Sharp AY-XP12RMR

144 pages·15.6 MB·Climatiseur·PDF·ENNLJA
Sharp AY-XP12RMR
Table des matières 1 sections ENGLISH AfficherMasquer
Page 1 of the Sharp AY-XP12RMR user manual — CONDIZIONATORE D’ARIA TIPO SPLIT
Page 1 · cliquer pour agrandir
Page 1

SPLIT TYPE ROOM AIR CONDITIONER

ENGLISH ITALIANO EΛΛΗΝΙΚΑ FRANÇAIS DEUTSCH PORTUGUÊS POLSKI

OPERATION MANUAL

Sharp AY-XP12RMR — SPLIT TYPE ROOM AIR CONDITIONER diagram (page 1)
Fig. 1

CONDIZIONATORE D’ARIA TIPO SPLIT

MANUALE DI ISTRUZIONI

ΑΙΡΚΟΝΤΙΣΙΟΝ ΔΩΜΑΤΙΟΥ ΤΥΠΟΥ SPLIT

ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ

AR CONDICIONADO DE SALA DE DUAS UNIDADES

MANUAL DE OPERAÇÃO

ACONDICIONADOR DE AIRE DE DOBLE SERVICIO

ROMÂNĂ БЪЛГАРСКИ ESPAÑOL

MANUAL DE INSTRUCCIONES

CLIMATISEUR INDIVIDUEL EN DEUX PARTIES

MODE D’EMPLOI

APARAT DE AER CONDIŢIONAT DE TIP SPLIT

MANUAL DE UTILIZARE

ТИП - СПЛИТ СИСТЕМА СТАЕН КЛИМАТИК

ИНСТРУКЦИЯ ЗА УПОТРЕБА

ZWEITEILIGES KLIMAGERÄT

BEDIENUNGSANLEITUNG

INDOOR UNIT OUTDOOR UNIT AY-XP9RMR AE-X9RMR AY-XP12RMR AE-X12RMR

POKOJOWY KLIMATYZATOR TYPU SPLIT

INSTRUKCJA OBSŁUGI

"Plasmacluster" and "Device of a cluster of grapes" are registered trademarks or trademarks of Sharp Corporation.

Page 2 of the Sharp AY-XP12RMR user manual
Page 2 · cliquer pour agrandir
Page 2

Information on the Disposal of this Equipment and its Batteries

IF YOU WISH TO DISPOSE OF THIS EQUIPMENT OR ITS BATTERIES, DO NOT USE THE ORDINARY WASTE BIN, AND DO NOT PUT THEM INTO A FIREPLACE!

Used electrical and electronic equipment and batteries should always be collected and treated SEPARATELY in accordance with local law.

Separate collection promotes an environment-friendly treatment, recycling of materials, and minimizing final disposal of waste. IMPROPER DISPOSAL can be harmful to human health and the environment due to certain substances! Take USED EQUIPMENT to a local, usually municipal, collection facility, where available.

Remove USED BATTERIES from equipment, and take them to a battery collection facility; usually a place where new batteries are sold.

If in doubt about disposal, contact your local authorities or dealer and ask for the correct method of disposal.

ONLY FOR USERS IN THE EUROPEAN UNION, AND SOME OTHER COUNTRIES; FOR INSTANCE NORWAY AND SWITZERLAND: Your participation in separate collection is requested by law.

The symbol shown above appears on electrical and electronic equipment and batteries (or the packaging) to remind users of this. If 'Hg' or 'Pb' appears below the symbol, this means that the battery contains traces of mercury (Hg) or lead (Pb), respectively.

Users from PRIVATE HOUSEHOLDS are requested to use existing return facilities for used equipment and batteries. Batteries are collected at points of sale. Return is free of charge.

If the equipment has been used for BUSINESS PURPOSES, please contact your SHARP dealer who will inform you about take-back. You might be charged for the costs arising from take-back. Small equipment (and small quantities) might be taken back by your local collection facility. For Spain: Please contact the established collection system or your local authority for take-back of your used products.

Contains fluorinated greenhouse gases covered by the Kyoto Protocol R410A (Global warming potential 1975)

Page 3 of the Sharp AY-XP12RMR user manual — WARNING
Page 3 · cliquer pour agrandir
Page 3

Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. Visit http://sharp-world.com/ for electronic version of the operation manual. ENGLISH

  • The appliance shall be installed in accordance with national wiring regulations. Improper cable connection can cause the power supply cord, plug and the electrical outlet to overheat and cause fire.
  • If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Use only the manufacture-specified power cord for replacement.
  • Do not splash or pour water directly on the unit. Water can cause electrical shock or equipment damage.
  • Do not attempt to install/remove/repair the unit by yourself. Incorrect work will cause electric shock, water leak, fire etc. Consult your dealer or other qualified service personnel for the installation/removal/ repair of the unit.

CONTENTS

  • SAFETY PRECAUTIONS..................................GB-1
  • PART NAMES....................................................GB-2
  • USING THE REMOTE CONTROL.....................GB-4
  • BASIC OPERATION..........................................GB-5
  • ADJUSTING THE AIR FLOW DIRECTION ..............GB-6
  • TURBO FAN OPERATION................................GB-6
  • PLASMACLUSTER OPERATION......................GB-7
  • SLEEP OPERATION..........................................GB-7
  • SAVE OPERATION............................................GB-8
  • 8°C HEATING OPERATION..............................GB-8
  • SELF DRY OPERATION....................................GB-9
  • DISPLAY BUTTON............................................GB-9
  • TIMER OPERATION..........................................GB-10
  • AUXILIARY MODE.............................................GB-11
  • NOTES ON OPERATION..................................GB-11
  • MAINTENANCE.................................................GB-12
  • TIPS ON SAVING ENERGY..............................GB-12
  • BEFORE CALLING FOR SERVICE..................GB-13

CAUTION

  • Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage.
  • Do not operate the buttons with wet hand. It may cause electric shock.
  • For safety, turn the circuit breaker off when not using the unit for an extended period of time.
  • Check the outdoor unit mounting rack periodically for wear and to make sure it is firmly in place.
  • Do not put anything on the outdoor unit nor step on it. The object or the person may fall down or drop, causing injury.
  • This unit is designed for residential use. Do not use for other applications such as in a kennel or greenhouse to raise animals or grow plants.
  • Do not place a vessel with water on the unit. If water penetrates into the unit, electrical insulations may deteriorate and cause electric shock.
  • Do not block the air inlets nor outlets of the unit. It may cause insufficient performance or troubles.
  • Be sure to stop the operation and turn the circuit breaker off before performing any maintenance or cleaning. A fan is rotating inside the unit and you may get injured.
  • Make sure to connect the air conditioner to power supply of the rated voltage and frequency. Use of a power supply with improper voltage and frequency can result in equipment damage and possible fire.
  • Do not install the unit in a place where inflammable gas may leak. It may cause fire. Install the unit in a place with minimal dust, fumes and

SAFETY PRECAUTIONS

This appliance can be used by children a g e d f r o m 8 y e a r s a n d a b o v e a n d persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

WARNING

  • Do not pull or deform the power supply cord. Pulling and misuse of the power supply cord can result in damage to the unit and cause electrical shock.
  • Be careful not to expose your body directly to the outlet air for a long time. It may affect your physical conditions.
  • When using the air conditioner for infants, children, elderly, bedridden, or disabled people make sure the room temperature is suitable for those in the room.
  • Never insert objects into the unit. Inserting objects can result in injury due to the high speed rotation of internal fans.
  • Ground the air conditioner without fail. Do not connect the grounding wire to gas pipe, water pipe, lightning rod or telephone grounding wire. Incomplete grounding may cause electric shock.
  • If anything is abnormal with the air conditioner (ex. a burning smell), stop the operation immediately and turn the circuit breaker OFF.
  • moisture in the air.
  • Arrange the drain hose to ensure smooth drainage. Insufficient drainage may cause wetting of the room, furniture etc.
  • Make sure a leak breaker or a circuit breaker is installed, depending on the installation location, to avoid electrical shock.
Page 4 of the Sharp AY-XP12RMR user manual — OUTDOOR UNIT
Page 4 · cliquer pour agrandir
Page 4

PART NAMES

INDOOR UNIT

Sharp AY-XP12RMR — INDOOR UNIT diagram (page 4)
Fig. 2

6 Power Supply Cord

7 Vertical Airflow Louver

8 Horizontal Airflow Louver

10 PLASMACLUSTER Lamp (blue )

11 TURBO FAN Lamp (red )

12 TIMER Lamp (orange )

13 OPERATION Lamp (green )

OUTDOOR UNIT

Sharp AY-XP12RMR — OUTDOOR UNIT diagram (page 4)
Fig. 3

15 Refrigerant Pipe and Interconnecting Cord

Actual units might vary slightly from those shown above.

Show 9 more labels / short text on this page
1 Inlet (Air) · 2 Open Panel · 3 Air Filter · 4 AUX Button · 5 Receiver Window · 9 Outlet (Air) · 14 Inlet (Air) · 16 Drainage Hose · 17 Outlet (Air)
Page 5 of the Sharp AY-XP12RMR user manual — DISPLAY
Page 5 · cliquer pour agrandir
Page 5

REMOTE CONTROL

1 TRANSMITTER

Sharp AY-XP12RMR — REMOTE CONTROL diagram (page 5)
Fig. 4

4 TURBO FAN Button

6 SELF DRY Button

7 TIMER ON Button

11 12 13 14 15

16 TIMER OFF Button

17 TURBO FAN Symbol

18 FAN SPEED Symbols

: AUTO : SOFT : LOW : HIGH

19 8°C OPERATION Symbol

DISPLAY

: AUTO : COOL : DRY : FAN : HEAT

Sharp AY-XP12RMR — DISPLAY diagram (page 5)
Fig. 5

24 25 26 27

25 SELF DRY Symbol

29 TIMER ON / TIMER OFF Indicator

Show 21 more labels / short text on this page
2 MODE Button · 3 FAN Button · 5 SAVE Button · 8 CLOCK Button · 9 PLASMACLUSTER Button · 10 ON/OFF Button · 11 SWING Button · 12 Button · 13 SLEEP Button · 14 Button · 15 DISPLAY Button · 20 MODE Symbols · 21 PLASMACLUSTER Symbol · 22 CLOCK Symbol · 23 TRANSMITTING Symbol · 24 ON Symbol · 26 DISPLAY Symbol · 27 SLEEP Symbol · 28 TEMPERATURE Indicator · 30 TIME Indicator · 31 SWING Indicator
Page 6 of the Sharp AY-XP12RMR user manual — CAUTION:
Page 6 · cliquer pour agrandir
Page 6

USING THE REMOTE CONTROL

LOADING BATTERIES 1 Remove the battery cover.

HOW TO USE THE REMOTE CONTROL

Point the remote control towards the receiver window and press the desired button. The unit will make a beep sound when it receives the signal.

  • Press the back side of remote control marked with " ", and slide the cover. 2 Insert two batteries. (AAA(R03))
  • Make sure nothing, such as curtains, blocks the receiver window on the unit.
  • The signal effective distance is 7 m.
  • Make sure the (+) and (-) polarities are correctly aligned. 3 Reinstall the battery cover.

CAUTION:

Sharp AY-XP12RMR — CAUTION: diagram (page 6)
Fig. 6
  • Do not expose the receiver window to direct sunlight. This may adversely affect its operation.
  • Use of certain fluorescent lamp in the same room may interfere with transmission of the signal.
  • Do not leave the remote control in direct sunlight or near a heater. Protect the remote control from moisture and shock.
  • The battery life is approximately 1 year in normal use.
  • When replacing the batteries, always replace both batteries at the same time.
  • If the air conditioner is not going to be used for a long period of time, remove the batteries from the remote control.
Sharp AY-XP12RMR — CAUTION: diagram (page 6)
Fig. 7

SETTING THE CLOCK 1 Press the CLOCK Button.

  • The CLOCK symbol( ) will blink. 2 Press or button to set the current time.
Sharp AY-XP12RMR — CAUTION: diagram (page 6)
Fig. 8
  • Hold down the button to rapidly change the time setting(by 1 minute and then 10 minutes). 3 Press the CLOCK Button.

Receiver window

Page 7 of the Sharp AY-XP12RMR user manual — AUTO MODE
Page 7 · cliquer pour agrandir
Page 7

BASIC OPERATION

1 Press the ON/OFF button to start operation.

  • “ ” will be displayed on the remote control.
  • The green OPERATION lamp ( ) will light up.
Sharp AY-XP12RMR — BASIC OPERATION diagram (page 7)
Fig. 9

TO TURN OFF

Press the ON/OFF button again.

  • “ ” will disappear on the remote control.
  • The green OPERATION lamp ( ) will turn off. 2 Press the MODE button to select the

operation mode.

AUTO COOL DRY FAN HEAT

3 Press or button to set the desired temperature.

(AUTO mode) The temperature indicator will not display and the temperature can not be adjusted. (COOL/DRY/HEAT mode) The temperature setting range: 16-30 °C. (FAN mode) The temperature will not change regardless of the temperature indicator on the remote control. 4 Press the FAN button to set the desired fan

speed.

SOFT LOW HIGH

In the DRY mode, the fan speed is preset to "SOFT ( )" and cannot be changed.

AUTO MODE

In the AUTO mode, the temperature settings and modes are automatically selected according to the room temperature.

Page 8 of the Sharp AY-XP12RMR user manual — HORIZONTAL AIR FLOW DIRECTION
Page 8 · cliquer pour agrandir
Page 8

ADJUSTING THE AIR FLOW DIRECTION TURBO FAN OPERATION

VERTICAL AIR FLOW DIRECTION 1 Press the SWING button to select the

The unit runs at extra high fan speed to reach the desired room temperature faster. 1 In the COOL or HEAT mode, press the

vertical air flow direction.

Sharp AY-XP12RMR — ADJUSTING THE AIR FLOW DIRECTION TURBO FAN OPERATION diagram (page 8)
Fig. 10

TURBO FAN button.

  • “ ” will be displayed on the remote control.
  • The red TURBO FAN lamp ( ) will light up.

Press the TURBO FAN button again.

  • “ ” will disappear on the remote control.
  • The red TURBO FAN lamp ( ) will turn off.
Sharp AY-XP12RMR — ADJUSTING THE AIR FLOW DIRECTION TURBO FAN OPERATION diagram (page 8)
Fig. 11

To stop the desired position, press the SWING button during the louver swinging.

  • In the COOL or DRY mode, the adjustment range is narrower the swing range in order to prevent condensation from dripping.

CAUTION:

  • Never attempt to adjust the vertical airflow louver manually.
  • Manual adjustment of the vertical airflow louver can cause the unit to malfunction.
  • When the vertical adjustment louver is positioned at the lowest position in the COOL or DRY mode for an extended period of time, this may result in condensation.

HORIZONTAL AIR FLOW DIRECTION

  • When the unit is turned off, the use of the TURBO FAN operation will be memorized, and it will be activated the next time you turn on the unit.
  • TURBO FAN operation is not available in AUTO, DRY or FAN mode.

Adjust the horizontal air flow direction using the louver lever.

louver lever

Page 9 of the Sharp AY-XP12RMR user manual — PLASMACLUSTER OPERATION
Page 9 · cliquer pour agrandir
Page 9

PLASMACLUSTER OPERATION

SLEEP OPERATION

Plasmacluster ions released into the room will reduce some airborne mold. 1 During operation, press the PLASMA-

The temperature setting is adjusted to prevent the room from becoming too cold or warm, for example while you sleep. 1 In the COOL, HEAT mode, press the

CLUSTER button.

SLEEP button.

  • “ ” will be displayed on the remote control.
  • The blue PLASMACLUSTER lamp( ) will light up.
  • “ ” will be displayed on the remote control.

Press the SLEEP button again.

Press the PLASMACLUSTER button again.

Sharp AY-XP12RMR — PLASMACLUSTER OPERATION diagram (page 9)
Fig. 12
  • The blue PLASMACLUSTER lamp( ) will turn off.
Sharp AY-XP12RMR — PLASMACLUSTER OPERATION diagram (page 9)
Fig. 13

temperature setting, the set temperature will rise 1°C after each hour(maximum 3°C increase depending on the temperature setting), and af- ter 7 hours the set temperature will decrease 1°C and remain set at that temperature. • During HEAT Mode After setting the SLEEP operation at certain

  • When the unit is turned off, the use of the PLASMACLUSTER operation will be memorized, and it will be activated the next time you turn on the unit.
  • The PLASMACLUSTER ions release simultaneously when the fan of indoor unit operates. The PLASMACLUSTER lamp lights up when the PLASMACLUSTER ions release. The PLASMACLUSTER lamp turns off when the fan of indoor unit does not operate such as defrosting.

temperature setting, the set temperature will de- crease 1°C after each hour(maximum 3°C de- crease depending on the temperature setting), and remain set at that temperature. • SLEEP operation is not available in AUTO, DRY or FAN mode.

Page 10 of the Sharp AY-XP12RMR user manual — SAVE OPERATION
Page 10 · cliquer pour agrandir
Page 10

SAVE OPERATION

8°C HEATING OPERATION

The room will be kept at 8°C to protect the area from frost damage, especially when the house is not occupied. 1 In the HEAT mode, press the SAVE but-

When the room temperature gets closer to the setting temperature, fan speed of indoor unit will decrease. 1 In the COOL mode, press the SAVE

button.

ton.

  • “ ” will be displayed on the remote control.
  • “ ”and “ ” will be displayed on the remote control.

Press the SAVE button again.

Press the SAVE button again.

  • “ ”and “ ” will disappear on the remote control.
Sharp AY-XP12RMR — SAVE OPERATION diagram (page 10)
Fig. 14
Sharp AY-XP12RMR — SAVE OPERATION diagram (page 10)
Fig. 15
  • The fan speed is set to “AUTO” and cannot be changed.
  • The fan speed is set to “AUTO” and cannot be changed.
Page 11 of the Sharp AY-XP12RMR user manual — To turn on the LED indicators
Page 11 · cliquer pour agrandir
Page 11

SELF DRY OPERATION

DISPLAY BUTTON

The indoor fan will continue operation for 2 minutes in order to help remove moisture inside the indoor unit when the unit is turned off. 1 In the COOL or DRY mode, press the

Press the DISPLAY button to turn the LED lights on the indoor unit off. The green OPERATION lamp and the orange TIMER lamp cannot be turned off. 1 During operation, press the DISPLAY

SELF DRY button.

button.

  • “ ” will be displayed on the remote control.
  • After the unit turns off, the indoor fan will operate at low speed for 2 minutes and the orange TIMER lamp will flash every 10 seconds.

To turn on the LED indicators

Press the DISPLAY button again.

  • “ ” will be displayed on the remote control.
Sharp AY-XP12RMR — To turn on the LED indicators diagram (page 11)
Fig. 16 · To turn on the LED indicators

Press the SELF DRY button again.

Sharp AY-XP12RMR — To turn on the LED indicators diagram (page 11)
Fig. 17 · To turn on the LED indicators
  • SELF DRY operation is not available in AUTO, FAN or HEAT mode.
Page 12 of the Sharp AY-XP12RMR user manual — TIMER OPERATION
Page 12 · cliquer pour agrandir
Page 12

TIMER OPERATION

Before setting the timer, make sure the clock is properly set with the current time.

TIMER OFF 1 Press the TIMER OFF button.

TIMER ON 1 Press the TIMER ON button.

  • “ ” will blink on the remote control.
  • “ “ will disappear and previous setting time will display on the remote control . 2 Press the or button to set the desired time.
  • “ ” will blink on the remote control.
  • “ “ will disappear and previous setting time will display on the remote control. 2 Press the or button to set the desired time.
  • Every press of or button changes the time setting by 1 minute. Holding down
  • Every press of or button changes the time setting by 1 minute. Holding down

or button rapidly changes the time setting by 1 minute and then 10 minutes. 3 Press the TIMER OFF button.

or button rapidly changes the time setting by 1 minute and then 10 minutes. 3 Press the TIMER ON button.

  • The orange TIMER lamp ( ) will light up.
  • “ ” will be displayed on the remote control.
  • “ “ and current time will display on the remote control.
  • The orange TIMER lamp ( ) will light up.
  • “ ” will be displayed on the remote control.
  • “ “ and current time will display on the remote control.
Sharp AY-XP12RMR — TIMER OPERATION diagram (page 12)
Fig. 18
Sharp AY-XP12RMR — TIMER OPERATION diagram (page 12)
Fig. 19
  • The orange TIMER lamp ( ) will turn off.
  • “ ” will disappear on the remote control.
  • The orange TIMER lamp ( ) will turn off.
  • “ ” will disappear on the remote control.

The TIMER ON and TIMER OFF can be used in combination.

  • If the remote control buttons are not pressed for 5 seconds while the “OFF” or “ON” is blinking, the “OFF” or “ON” will disappear and any changes made will not be saved.
  • Once you set “TIMER OFF” and/or “TIMER ON”, the timer setting will become daily settings unless you cancel the timer.
  • You cannot program the TIMER ON and TIMER OFF to operate the unit at different temperatures or other settings.
  • Either timer can be programmed to activate prior to the other.
Page 13 of the Sharp AY-XP12RMR user manual — HEATING EFFICIENCY
Page 13 · cliquer pour agrandir
Page 13

AUXILIARY MODE

NOTES ON OPERATION

Use this mode when the remote control is not available

OPERATING CONDITION

Sharp AY-XP12RMR — OPERATING CONDITION diagram (page 13)
Fig. 20

TO TURN ON

COOLING Upper limit 32 ˚C 43 ˚C Lower limit 16 ˚C 5 ˚C

Press the AUX button.

HEATING Upper limit 27 ˚C 24 ˚C Lower limit – –15 ˚C

  • The green OPERATION lamp ( ) will light and the unit will start operating in the AUTO mode.
  • The blue PLASMACLUSTER lamp( ) will lights up when the fan of indoor unit operates.
  • The fan speed and temperature setting are set to AUTO.
  • The built-in protective device may prevent the unit from operating when used at higher temperature than this range.
  • Condensation may form on the air outlet if the unit operates continuously in the COOL or DRY mode when humidity is over 80 %.

TO TURN OFF

WHEN POWER FAILURE OCCURS

Press the AUX button again.

  • This air conditioner has a memory function to store settings when a power failure occurs. After power recovery, the unit will automatically
  • The green OPERATION lamp ( ) and the blue PLASMACLUSTER lamp( ) will turn off.

re-start in the same settings which were set be- fore the power failure, except for timer settings. • If a power failure occurs while the timer is set, the timer setting will be cancelled and will not be retrieved even after the power is restored.

AUX

NOTE ON HEATING OPERATION

DEFROSTING FUNCTION

  • When frost forms on the outdoor unit during heating operation, the unit operate automatic defrosting for about 3 to 12 minutes to remove the frost.
  • During defrosting, the heating operation stops and the red TURBO FAN lamp ( ) on the unit flashes.

HEATING EFFICIENCY

  • The unit employs a heat pump that draws heat from the outside air and releases it into the room. The outside temperature therefore greatly affects the heating efficiency.
  • If the heating efficiency is reduced due to low outside temperatures, use an additional heater.
  • It takes time to warm up and heat the entire room because of the forced air circulation system.
Page 14 of the Sharp AY-XP12RMR user manual — MAINTENANCE BEFORE AIR CONDITIONER SEASON
Page 14 · cliquer pour agrandir
Page 14

MAINTENANCE

TIPS ON SAVING ENERGY

Be sure to stop the operation and turn off the circuit breaker before performing any mainte- nance.

Below are some simple ways to save energy when you use your air conditioner.

Set the proper temperature • Setting too higher or lower than necessary temperature point will result in increased power consumption.

CLEANING THE FILTERS

1. Remove the filters. 1. Lift the open panel. 2. Pull the air filters down to remove them.

Block direct sunlight and prevent drafts

  • Blocking direct sunlight during cooling operation will reduce power consumption.
  • Close the windows and doors during cooling and heating operations.

Keep filter clean to ensure the most efficient operation

Turn off the circuit breaker when the unit is not used for an extended period of time

2. Clean the filters. Use a vacuum cleaner to remove dust. If the filters are dirty, wash them with warm water and a mild detergent. Dry filters in the shade before reinstalling.
  • The indoor unit still consumes a small amount of power when it is not operating.
3. Reinstall the filters and close the open panel.

CLEANING THE UNIT AND THE REMOTE CONTROL

  • Wipe them with a soft cloth.
  • Do not directly splash or pour water on them. It can cause electrical shock or equipment damage.
  • Do not use hot water, thinner, abrasive powders or strong solvents.

MAINTENANCE AFTER AIR CONDITIONER SEASON

1. Operate the unit in the FAN mode for about half a day to allow the mechanism to thoroughly dry.
2. Stop the operation and turn off the circuit breaker.
3. Clean the filters, then reinstall them.

MAINTENANCE BEFORE AIR CONDITIONER SEASON

1. Make sure that the air filters are not dirty.
2. Make sure that nothing obstructs the air inlet or outlet.
Page 15 of the Sharp AY-XP12RMR user manual — BEFORE CALLING FOR SERVICE
Page 15 · cliquer pour agrandir
Page 15

BEFORE CALLING FOR SERVICE

The following conditions do not denote equip- ment malfunctions

Check the following points before calling for service.

Unit does not operate • The unit will not operate if it is turned on im- mediately after it is turned off. The unit will not operate immediately after the mode is changed. This is to protect the unit. Wait 3 minutes before operating the unit.

The unit does not operate • Check if the circuit breaker has tripped or the fuse has blown.

The unit does not cool(or heat) the room ef-

  • fectively
  • Check the filters. If dirty, clean them.
  • Check the outdoor unit to make sure nothing is blocking the air inlet or outlet.
  • Check the temperature setting is proper setting.
  • Make sure windows and doors are closed tightly.
  • Unit does not send out warm air
  • In heating operation, the indoor fan may not start for 2 to 5 minutes after the unit is turned on to prevent cold air from blowing out of the unit.
  • The unit is defrosting. Wait for 3 to 12 minutes. During defrosting, the red TURBO FAN lamp ( ) on the unit flashes.

The unit does not receive the remote control

  • signal
  • Check whether the remote control batteries have become old and weak.
  • Try to send the signal again with the remote control pointed properly towards the unit’s signal receiver window.
  • Check whether the remote control batteries are installed properly.

Odors • Carpet and furniture odors that entered into the unit may be sent out from the unit.

Cracking noise • This sound is generated by the friction of the unit expanding or connecting due to a tempera- ture change.

A low buzzing noise • This is a sound of the unit generating Plasma- cluster ions.

Swishing noise • The soft, swishing noise is the sound of the re- frigerant flowing inside the unit.

Mist seen at indoor air outlet • In cooling operation, this is caused by the differ- ence between the room air temperature and the air discharged.

Water vapour • In heating operation, water vapour may flow out of the outdoor unit during defrosting.

The outdoor unit does not stop • After stopping the operation, the outdoor unit will rotate its fan for about a minute to cool down the unit.

Odor emitted from the plasmacluster air

outlet • This is the smell of ozone generated from the Plasmacluster Ion generator. The ozone con- centration is very small, posing no adverse ef- fect on your health. The ozone discharged into the air rapidly decomposes, and its density in the room will not increase.

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Sharp AY-XP12RMR

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Sharp AY-XP12RMR

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Sharp AY-XP12RMR manuel PDF

144 pages·15.6 MB·Climatiseur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…