INSTALLATION GUIDE

AXIS P12 Network Camera Series

ENGLISH DEUTSCH ITALIANO ESPAÑOL

AXIS P1204 Network Camera

FRAN Ç AIS

AXIS P1214 Network Camera

AXIS P1214-E Network Camera

AXIS P1224-E Network Camera

Page 2 of the Axis Communications P1214 user manual
Page 2 · cliquer pour agrandir
Page 2
  • About this Document This document includes instructions for installing AXIS P12 Network Camera series on your network. Previous experience of networking will be beneficial when installing the product. Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before using this product for surveillance purposes. This product includes one (1) H.264 decoder license. To purchase further licenses, contact your reseller. Trademark Acknowledgments Apple, Boa, Bonjour, Ethernet, Internet Explorer, Linux, Microsoft, Mozilla, Real, SMPTE, QuickTime, UNIX, Windows, Windows Vista and WWW are registered trademarks of the respective holders. Java and all Java-based trademarks and logos are trademarks or registered trademarks of Oracle and/or its affiliates. UPnP TM is a certification mark of the UPnP TM Implementers Corporation. Electromagnetic Compatibility (EMC) This equipment has been designed and tested to fulfill applicable standards for:
  • Radio frequency emission when installed according to the instructions and used in its intended environment.
  • Immunity to electrical and electromagnetic phenomena when installed according to the instructions and used in its intended environment. USA - This equipment has been tested using a shielded network cable (STP) and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help. Canada - This Class B digital apparatus complies with Canadian ICES-003. Europe - This digital equipment fulfills the requirements for RF emission according to the Class B limit of EN 55022. This product fulfills the requirements for immunity according to EN 61000-6-1 residential, commercial and light-industrial environments. This product fulfills the requirements for immunity according to EN 55024 residential and commercial environments. Australia - This digital equipment fulfills the requirements for RF emission according to the Class B limit of AS/NZS CISPR 22. Japan - この装置は、クラス B 情報技術装置です。 この装置は、家庭環境で使用することを目 的として いますが、この装置がラジオやテレビジョン受信機 に近接して使用されると、 受信障害を引き起こすこ とがあります。 取扱説明書に従って正しい取り扱い をして下さい。

Korea - ࢇ̛̛ Еɼࢽࡈ %̗ ࢷ࢕ળࢶଢ̛̛ Ի۰࣯ Իɼࢽ߾۰یࡈଜЕʨࡶּ ࢶࡳԻଜֲ ֻ Ҙ एࠇ߾۰یࡈଟܹ ࢑ݡТЬ

  • Safety This product complies with IEC/EN/UL 60950-1, Safety of Information Technology Equipment. The power supply used with this product shall fulfill the requirements for Safety Extra Low Voltage (SELV) and Limited Power Source (LPS) according to IEC/EN/UL 60950-1. AXIS P1214-E/AXIS P1224-E Sensor Unit: This product complies with IEC/EN/UL 60950-1 and IEC/EN/UL 60950-22, Safety of Information Technology Equipment. Equipment Modifications This equipment must be installed and used in strict accordance with the instructions given in the user documentation. This equipment contains no user-serviceable components. Unauthorized equipment changes or modifications will invalidate all applicable regulatory certifications and approvals. Liability Every care has been taken in the preparation of this document. Please inform your local Axis office of any inaccuracies or omissions. Axis Communications AB cannot be held responsible for any technical or typographical errors and reserves the right to make changes to the product and documentation without prior notice. Axis Communications AB makes no warranty of any kind with regard to the material contained within this document, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Axis Communications AB shall not be liable nor responsible for incidental or consequential damages in connection with the furnishing, performance or use of this material. This product is only to be used for its intended purpose. RoHS This product complies with both the European RoHS directive, 2002/95/EC, and the Chinese RoHS regulations, ACPEIP. WEEE Directive The European Union has enacted a Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE Directive). This directive is applicable in the European Union member states. The WEEE marking on this product (see right) or its documentation indicates that the product must not be disposed of together with household waste. To prevent possible harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the product supplier, or the local authority responsible for waste disposal in your area. Business users should contact the product supplier for information on how to dispose of this product correctly. This product should not be mixed with other commercial waste. Support Should you require any technical assistance, please contact your Axis reseller. If your questions cannot be answered immediately, your reseller will forward your queries through the appropriate channels to ensure a rapid response. If you are connected to the Internet, you can:
  • download user documentation and firmware updates
  • find answers to resolved problems in the FAQ database. Search by product, category, or phrases
  • report problems to Axis support by logging in to your private support area
Page 3 of the Axis Communications P1214 user manual — Transportation
Page 3 · cliquer pour agrandir
Page 3

Safeguards

Please read through this Installation Guide carefully before installing the Axis product. Keep the Installation Guide for further reference.

  • Store the Axis product in a dry and ventilated environment.
  • Avoid exposing the Axis product to vibration, shocks or heavy pressure. Do not install the product on unstable brackets, unstable or vibrating surfaces or walls, since this could cause damage to the product.
  • Only use applicable tools when installing the Axis product; excessive force could cause damage to the product.
  • Do not use chemicals, caustic agents, or aerosol cleaners. Use a damp cloth for cleaning.
  • Use only accessories that comply with technical specification of the product. These can be provided by Axis or a third party.
  • Use only spare parts provided by or recommended by Axis.
  • Do not attempt to repair the product by yourself, contact Axis or your Axis reseller for service matters.
  • This Axis product shall be used in compliance with local laws and regulations.

Transportation

  • When transporting the Axis product, use the original packaging or equivalent to prevent damage to the product.
Page 4 of the Axis Communications P1214 user manual — Battery Replacement
Page 4 · cliquer pour agrandir
Page 4

Battery Replacement

This Axis product uses a 3.0 V BR2032 or CR2032 lithium battery as the power supply for its internal real-time clock (RTC). Under normal conditions this battery will last for a minimum of 5 years. Low battery power affects the operation of the RTC, causing it to reset at every power-up. A log message will appear when the battery needs replacing. The battery should not be replaced unless required!

If the battery does need replacing, please contact www.axis.com/techsup for assistance.

  • Dispose of used batteries according to the manufacturer's instructions.
  • Risk of explosion if battery is incorrectly replaced.
  • Replace only with the same or equivalent battery, as recommended by the manufacturer.
Page 5 of the Axis Communications P1214 user manual — Package Contents
Page 5 · cliquer pour agrandir
Page 5

AXIS P12 Network Camera Series

Installation Guide

This Installation Guide provides instructions for installing AXIS P12 Network Camera on your network. For all other aspects of using the product, please see the User Manual, available at www.axis.com

Installation Steps

1. Check the package contents against the list below. 2. Hardware overview. See page 6. 3. Install the hardware. See page 12 4. Access the Axis Product. See page 20.

Package Contents

ItemModels/variants/notes Network cameraMain unit Sensor unit AXIS P1204/AXIS P1214/AXIS P1214-E/AXIS P1224-E/ Connectors2-pin power terminal block 4 pin I/O connector terminal block Mounting AccessoriesAll variants: Mounting rail AXIS P1204: Straight mounting bracket, angled mounting bracket, cover AXIS P1214/AXIS P1224-E: Mounting bracket AXIS P1214-E: Mounting bracket, outdoor housing CDInstallation and Management Software CD, including installation tools and other software Printed materialsAXIS P12 Series Installation Guide (this document) Axis Warranty Document AVHS Authentication key
Page 6 of the Axis Communications P1214 user manual — Hardware Overview
Page 6 · cliquer pour agrandir
Page 6
Axis Communications P1214 — Hardware Overview diagram (page 6)
Fig. 1 · Hardware Overview

1 Power indicator LED 7 Main unit 2 Status indicator LED 8 Network connector see page 9 3 Network indicator LED 9 Control button 4 MicroSD card slot 10 Power connector see page 9 5 Camera connector, see page 9 11 Mounting rail 6 I/O terminal connector see

page 9

Page 7 of the Axis Communications P1214 user manual — Hardware Overview
Page 7 · cliquer pour agrandir
Page 7

AXIS P1204 sensor unit and included accessories

AXIS P1214 sensor unit and included accessories

AXIS P1214-E sensor unit and included accessories

Axis Communications P1214 — Hardware Overview diagram (page 7)
Fig. 2 · Hardware Overview

12 AXIS P1204 sensor unit 16 AXIS P1214 sensor unit 13 Cover 17 Mounting bracket 14 Straight mounting bracket 18 AXIS P1214-E sensor unit 15 Angled mounting bracket 19 Outdoor housing

Page 8 of the Axis Communications P1214 user manual — Hardware Overview
Page 8 · cliquer pour agrandir
Page 8

AXIS P1224-E sensor unit and included accessories

Axis Communications P1214 — Hardware Overview diagram (page 8)
Fig. 3 · Hardware Overview

17 Mounting bracket 20 AXIS P1224-E sensor unit

Page 9 of the Axis Communications P1214 user manual — Connectors
Page 9 · cliquer pour agrandir
Page 9

Connectors

Network - RJ45 Ethernet connector. Supports PoE (Power over Ethernet, class 2).

Due to local regulations or the environmental and electrical conditions in which the product is to be used, a shielded network cable (STP) may be appropriate or required. Any network cables that are routed outdoors or in demanding electrical environments shall be shielded (STP) and intended for their specific use. Make sure the network switch is properly grounded. See Electromagnetic Compatibility (EMC) for regulatory requirements.

Power connector - 2-pin terminal block for power input.

Axis Communications P1214 — Connectors diagram (page 9)
Fig. 4 · Connectors
FunctionPin numberDescription GND1Ground DC Power2Power input 8-28 V DC max 4.7 W

Camera connector - RJ12 connector.

I/O terminal connector - Use in applications for e.g. motion detection, event triggering, time lapse recording and alarm notifications. In addition to an auxiliary power and a GND pin, the I/O terminal connector provides the interface to:

1 2 3 4

  • Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule. The output will show as active (shown under System Options > Port & Devices > Port Status ) if the alarm device is activated.
  • Digital input — An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under System Options > Port & Devices > Port Status ).
Axis Communications P1214 — Connectors diagram (page 9)
Fig. 5 · Connectors
FunctionPin numberNotesSpecifications GND1Ground 3.3 V DC Power2Can be used to power auxiliary equipment. Note: This pin can only be used as power out.Max load = 50 mA Input3Digital input - Connect to GND to activate, or leave floating (or unconnected) to deactivate.0 to +40 V DC Output4Digital output - Internal connection to ground when activated, floating (unconnected) when deactivated. If used with an external relay, a diode must be connected in parallel with the load, for protection against voltage transients.Max load = 100 mA Max voltage = +40 V DC
Page 10 of the Axis Communications P1214 user manual — Connection diagram
Page 10 · cliquer pour agrandir
Page 10

Connection diagram

3.3 V max 50 mA

SD card slot - A standard or high-capacity microSD card (not included) can be used for local recording with removable storage.

unmount the SD card, go to Setup > System Options > Storage > SD Card and click Unmount.

Page 11 of the Axis Communications P1214 user manual — Camera LED Indicators
Page 11 · cliquer pour agrandir
Page 11

Camera LED Indicators

LEDColorIndication NetworkGreenSteady for connection to a 100 MBit/s network. Flashes for network activity. AmberSteady for connection to a 10 MBit/s network. Flashes for network activity. UnlitNo network connection. StatusGreenSteady green for normal operation. AmberSteady during startup and when restoring settings. RedSlow flash for failed upgrade. UnlitNo connection between sensor unit and main unit. PowerGreenNormal operation. AmberFlashes green/amber during firmware upgrade.

configure, go to Setup > System Options > Ports & Devices > LED. See the online help for more information.

Page 12 of the Axis Communications P1214 user manual — Install the hardware
Page 12 · cliquer pour agrandir
Page 12

Install the hardware

!

Make a note of the serial number (S/N) located on the product label. This number may be required during installation.

The main unit for the AXIS P1204/P1214/P1214-E/P1224-E can be mounted on a DIN rail or using the supplied mounting rail.

1. If using the mounting rail, fasten it with screws to the wall or ceiling, using screws and plugs appropriate for the wall/ceiling material. Note the direction of the two tabs on the rail, the tabs align with the upper side of the main unit. 2. Attach the upper end of the main unit to the DIN rail or the mounting rail and snap the lower end into place. 3. Proceed with the instructions for the appropriate camera model below.
Axis Communications P1214 — Install the hardware diagram (page 12)
Fig. 6 · Install the hardware
Page 13 of the Axis Communications P1214 user manual — Flat Surface Installation
Page 13 · cliquer pour agrandir
Page 13

AXIS P1204 Sensor Unit

!

The AXIS P1204 can be mounted in three different ways:

  • flat on any surface
  • angled on any surface, using the angled fastening bracket
  • covertly behind a thin material, for example a metal sheet in a doorpost or an ATM machine.

Flat Surface Installation

1. Fasten the camera to the wall or ceiling, using screws and plugs appropriate for the wall/ceiling material. 2. Snap on the cover. 3. Proceed to Connect the cables, on page 19.
Axis Communications P1214 — Flat Surface Installation diagram (page 13)
Fig. 7 · Flat Surface Installation
Page 14 of the Axis Communications P1214 user manual — Angled Surface Installation
Page 14 · cliquer pour agrandir
Page 14

Angled Surface Installation

1. Fasten the angled mounting bracket to the wall or ceiling, using screws and plugs appropriate for the wall/ceiling material. Ensure that the bracket is pointing towards the area to be monitored. 2. Assemble the plate with the screw and align it so the arrows are vertical or horizontal. 3. Fasten the camera to the plate with the two screws. 4. Snap on the cover. 5. Proceed to Connect the cables, on page 19.
Axis Communications P1214 — Angled Surface Installation diagram (page 14)
Fig. 8 · Angled Surface Installation
Page 15 of the Axis Communications P1214 user manual — Covert Installation
Page 15 · cliquer pour agrandir
Page 15

Covert Installation

1. Drill a hole with 3mm diameter in the wall or ceiling. If the material is thicker than 1mm it may be necessary to expand the hole with a countersink cutter. 2. Pull off the protection on the adhesive and attach the straight mounting bracket to the wall. 3. Insert the camera into the bracket, and fasten with the stop screw. Ensure that the cone of the camera is flush with the wall. 4. Proceed to Connect the cables, on page 19.

Axis Communications P1214 — Covert Installation diagram (page 15)
Fig. 9 · Covert Installation
Page 16 of the Axis Communications P1214 user manual — AXIS P1214/AXIS P1224-E Sensor Unit
Page 16 · cliquer pour agrandir
Page 16

AXIS P1214/AXIS P1224-E Sensor Unit

!

The AXIS P1214/AXIS P1224-E can be mounted behind any wall, with just a small opening for the lens, or with the whole lens assembly protruding through the wall.

1. Drill a hole with 20mm diameter in the wall, either completely through the material, or use a countersink cutter to have a smaller opening. 2. Pull off the protection on the adhesive and attach the mounting bracket to the wall. Optionally secure the bracket with two screws through the holes. 3. Insert the camera and tighten the lock ring as shown in the image below. Position the camera so that the flat surface on the thread is vertical or horizontal. 4. Proceed to Connect the cables, on page 19.

Axis Communications P1214 — AXIS P1214/AXIS P1224-E Sensor Unit diagram (page 16)
Fig. 10 · AXIS P1214/AXIS P1224-E Sensor Unit
Page 17 of the Axis Communications P1214 user manual — AXIS P1214-E Sensor Unit
Page 17 · cliquer pour agrandir
Page 17

AXIS P1214-E Sensor Unit

The AXIS P1214-E can be mounted like the AXIS P1214/AXIS P1224-E, see instructions above.

The AXIS P1214-E can also be mounted in the supplied outdoor housing. The cables can be routed through the wall directly into the housing, or through one of the punch-outs in the cover.

1. Remove the two screws and the bracket. 2. Insert the camera into the ball joint and fasten with the stop screw.
Axis Communications P1214 — AXIS P1214-E Sensor Unit diagram (page 17)
Fig. 11 · AXIS P1214-E Sensor Unit
Page 18 of the Axis Communications P1214 user manual — AXIS P1214-E Sensor Unit
Page 18 · cliquer pour agrandir
Page 18

3. Drill a hole through the wall or remove one of the punch-outs in the cover. 4. Fasten the plate to the wall using screws and plugs appropriate for the wall material. Ensure that the camera bracket is pointing towards the area to be monitored. If routing the cable through the wall, align the cut-out in the plate with the hole in the wall. 5. Place the ball in the socket and fasten the bracket with the screws. Aim the camera away from the wall before tightening the screws. Position the camera so that the flat surface on the thread is vertical or horizontal. 6. Route the cable through the wall, or through the punch-out in the cover. 7. Attach the cover. 8. Proceed to Connect the cables, on page 19.

Axis Communications P1214 — AXIS P1214-E Sensor Unit diagram (page 18)
Fig. 12 · AXIS P1214-E Sensor Unit
Page 19 of the Axis Communications P1214 user manual — Connect the cables
Page 19 · cliquer pour agrandir
Page 19

Connect the cables

  • 1. Optionally connect external input/output devices, e.g. alarm devices. See page 9 for information on the terminal connector pins. 2. Connect the main unit to the network using a shielded network cable. 3. Connect the sensor unit to the main unit. If required, the cable can be shortened. See the User Manual for further information. 4. Connect power, using one of the methods listed below:
  • PoE (Power over Ethernet, Class 2). If available, this is automatically detected when the network cable is connected.
  • Connect power via the terminal connector. See page 9 for information on the terminal connector pins. 5. Check that the indicator LEDs indicate the correct conditions. See the table on page 11 for further details. Note that some LEDs can be disabled and may be unlit.
Page 20 of the Axis Communications P1214 user manual — The Live View Page
Page 20 · cliquer pour agrandir
Page 20

Access the Axis Product

Use the software provided on the Installation and Management Software CD to assign an IP address, set the password and access the video stream.

The Live View Page

The product’s Live View page appears in your browser. Click Setup to open the product’s Setup pages, which allow you to customize the Axis product.

Setup - Provides all the tools for configuring the product to require- ments.

Help - Displays online help on all aspects of using the camera.

Axis Communications P1214 — The Live View Page diagram (page 20)
Fig. 13 · The Live View Page
Page 21 of the Axis Communications P1214 user manual — Warranty
Page 21 · cliquer pour agrandir
Page 21

Resetting to the Factory Default Settings

If the Axis product needs to be reset to factory default, follow these steps:

1. Disconnect power. 2. Press and hold the Control button and reconnect power. 3. Keep the Control button pressed for about 15 seconds until the Status indicator flashes amber. 4. Release the Control button. The process is complete after about 1 minute (when the Status indicator turns green). The product has been reset to the factory default settings.

Further Information

The User Manual is available from the Axis Web site at www.axis.com

Learn more! Visit Axis learning center www.axis.com/academy for useful trainings, webinars, tutorials and guides.

Warranty

For information about Axis’ product warranty and thereto related information, see www.axis.com/warranty

Page 22 of the Axis Communications P1214 user manual — Resetting to the Factory Default Settings
Page 22 · cliquer pour agrandir
Page 22
Page 22 of the Axis Communications P1214 user manual — Resetting to the Factory Default Settings
Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Axis Communications P1214

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Axis Communications P1214

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Axis Communications P1214 manuel PDF

104 pages·6.3 MB·Caméra de surveillance·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…