band 148 – 174 MHz VHF High Band Above bands in 5 kHz steps
Audio Output: 240 mW nominal into 8Ωinternal speaker 110 mW nominal into 32Ωstereo headphone 33 mW nominal into 64Ωearphone
Size: 2 1/2 in. (W) x 1 1/2 in. (D) x 7 in. (H)
Features, specifications, and availability of optional accessories are all subject to change without notice.




for warranty service.
WARRANTOR: UNIDEN AMERICA CORPORATION (“Uniden”) ELEMENTS OF WARRANTY: Uniden warrants, for one year, to the original retail owner, this Uniden product to be free from defects in materials and craftsmanship with only the limitations or exclusions set out below.
WARRANTY DURATION: This warranty to the original user shall terminate and be of no further effect 12 months after the date of original retail sale. The warranty is invalid if the Product is (A) damaged or not maintained as reasonable or necessary, (B) modified, altered, or used as part of any conversion kits, subassemblies, or any configurations not sold by Uniden, (C) improperly installed, (D) serviced or repaired by someone other than an authorized Uniden service center for a defect or malfunction covered by this warranty, (E) used in any conjunction with equipment or parts or as part of any system not manufactured by Uniden, or (F) installed or programmed by anyone other than as detailed by the owners manual for this product.
STATEMENT OF REMEDY: In the event that the product does not conform to this warranty at any time while this warranty is in effect, warrantor will either, at its option, repair or replace the defective unit and return it to you without charge for parts, service, or any other cost (except shipping and handling) incurred by warrantor or its representatives in connection with the performance of this warranty. Warrantor, at its option, may replace the unit with a new or refurbished unit. THE LIMITED WARRANTY SET FORTH ABOVE IS THE SOLE AND ENTIRE WARRANTY PERTAINING TO THE PRODUCT AND IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES OF ANY NATURE WHATSOEVER, WHETHER EXPRESS, IMPLIED OR ARISING BY OPERATION OF LAW INCLUDING, BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY DOES NOT COVER OR PROVIDE FOR THE REIMBURSEMENT OR PAYMENT OF INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow this exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you.
LEGAL REMEDIES: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. This warranty is void outside the United States of America.
PROCEDURE FOR OBTAINING PERFORMANCE OF WARRANTY: If, after following the instructions in the owners manual you are certain that the product is defective, pack the Product carefully (preferably in its original packaging). The product should include all parts and accessories originally packaged with the Product. Include evidence of original purchase and a note describing the defect that has caused you to return it. The Product should be shipped freight prepaid, by traceable means, to warrantor at:
UNIDEN AMERICA CORPORATION Parts and Service Division 4700 Amon Carter Blvd Fort Worth, TX 76155 (800) 554-3988, 7a.m. To 5p.m. Central, Monday through Friday

Covered under one or more of the following U.S. patents:
4,398,304 4,409,688 4,455,679 4,461,036
4,521,915 4,597,104 4,627,100 4,841,302
4,888,815 4,932,074 4,947,456 5,014,348
5,199,109 5,408,692 5,428,826 5,438,688
5,448,256 5,465,402 5,471,660 5,483,684
5,530,296 5,548,832 5,551,071 5,574,995
5,577,076 5,598,430 5,600,223 5,642,424
and other patents pending.
© 2000 Uniden America Corporation. All rights reserved. UBZZ01313ZZ Printed in the Philippines