Topcom 5331 WHO

76 pages·2.1 MB·Tensiomètre·PDF·ENITJA
Topcom 5331 WHO
Table des matières 23 sections BPM WRIST 5331 WHO · ANVÄNDARHANDBOK / KÄYTTÖOHJE · EC REP · 3 Helpful tips · … AfficherMasquer
Page 1 of the Topcom 5331 WHO user manual — ANVÄNDARHANDBOK / KÄYTTÖOHJE
Page 1 · cliquer pour agrandir
Page 1

BPM WRIST 5331 WHO

Topcom 5331 WHO — BPM WRIST 5331 WHO diagram (page 1)
Fig. 1

USER GUIDE / HANDLEIDING / MANUEL D’UTILISATEUR GEBRAUCHSANWEISUNG / BRUKSANVISNING / BRUGERVEJLEDNING

ANVÄNDARHANDBOK / KÄYTTÖOHJE

Page 2 of the Topcom 5331 WHO user manual — EC REP
Page 2 · cliquer pour agrandir
Page 2

UK The features described in this manual are published with reservation to modifications. NL De in deze handleiding beschreven mogelijkheden worden gepubliceerd onder voorbehoud van wijzigingen. F Les possibilités décrites dans ce manuel sont publiées sous réserve de modifications. D Die in dieser Bedienungsanleitung umschriebenen Möglichkeiten, werden vorbehaltlich Änderungen publiziert. S Funktionerna i denna bruksanvisning publiceras med reservation för ändringar. DK Vi forbeholder os retten til ændringer af de specifikationer, der er beskrevet i denne brugsanvisning. N Funksjoner beskrevet i denne manualen kan endres uten nærmere informasjon. SF Tässä ohjekirjassa julkaissut tiedot voivat muuttua ilman ennakkoilmoitusta.

Authorized Representative in the European Community Topcom Europe NV, Grauwmeer 17 3001 Heverlee, Belgium,

EC REP

Manufacturer Health & Life Co., Ltd. 9F No.186, Jian Yi Road Chung Ho City, Taipei, Taiwan

This Blood Pressure Monitor complies with the EC Directives

and bears the CE Mark "CE 0197".

This product is in compliance with the essential requirements

and other relevant provisions of the directive 93/42/EEC.

The declaration of conformity can be found on: http://www.topcom.net/support/cedeclarations.php

The quality of the device has been verified and is in line with the provisions of the EC council directive 93/42/EEC (EN IEC60601-1-General requirements for safety, EN IEC 60601-1-2:2001 - Electromagnetic compatibility-Requirements and tests) dated 14 June 1993 concerning medical devices and the EN performance standards as follow:

  • EN 1060-1 Non-invasive sphygmomanometers - General requirements
  • EN 1060-3 Non-invasive sphygmomanometers - Supplementary requirements for electromechanical blood pressure measuring systems.
  • EN 1060-4 Non-invasive sphygmomanometers - Test procedures to determine the overall system accuracy of automated non-invasive sphygmomanometers.
Page 3 of the Topcom 5331 WHO user manual — EC REP
Page 3 · cliquer pour agrandir
Page 3

1 Introduction Congratulations with your purchase of the Topcom BPM Wrist 5331. This fully automatic, wrist mounted blood pressure monitor is both easy to use and ideally suited for daily measurements. The large display includes systolic, diastolic and pulse, all clearly shown at the completion of each reading. In addition, you can store up to 30 measurements per Memory Zone, ideal for users who want to monitor and track their blood pressure on a regular basis. The BPM wrist 5331 is compact and portable, making it ideal for home use and travel.

Please read this manual carefully before use. For specific information on your own blood pressure, contact your physician. Put the user guide away in a safe place for future reference.

2 Safety instructions 1. This product is for household use only. It is not intended as a substitute for consultation with your doctor. 2. For users diagnosed with common arrhythmia (atrial or ventricular premature beats or atrial fibrillation), diabetes, poor circulation of blood, kidney problems, or for users suffered from stroke, or for unconscious users, the device might not be suitable for use. Consult your doctor in case of any doubt. 3. The unit should not be operated by children so to avoid hazardous situations. 4. The unit contains high-precision assemblies. Therefore, avoid extreme temperatures, humidity, and direct sunlight. Avoid dropping or strongly shocking the main unit, and protect it from dust. 5. Leaky batteries can damage the unit. Remove the batteries when the unit is not used for a long time. 6. Do not press the START key when the cuff is not placed around the wrist. 7. Do not disassemble the main unit or cuff. 8. If the unit is stored in a cold place, allow it to acclimate at room temperature before use. 9. Clean the blood pressure monitor body and the cuff carefully with a slightly damp, soft cloth. Do not press. Do not bend the pre-formed cuff inside out. Do not wash the cuff or use chemical cleaner on it. Never use thinner, alcohol or petrol (gasoline) as cleaner.

To avoid inaccurate results caused by electromagnetic interference between electrical and electronic equipments, do not use the device near a cell phone or microwave oven.

Page 4 of the Topcom 5331 WHO user manual — 5.2 Why Measure Your Blood Pressure?
Page 4 · cliquer pour agrandir
Page 4

3 Helpful tips

Here are a few helpful tips to help you obtain more accurate readings:

  • Do not measure your blood pressure immediately after consuming a large meal. To obtain more accurate readings, please wait one hour before measuring.
  • Do not smoke or drink alcohol before measuring your blood pressure.
  • You should not be physically tired or exhausted while taking a measurement.
  • It is important that you relax during measurement. Try to take 15-minutes rest before a reading.
  • Do not take measurements if you are under stress or under tension.
  • Take your blood pressure at normal body temperature. If you are feeling cold or hot, wait a while before taking a measurement.
  • If the monitor is stored at very low temperature (near freezing), have it placed at a warm location for at least one hour before using it.
  • Wait about 5 minutes before taking the next pressure measurement.

4 Disposal of the device

At the end of the product lifecycle, you should not throw this product into the normal household garbage but bring the product to a collection point for the recycling of electrical and electronic equipments. The symbol on the product, user guide and/or box indicate this. Some of the product materials can be re-used if you bring them to a recycling point. By re-using some parts or raw materials from used products you make an important contribution to the protection of the environment. Please contact your local authorities in case you need more information on the collection points in your area.

5 Blood pressure

5.1 What is Blood Pressure?

Blood pressure is the pressure exerted on the artery tube while blood flows through the arteries. The pressure measured when the heart contracts and sends blood out of the heart is systolic (highest). The pressure measured when the heart dilates with blood flowing back into the heart is called diastolic (lowest) blood pressure.

5.2 Why Measure Your Blood Pressure?

Among the various health problems afflicting modern people, problems associated with high blood pressure are by far the most common. High blood pressure's dangerously strong correlation with cardiovascular diseases and high morbidity has made measuring blood pressures a necessity of identifying those at risk.

Page 5 of the Topcom 5331 WHO user manual — 6 Battery installation
Page 5 · cliquer pour agrandir
Page 5
Topcom 5331 WHO — 5.4 Blood Pressure Fluctuation diagram (page 5)
Fig. 2 · 5.4 Blood Pressure Fluctuation

The World Health Organization (WHO) and National High Blood Pressure Education Program has developed a Blood pressure standard, according to which areas of low and high-risk blood pressure are identified. This standard however, is a general guideline as individual's blood pressure varies among different people and different groups, ... etc.

It is important that you consult with your physician regularly. Your physician will tell you your normal blood pressure range as well as the point at which you will be considered at risk.

The BPM Wrist 5331 WHO will indicate if your boarder line of either Systolic or DIastolic is exceeded. If the boarderline is crossed, the display will light RED. If your result is below the limit, the display will light Blue. The limits can be personalized (see chapter 12.2)

5.4 Blood Pressure Fluctuation

Blood pressure fluctuates all the time! You should not be worried if you encountered two or three measurements at high levels. Blood pressure changes over the month and even throughout the day depending on circumstances (state of mind, temperature, ...)

6 Battery installation

Topcom 5331 WHO — 6 Battery installation diagram (page 5)
Fig. 3 · 6 Battery installation
  • Open the battery compartment by pulling the cover away
  • Insert 2 AAA non - rechargeable (Alkaline) batteries. Follow the polarity as indicated in the battery compartment.
  • Re-install the battery cover.

Do not shortcircuit & dispose of in fire. Remove the battery if this device is not going to be used for a long period. Do not shortcircuit & dispose of in fire. Remove the battery if this device is not going to be used for a long period.

Page 6 of the Topcom 5331 WHO user manual — 8 Display
Page 6 · cliquer pour agrandir
Page 6

7 Buttons

Topcom 5331 WHO — 7 Buttons diagram (page 6)
Fig. 4 · 7 Buttons
1. Up / Down button 2. LCD display 3. MEMORY RECALL button 4. Wrist cuff 5. START / STOP button 6. MODE button 7. Battery compartment

8 Display

Topcom 5331 WHO — 8 Display diagram (page 6)
Fig. 5 · 8 Display
1. Systolic pressure 2. Diastolic pressure 3. Pulse rate 4. Battery Low indicator 5. Memory number 6. Memory zone 7. Error icon 8. Blood pressure unit 9. Time 10. Date

9 Applying the cuff 1. Remove all watches, jewelry, etc. prior to attaching the wrist monitor.Clothing sleeves should be rolled up and the cuff should be wrapped on bare skin for correct measurements. Apply cuff to left wrist with palm facing up.

2. Make sure the edge of the cuff is about 1 cm from the palm. In order to insure accurate-measurements.
Page 7 of the Topcom 5331 WHO user manual — 11.1 Important
Page 7 · cliquer pour agrandir
Page 7
3. Fasten the velcro strap securely around your wrist so there is no extra space between the cuff and the wrist. If the cuff is not wrapped tight enough, the measurement values will be false.
4. If your physician has diagnosed you with poor circulation on your left arm, place the cuff around your right wrist.

10 Measuring posture 1. Relax your entire body,especially the area between your elbow and fingers. Place your elbow on a table so that the cuff is at the same level as your heart.

Your heart is located slightly below your arm pit.

2. If the cuff is not at the same level as your heart or if you can not keep your arm completely still throughout the reading, use a soft object such as folded towel to support your arm.

(X)

3. Turn your palm upwards.Sit upright in a chair, and take 5-6 deep breaths. Avoid leaning back while the measurement is being taken.

11 Measurement

11.1 Important

1. This will monitor automatically switches off 1 minute after the last key operation. 2. To interrupt the measurement, simply press any key. The cuff will deflate immediately after a key is pressed. 3. During the measurement, do not talk or move your arm or hand muscles. 4. The result will be stored automatically in the selected Memory Zone. Select the desires Memory Zone before measurement (see §12)
Page 8 of the Topcom 5331 WHO user manual — 12.2 Maximum blood pressure level
Page 8 · cliquer pour agrandir
Page 8

12 Settings

12.1 time adjustment

To adjust the date an time:

  • Press the START/STOP button to activate the display.
  • Press the MODE button, the month will blink on the display.
  • Press the UP or DOWN button to change the month.
  • Press the MODE button to confirm the month. The day will blink on the display.
  • Change the day, hours and minutes as described above, using the the UP or DOWN button to change and the MODE button to confirm every setting.

12.2 Maximum blood pressure level

After setting the minutes, the setting of personal Blood pressure level limits is not active. (- -) is displayed.

  • Press the Memory button, the Systolic pressure limit is flashing.
  • Press the UP or DOWN button to set your personal systolic pressure limit.
  • Press the MODE button to confirm. The DIASTOLIC pressure level is flashing.
  • Press the UP or DOWN button to set your personal diastolic pressure limit.
  • Press the MODE button to confirm.

The unit is now ready to use.

13 Procedure 1. Press the START/STOP button to activate the display.

2. Press the UP or DOWN button to select the desired memory zone.
Page 9 of the Topcom 5331 WHO user manual — 12 Settings
Page 9 · cliquer pour agrandir
Page 9
3. Press the START/STOP button to start measurement. The cuff will inflate to the level that is right for you.
4. When the right level is reached, the cuff will deflate.

This monitor will re-inflate automatically to approximately 220mmHg if the system detects that your body needs more pressure to measure your blood pressure.

When the measurement is completed, systolic, diastolic and pulse will be shown simultaneously on the LCD screen.

When the Systolic or the Diastolic pressure level has exceeded the set maximum level, the display will light up RED.

RED light is a warning signal to suggest you to consult your phsician.

When the Systolic or the Diastolic pressure level has not exceeded the set maximum level, the display will light up Blue.

5. When a mistake was detected during measurement the Error icon appears on the display

14 Memory The BPM 5331 has 3 Memory zones. Each can store up to 30 measurements including the date and time The result will be stored automatically in the selected Memory Zone after the measurement.

Topcom 5331 WHO — 12 Settings diagram (page 9)
Fig. 6 · 12 Settings
  • To recall measurement results:
  • Press the START/STOP button to activate the display.
  • Press the UP or DOWN button to select the desired memory zone.
  • Press the MEMORY RECALL button to see the average of the last 3 measurement results [A]
  • Press the MEMORY RECALL button repeatedly to see prior stored measurement results.
  • To stop reading the data, press the START/STOP button to switch back to normal time.
Page 10 of the Topcom 5331 WHO user manual — 15 Technical specifications
Page 10 · cliquer pour agrandir
Page 10

To erase all data from one memory zone:

  • Press the START/STOP button to activate the display.
  • Press the UP or DOWN button to select the desired memory zone.
  • Press the MEMORY RECALL button to see the average of all measurement results.
  • Press the MODE and the UP button simultaneously to erase all data from the selected memory zone.

15 Technical specifications

Power source Measurement method Measurement zone

  • 3V DC: Two LR03 (AAA) Non rechargeable batteries Oscillometric Pressure: 0 ~ 300 mmHg Pulse: 40 ~ 199 beats/minute Pressure: ± 3 mmHg Pulse: within ± 5% of reading Semi-conductor Pump driven Automatic Pressure release valve 3 Memory zones for each 30 memories 1 minute after last key operation +10°C ~ + 40°C < 85% RH -20°C ~ + 70°C < 85% RH 120g (without batteries) 135 ~ 195 mm Over 18 years old 74(L) x 84(W) x 32(H) mm Short time operation 2 minutes
  • Internally powered equipment
  • Classification of type BF (applied part)
  • IPX0
  • Not suitable for use in presence of flammable anaesthetic mixture with air or with oxygen or nitrous oxide
  • Continuous operation with short-time loading

Pressure sensor Inflation Deflation Memory capacity Auto-shut-off Operation environment

Weight Wrist circumference Limited patient Dimensions K.B.

*Specifications are subject to change without notice.

Accuracy · Storage environment · Classification

Page 11 of the Topcom 5331 WHO user manual — 16.3 Warranty exclusions
Page 11 · cliquer pour agrandir
Page 11

The CE symbol indicates that the unit complies with the essential

requirements of the 93/42/EEC directive.

16 Topcom Warranty

16.1 Warranty period

The Topcom units have a 24-month warranty period. The warranty period starts on the day the new unit is purchased. Consumables or defects causing a negligible effect on operation or value of the equipment are not covered. The warranty has to be proven by presentation of the original purchase receipt, on which the date of purchase and the unit-model are indicated.

16.2 Warranty handling

A faulty unit needs to be returned to a Topcom service centre including a valid purchase note. If the unit develops a fault during the warranty period, Topcom or its officially appointed service centre will repair any defects caused by material or manufacturing faults free of charge. Topcom will at its discretion fulfill its warranty obligations by either repairing or exchanging the faulty units or parts of the faulty units. In case of replacement, colour and model can be different from the original purchased unit. The initial purchase date shall determine the start of the warranty period. The warranty period is not extended if the unit is exchanged or repaired by Topcom or its appointed service centres.

16.3 Warranty exclusions

Damage or defects caused by incorrect treatment or operation and damage resulting from use of non-original parts or accessories not recommended by Topcom are not covered by the warranty. The warranty does not cover damage caused by outside factors, such as lightning, water and fire, nor any damage caused during transportation. No warranty can be claimed if the serial number on the units has been changed, removed or rendered illegible.

Poser une question sur : Topcom 5331 WHO

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Topcom 5331 WHO

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Topcom 5331 WHO manuel PDF

76 pages·2.1 MB·Tensiomètre·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…