GS-XP07FR GS-XP09FR GS-XP12FR GS-XP18FR GS-XP24FR GS-XP27FR GS-XP07FR GS-XP09FR GS-XP12FR GS-XP18FR GS-XP24FR GS-XP27FR AE-X7FR AE-X9FR AE-X12FR GU-XR18FR GU-XR24FR GU-XR27FR FLOOR/CEILING TYPE ROOM A.
GS-XP07FR_Eng.p65 05.4.19, 5:05 PM 2 A. Information on Disposal for Users (p ri v ate households) 1. In the European Un ion Attention: If you w ant to dispose of this equip ment, please do not use the.
ENGLISH E-1 ENGLISH Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before operating the product. • IMPORTANT SAFETY INSTRUCTIONS ..... E-1 • ADDITIONAL NOTES ON OPERATION ............. E-3 • TIPS ON SAVING ENERGY .
IMPORT ANT SAFETY INSTRUCTIONS CAUTIONS FOR USE 1 Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage. 2 Do not operate the buttons with wet hand. It may cause electric shock.
ENGLISH INDOOR TEMP. OUTDOOR TEMP. COOLING upper limit 32 ˚ C D.B. 43 ˚ C D.B. 23 ˚ C W.B. - lower limit 21 ˚ C D.B. 21 ˚ C D.B. 15 ˚ C W.B. - HEATING upper limit 27 ˚ C D.B. 24 ˚ C D.B. - 18 ˚ C W.B. lower limit 20 ˚ C D.B. -7 ˚ C D.B. - -8 ˚ C W.
P ART NAMES 1 Outlet (Air) 2 Vertical Adjustment Louvres 3 Horizontal Adjustment Louvres 4 Indicator Panel 5 Air Filters 6 Intake Grille 7 Inlet (Air) 8 Remote Control 9 OPERATION Lamp (red ) 0 TIMER Lamp (orange ) q PLASMACLUSTER Lamp (blue) w RECEIVER Window e AUX.
ENGLISH REMOTE CONTROL 1 TRANSMITTER 2 DISPLAY (Liquid Crystal Display) 3 PLASMACLUSTER Button 4 ON/OFF Button 5 THERMOSTAT Button 6 FULL POWER Button 7 MODE Button 8 ONE-HOUR OFF TIMER Button 9 TIMER.
1 Remove the remote control cover. 2 Insert batteries in the compart- ment, making sure the ± and — polarities are correctly aligned. • The display indicates "AM 6:00" when batteries are prop- erly installed. 3 Reinstall the cover. USING THE REMOTE CONTROL E-6 NOTES: • The battery life is approximately one year in normal use.
ENGLISH E-7 CAUTION • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light.
SWING FAN MODE SET/C 1h Press the THERMOSTAT button to set the desired temperature. • In the AUTO and DRY modes, the tem- perature can be changed in 1°C incre- ments within the range of 2°C higher to 2°C lower from the temperature auto- matically determined by the air conditioner.
ENGLISH E-9 During operation, if the outdoor temperature changes, the temperature settings will automatically slide as shown in the chart. MODE CHANGEOVER During seasons when you need COOLING at dayti.
E-10 ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION HOW TO ADJUST THE AIR FLOW DIRECTION HEAT mode COOL and DRY modes The adjustment range is narrower the SWING range in order to prevent con- densation from dripping. The range is wide so the air flow can be directed toward the floor.
ENGLISH E-1 1 FULL POWER OPERA TION In this operation, the air conditioner works at maximum power to makes the room cool or warm so rapidly that you can use it just after you come home. 1 Press the ONE-HOUR OFF TIMER button. • The remote control displays “ ”.
1 Press the TIMER OFF ( ) button. 2 The TIMER OFF indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the desired time. (The time can be set in 10- minute increments.) 3 Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button.
ENGLISH 1 Press the TIMER ON ( ) button. 2 The TIMER ON indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the de- sired time. (The time can be set in 10-minute increments.) 3 Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button.
E-14 1 TIPS ABOUT PLASMACLUSTER OPERA TION The Plasmacluster ion generator inside the air conditioner will release positive and negative Plasmacluster ions into the room. Approximately the same numbers of positive and negative ions released into the air will reduce some airborne mold.
ENGLISH MAINTENANCE Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance. MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Operate the unit in the COOL mode, temperature setting 32°C, for about half a day to allow the mechanism to thoroughly dry.
CLEANING THE FIL TERS E-16 MAINTENANCE The air filters should be cleaned every two weeks. 1 TURN OFF THE UNIT 2 OPEN THE INTAKE GRILLE 1 Slide the stoppers to the left ( OPEN ). Two stoppers are provided for each the intake grille. 2 Gently pull and open the intake grille.
ENGLISH IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL Check whether the remote con- trol batteries have become old and weak. Try to send the signal again with the remote control pointed prop- erly towards the unit’s signal re- ceiver window.
SHARP CORPORA TION OSAKA, JAPAN TINSEA417JBRZ TH 05D- 1 Printed in Thailand GS-XP07FR_Eng.p65 05.4.1, 4:42 PM 20.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Sharp GS-XP27FR c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Sharp GS-XP27FR - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Sharp GS-XP27FR, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Sharp GS-XP27FR va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Sharp GS-XP27FR, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Sharp GS-XP27FR.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Sharp GS-XP27FR. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Sharp GS-XP27FR ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.