© 2014 Stanley Black & Decker , Inc. New Britain, CT 06053 U.S.A. 62379 8/2014 V er . 4 USER MANUAL Safety , Operation and Maintenance CD12 Hydraulic Core Drill.
.
CD12 User Manual ◄ 3 SERVICING: This manual contains safety , operation, and routine maintenance instructions. Stanley Hydraulic T ools recommends that servicing of hydraulic tools, other than routine maintenance, must be performed by an authorized and certied dealer .
4 ► CD12 User Manual Always observe safety symbols. They are included for your safety and for the protection of the tool. LOCAL SAFETY REGULA TIONS Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and mainte- nance personnel.
CD12 User Manual ◄ 5 T ool operators and maintenance personnel must always comply with the safety precautions given in this manual, and on the stickers and tags attached to or on the tool and hose(s). These safety precautions are for your safety . Review them carefully before operating the tool or performing any maintenance or repairs.
6 ► CD12 User Manual SAFETY T AG P/N 15875 (Shown smaller then actual size) DANGER DANGER READ OPERA TION MANUAL AND SAFETY INSTRUCTIONS FOR THIS TOOL BEFORE USING IT . USE ONL Y P ARTS AND REP AIR PROCEDURES APPROVED BY ST ANLEY AND DESCRIBED IN THE OPERA TION MANUAL.
CD12 User Manual ◄ 7 The rated working pressure of the hydraulic hose must be equal to or higher than the relief valve setting on the hy- draulic system. There are three types of hydraulic hose that meet this requirement and are authorized for use with Stanley Hydraulic T ools.
8 ► CD12 User Manual Oil Flow Hose Lengths Inside Diameter USE ( Press/Return) Min. Working Pressure GPM LPM FEET METERS INCH MM PSI BAR Certied Non-Conductive Hose - Fiber Braid - for Utility Bu.
CD12 User Manual ◄ 9 Flow Range Nominal Operating Pressure (at the power supply outlet) System relief valve setting (at the power supply outlet) Maximum back pressure (at tool end of the return hose) Measured at a max. uid viscosity of: (at min. operating temperature) T emperature: Sufcient heat rejection capacity to limit max.
10 ► CD12 User Manual GENERAL OPERA TION The tool comes with a set of accessories which may be customized by each purchaser , so as to facilitate per- formance of all work occurring within the scope of his specic application. T ools included are for mounting and dismounting.
CD12 User Manual ◄ 1 1 DRILLING WITH CD12 ANCHOR ST AND The anchor stand may be used with a vacuum pump for a vacuum hold down or with a concrete anchor screw to hold the stand in place while drilling. The standard ar- rangement of the anchor stand is for use with a vacuum pump.
12 ► CD12 User Manual 12. NO TICE Manually screw the corresponding drill bit from below onto the drill bit adapter . Manual tightening is sufcient because the drill bit will automatically tighten further during the drilling operation. Connect the core drill to a water supply .
CD12 User Manual ◄ 13 ANCHOR ST AND TROUBLESHOOTING Symptom Cause Solution The Anchor Stand will not hold a vacuum. Debris under the base gasket is preventing a good seal. Clean the surface on which the gasket must seal. Debris between the base gasket and the base.
14 ► CD12 User Manual • Make sure all couplers are wiped clean before con- nection. • The hydraulic circuit control valve must be in the OFF position when coupling or uncoupling hydrau- lic tools. Failure to do so may result in damage to the quick couplers and cause overheating of the hy- draulic system.
CD12 User Manual ◄ 15 When diagnosing faults in operation of the grinder , always check that the hydraulic power source is supplying the correct hydraulic ow and pressure to the grinder as listed in the table. Use a owmeter known to be accurate.
16 ► CD12 User Manual Problem Cause Solution Fluid gets too hot. Circuit relief set too low . Adjust relief valve to 2100-2250/145- 155 bar . T oo much uid going through tool. Adjust ow for 6 gpm/23 lpm maximum. Circuit has contaminants that have caused wear and high heat genera- tion.
CD12 User Manual ◄ 17 System T ype .................................................................................................................................... HTMA T ype II OC Flow Range .....................................................
18 ► CD12 User Manual CD12 P ARTS ILLUSTRA TION.
CD12 User Manual ◄ 19 ITEM P ART NO. QTY DESCRIPTION 6531 1 MOTOR ASSEMBL Y 101 65207 1 MOT OR HOUSING 102 41254 1 OUTPUT SHAFT 103 41255 1 SPUR GEAR 104 41256 1 SHAFT SEALING 105 41257 1 SNAP RING .
20 ► CD12 User Manual CD12 ANCHOR ST AND ILLUSTRA TION.
CD12 User Manual ◄ 21 ITEM P ART NO. QTY DESCRIPTION 1 65214 1 HANDLE 2 65215 1 ST OP PLA TE 3 65216 2 HSH CAPSCREW 4 65217 4 HSFH SCREW 5 65218 1 CLAMP PLA TE 6 65219 1 DRILL ST AND COLUMN 7 65220 .
Stanley Hydraulic T ools 3810 SE Naef Road Milwaukie, Oregon 97267-5698 USA (503) 659-5660 / Fax (503) 652-1780 www .stanleyhydraulics.com.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Stanley Black & Decker CD12 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Stanley Black & Decker CD12 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Stanley Black & Decker CD12, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Stanley Black & Decker CD12 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Stanley Black & Decker CD12, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Stanley Black & Decker CD12.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Stanley Black & Decker CD12. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Stanley Black & Decker CD12 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.