Manuel d'utilisation / d'entretien du produit BCM 2604 du fabricant Baracoda
Aller à la page of 49
The bluetooth name and Bluetooth registered trademarks are owned by Bluetooth SIG, Inc., and are used by B aracoda under license. The Baracoda names and Baracoda trademarks are own by Baracoda. All specifi cation are subject to c hange without notice - Non contractual pictures © Baracoda - All rights reserved Baracoda, Inc.
BCM2604-F Programming guide This document is to be us ed with t he following Baracoda Barco de Scanners: BCM2604-F Important notice: Every effort is made to ensure the accuracy of our product informat.
BCM2604-F Programming Guide 1 RESET ALL PARAMETERS ...................................................................................................................... 4 2 OUTPUT ......................................................................
3.9 IATA C ODE 2 OF 5 ............................................................................................................................ 21 3.9.1 IATA Code 2 of 5 Message Length ...............................................................
3.24 C ODE 49 ............................................................................................................................... ............ 34 3.24.1 Code 49 Message L ength ..............................................................
2 Output 2.1 Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turnin g this option off, only turns off the beeper response to a g ood read indication. All e rror and menu beeps are still audible. Default = On. 2.
2.5 Number of Beeps – Good Read The number of beeps of a good read can be programmed fr o m 1 – 3 (m a xi mu m 3 ). T he sa me n u m b er of beeps will be applied to the beeper and LED in resp onse to a good read. For example, if you program this option to have two beeps, there will be two beeps and two LED flashes in response to a good read.
2.8 Centering Use Centering to narrow the imager’s field of view to make sure the imager reads only those bar codes intended by the user. For instance, if multip le codes are placed closel y together, centering will insure that only the desired codes are re ad.
2.9 Decode Search Mode There are three selectable decode (scanning) modes: Full Omnidirectional - Searches for bar code featur es be ginning at the center of an image, and searches to the image ’ s limits. This mode reads all symbologie s , in any orientation.
This programming selection allows you to progr am the Imager to output data (when scanning more than one symbol) in whatever order your application requires, re gardless of the order in which the bar codes are scanned. Re ading the Default Sequence sy mbol programs the Imager to the Universal values, shown below.
You would set up the sequence editor with the following command line: SEQBLK62999941FF6A 999942FF6999994 3FF The breakdown of the command line is shown below: SEQBLKsequence editor start command 62 co.
2.12 No Read With No Read turned On, the Imager notifies you if a code c a nnot be read. If using a Quick*View Scan Data Window, an “NR” appears when a co de cannot be read.
2.15 Working Orientation Rotate Counterclock wise 90 ° 2.16 Prefix Suffix It is of course possible to add a suffix/prefix but not via this programming guide. It is only possible sending commands via Bluetooth. Please refer to the Bar acodaManager documentation for further information.
3 Symbologies This programming section contains the following men u selections Linear barcodes Codabar, Code 39, Interleaved 2 of 5, Code 93, EAN, Code 2 of 5, IATA Code 2 of 5, Matrix 2 of 5, Code 11.
EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters.
No Check Character indicates that the imager reads and transmits bar code dat a with or without a check character. When Check Character is set to Validat e and Transmit, the imager will only read Codabar bar codes printed with a check character, and will transmit this character at the end of the sc anned data.
Maximum Default = 60. 3.5 Code 39 < Default All Code 39 Settings > 3.5.1 Code 39 Start/Stop C haracters Start/Stop characters identify the leadin g and tra iling ends o f the bar code. You may either transmit, or not transmit Start/Stop charact ers.
3.5.3 Code 39 Me ssage Length Scan the bar codes below to change the message length. Refer to Message Length Description (chapt 3.2) for addition al info rmation.
NUL %U DLE $P SP SPA CE 0 0 @ %V P P ‘ % W p +P SOH $A DC 1 $Q ! /A 1 1 A A Q Q a +A q +Q STX $B DC2 $R “ /B 2 2 B B R R b +B r +R ETX $C DC3 $S # /C 3 3 C C S S c +C s +S EOT $D DC4 $T $ /D 4 4 D.
Interleaved 2 of 5 3.6.1 Check Digit No Check Digit indicates that the imager reads an d transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Tran smit, the unit only reads Interleaved 2 of 5 bar codes printed with a check digit, but will not tr ansmit the check digit with the scanned data.
3.7.1 Code 93 Me ssage Length Scan the bar codes below to change the message length. Refer to Message Length Description (chapt 3.2) for addition al info rmation. Minimum and Maximum length s = 0-80. Minimum Default = 0, Maximum Default = 80. Maximum Messa g e Len g th 3.
Maximum Message Length 3.9 IATA Code 2 of 5 <Default All Code IATA 2 of 5 Settings> I ATA C ode 2 o f 5 3.9.1 IATA Cod e 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (chapt 3.2) for addition al info rmation.
3.11 Code 11 <Default All Code 11 Settings> Code 11 3.11.1 Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes. Default = Two Check Digits. 3.11.2 Code 11 Me ssage Length Scan the bar codes below to change the message length.
space-efficient design, 3) a variation of Code 128 that supports concatenation of neighboring symbols, and 4) the standard layo ut for bar codes on a blood product label. Use the bar code s below to turn concatenation on or off. Default=Off. 3.12.2 Code 128 M essage Lengt h Scan the bar codes below to change the message length.
Original Telepen Output 3.13.2 Telepen Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (chapt 3.2) for addition al info rmation. Minimum and Maximum length s = 1-60. Minimum Default = 1, Maximum Default = 60.
3.14.3 UPC-A Addenda 3.14.4 UPC-A Addenda Required When Required is scanned, the imager will only re ad UPC-A bar codes that h ave addenda. You must then turn on a 2 or 5 digit addenda liste d on page 820.
3.14.7 UPC-E0 Most U.P.C. bar codes lead with the 0 n umber system. For these codes, u se the UPC-E0 selection. If you need to read codes that lead with t he 1 number system, use UPC-E1. De fault = On. 3.14.8 UPC-E0 Expand UPC-EO expands the UPC-E code to the 12 di git, UPC-A format.
3.14.12 UPC-E0 Number System The numeric system digit of a U.P.C. symbol is no rmally tran smitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. 3.14.13 UPC-E0 Addenda This selection adds 2 or 5 digits to the end of al l scanned UPC-E data.
3.15.1 EAN/JAN-13 Check Digit This selection allows you to speci fy whether the check digit should be transmitted at the end of the scanned data or not. Default = On. 3.15.2 EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of al l scanned EAN/JAN-13 data.
3.15.5 ISBN Trans late This selection causes EAN-13 Bookla nd symbols to be translated in to their equivalent ISBN number format. Default = Off. 3.16 EAN/JAN-8 Defaults All Settings EAN/JAN-8 EAN/JA N - 8 3.
3.16.3 EAN/JAN-8 A ddenda Required When Addenda Required is set to on, the imager will only read EAN/JAN- 8 bar codes that have addenda. Default = Not Required. 3.16.4 EAN/JAN-8 Addenda Separator When this feature is on, there is a spac e between t he data from the bar code and the data from the addenda.
3.17.2 MSI Mess age Length Scan the bar codes below to change the message length. Refer to Message Length Description (chapt 3.2) for addition al info rmation. Minimum and Maximum length s = 4-48. Minimum Default = 4, Maximum Default = 48. 3.18 Plessey Code 3.
3.19.2 RSS Limited < Default All RSS Li mited Settings > 3.19.3 RSS Expand ed < Default All RSS Expanded Settings > 3.19.4 RSS Expand ed Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (chapt 3.
You have to have PosiCode A and B on to read any of the PosiCode symbolo gies. A and B Limited B On (Limited A Off) 3.20.2 PosiCode Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (chapt 3.2) for addition al info rmation.
Minimum Message Length Maximum Message Length 3.23 Code 16K <Default All Code 16K Settings 3.23.1 Code 16K M essage Lengt h Scan the bar codes below to change the message length. Refer to Message Length Description (chapt 3.2) for addition al inform ation.
3.25 PDF417 Minimum Message Length 3.25.2 MicroPDF 417 < Default All MicroPDF417 Settings > Maximum Message Length 3.25.3 MicroPDF 417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (chapt 3.
3.26 EAN~UCC Composite Codes Linear codes are combined with a unique 2D comp osite component to form a new class called EAN~UCC Composite symbology. EAN~UCC Compos ite symbologies allow for the co-existence of symbologies already in use.
3.27 TCIF Linked Code 39 (TLC39) This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component. All bar code readers are capable of reading the Code 39 linear component. The MicroPDF417 component can only be decoded if TLC39 On is selected.
3.31 Canadian Post 3.32 Kix (Netherlands) Post Note: Kix code can misread when scanned sid eways or upside down. Use Working Orientation , if your Kix codes will not usually be presented upright to the scanner. 3.33 Australian Post 3.34 Japanese Post 3.
3.35.1 China Post Message Lengt h Scan the bar codes below to change the message length. Refer to Message Length Description (chapt 3.2) for addition al info rmation. Minimum and Maximum length s = 2-80. Minimum Default = 4, Maximum Default = 80. M a x i m u m m e s s a g e l e n g t h 3.
3.38 Data Matrix <Default All Matrix 2 of 5 Sett ings> 3.38.1 Data Matrix Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (chapt 3.2) for addition al info rmation. Minimum and Maximum leng ths = 1-1500.
3.40 Aztec Code < Default All Aztec Code Settings > 3.40.1 Aztec Co de Mes sage Le ngth Scan the bar codes below to change the message length. Refer to Message Length Description (chapt 3.2) for addition al info rmation. Minimum and Maximum leng ths = 1-3750.
Appendix A: Symbololy Chart Symbology AIM ID Possib le AIM ID Modifiers ( m ) Code ID (hex) All Symbologies (0x99) Australian P ost ]X0 A (0x41) Aztec Code ]z m 0-9, A-C z (0x7A) British Post ]X0 B (0.
Trioptic Code ]X0 = (0x3D) UCC/EAN-128 ]C1 I (0x49) UPC-A ]E0 c (0x63) UPC-A with Extend ed Coupon Code ]E3 c (0x63) UPC-E ]E0 E (0x45) VeriCode* ]X0 v (0x76) * Only available by special order.
Appendix B: ASCII Conversion Chart Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char 0 00 NUL 32 20 64 40 @ 96 60 ‘ 1 01 SOH 33 21 ! 65 41 A 97 61 a 2 02 STX 34 22 “ 66 42 B 98 62 b 3 03 ETX 35 .
Dec. Hex Cha r Dec. Hex Char Dec. Hex Char Dec. Hex Char 128 80 € 160 A0 192 C0 À 224 E0 à 129 81 161 A1 ¡ 193 C1 Á 225 E1 á 130 82 ‚ 162 A2 ¢ 194 C2 Â 226 E2 â 131 83 ƒ 163 A3 £ 195 C3 .
Appendix C: Code Page Mapping of Printed Bar Codes Co de p age s d e f i ne th e m ap pi n g of ch ara ct e r co de s to characters. If the data rec eive d doe s n ot dis play wi th t he p ro pe r ch ar ac te rs , it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting.
APPENDIX E : Programming Chart 47 a e d g c h t l Discard Save r A C B F E D.
Note: If you make an error while scan ning the le tte s or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Sav e. r 48 0 1 2 3 Discard 9 8 7 6 5 4.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Baracoda BCM 2604 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Baracoda BCM 2604 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Baracoda BCM 2604, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Baracoda BCM 2604 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Baracoda BCM 2604, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Baracoda BCM 2604.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Baracoda BCM 2604. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Baracoda BCM 2604 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.