Manuel d'utilisation / d'entretien du produit AY-X12LCJ du fabricant Sharp
Aller à la page of 36
OPERATION MANUAL Thank you for choosing a SHARP air conditioner . P lease read this manual reference. thoroughly before using your air conditioner a n d keep it for future Split Type Inverter Room Air.
.
Collection of such waste should be separated for special treatment as required by local regulations. and cleaning ing ing that should be prevented. that NOTE: The figures in this manua l may be different to the actual product.
.
, pl ease r ef er t he m at t er t o a qualified air conditioner contractor . T o c h a n g e t h e a i r f l o w d i r e c t i o n , a d j u s t t h e v e r t i c a l a n d l a t e r a l a i r f l o w d i r e c t i o n b y u s i n g t h e r e m o t e c o n t r o l .
A i r c o n d i t i o n e r s a b s o r b h e a t i n t h e r o o m a n d t r a n s m i t s i t t o t h e o u t d o o r u n i t , s o t h a t i n d o o r a m b i e n t t e m p e r a t u r e s a r e d e c r e a s e d .
Na m e a n d f u n c t i o n o f e a c h p a r t.
N o t e : B e s u r e t h a t t h e r e a r e n o o b s t r u c t i o n s b e t w e e n r e c e i v e r a n d r e m o t e c o n t r o l ; D o n ' t d r o p o r t h r o w t h e r e m o t e c o n t.
N a m e a n d f u n c t i o n o f w i r e l e s s r e m o t e c o n t r o l b u t t o n s o n t h i s c o n t r o l a r e n o t a p p l i c a b l e t o t h i s u n i t . P r e s e t t e m p e r a t u r e i s i n c r e a s e d b y pressing this button.
b u t t o n s o n t h i s c o n t r o l a r e n o t a p p l i c a b l e t o t h i s u n i t . P r e s s t h i s b u t t o n t o s e l e c t T i m e r O n s e t t i n g . P r e s s i n g t h e + o r - b u t t o n d u r i n g t h e f i r s t 5 s e c o n d s a d j u s t s t h e t i m e v a l u e b y o n e m i n u t e e a c h t i m e p r e s s e d .
P r e s s On / Of f b u t t o n t o s t a r t o r s t o p o p e r a t i o n . t o s w i t c h O n o r O f f t h e d i s p l a y o n t h e m a i n u n i t . odels m t o s w i t c h B L O W t he f an w i l l con t i nu e t o bl ow af t er t he un i t i s st op pe d t o r em ove B L O W B L O W t h e f u n c t i o n i s n o t o p e r a t e d .
o s e t t h e g u i d e l o u v r e t o a d e s i r e d p o s i t i o n , p r e s s S w i n g U p a n d D o w n b u t t o n c o n t i n u o u s l y f o r m o r e t h a n 2 s e c o n d s a n d h o l d u n t i l d e s i r e d p o s i t i o n i s a c h i e v e d .
m a i n u n i t . O p e r a t i o n w i l l b e i n A u t o R u n m o d e a n d t h e t e m p e r a t u r e s e t t i n g o r f a n speed cannot be changed. o n t h e T o o p e r a t e : P r e s s t h e A U T O / S T O P b u t t o n a n d t h e u n i t w i l l e n t e r i n t o A U T O R U N m o d e .
Care and Cleaning a t t h e c i r c u i t b r e a k e r t o p r e v e n t t h e r i s k o f e l e c t r i c s h o c k . p o u r o r s p r a y l i q u i d s d i r e c t l y o n t o t h e i n d o o r o r o u t d o o r u n i t s f o r c l e a n i n g , t o p r e v e n t r i s k o f e l e c t r i c s h o c k .
Care and Cleaning Removing R o t a t e t h e f r o n t p a n e l u p w a r d s i n t h e d i r e c t i o n o f t h e a r r o w. P u l l t h e a i r f i l t e r d o w n w a r d s a n d r e m o v e f r o m t h e u n i t . w a t e r t e m p e r a t u r e s h o u l d b e a n d l e a v e t o d r y n a t u r a l l y i n a s h a d y l o c a t i o n .
T h e a i r c o n d i t i o n e r i s n o t u s e r s e r v i c e a b l e . i f a t t e m p t t o I f a b a d s m e l l h a s b e e n a c c u m u l a t e d f r o m t h e e n v i r o n m e n t , c l e a n t h e a i r f i l t e r.
w i l l working Wa t e r i s d r i p p i n g o r l e a k i n g f r o m t h e indoor unit Wa t e r i s d r i p p i n g o r l e a k i n g f r o m t h e outdoor unit H a s t h e c i r c u i t b r e a k e.
air f l o w i s s t o p p e d o n t h e o u t d o o r h e a t e x c h a n g e r. T h e u n i t w i l l a u t o m a t i c a l l y d e f r o s t a n d t h e i n d o o r u n i t w i l l s t o p b l o w i n g a i r f o r 3 - 1 2 m i n s . D u r i n g d e f r o s t o p e r a t i o n , w a t e r o r v a p o u r m a y b e e m i t t e d .
T h e u n i t mus t o n l y b e i n s t a l l e d b y a u t h o r i s e d a i r c o n d i t i o n e r c o n t r a c t o r s a c c o r d i n g t o mun i c i p a l o r g o v e r n men t r e g u l a t i o n s a n d i n c o mpl i a n c e wi t h t h i s man u a l .
A d e d i c a t e d p o w e r s u p p l y c i r c u i t s h o u l d b e u s e d , i n a c c o r d a n c e w i t h l o c a l e l e c t r i c a l safety regulations.
G a p G a p G a p G a p H e i g h t G a p G a p G a p G a p G a p 1 8 0.
i s at t he l ef t , t he r i gh t si de sh ou l d be slightly higher to allow drainage. S p i r i t L e v e l gap gap proper Drainage hoses passing through indoor areas should be wrapped with insulation material. b y r o t a t i n g u p w a r d s . R e m o v e t h e e l e c t r i c a l c o n n e c t i o n c o v e r p l a t e a n d s c r e w.
A l l i n t e r c o n n e c t i n g w i r i n g b e t w e e n i n d o o r a n d o u t d o o r u n i t m u s t b e p e r f o r m e d b y a l i c e n c e d e l e c t r i c a l c o n t r a c t o r i n a c c o r d a n c e w i t h A S / N Z S 3 0 0 0 . u n i t t o t h e s c r e w s a d e q u a t e l y t o p r e v e n t l o o s e n i n g .
R e m o v e e l e c t r i c a l c o n n e c t i o n a c c e s s p l a t e ( e i t h e r r i g h t h a n d s i d e o r f r o n t ) f r o m t h e o u t d o o r u n i t . R e p l a c e a c c e s s p l a t e ( e i t h e r r i g h t h a n d s i d e o r f r o n t ) o n t h e o u t d o o r u n i t .
s o a p y g a s d e t e c t i o n are leaking. Outdoor a t t a c h s a t i s f a c t o r i l y. Installing the Outdoor Unit.
s a t i s f a c t o r y t o t h e p r o d u c t . p r o d u c t . A r e t h e i n l e t a n d o u t l e t a i r o p e n i n g s blocked? I s t h e q u a n t i t y o f g a s c h a r g e s u f f i c i e n t f o r t h e l e n g t h o f p i p e r u n ? m a y b e i n s u f f i c i e n t .
Specifications Model AY-X09LCJ; AE-X09LCJ Function Cooling Heating Rated Voltage (V) 220-240 Frequency (Hz ) 50 Total Capacity (W) (High/Standard): Total Capacity (Btu/h) (High/Standar d): 2600/1188 9000/4063 2805/1109 9800/3792 Power Input (W) (High/ Standard/ Low): 1200/610/264 1250/670/230 Rated Input (W) 610 670 Rated Current (A) 5.
-25- Model of Outdoor Unit AE-X09LCJ Compressor Manufacturer/trademark SANYO Compressor Model C-6RZ110H1A Compressor Type Twin rotary L.R.A. (A) 33 Compressor RLA(A) 4.
-26- Model AY-X12LCJ ; AE-X12LCJ Function COOLING HEATING Rated Voltage (V) 220-240V~ Frequency (Hz) 50 Total Capacity (W) (High/Standard): Total Capacity (Btu/h) (High/ Standard): 3500/ 1233 12000/.
-27- Model of Outdoor Unit AE-X12LCJ Compressor Manufacturer/trademark SANYO Compressor Model C-6RZ110H1A Compressor Type Twin rotary L.R.A. (A) 33 Compressor RLA(A) 4.
-28- Model AY-X18LCJ ; AE-X18LCJ Function COOLING HEATING AC Rated Voltage (V) 220-240V~ Rated Frequency (Hz) 50 Total Capacity (W) (High/Standard): Total Capacity (Btu/h) (High/Standar d): 5300/1610 18000/5500 5600/1217 19100/4150 Power Input (W) 2100/1540/370 2300/1610/398 Rated Input (W) 1540 1610 Rated Current (A) 10.
-29- Model of Outdoor Unit AE-X18LCJ Compressor Manufacturer/trademark SANYO Compressor Model C-6RVN93H0N Compressor Type twin rotary L.R.A. (A) 41 Compressor RLA(A) 7 Compressor Power Input(W) 1610 O.
)RU RXUUHIHUHQFH SOHDVH HQWHU WKHSDUWLFXODUV RI RXU SXUFKDVH EHORZ DQG UHWDLQ ZLWK RXU SXUFKDVH GRFXPHQWDWLRQ 0RGHO1R 6HULDO 1R 'DWHRI 3XUFKDVH 5HWDLOHU )-0/24!.4./4)#%4HISWARRANTYAPPLIES ONLYTOPRODUCTSSOLDIN!USTRALIA .
FOR LOCATION ENQUIRIES WITHIN NEW ZEALAND REGARDING YOUR LOCAL SHARP CORPORATION OF NEW ZEALAND LIMITED VISIT OUR WEBSITE AT SHARP CUSTOMER SERVICES TELEPHONE: 09 573 0111 FACSIMILE: 09 573 0113 FOR LOCATION ENQUIRIES WITHIN AUSTRALIA REGARDING YOUR LOCAL SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www.
.
6612990 SHARP CORPORATION OF AUSTRALIA PTY LTD ABN 40 003 039 405 1 Huntingwood Drive HUNTINGWOOD NSW 2148 www.sharp.net.au.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Sharp AY-X12LCJ c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Sharp AY-X12LCJ - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Sharp AY-X12LCJ, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Sharp AY-X12LCJ va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Sharp AY-X12LCJ, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Sharp AY-X12LCJ.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Sharp AY-X12LCJ. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Sharp AY-X12LCJ ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.