Manuel d'utilisation / d'entretien du produit ER12550NL du fabricant Smeg
Aller à la page of 15
Contents 18 1. INSTRUCTION S FOR SAF E AND PROP ER USE _______________ 19 2. POSIT IONING OF HOB ____________________________________ 21 3. ELECT RICAL CON NECTIO N _______________________________ 22 4. GAS CO NNECTION _______________________________________ 23 5.
Introduction 19 1. INSTR UCTIONS FOR SAFE AND PR OPER USE THIS MAN UAL I S AN INTEGR AL PART O F THE APPLIAN CE AN D THEREFOR E MUS T BE KEPT IN ITS ENT IRETY AND IN AN AC CESSIBL E PLACE FOR THE W HOLE WOR KING L IFE OF TH E COO KING HOB. WE ADVISE READIN G THIS M ANU AL AND ALL THE IN STRU CTIONS THERE IN BEFORE U SING TH E COOKIN G HOB.
Introduction 20 THE IDE NTIFICATION PLAT E, WITH TECHNI CAL DATA, SERIA L NUMBER AND M ARKIN G IS C LEARL Y VISI BLE UND ER TH E CASIN G. THE PLATE ON THE CAS ING MUST NOT BE REMOVED. BEFORE C ONNECT ING THE D EVICE, M AKE SURE TH AT IT H AS BEEN REGULAT ED FOR TH E TYP E OF GA S THAT W ILL FEED I T, CH ECKING THE LABE L UNDER THE CASING.
Instructions for th e installer 21 2. POSITIONING OF HO B The followi ng operation r equir es building and/or carpen try work s o must be carried out by a compete nt trade sman. Installation can be c arried out on var ious materi als such as masonry , metal, sol id wood or plastic laminate d wood a s long as they ar e heat resistant (T 90°C).
Instructions for th e installer 22 3. ELECTRICAL CONNECTION Make sure t hat the vol tage an d capacity of t he power line co nform to the data shown on the p late located under th e casing.
Instructions for th e installer 23 4. GAS CONNECTION Connectio n to the gas mains may be made with a rigid copper pipe or with a flexible pi pe and conf orming to t he provis ions defin ed by sta ndard regulations in force . To facilitate connectio n, fitting A on the rear of th e appliance m ay be adjusted l aterally.
Instructions for th e installer 24 4.1 Con nection to LPG Use a pre ssure regula tor and m ake the conn ection to t he ta nk accordi ng to the provision s of standards regulations in force. M ake sure that feed pressure co nforms to t he lev els show n in the t able in p aragrap h “5.
Instructions for th e installer 25 5. AD APT A TION T O DIFFERENT TYPES OF GAS Before performin g any cleaning or mai ntenance work, detach the appliance from the electrical sock et. The hob has been in spected for G 20 (2H) natural gas at a pressure of 20 mbar.
Instructions for th e installer 26 5.2 Regulat ion for L PG Loosen screw A and push support B a ll the way. Us e a double he ad wrench to remov e nozzle C and ass emble the suit able one, followin g the instruct ions indicated i n the reference ch arts, with respe ct to the type of gas to us e.
Instructions for th e installer 27 5.3 Regulation for natural gas The hob has been in spected for G 20 (2H) natural gas at a pressure of 20 mbar. To allow t he unit to work wit h this t ype of ga s, perform the same operations de scribe d in paragraph “5.
Instructions for th e installer 28 6. FINAL OPERA TIONS Having carri ed out the above adju stments, reassem ble the applian ce following, b ackwards, the i nstruction s in paragraph “5.1 R emoving the hob”. 6.1 Regulat ion of min imum fo r natural g as Replace the component s on the burner and slide the knobs o n the gas ta p pins.
Instructions for th e installer 29 6.3 Arrangement of burners on hob BURNERS 1. Auxiliar y 2. Triple crown 3. Double crown 6.4 Lubrication of gas taps After a while, the gas tap may becom e hard to turn or lock. If this happens, it has to b e cleaned inside an d re-greased.
Instructions for th e user 30 7. USING THE HOB Make sure that th e flame-baffl e crowns, the cap s and the grid have b een assembled corre ctly. Grid A (supplied) sho uld be used for "woks" (Chinese p ots). Adapter B (su pplied) is to be used f or small vessels.
Instructions for th e user 31 7.3 Diameter of containers BURNERS 1. Auxiliar y 2. Triple crown 3. Double crown Ø min. and max. (in cm) 7-18 22-26 12-34 8. CLEANING AND MAINTENANCE Before any intervention, disconnect the power supply of the device. 8.
Instructions for th e user 32 8.2 Cleaning of cooking hob components Grids, caps , flame cap crowns and burner s can be removed for ea se of cleani ng. Wash t hem in warm water using a non-abrasi ve deterge nt, taking care to remove all tough s pots. Before rem ounting, allow the compone nts to fully dry o ut .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Smeg ER12550NL c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Smeg ER12550NL - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Smeg ER12550NL, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Smeg ER12550NL va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Smeg ER12550NL, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Smeg ER12550NL.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Smeg ER12550NL. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Smeg ER12550NL ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.