496336 Issue 1 1 of 22 808 Installation and User Guide Compatible Equipment 927 8 character LCD keypad new style case 929 8 character LCD keypad 947 Portable printer ( Battery powered ) and power supp.
2 of 22 496336 Issue 1 Introduction The 808 is a programmable Alarm System suitable for domestic or small commercial premises. The system comprises an end station in a shielded case, and up to four separate keypads.
496336 Issue 1 3 of 22 T echnical Specification General Operating temperature = -10º - +40ºC. Humidity = 80% RH. Dimensions (end station) = h x w x d 300 x 300 x 80mm. Weight (end station) = Approximately. 5Kg. Power Supply System Power Supply (Ambient Temp.
4 of 22 496336 Issue 1 Zone Wiring The recommended maximum distance for FSL zones using standard alarm cable is 200m - 300m. Software Limits The 808 can support: • One to four Levels. • Four Areas in total. • Eight zones provided by the end station PCB plus one zone pro- vided by each keypad.
496336 Issue 1 5 of 22 Enabling/Disabling Keys, Display and Sounder 5. Press ‘Enter’. LED 2 lights and the display shows the status of the keypad sounder: 0 for sounder ‘ON’ or 1 for sounder ‘OFF’, for example: 2- 0 6. Change the keypad sounder status as required by entering 0 or 1.
6 of 22 496336 Issue 1 Wiring The 808 main PCB has facilities for connecting: Four keypads. Eight 2-wire FSL detector zones or eight 4-wire closed circuit zones.
496336 Issue 1 7 of 22 I/P SND SIG SRQ +VE 0V Prog Test 1 2 Vol Display Rear of keypad pcb Tamper N/O Exit Terminate Button or N/C Lock Set Switch End Station Connections 0V SIG +V SRQ Extension Piezo 12VDC E.E. Sounder 25mA Max. + - To other keypad(s) FEZ To detector Figure 3.
8 of 22 496336 Issue 1 2k2 EOL 4k7 Zone 1 CCT Alarm contacts Tamper Loop Zone 1 AT Note: When wiring FSL zones, link out the anti-tamper terminals of each zone in use on the main connnector and expander cards.
496336 Issue 1 9 of 22 4. Press 0. The display shows: 0:INST PROG 5. Press Enter. The display prompts you to remove the end station lid: REMOVE LID 6. If the end station Tamper Switch is already open, close and open it again. You have now reached the Installer programming mode.
10 of 22 496336 Issue 1 Programming Chart 808 Allocate Areas to Levels Allocate keyzones to Levels Allocate Exit Mode Set Exit Time Set Entry Time Select Alarm Type Assign Entry/Exit tones to keypads .
496336 Issue 1 11 of 22 808 Programming Chart Installer Code Audible/Silent/Hidden Tamper, audible, or silent Zone omission 24hr omission Installer reset Anticode reset CSID code RedCare Reset Logging Printer For all types select normally energised or normally de- energised.
12 of 22 496336 Issue 1 Changing Menu Items After selecting a menu, press Enter to see further options belonging to that menu. The system usually displays an abbreviation for the name of the option, and the values the option currently has. A flashing character marks the part of the display that will change when you next press a key.
496336 Issue 1 13 of 22 The display shows the zone number and current attribute. Note that the zone number is flashing (shown here by an underline). Z0 1-NU To select a zone number: 3. Press the up or down arrow keys (A or B) until you see the zone number you want (in this example zone 3).
14 of 22 496336 Issue 1 12. Continue using the right and left arrow keys (C or D) to select attributes and the up or down arrow keys (A or B) to enable or disable them. Note that if you press the left arrow key (D) too often the display will move back to showing the zone number and type only.
496336 Issue 1 15 of 22 Figure 5 shows which letters belong to each number key. Select the letter you want, press the key shown the correct number of times.
16 of 22 496336 Issue 1 2. Press Menu. If the end station lid is open, the displays shows: REPLACE LID 3. Close the end station lid. If no faults are present the display shows the time: 09:00 If faults exist, the display will show, for example: CANT EXT 01 FLTS REVIEW FAULTS 4.
496336 Issue 1 17 of 22 Resetting Customer and Installer Codes (First stage reset) If the installer and/or user codes have been lost, or you need to return the end station to the factory default access codes, you can load the default codes as follows: 1.
18 of 22 496336 Issue 1 8. Press Enter. The display shows: LOADING DEFAULTS Followed by: 00:PROG SYSTEM The end station now has the full set of Scantronic factory defaults and needs reprogramming. NOTES: 1) The Bell output will be energised. If a SAB triggers at this point then check Menu 51.
496336 Issue 1 19 of 22 Menu 50: Program outputs Menu 51: Output Types = Bell = Normally On, Strobe = Normally Off, All other NO Function Menu 52: Internal sounder = Follows Bell Menu 53: Bell Delay =.
20 of 22 496336 Issue 1 you have removed power from the end station while in programming mode with a configuration error.) The end station will not let you leave programming mode until you have cured a configuration error.
496336 Issue 1 21 of 22 The Supervisor can give users 02 to 08 one or more of the following access rights: • Enter a Duress code. • Either Full use (set and unset the Levels they are linked to) or Arm only (set but not unset a Level). • Omit Zones.
22 of 22 496336 Issue 1 To gain access to these menus from a keypad the user must key in: [Access Code] + [Menu key] + [Menu Number] For more information on using the 808 see "808 User Guide". Installer Setting When you leave Programming Mode the system will allow you to enter the Installer access code and use menus 4, 6, 7 and 9.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Security Centres 808 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Security Centres 808 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Security Centres 808, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Security Centres 808 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Security Centres 808, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Security Centres 808.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Security Centres 808. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Security Centres 808 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.