Manuel d'utilisation / d'entretien du produit 72A-196BAREM Series du fabricant Spectrum Brands
Aller à la page of 26
72A-196BAREM Series 72A-190BQREM Series Installation and Operation Manual 3-Phase Power Monitoring and Distribution Unit June 2, 2008 Rev-01 27-0027-01 1 1.
Installation and Operation Manual SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Date: 6/02/2008 2 27-0027-01 1 1 Contents I ntroduction & Safety Information .............................................. 3 T echnical Specications ...........
Installation and Operation Manual Date: 6/02/2008 3 27-0027-01 1 1 SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Introduction & Safety Information The Spectrum Control PDU is an AC power distribution unit designed to distribute power for up to eighteen (18) AC loads.
Installation and Operation Manual SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Date: 6/02/2008 4 27-0027-01 1 1 T echnicalSpecications Global Domestic Power Entry Connector IEC 309, 4pole, 5.
Installation and Operation Manual Date: 6/02/2008 5 27-0027-01 1 1 SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Declaration of Conformity Manufacturer ’ s Name: Manufacturer ’ s Address: Decla.
Installation and Operation Manual SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Date: 6/02/2008 6 27-0027-01 1 1 Connections and Installation Operating Environment • Locate PDU in dry area. • Rack Mount in equipment rack using mounting brackets.
Installation and Operation Manual Date: 6/02/2008 7 27-0027-01 1 1 SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Electrical Connections • Depress rocker handle of all circuit breakers to “off” position.
Installation and Operation Manual SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Date: 6/02/2008 8 27-0027-01 1 1 LAN Module and Communications RJ45 LAN Connection LAN Module Interface The LAN Module provides an interface between a computer network and the power distribution unit using the front RJ-45 jack.
Installation and Operation Manual Date: 6/02/2008 9 27-0027-01 1 1 SCI P/N: 72A-196BAREM Series 72A-190BQREM Series The LAN module consists of integrated hardware and a network agent softwareprogram.
Installation and Operation Manual SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Date: 6/02/2008 10 27-0027-01 1 1 Connections and Installation The discovery tool “digi_dev_disc.exe” has the following: 1.“CongureNetworkSettings”istoconguretheIP/Subnet/Gateway .
Installation and Operation Manual Date: 6/02/2008 1 1 27-0027-01 1 1 SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Connections and Installation T elnet Conguration Password SettingtheT elnetcongurationpasswordpreventsunauthorizedaccess of the setup menu via a T elnet connection to port 9999.
Installation and Operation Manual SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Date: 6/02/2008 12 27-0027-01 1 1 Connections and Installation Set PDU and LAN Module to Factory Defaults Menu option 8 restores all PDU and LAN module defaults back to the factory settings.
Installation and Operation Manual Date: 6/02/2008 13 27-0027-01 1 1 SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Connections and Installation Exit Conguration Mode Select9toexitthecongurationmodewithoutsavinganychanges,or select 10 to exit and save all changes.
Installation and Operation Manual SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Date: 6/02/2008 14 27-0027-01 1 1 Operational Control of PDU Front Panel Menu Theunit’sLCDisusedtomonitorincomingpowerandcongurethe software.
Installation and Operation Manual Date: 6/02/2008 15 27-0027-01 1 1 SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Operational Control of PDU PEAKS - MAX, MIN, RESET Selecting PEAKS in the menu system allows the user to view the maximum and minimum values that have been recorded for both voltage and current for each distribution bank.
Installation and Operation Manual SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Date: 6/02/2008 16 27-0027-01 1 1 CONFIG - CYCLE TIME The CYCLE TIME parameter sets the amount of time to wait before displaying the next bank measurement. The parameter can be set to F AST , MEDIUM, or SLOW .
Installation and Operation Manual Date: 6/02/2008 17 27-0027-01 1 1 SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Networking Functions The PDU LAN Port supports the T elnet and SNMP networking functions, which allow remote monitoring through the network environment.
Installation and Operation Manual SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Date: 6/02/2008 18 27-0027-01 1 1 telnet <IP Address> 10001 [space before and after address] T able 1 List of Commands: Command Description Response @AACK Alarm Acknowledgement #AACK @SYSF Save settings to EEPROM #SYSF OK @BNKV A,? V oltage Bank A #BNKV 120.
Installation and Operation Manual Date: 6/02/2008 19 27-0027-01 1 1 SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Networking Functions @BULC B,? Read High Threshold Current Bank B #BULC 22.5 @BULC C,? Read High Threshold Current Bank C #BULC 22.5 @BULC T ,? Read High Threshold Current Bank T #BULC 77.
Installation and Operation Manual SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Date: 6/02/2008 20 27-0027-01 1 1 Networking Functions Simple Network Management Protocol (SNMP) An SNMP-managed network consists of three key components: 1. Managed devices 2.
Installation and Operation Manual Date: 6/02/2008 21 27-0027-01 1 1 SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Networking Functions Interactions between the NMS and managed devices can be any of four different types of commands: reads, writes, traversal operations, and traps.
Installation and Operation Manual SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Date: 6/02/2008 22 27-0027-01 1 1 MAXandMINdataeldsarecalculatedbythePDU. T oresetaMAXeld,writea“0”(zero)tothedatalocation.
Installation and Operation Manual Date: 6/02/2008 23 27-0027-01 1 1 SCI P/N: 72A-196BAREM Series 72A-190BQREM Series SNMP v2 Functions SNMP v2 Functions V ariables SNMP v2 MIB V oltage Bank A READ &am.
Installation and Operation Manual SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Date: 6/02/2008 24 27-0027-01 1 1 Networking Functions This section addresses the loading and compiling of MIBS into Network Management Systems (NMS). Alternatively , you can consult the docu- mentation of other NMS on MIB loading and compilation.
Installation and Operation Manual Date: 6/02/2008 25 27-0027-01 1 1 SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Maintenance & W arranty Maintenance and Replacement parts There are no user serviceable parts inside the PDU. In the event there is an electronic problem with the unit, please contact the factory .
Installation and Operation Manual SCI P/N: 72A-196BAREM Series 72A-190BQREM Series Date: 6/02/2008 26 27-0027-01 1 1 PDU Front Panel IEC C13 Outlets 20A Circuit Breakers.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Spectrum Brands 72A-196BAREM Series c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Spectrum Brands 72A-196BAREM Series - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Spectrum Brands 72A-196BAREM Series, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Spectrum Brands 72A-196BAREM Series va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Spectrum Brands 72A-196BAREM Series, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Spectrum Brands 72A-196BAREM Series.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Spectrum Brands 72A-196BAREM Series. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Spectrum Brands 72A-196BAREM Series ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.