Access Control Panel user manual SSA-P102 SSA-P102T imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please visit our website.
2_ safety information safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE.
English _ 3 SAFETY INFORMATION Keep out of direct sunlight and heat radiation sources. It may cause fi re. Install it in a place with good ventilation.
4_ contents contents PRODUCT INTRODUCTION 5 5 FeatureS 6 What’s included 9 Cable Selection INSTALLATION AND EXTERNAL CONNECTION 10 10 Connecting the termination resistor and diode 11 Earth-grounding.
English _ 5 PRODUCT INTRODUCTION FEATURES This is a state-of-the-art single door access controller device that provides a high level security system in an affordable price, meeting the needs in the security industry.
6_ product introduction product introduction Time Scheduling You can specify a time range during which a specifi c operation is performed. You can specify a specifi c time range for a schedule code, which will be transferred to the applicable device.
English _ 7 PRODUCT INTRODUCTION Main Board 1 Fixing Hole Used to attach SSA-P102 to the closure using a metal supporter. (Ensure that you use the metal supporter to prevent the EMI.) 2 2Pin DIP Switch Used to set the type of a connected reader to either 26bit Wiegand or 34bit Wiegand.
8_ product introduction product introduction 10 Input #3 Input Port: The fl ashing LED indicator denotes that a signal is sensed by the port. 11 Input #2 Input Port: The fl ashing LED indicator denotes that a signal is sensed by the port. (connected to the Door Contact Sensor.
English _ 9 PRODUCT INTRODUCTION CABLE SELECTION Item Cable Type 1 DC 12V Product Power This product Belden #9409, 18 AWG 2 Conductor, Unshielded 2 Reader (Power and Data) External Reader This.
10_ installation and external connection installation and external connection CONNECTING THE TERMINATION RESISTOR AND DIODE Termination Resistor A resistor is inserted for matching the line’s impedance to prevent distortion and reduction in RS-422 or RS-485 long distance data communications, which is referred to as termination resistor.
English _ 11 INSTALLATION AND EXTERNAL CONNECTION EARTH-GROUNDING THE COMMUNICATION CABLES We recommend you to use a proper grounding system for the communication cables. The best grounding method is to earth-ground the shield wire of the communication cable.
12_ installation and external connection installation and external connection POWER, READER, AND I/O CONNECTION Power Connection Check the location of the power port. - Connect the plus (+) line of DC 12V to the corresponding port (+12V). - Connect the plus (-) line of DC 12V to the GND (-) port.
English _ 13 INSTALLATION AND EXTERNAL CONNECTION Input Connection - The Input #1 and Input #2 ports have the Exit button and the Door Contact Sensor installed, while Input #3 to Input #5 can be confi gured to your preference. - Exit Button Connection Connect one line of the Exit button to IN 1.
14_ installation and external connection installation and external connection Output Connection - According to the operation mode, the Door Lock type is classifi ed in two: NC (Normal close) and NO (Normal Open).
English _ 15 INSTALLATION AND EXTERNAL CONNECTION COMMUNICATION LINE CONNECTION RS-232 Communication Port Connection A 9-pin connector for serial communication is required to make connection to the PC. Connect the 9 pin connector for RS-232 communications as follows: Connect RS-232-TX to pin #2 of the 9-pin connector.
16_ installation and external connection installation and external connection RS-422 Communication Port Connection (Standalone) The RS-422/RS-232 converter is required to establish RS-422 communications. Connect the 9-pin connector of the RS-422/RS-232 converter as follows: Connect RS-422-TX(-) to the RX(-) port of the converter.
English _ 17 INSTALLATION AND EXTERNAL CONNECTION RS-422 Communication Port Connection (Multiple Units) The RS-422/RS-232 converter is required to establish RS-422 communications with SSA-P102. - Follow the guidelines below to make connection between devices.
18_ installation and external connection installation and external connection TCP/IP Communication Port Connection 1) TCP/IP Communication Connection SSA-P102T is required to establish TCP/IP communications. 2) Cabling Connect the LAN cable to the TCP/IP RJ-45 jack as shown.
English _ 19 INITIALIZATION Initialization SYSTEM INITIALIZATION Initializing the system using the Initialize switch Apply the power and initialize the system by using the initialization switch. Locate the Initialize switch ( ) on the upper right corner and press both switches simultaneously.
20_ initialization initialization BOARD ID SETTING Each device in the multi-serial communication connection is assigned with a unique number to identify each other. The initial value of the switch is “0”, and all of the 8 switches are defaulted to OFF.
English _ 21 TROUBLESHOOTING troubleshooting TROUBLESHOOTING If the product does not function properly, please see the below for trouble shooting. If the trouble persists, please contact the SAMSUNG Customer Service near you. Problem Action Can I specify RF only or RF+P/W mode differently according to the card? 1) It is not available.
22_ troubleshooting troubleshooting The reader reads a card normally but no reaction is made to SSA-P102 or an irrelevant card number is displayed. 1) Check the power source of the reader. (Check if the LED indicator of the reader is blinking when it has read a card.
English _ 23 product specifi cations PRODUCT SPECIFICATIONS Item SSA-P102 SSA-P102T Users 10,000 ~ 50,000 Users (Default: 10,000) Event Buffer 50,000 ~ 100,000(Default: 50,000) Power / Current DC 12V / Max.120mA Reader Port 2ea : 26bit/ 34bit Wiegand(Selectable), 4 / 8bit Burst for PIN Door Open Time 00~99 Sec.
AB82-02555A Correct disposal of batteries in this product (Applicable in the European Union and other European countries with separate battery return systems.) This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Samsung SSA-P102 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Samsung SSA-P102 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Samsung SSA-P102, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Samsung SSA-P102 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Samsung SSA-P102, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Samsung SSA-P102.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Samsung SSA-P102. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Samsung SSA-P102 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.