PowerLogic ® ION7550 / ION7650 Energy & Power Quality Meter Installation Guide December 2007.
.
PowerLogic ION7550 / ION7 650 Installation Guide © 2007 Schne ider Electr ic. All rights reserved. 3 Danger This sym bol indica tes the presenc e of dan gerous vo ltage within and outsid e the product enclosure that may constitute a risk of electric shoc k, seriou s injury or death to persons if prope r precaut ions are not follo wed.
PowerLogic ION7550 / ION7650 Installatio n Guide 4 © 2007 Schneider Electric. All rights reserved. This equipm ent generates, uses, and can radiate radio freque nc y e n e r g y a n d , i f n o t i n s t a lled and used in accordance with the instructio n manual, may cause har mful interference to r adio communications.
PowerLogic ION7550 / ION7 650 Installation Guide © 2007 Schne ider Electr ic. All rights reserved. 5 PowerLogic ION7550 / ION7650 Models Integrated Display Model Comes with fr ont optical po rt. TRAN (transdu cer) Model The TRAN model h as no display.
P owerL ogic ION7550 / ION7650 Installation Guide 6 © 2007 Schneider Electric. All rights reserved. Before You Begin Before installing the mete r, familiarize yourself with the steps in this guide and read the safety precautions prese nted on the “Installation Considerations” page.
PowerLogic ION7550 / ION7 650 Installation Guide © 2007 Schne ider Electr ic. All rights reserved. 7 Unit Dimensions Basic Model — Rear View Basic Model — Front View Basic Model — Side View.
P owerL ogic ION7550 / ION7650 Installation Guide 8 © 2007 Schneider Electric. All rights reserved. Step 1: Mount the Meter Environmental Specifications Meter Batter y Considerations The meter’s battery life expectancy de pends on both temperatur e and the amount of time th e meter is without po wer.
PowerLogic ION7550 / ION7 650 Installation Guide © 2007 Schne ider Electr ic. All rights reserved. 9 Step 3: Wire the Digital I/O and Analog I/O Form C Digital Outputs: Me chanical Relays R1 - R3 For.
P owerL ogic ION7550 / ION7650 Installation Guide 10 © 2007 Schneider Electric. All rights rese rved. Digital Inputs: S1 - S8 Digital Inputs (Meter Ordering Option): DI1 - DI8 T ype Self-e xcited (inter nal 30 VDC supply) Application Dry contact sensing, or with external excitation Wire 1.
PowerLogic ION7550 / ION7 650 Installation Guide © 2007 Schne ider Electr ic. All rights reserved. 11 Analog Inputs (Meter Orderi ng Option): AI1 to AI4 N OTE Do not connect the analog input s of the I/O card to t he analog outputs on the same I/O card.
P owerL ogic ION7550 / ION7650 Installation Guide 12 © 2007 Schneider Electric. All rights rese rved. Step 4: Wire the Voltage and Current Inputs V oltage Inputs Current Inputs: Class 20 Current Inputs (5A Option) Current Inputs: Class 2 Current Inputs (1A Option) N OTE The appropriate Volts Mode sett ing is included with each wiring diagram.
PowerLogic ION7550 / ION7 650 Installation Guide © 2007 Schne ider Electr ic. All rights reserved. 13 4-Wire Wye, 3-Element, Direct Connection Diagram 347 V L-N / 600 V L-L max. VOLTS MODE = 4W-Wye 4-Wire Wye, 3-Element, 3 PTs Conn ection Diagram Use PTs for voltages over 347 V L -N / 600 V L-L.
P owerL ogic ION7550 / ION7650 Installation Guide 14 © 2007 Schneider Electric. All rights rese rved. 3-Wire Solid-Grounded Wye, 3- Element, Direct Connection When the common or star point of a 3-wire Wye system is grounded, the meter may be connecte d directly without using PTs, provided that the phase voltages are with in the meter’s range.
PowerLogic ION7550 / ION7 650 Installation Guide © 2007 Schne ider Electr ic. All rights reserved. 15 3-Wire Delta, 2½-Eleme nt, 2 PTs & 3 CTs Use PTs for voltag es over 600 V L-L VOLTS MODE = Delta Single Phase Connection Diagram 277 V L-N / 554 V L-L max.
P owerL ogic ION7550 / ION7650 Installation Guide 16 © 2007 Schneider Electric. All rights rese rved. Step 5: Wire the Communications RS-232 Connections (COM1) RS-485 Connections (COM1 and COM2) Infr.
PowerLogic ION7550 / ION7 650 Installation Guide © 2007 Schne ider Electr ic. All rights reserved. 17 Ethernet Connections (if equipped) 10BASE-T / 100BASE-TX 100BASE-FX (Fiber) Ethernet TCP/IP Ser v.
P owerL ogic ION7550 / ION7650 Installation Guide 18 © 2007 Schneider Electric. All rights rese rved. Step 6: Wire the Power Supply Step 7: Power Up the Meter 1. Ensure t he ground wire is securely conne cted on both e nds. 2. Ensure the meter ’s power supply voltage is within the allowed range.
PowerLogic ION7550 / ION7 650 Installation Guide © 2007 Schne ider Electr ic. All rights reserved. 19 Password A password is required for all front panel conf iguration changes and to enter the Security Setup menu. The passwor d is set to 0 (zero) in the facto ry.
P owerL ogic ION7550 / ION7650 Installation Guide 20 © 2007 Schneider Electric. All rights rese rved. Front Panel Setup Menu Settings The following table lis ts all settings that can be configured via the front panel.
PowerLogic ION7550 / ION7 650 Installation Guide © 2007 Schne ider Electr ic. All rights reserved. 21 COM1 SETUP PRO T OCOL The commu nications protoco l ION , Modbu s RTU , Modbus Master , DNP V3 .
P owerL ogic ION7550 / ION7650 Installation Guide 22 © 2007 Schneider Electric. All rights rese rved. NETWORK SETUP IP ADDRESS Sets the IP address for the meter 000.0 00.000.000 t o 999.999.999.9 99 varies 3 SUBNET MASK Used if subnetting appl ies to your network 000.
PowerLogic ION7550 / ION7 650 Installation Guide © 2007 Schne ider Electr ic. All rights reserved. 23 1 A baud rate of 300 bps is only intended for paging applications. 2 Serial number = PA-03 0 2 B 222 -01, Unit ID = 2222 3 Default IP ADDRESS = 172.
P owerL ogic ION7550 / ION7650 Installation Guide 24 © 2007 Schneider Electric. All rights rese rved. The LEDs on the front panel indicate t he following: Phasor Diagrams You can also view the meter’s phasor diagram in real time. Use t he Phasor Viewer av ailable i n PowerLogic ION Setup v2.
PowerLogic ION7550 / ION7 650 Installation Guide © 2007 Schne ider Electr ic. All rights reserved. 25 WYE - ABC Rotation Applicable Volts Mode = 4W-WYE and 3W -WYE WYE - ACB Rotation Applicable Volts.
P owerL ogic ION7550 / ION7650 Installation Guide 26 © 2007 Schneider Electric. All rights rese rved. 2 Element (3Wire) DELT A - ABC Rotation Applicable Volts Mode = D ELTA 2 Element (3Wire) DELT A -.
PowerLogic ION7550 / ION7 650 Installation Guide © 2007 Schne ider Electr ic. All rights reserved. 27 Step 10: View Meter Data Use the so ftkeys to sel ect which data to dis play. Use the left and right ar row buttons to scroll throug h th e available display screens.
PowerLogic ION7550 / ION7650 with W ebMeter and MeterM@il Instal lation Guide For fur ther assistance please contact us at: Schneider Electric P ower Monitoring and Control 2195 Keati ng Cross Road Sa.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Schneider Electric ION7550 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Schneider Electric ION7550 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Schneider Electric ION7550, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Schneider Electric ION7550 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Schneider Electric ION7550, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Schneider Electric ION7550.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Schneider Electric ION7550. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Schneider Electric ION7550 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.