FR
Tektronix logo
Notice d'utilisation officielle

Tektronix VX4801

91 pages·2.3 MB·Système de soudage·PDF·EN
Tektronix VX4801
Table des matières 38 sections User Manual · VX4801 Programmable Digital I/O Module · 070-9153-03 · WARRANTY · … AfficherMasquer
Page 1 of the Tektronix VX4801 user manual — User Manual
Page 1 · cliquer pour agrandir
Page 1

User Manual

VX4801 Programmable Digital I/O Module

070-9153-03

This document applies for firmware version 1.00 and above.

Page 2 of the Tektronix VX4801 user manual — User Manual
Page 2 · cliquer pour agrandir
Page 2

Copyright Tektronix, Inc. All rights reserved.

Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved.

Printed in the U.S.A.

Tektronix, Inc., P.O. Box 1000, Wilsonville, OR 97070–1000

TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.

Page 3 of the Tektronix VX4801 user manual — WARRANTY
Page 3 · cliquer pour agrandir
Page 3

WARRANTY

Tektronix warrants that this product will be free from defects in materials and workmanship for a period of three (3) years from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product.

In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.

This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; or c) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product.

THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THIS PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.

Page 4 of the Tektronix VX4801 user manual — EC Declaration of Conformity
Page 4 · cliquer pour agrandir
Page 4

EC Declaration of Conformity

Tektronix Holland N.V. Marktweg 73A 8444 AB Heerenveen The Netherlands declare under sole responsibility that the

VX4801 meets the intent of Directive 89/336/EEC for Electromagnetic Compatibility. Compliance was demonstrated to the following specifications as listed in the Official Journal of the European Communities:

EN 55011 Class A Radiated and Conducted Emissions EN 50081-1 Emissions:

EN 60555-2 AC Power Line Harmonic Emissions

EN 50082-1 Immunity:

IEC 801-2 Electrostatic Discharge Immunity IEC 801-3 RF Electromagnetic Field Immunity IEC 801-4 Electrical Fast Transient/Burst Immunity IEC 801-5 Power Line Surge Immunity

To ensure compliance with EMC requirements this module must be installed in a mainframe which has backplane shields installed which comply with Rule B.7.45 of the VXIbus Specification. Only high quality shielded cables having a reliable, continuous outer shield (braid & foil) which has low impedance connections to shielded connector housings at both ends should be connected to this product.

We

Page 5 of the Tektronix VX4801 user manual — EC Declaration of Conformity
Page 5 · cliquer pour agrandir
Page 5
Tektronix VX4801 — EC Declaration of Conformity diagram (page 5)
Fig. 1 · EC Declaration of Conformity
Page 6 of the Tektronix VX4801 user manual — EC Declaration of Conformity
Page 6 · cliquer pour agrandir
Page 6
Tektronix VX4801 — EC Declaration of Conformity diagram (page 6)
Fig. 2 · EC Declaration of Conformity
Page 7 of the Tektronix VX4801 user manual —    $ $#
Page 7 · cliquer pour agrandir
Page 7

$ $#

$ " " $ ! $ #

0641'7&6,10 10641.5 0' 0',&$6145 9,6&+(5 75(5 5 7,.6=0 (56 37,2/(06 .155$4; 2(&,),&$6,105

$ "!"$ " #

056$..$6,10 (37,4(/(065 0' $76,105 056$..$6,10 41&('74( 056$..$6,10 +(&-.,56

8(48,(9 19(4=72 ;56(/ 1//$0'5 1'7.( 2(4$6,10 1//$0' ;06$: 1//$0' 7//$4; 1//$0' (5&4,26,105 # (.) (56 $0' 0,6,$.,

$ " " % ! #

(),0,6,10 1) 1//$0'5 41*4$//,0* :$/2.( 0

22(0',: !"%75 2(4$6,10 22(0',: 027676276 100(&6,105 22(0',: !" .155$4; 22(0',: 5(4 (48,&( 22(0',: (4)14/$0&( !(4,),&$6,10

$ !"$ · !! # ·

Page 8 of the Tektronix VX4801 user manual — Suspected Failures
Page 8 · cliquer pour agrandir
Page 8

General Safety Summary

Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it.

Only qualified personnel should perform service procedures.

While using this product, you may need to access other parts of the system. Read the General Safety Summary in other system manuals for warnings and cautions related to operating the system.

Injury Precautions

To avoid electric shock or fire hazard, do not apply a voltage to a terminal that is outside the range specified for that terminal.

Avoid Electric Overload

To avoid electric shock or fire hazard, do not operate this product with covers or panels removed.

Do Not Operate Without

Covers

To avoid fire hazard, use only the fuse type and rating specified for this product.

Use Proper Fuse

Do Not Operate in Wet/Damp Conditions

To avoid electric shock, do not operate this product in wet or damp conditions.

Do Not Operate in an Explosive Atmosphere

To avoid injury or fire hazard, do not operate this product in an explosive atmosphere.

Product Damage Precautions

Provide Proper Ventilation

To prevent product overheating, provide proper ventilation.

Do Not Operate With

If you suspect there is damage to this product, have it inspected by qualified service personnel.

Suspected Failures

VX4801 Programmable Digital I/O Module iii

Page 9 of the Tektronix VX4801 user manual — Overvoltage Category
Page 9 · cliquer pour agrandir
Page 9

Safety Terms and Symbols

Terms in This Manual

These terms may appear in this manual:

These terms may appear on the product:

Terms on the Product

The following symbols may appear on the product:

Symbols on the Product

Double Insulated DANGER High Voltage

Certifications and Compliances

Overvoltage categories are defined as follows:

Overvoltage Category

CAT IIIDistribution level mains, fixed installation
CAT IILocal level mains, appliances, portable equipment
CAT ISignal level, special equipment or parts of equipment, telecommunication, electronics

iv VX4801 Programmable Digital I/O Module

General Safety Summary · Protective Ground · (Earth) Terminal

Page 10 of the Tektronix VX4801 user manual — Safety Terms and Symbols
Page 10 · cliquer pour agrandir
Page 10
Tektronix VX4801 — Safety Terms and Symbols diagram (page 10)
Fig. 3 · Safety Terms and Symbols
Page 11 of the Tektronix VX4801 user manual — Safety Terms and Symbols
Page 11 · cliquer pour agrandir
Page 11
Tektronix VX4801 — Safety Terms and Symbols diagram (page 11)
Fig. 4 · Safety Terms and Symbols
Page 12 of the Tektronix VX4801 user manual — Safety Terms and Symbols
Page 12 · cliquer pour agrandir
Page 12
Tektronix VX4801 — Safety Terms and Symbols diagram (page 12)
Fig. 5 · Safety Terms and Symbols
Page 13 of the Tektronix VX4801 user manual — Safety Terms and Symbols
Page 13 · cliquer pour agrandir
Page 13
Tektronix VX4801 — Safety Terms and Symbols diagram (page 13)
Fig. 6 · Safety Terms and Symbols
Page 14 of the Tektronix VX4801 user manual — Safety Terms and Symbols
Page 14 · cliquer pour agrandir
Page 14
Tektronix VX4801 — Safety Terms and Symbols diagram (page 14)
Fig. 7 · Safety Terms and Symbols
Page 15 of the Tektronix VX4801 user manual — Safety Terms and Symbols
Page 15 · cliquer pour agrandir
Page 15
Tektronix VX4801 — Safety Terms and Symbols diagram (page 15)
Fig. 8 · Safety Terms and Symbols
Page 16 of the Tektronix VX4801 user manual — Safety Terms and Symbols
Page 16 · cliquer pour agrandir
Page 16
Tektronix VX4801 — Safety Terms and Symbols diagram (page 16)
Fig. 9 · Safety Terms and Symbols
Page 17 of the Tektronix VX4801 user manual — Safety Terms and Symbols
Page 17 · cliquer pour agrandir
Page 17
Tektronix VX4801 — Safety Terms and Symbols diagram (page 17)
Fig. 10 · Safety Terms and Symbols
Page 18 of the Tektronix VX4801 user manual — Safety Terms and Symbols
Page 18 · cliquer pour agrandir
Page 18
Tektronix VX4801 — Safety Terms and Symbols diagram (page 18)
Fig. 11 · Safety Terms and Symbols
Page 19 of the Tektronix VX4801 user manual — Safety Terms and Symbols
Page 19 · cliquer pour agrandir
Page 19
Tektronix VX4801 — Safety Terms and Symbols diagram (page 19)
Fig. 12 · Safety Terms and Symbols
Page 20 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 20 · cliquer pour agrandir
Page 20
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 20)
Fig. 13

min typ max units

Output high voltage (Voh)

Io = –20 A lo = –6 mA Output low voltage (Vol)

4.4 3.84 5.0 4.2 V V

lo = 20 A lo = 24 mA Output low current (lol) Input high voltage (Vih) Input low voltage (Vil) * Input current (lin) Tri-state leakage current (loz)

0 0 0.1 0.5 V V 24 mA 2.0 V 0.8 V 230 A A 5.0 0.5

* There are 22 k pull-up resistors to + 5V on all I/O and handshake lines to account for floating inputs. The inputs IC use 1.0 A max, while the pull-down resistors require 5V / 22 k = 227.6 A.

–10 ° to +55 ° C., typical specs at 25° C. A minus sign indicates current flowing out of the card.

Page 21 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 21 · cliquer pour agrandir
Page 21
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 21)
Fig. 14
Page 22 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 22 · cliquer pour agrandir
Page 22
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 22)
Fig. 15
Page 23 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 23 · cliquer pour agrandir
Page 23
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 23)
Fig. 16
Page 24 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 24 · cliquer pour agrandir
Page 24
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 24)
Fig. 17
Page 25 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 25 · cliquer pour agrandir
Page 25
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 25)
Fig. 18
Page 26 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 26 · cliquer pour agrandir
Page 26
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 26)
Fig. 19
Page 27 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 27 · cliquer pour agrandir
Page 27
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 27)
Fig. 20
Page 28 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 28 · cliquer pour agrandir
Page 28
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 28)
Fig. 21
Page 29 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 29 · cliquer pour agrandir
Page 29
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 29)
Fig. 22
Page 30 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 30 · cliquer pour agrandir
Page 30
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 30)
Fig. 23
Page 31 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 31 · cliquer pour agrandir
Page 31
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 31)
Fig. 24
Page 32 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 32 · cliquer pour agrandir
Page 32
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 32)
Fig. 25
Page 33 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 33 · cliquer pour agrandir
Page 33
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 33)
Fig. 26
Page 34 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 34 · cliquer pour agrandir
Page 34
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 34)
Fig. 27
Page 35 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 35 · cliquer pour agrandir
Page 35
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 35)
Fig. 28
Page 36 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 36 · cliquer pour agrandir
Page 36
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 36)
Fig. 29
Page 37 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 37 · cliquer pour agrandir
Page 37
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 37)
Fig. 30
Page 38 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 38 · cliquer pour agrandir
Page 38
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 38)
Fig. 31
Page 39 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 39 · cliquer pour agrandir
Page 39
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 39)
Fig. 32
Page 40 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 40 · cliquer pour agrandir
Page 40
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 40)
Fig. 33
Page 41 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 41 · cliquer pour agrandir
Page 41
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 41)
Fig. 34
Page 42 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 42 · cliquer pour agrandir
Page 42
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 42)
Fig. 35
Page 43 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 43 · cliquer pour agrandir
Page 43
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 43)
Fig. 36
Page 44 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 44 · cliquer pour agrandir
Page 44
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 44)
Fig. 37
Page 45 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 45 · cliquer pour agrandir
Page 45
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 45)
Fig. 38
Page 46 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 46 · cliquer pour agrandir
Page 46
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 46)
Fig. 39
Page 47 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 47 · cliquer pour agrandir
Page 47
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 47)
Fig. 40
Page 48 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 48 · cliquer pour agrandir
Page 48
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 48)
Fig. 41
Page 49 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 49 · cliquer pour agrandir
Page 49
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 49)
Fig. 42
Page 50 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 50 · cliquer pour agrandir
Page 50
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 50)
Fig. 43
Page 51 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 51 · cliquer pour agrandir
Page 51
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 51)
Fig. 44
Page 52 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 52 · cliquer pour agrandir
Page 52
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 52)
Fig. 45
Page 53 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 53 · cliquer pour agrandir
Page 53
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 53)
Fig. 46
Page 54 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 54 · cliquer pour agrandir
Page 54
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 54)
Fig. 47
Page 55 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 55 · cliquer pour agrandir
Page 55
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 55)
Fig. 48
Page 56 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 56 · cliquer pour agrandir
Page 56
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 56)
Fig. 49
Page 57 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 57 · cliquer pour agrandir
Page 57
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 57)
Fig. 50
Page 58 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 58 · cliquer pour agrandir
Page 58
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 58)
Fig. 51
Page 59 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 59 · cliquer pour agrandir
Page 59
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 59)
Fig. 52
Page 60 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 60 · cliquer pour agrandir
Page 60
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 60)
Fig. 53
Page 61 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 61 · cliquer pour agrandir
Page 61
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 61)
Fig. 54
Page 62 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 62 · cliquer pour agrandir
Page 62
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 62)
Fig. 55
Page 63 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 63 · cliquer pour agrandir
Page 63
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 63)
Fig. 56
Page 64 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 64 · cliquer pour agrandir
Page 64
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 64)
Fig. 57
Page 65 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 65 · cliquer pour agrandir
Page 65
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 65)
Fig. 58
Page 66 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 66 · cliquer pour agrandir
Page 66
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 66)
Fig. 59
Page 67 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 67 · cliquer pour agrandir
Page 67
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 67)
Fig. 60
Page 68 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 68 · cliquer pour agrandir
Page 68
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 68)
Fig. 61
Page 69 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 69 · cliquer pour agrandir
Page 69
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 69)
Fig. 62
Page 70 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 70 · cliquer pour agrandir
Page 70
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 70)
Fig. 63
Page 71 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 71 · cliquer pour agrandir
Page 71
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 71)
Fig. 64
Page 72 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 72 · cliquer pour agrandir
Page 72
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 72)
Fig. 65
Page 73 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 73 · cliquer pour agrandir
Page 73
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 73)
Fig. 66
Page 74 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 74 · cliquer pour agrandir
Page 74
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 74)
Fig. 67
Page 75 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 75 · cliquer pour agrandir
Page 75
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 75)
Fig. 68
Page 76 of the Tektronix VX4801 user manual — 4.4 3.84 5.0 4.2 V V
Page 76 · cliquer pour agrandir
Page 76
Tektronix VX4801 — 4.4 3.84 5.0 4.2 V V diagram (page 76)
Fig. 69

Page 77 of the Tektronix VX4801 user manual — General Information and Conventions
Page 77 · cliquer pour agrandir
Page 77

Appendix E: Performance Verification 123

This procedure verifies the performance of the VX4801 Programmable Digital I/O Module. The test sequences may be performed in your current VXIbus system if it meets the requirements described in Table 2. Also, it is not necessary to complete the entire procedure if you are only interested in a specific perfor- mance area. Some tests depend on the proper operation of previously verified functions so it is best to follow the order as presented.

The following skills are required to perform this procedure:

Thorough knowledge of test instrument operation and proper measurement techniques

Knowledge of VXIbus system components and command language programming

Ability and facility to construct interconnections and fixtures as needed to perform the procedure

General Information and Conventions

Please familiarize yourself with the following conventions which apply throughout this procedure:

Each test sequence begins with a table, similar to the one below, which provides information and requirements specific to that section. The item number appearing after each piece of equipment refers to an entry in Table 1 Required Test Equipment. Immediately following the table, you will be given instructions for interconnecting the VX4801 under-test and for checking the performance parameters. Results may then be recorded on a photocopy of the Test Record on page A–23.

Digital Volt Meter (item 1) Loop-Back Cable Assembly (item 3)

Prerequisites All prerequisites listed on page A–20

This procedure assume that you will be using the National Instruments PC GPIB controller and software (NI-488.2M) configured as described in Table 3. In the test sequences, you will be instructed to issue Interface Bus Interactive Control (ibic) commands to set up the VX4801 under-test and other associated VXIbus test instruments. Please refer to the NI-488.2M User Manual for additional information. If you are using a different controller or software, simply substitute the equivalent commands.

VX4801 Programmable Digital I/O Module A–19

Equipment Requirements

Page 78 of the Tektronix VX4801 user manual — Equipment Required
Page 78 · cliquer pour agrandir
Page 78
Appendix EPerformance Verification

Prerequisites

The verification sequences in this procedure are valid when the following requirements are met:

The VX4801 module covers are in place and the module is installed in an approved VXIbus mainframe as described in Section 2 of the Operating Manual

The VX4801 has passed the power-on self test

The VX4801 is operating in an ambient environment as specified in Section 1 of the Operating Manual for a warm–up period of at least 10 minutes

Equipment Required

This Procedure uses traceable signal sources and measurement instruments. Table 1 lists the required equipment. You may use equipment other than the recommended examples if it meets the minimum requirements.

Table 1Required Test Equipment

Item Number and Description Minimum Requirements Example Purpose

1. Digital Volt Meter (DVM) 5-1/2 digit, 100 VDC range, accuracy > 0.002 %.

FLUKE 8842A Checking isolation impedance

2. Digital I/O Module 4 byte TTL/CMOS data I/O Tektronix VX4801 Checking external functions
3. Loop-Back Cable Assembly Male DB-50 Connector, two required (Tektronix part number 131-1344-00)

Assemble as shown in Figure 4

Checking TTL/CMOS Data I/O, Tri-State, and Hand- shake.

Male DB-25 Connectors, are required (Tektronix part number 131-0570-00)

26 AWG ribbon wire

A–20 VX4801 Programmable Digital I/O Module

Page 79 of the Tektronix VX4801 user manual — Prerequisites
Page 79 · cliquer pour agrandir
Page 79
Appendix EPerformance Verification
Tektronix VX4801 — Prerequisites diagram (page 79)
Fig. 70 · Prerequisites

length of interconnect wire between modules.

Figure 4Loop-Back Cable Assembly (View of Solder Side)

VX4801 Programmable Digital I/O Module A–21

Show 4 more labels / short text on this page
Byte 5 LSB · Byte 3 LSB · Byte 2 MSB · Allow approximately 6”
Page 80 of the Tektronix VX4801 user manual — Test System Configuration
Page 80 · cliquer pour agrandir
Page 80
Appendix EPerformance Verification

VX4801 Under-Test Configuration

In order to perform this procedure, the VX4801 under-test must be installed in an approved VXIbus system. At a minimum, the system must contain the elements listed in Table 2.

Table 2Elements of a Minimum VX4801 Under-Test System

Item Number and Description Minimum Requirements Example Purpose

1. VXIbus Mainframe Two available slot for VX4801 under-test and the VX4801 digital signal source (Slave) in addition to the Slot 0 controller

Tektronix VX1400A Provides power, cooling, and backplane for VXIbus modules

2. Slot 0 Controller Resource Mgr., Slot 0 Functions, IEEE 488 GPIB Interface

VX4521 Slot 0 Resource Mgr. Provides Slot 0 functions., Resource Mgr., and GPIB/ VXIbus interface

3. VXIbus System Controller VXIbus-Talker/Listener/Controller IBM 486 PC with National Instruments GPIB PC2A card & NI-488.2M software, GPIB cable (Tektronix P/N 012–0991-00)

Provides VXIbus command and response interface

4. VX4801 Under-Test Not applicable Not applicable Verify its performance
5. VX4801-Slave 4 byte TTL/CMOS I/O VX4801 Provides test signal I/O

Table 3 describes the VXIbus system configuration assumed in this procedure. If your configuration is different, you do not need to change it, just note that you will observe your device names and addresses in test sequences. (Note that no secondary addressing is assumed.)

Test System Configuration

Table 3Test System Configuration (Assumed)

GPIB Device Name VXI Slot

GPIB0 GPIB0 (PC card) NA 30

VX4521 VX4521 Slot 0 0D (hex) 13

VX4801 under-test VX4801 Slot 1 01 1

VX4801 slave slave Slot 2 02 2

A–22 VX4801 Programmable Digital I/O Module

VXIbus Logical Address · GPIB Primary Address · Device

Page 81 of the Tektronix VX4801 user manual — Test Record
Page 81 · cliquer pour agrandir
Page 81
Appendix EPerformance Verification

Test Record

Photocopy the Test Record, and use it to record the performance verification results for your module.

Table 4VX4801 Test Record
VX4801 Serial NumberTemperature and Relative Humidity:
Date of Last CalibrationVerification Performed by:
Certificate NumberDate of Verification:
Table 5VX4801 Performance Tests

VXIbus Interface Checks Logical Address, IEEE Address, Slot No., MFG., Model, etc.

Table Command Response 1st. Response

Preliminary Tests Self Test

TTL/CMOS I/O Data Bytes

Tri-State Control Signals Internal

Handshake Control Signals Transmit

VX4801 Programmable Digital I/O Module A–23

Show 6 more labels / short text on this page
2nd Response · 3rd Response · Passed Failed · Interrupt SRQ · External · Receive
Page 82 of the Tektronix VX4801 user manual — VXIbus Interface
Page 82 · cliquer pour agrandir
Page 82
Appendix EPerformance Verification

Self Test

The VX4801 includes a built-in self test function (BITE) which is automatically executed each time the power is turned on and when the Internal Self Test (S) command is issued. BITE uses internal routines and circuitry to confirm basic I/O functionality. No external test equipment is required.

During self test, all outputs are set to a high impedance (tri-state) mode and then internal loop-back circuitry and test patterns are used to verify all I/O channels.

In addition to BITE, front panel indicator lights display the current status of power, the assertion of SYSFAIL*, backplane cycles, data handshake signals, and individual I/O data bits for each byte. The Query command may also be used at any time during operation to determine the current state of the module.

Following the VXIbus system startup sequence, the green PWR light on the VX4801 front panel indicates that the self test has passed and that the +5 V power supply is operational. If the +5 V power supply fails, or its fuse opens, the PWR light will be off, the FAILED light will be on, and SYSFAIL* will be asserted indicating a module failure.

NOTE. If you experience an error indication from the Slot 0 Resource Manager, the VX4801-under-test, or other VXIbus module, investigate and correct the problem before proceeding. Common items to check are logical address conflicts (primary and secondary; see Table 3), breaks in the VXIbus daisy chain signals, improper seating of a module, loose GPIB cable, improperly set Slot 0 single- step switch, or loose or blown fuses.

Performance Verification Tests

The order of execution of this procedure has been chosen to minimize system setup and functional dependency. Because some tests rely on the success of their predecessors, it is recommended that you perform all sequences in order.

This sequence verifies that the VX4801 configures correctly and communicates properly with your GPIB system controller.

VXIbus Interface

No additional test equipment is required for this sequence.

Prerequisites All prerequisites listed on page A–20

A–24 VX4801 Programmable Digital I/O Module

Equipment Requirements

Page 83 of the Tektronix VX4801 user manual — Self Test
Page 83 · cliquer pour agrandir
Page 83
Appendix EPerformance Verification
1. To verify the system configuration, send the TABLE command to the Slot 0 Resource Manager and confirm the responses shown in Table 6. Your configuration may not be identical, but the responses should be similar.
Table 6VXIbus System Configuration

Command to Type Response to Verify

)+- ' . .

)+- '

)+- '

2. Verify the VX4801 VXIbus interrupt capability with the following steps:

a. Enable the generation of VXI Request True interrupt and force a VXIbus interrupt with an error condition with the following commands:

("/,- 0!% (Enable VXI Request True interrupt)

("/,- .0( (ObserveVX4801 ERR light is on)

VX4801 Programmable Digital I/O Module A–25

Show 5 more labels / short text on this page
("(# · ("&(*$ · ("/,- -!")% · (",$ · ("&(*$
Page 84 of the Tektronix VX4801 user manual — TTL/CMOS I/O
Page 84 · cliquer pour agrandir
Page 84
Appendix EPerformance Verification
(ObserveVX4521 Slot 0 indicates S in 2nd digit)

b. Check that the FAILED light on the VX4801-device-under-test is on and that the VX4521 displays an S in the second digit of the front panel indicating an SRQ pending.

c. With the following commands, perform a serial poll with the VX4801 and verify a response of 40 hexadecimal which indicates that it was the interrupting device. Also, verify that the VX4521 Slot 0 controller SRQ is no longer asserted. Finally, perform a second serial poll and observe a response of 0, indicating no interrupt pending:

(ObserveVX4521 no longer displays S)
(ObserveVX4801 response = 0; interrupt cleared)

d. Perform a Status Query (ASCII) and verify that the ERR light is off, and then read the error message:

(ObserveVX4801 ERR light is off)
(ObserveSYNTAX ERROR.. )

This test sequence verifies that each eight bit port (6) of the VX4801 can provide both active high and low TTL/CMOS inputs and outputs.

TTL/CMOS I/O

Loop-back assembly (item 3)

Prerequisites All prerequisites listed on page A–20

1. Attach the loop-back assembly as shown in Figure 4, which connects the odd bytes to the even bytes respectively (0 to 1, 2 to 3, 4 to 5).

A–26 VX4801 Programmable Digital I/O Module

Equipment Requirements

Page 85 of the Tektronix VX4801 user manual — TTL/CMOS I/O
Page 85 · cliquer pour agrandir
Page 85
Appendix EPerformance Verification
2. Perform a self test and query for any error codes (in ASCII format) with the VX4801 device-under-test and the Slave VX4801:
(ObserveNO ERRORS)
(ObserveNO ERRORS)
3. Verify the odd byte data inputs and the even byte data outputs with the following steps:

a. Reset the VX4801 to its power-up state and then set its mode for the odd bytes (1, 3, 5) to be active low inputs, for the even bytes (0, 2, 4) to be active high outputs loaded with a Load Output value of 55, and set the tri-state function to be inactive (* => all bytes, i => inactive):

b. Perform an input of all bytes and verify a response of 55AA55AA55AA:

(Observe55AA55AA55AA)

c. Repeat the previous test with the logic sense reversed; i.e. odd bytes (1, 3, 5) set to active high and the even bytes set to active low. Verify the complementary response:

(ObserveAA55AA55AA55)

VX4801 Programmable Digital I/O Module A–27

Show 7 more labels / short text on this page
· · · · · ·
Page 86 of the Tektronix VX4801 user manual — Tri-State Function
Page 86 · cliquer pour agrandir
Page 86
Appendix EPerformance Verification

4. To verify the even byte data inputs and the odd byte data outputs, reset the VX4801 to its power-up state and then set its mode for the even bytes (0, 2, 4) to be active low inputs, for the odd bytes (1, 3, 5) to be active high outputs loaded with a Load Output value of 55, and set the tri-state function to be inactive. Perform an input of all bytes and verify an AA55AA55AA55 response and then reverse the logic sense of the even and odd bytes and verify the complementary response of 55AA55AA55:

(ObserveAA55AA55AA55)

(Observe55AA55AA55AA)

This test sequence verifies that the internal tri-state commands and the external tri-state signals are functioning properly for each I/O byte.

Tri-State Function

Loop-back assembly (item 3)

Prerequisites All prerequisites listed on page A–20

1. Install the loop-back assembly on the VX4801 under-test and the slave VX4801 as shown in Figure 4.
2. Verify the internal tri-state command with the following steps:

a. Reset the VX4801 to its power-on default state (all bytes initially tri-stated). Then set its mode for the odd bytes to be active high inputs and for even bytes to be active high outputs with a Load Output value of 00. Finally, leave the even (output) bytes tri-stated, but set the odd (input) byte tri-states to be inactivate. Perform an input of all bytes and verify that the even bytes are in tri-state mode and not driving the odd byte inputs (odd inputs not pulled low):

A–28 VX4801 Programmable Digital I/O Module

Show 4 more labels / short text on this page
· · Equipment Requirements ·
Page 87 of the Tektronix VX4801 user manual — Tri-State Function
Page 87 · cliquer pour agrandir
Page 87
Appendix EPerformance Verification

(Observeresponse of 00FF00FF00FF)

b. Repeat the above test, this time with the even bytes set as inputs and the odd bytes set as tri-stated outputs. Perform an input of all bytes and verify that the even bytes are in tri-state mode and not driving the even byte inputs (even inputs not pulled low):

(Observeresponse of FF00FF00FF00)
3. Verify the external tri-state signals with the following steps:

a. Set up the Slave VX4801 to disable the external tri-state signals (ETS0 - ETS5) to the VX4801 device-under-test:

b. Set up the VX4801-device-under-test for odd bytes to be inputs, for even bytes to be outputs with a Load Output value of 00, and for internal tri-state to be inactive for all bytes. Read all bytes and verify the 00 output value on all bytes (internal tri-state inactive):

(Observeresponse of 000000000000)

c. Set the Slave to assert the external tri-state signals to the even bytes of the VX4801 and verify a response of 00FF00FF00FF:

VX4801 Programmable Digital I/O Module A–29

Show 8 more labels / short text on this page
· · · · · · ·
Page 88 of the Tektronix VX4801 user manual — Tri-State Function
Page 88 · cliquer pour agrandir
Page 88
Appendix EPerformance Verification
(Observeresponse of 00FF00FF00FF)

d. Set the Slave to un-assert external tri-state signals. Then set the VX4801 for the odd bytes to be inputs, for the even bytes to be outputs with a Load Output value of 00, and for internal tri-state to be inactive for all bytes. Read all bytes and verify the 00 output value on all bytes (internal tri-state inactive):

(Observeresponse of 000000000000)

e. Set the Slave to assert the external tri-state signals to the odd bytes of the VX4801 and verify a response of FF00FF00FF00:

(Observeresponse of FF00FF00FF00)

A–30 VX4801 Programmable Digital I/O Module

Show 9 more labels / short text on this page
· · · · · · · ·
Page 89 of the Tektronix VX4801 user manual — Check Handshake
Page 89 · cliquer pour agrandir
Page 89
Appendix EPerformance Verification

This test sequence verifies that data can be transferred to and from the VX4801 using the four handshake signal lines Data Ready (DRD), Data Acknowledge (DAK), Ready for Data (RFD), and Data Available (DAV).

Check Handshake

Loop-back assembly (item 3)

Prerequisites All prerequisites listed on page A–20

1. Connect the loop-back assembly as shown in figure 4.
2. Using the following steps, verify a data byte transfer 55 hexadecimal from the VX4801 (byte 5) to the Slave (byte 3) using the Ready for Data (RFD) from the Slave and the Data Valid (DAV) from the VX4801:

a. Set the VX4801 for a positive edge handshake, to update the output data on receipt of a Ready For Data (RFD) strobe, to update the input data on receipt of a Data Ready (DRD) strobe, and for byte 5 to be an active high output, initialized with a Load Output data value of 55 hexadecimal and with its tri-state inactive:

$ ! " !

b. Set the Slave mode for byte 2 to be an active high output (for assertion of RFD), for bytes 1 and 3 to be active high inputs (byte 1 to detect DAV and byte 3 to input data), and for all tri-states to be inactive:

$ ! !

c. Set the Slave to input byte 1 (with all bits masked except bit 1) and byte 3 and verify that DAV is un-asserted (i.e. byte 1, bit 0 = 0) and consequently, that there is no data (byte 3 = 00):

$ !

(Observe0000 and VX4801 DAV light off)

VX4801 Programmable Digital I/O Module A–31

Equipment Requirements · ! · ! #

Page 90 of the Tektronix VX4801 user manual — Check Handshake
Page 90 · cliquer pour agrandir
Page 90
Appendix EPerformance Verification

d. Set the Slave to initialize byte 2 with an Output Data value of 01 (asserts RFD to the VX4801) and verify that the VX4801 correspondingly asserts DAV:

(ObserveVX4801 DAV light on)

e. Set the Slave to input bytes 1 and 3 and verify receipt of DAV (byte 1 bit 1 = 1) and data (byte 3 = 55):

(Observe0155 return value)
3. Using the following steps, verify a data byte transfer (AA hex) from the Slave (byte 5) to the VX4801 (byte 3) using the Data Ready (DRD) and Data Acknowledge (DAK) handshake lines:

a. Set the Slave mode for byte 2 and 3 to be active high outputs, with byte 3 initialized to a Load Output data value of AA, and set all tri-states to be inactive:

b. Set the VX4801 for a positive edge handshake, to update the output date on receipt of a DRD strobe, to update the input data on receipt of a DRD strobe, and for byte 5 to be an active high input with its tri-state inactive (note that after the data is strobed in with DRD from the slave, the VX4801 will in turn generate the DAK, but only after the controller has read the data byte):

r;p*+;urd;m5ih;t5i

c. Send a byte 5 input command to the VX4801, and verify that a response of N, indicating that the module is waiting for a DRD strobe:

(Observe N; waiting for DRD strobe)

d. Set the Slave to send a DRD strobe (byte 2, bit 2) and then verify that the VX4801 DAK light is off:

(Send DRD to VX4801; observe DAK light off)

A–32 VX4801 Programmable Digital I/O Module

Show 4 more labels / short text on this page
· · ·
Page 91 of the Tektronix VX4801 user manual — Check Handshake
Page 91 · cliquer pour agrandir
Page 91
Appendix EPerformance Verification

e. Send a byte 5 input command to the VX4801 and verify that the DAK light is on. Then read the data, observe a response of AA, perform a second read and observe that the VX4801 is again waiting for a DRD strobe:

(Observe VX4801 DAK light off)

(Observe DAK light on)

(Observe AA response)

(Observe N response, indicating waiting for DRD)

This completes the VX4801 verification procedure.

VX4801 Programmable Digital I/O Module A–33

Poser une question sur : Tektronix VX4801

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Tektronix VX4801

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Tektronix VX4801 manuel PDF

91 pages·2.3 MB·Système de soudage·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…