Table des matières 39 sections RESV1300 ELECTRIC MULCHINATOR BLOWER / VACUUM · OPERATOR’S MANUAL · FOR QUESTIONS, CALL 1-800-345-8746 in U.S. or · 1-800-668-1238 in CANADA www.RyobiOutdoor .com · … AfficherMasquer
Page 1 of the Ryobi RESV1300 user manual — FOR QUESTIONS, CALL 1-800-345-8746 in U.S. or
Page 1 · cliquer pour agrandir
Page 1

RESV1300 ELECTRIC MULCHINATOR BLOWER / VACUUM

OPERATOR’S MANUAL

FOR QUESTIONS, CALL 1-800-345-8746 in U.S. or

1-800-668-1238 in CANADA www.RyobiOutdoor .com

SAVE THESE INSTRUCTIONS DO NOT THROW AWAY

Page 2 of the Ryobi RESV1300 user manual — INTRODUCTION TABLE OF CONTENTS
Page 2 · cliquer pour agrandir
Page 2

INTRODUCTION TABLE OF CONTENTS

THANK YOU Thank you for buying this quality product. This modern outdoor power tool will provide many hours of useful service. You will find it to be a great labor-saving device. This operator’s manual provides you with easy-to- understand operating instructions. Read the whole manual and follow all the instructions to keep your new outdoor power tool in top operating condition. PRODUCT REFERENCES, ILLUSTRATIONS AND SPECIFICATIONS All information, illustrations and specifications in this manual are based on the latest product information available at the time of printing. We reserve the right to make changes at any time without notice. Copyright© 2003 MTD SOUTHWEST INC All Rights Reserved.

I. Rules for Safe Operation 3-6 A. Important Safety Information 3 B. Safety and International Symbols 5 C. Know Your Unit 6

II. Assembly Instructions 7-8 A. Attaching and Removing the Blower/Vacuum Tube . . 7 B. Attaching and Removing the Vacuum Bag 8 C. Installing the Shoulder Harness 8

III. Operating Instructions 9-13

A. Connecting the Power Cord 9 B. Starting/Stopping Instructions 9 C. Holding the Blower/Vacuum 10 D. Air Vents 10 E. Operating as a Blower 11 F. Operating as a Vacuum 12 G. Clearing a Blocked Impeller 13 H. Empty the Vacuum Bag 13

IV. Maintenance and Repair Instructions 14

SERVICE INFORMATION Service on this unit both within and after the warranty period should be performed only by an authorized and approved service dealer. Dial:

A. Servicing Double-Insulated Units 14 B. Cleaning the unit 14 C. Cleaning the Vacuum Bag 14 D. Storage 14 E. Inspecting Extension Cords 14 F. Accessories/Replacement Parts 14

  • Call 1-800-345-8746 in the United States or 1-800-668-1238 in Canada, to obtain a listing of authorized service dealers near you.

V. Specifications 15

VI. Troubleshooting 15

VII. Warranty 18

  • Go to <a href="http://www.RyobiOutdoor.com" rel="nofollow noopener" target="_blank">www.RyobiOutdoor.com</a> on the World Wide Web for a listing of service dealers near you

VII. Parts List Inside Back Cover

DO NOT RETURN THE UNIT TO THE RETAILER. NOTE: PROOF OF PURCHASE WILL BE REQUIRED

FOR WARRANTY SERVICE.

CONTENTS OF CARTON This unit includes the following:

  • Blower/Vacuum Model RESV1300

Make sure you carefully read and understand this manual before starting or operating this equipment. THIS PRODUCT IS COVERED BY ONE OR MORE US PATENTS, OTHER PATENTS PENDING.

  • Blower/Vacuum Tube
  • Shoulder Strap
  • Vacuum bag
  • Hardware Pack
  • Operator’s Manual
  • Owner’s Registration Card

Examine all parts to make certain that nothing is missing and no breakage has occurred during shipping. Damaged or missing parts must be replaced before using this unit.

or

Page 3 of the Ryobi RESV1300 user manual — DANGER:
Page 3 · cliquer pour agrandir
Page 3

RULES FOR SAFE OPERATION

SYMBOL MEANING The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, deserve your careful attention and understanding. The safety warnings do not by themselves eliminate any danger. The instructions or warnings they give are not substitutes for proper accident prevention measures.

Failure to obey a safety warning will result in serious injury to yourself or to others. Always follow the safety precautions to reduce the risk of fire, electric shock and personal injury.

DANGER:

SYMBOL MEANING

Failure to obey a safety warning can result in injury to yourself and others. Always follow the safety precautions to reduce the risk of fire, electric shock and personal injury.

Indicates danger, warning or caution. Attention is required in order to avoid serious personal injury. May be used in conjunction with other symbols or pictographs.

SAFETY ALERT:

Failure to obey a safety warning may result in property damage or personal injury to yourself or to others. Always follow the safety precautions to reduce the risk of fire, electric shock and personal injury.

CAUTION:

to the operation or maintenance of the equipment.

  • IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE OPERATING

  • Use the unit only in daylight or good artificial light.
  • Keep all bystanders, especially children and pets, at least 50 feet (15 m) away from the unit while operating. ELECTRICAL SAFETY WARNINGS
  • Since the tool is double-insulated, a 2-wire extension cord (an extension cord without a ground) may be used. A 3-wire extension cord (an extension cord with a ground) that uses a NEMA type connector (parallel blade, U ground) is recommended. Extension cords are available from your local retailer. Use only roundjacketed extension cords approved for outdoor use.

When using the unit, you must follow the safety rules. Please read these instructions before operating the unit in order to ensure the safety of the operator and any bystanders. Please keep these instructions for later use.

  • Read the instructions carefully. Be familiar with the controls and proper use of the unit.
  • Do not operate this unit when tired, ill or under the influence of alcohol, drugs or medication.
  • Children and teens under the age of 15 must not use the unit, except for teens guided by an adult.
  • Before each use, thoroughly inspect your unit for loose or damaged parts. Do not use until adjustments or repairs are made.
  • All guards and safety attachments must be installed properly before operating the unit.
  • This tool is double-insulated. Repair or replace damaged cords.

To reduce the risk of electrical shock, use only SW-A, SOW-A, STW-A, STOW-A, SJW-A, SJOW-A, SJTW-W or SJTOW-A cord types. WARNING:

  • To reduce the risk of electrical shock, this unit has a polarized plug (one blade is wider than the other). This unit will fit with a polarized plug in one way only. If the plug does not fit fully into the unit, reverse the plug. If it still does not fit, use a cord with the correct connection. Do not modify the unit in any way.
  • Inspect the area before starting the Blower/ Vacuum. Remove all debris and hard or sharp objects such as glass, wire, etc.
MINIMUM WIRE SIZE FOR EXTENSION CORDS FOR 120 VOLT APPLIANCES USING 0-12 AMPS* Cord length (ft.)2550100150 Wire size (AWG)*16161614

When using electric gardening appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock and personal injury. Carefully read and understand the entire operator's manual before using your unit. Pay close attention to the operating instructions and safety warnings.

DANGER:

*The wire size (AWG) for appliances using 12 to 16 amps is 14 AWG for 25 feet, 12 AWG for 50 feet, and not recommended for 100 or 150 feet.

Page 4 of the Ryobi RESV1300 user manual — SAVE THESE INSTRUCTIONS
Page 4 · cliquer pour agrandir
Page 4

RULES FOR SAFE OPERATION

  • CORD SETS: Make sure your cord set is in good condition, with a cord that is heavy enough to carry the current that your unit will draw. An undersized cord set will cause a drop in line voltage resulting in a loss of power, as well as overheating. The table shown above illustrates the correct size to use depending on the cord length and nameplate amperage rating. If in doubt, use the next heavier size line gauge. The smaller the gauge number, the heavier the cord. To prevent the cord from disconnecting from the unit, use the cord hook shown in the Operating Instructions .
  • Ground Fault Circuit Interrupter (GFCI) protection should be provided on the circuit(s) or outlet(s) that will be used for the unit. Use receptacles with built-in GFCI protection for an extra measure of safety.
  • A nameplate on your unit indicates the voltage used. Never connect the unit to an AC voltage that differs from this voltage.
  • Do not leave the Blower/Vacuum plugged in when not in use, changing tubes, or while being serviced.
  • Do not put any object into openings. Do not use with any opening blocked; keep free of dirt, debris and anything that may reduce the air flow.
  • Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
  • Use only Genuine Factory Parts™ replacement parts when servicing this unit. These parts are available from your authorized service dealer. Do not use unauthorized parts, accessories, or attachments for this unit. Doing so could lead to serious injury to the user, or damage to the unit, and void your warranty.
  • Do not force unit. It will do the job better and with less likelihood of injury at a rate for which it was designed.
  • Inspect all extension cords and the unit power connection periodically. Look closely for deterioration, cuts or cracks in the insulation. Also inspect the connections for damage. Repair or replace the cords if any defects appear.
  • Never use the Blower/Vacuum without the blower/vacuum tube and vacuum bag attached.
  • Avoid dangerous environments. Never operate your unit in damp or wet conditions. Moisture is a shock hazard.
  • Do not use the unit in the rain.
  • Do not handle the plug or the unit with wet hands.
  • Turn off all controls before unplugging.
  • Unplug the Blower/Vacuum before attempting to install or remove the blower/vacuum tube or vacuum bag. The unit must be unplugged, and the impeller blades stopped to avoid contact with the rotating blades.
  • WHILE OPERATING
  • Wear safety glasses or goggles that are marked as meeting ANSI Z87.1-1989 standards. Also wear ear/hearing protection when operating this unit. Wear a face or dust mask if the operation is dusty. Long sleeve shirts are recommended.
  • Wear heavy, long pants, boots and gloves. Do not wear loose clothing, jewelry, short pants, sandals or go barefoot. Secure hair above shoulder level.
  • Avoid accidental starting. Do not carry around a unit that is plugged in with your finger on the trigger switch. Be sure the switch is in the off position when plugging in the unit.

WHILE OPERATING UNIT AS A BLOWER • Never point the blower in the direction of people or pets, or in the direction of windows. Always direct the blowing debris away from people, animals, and windows. Use extra caution when blowing debris near solid objects such as trees, automobiles, walls, etc.

WHILE OPERATING UNIT AS A VACUUM • Avoid situations that could catch the vacuum bag on fire. Do not operate near an open flame. Do not vacuum warm ash from fireplaces, barbecue pits, brush piles, etc. Do not vacuum discarded cigars or cigarettes unless the cinders are completely cool.

  • Do not set unit on any surface except a clean, hard area while engine is running. Debris such as gravel, sand, dust, grass, etc. could be picked up by the air intake and thrown out by the discharge opening, damaging unit, property, or causing serious injury to bystanders or operator.
  • Use the right tool. Only use this tool for the purpose intended.
  • Do not overreach. Always keep proper footing and balance. Do not operate from unstable surfaces like ladders, trees, slopes or rooftops.
  • Do not abuse the power cord. Do not pull or carry the unit by the cord, use the cord as a handle, close a door on the cord, or pull the cord around sharp edges or corners. Keep the cord away from heated surfaces, oil and sharp edges.
  • The unit is designed to pickup dry material such as leaves, grass, small twigs, and bits of paper. Do not attempt to vacuum wet debris and/or standing water as this may result in damage to the blower/ vacuum. To avoid severe damage to the impeller, do not vacuum metal, broken glass, etc.
  • OTHER SAFETY WARNINGS
  • Be sure to secure the unit while transporting.
  • Store the unit in a dry area, locked up to prevent unauthorized use or damage, and stored in a high place out of the reach of children.
  • Never douse or squirt the unit with water or any other liquid. Keep handles dry, clean and free from debris. Clean after each use. See the Cleaning and Storage instructions.
  • Keep these instructions. Refer to them often and use them to instruct other users. If you loan someone this unit, also loan them these instructions.
  • Do not unplug by pulling on the cord. To unplug, grasp the plug, not the cord.
  • Always remain alert. Use common sense. To prevent injury to yourself and others, do not operate this unit if you are fatigued.
  • Do not operate the unit while under the influence of drugs, alcohol or medication.

SAVE THESE INSTRUCTIONS

Page 5 of the Ryobi RESV1300 user manual — SYMBOL MEANING
Page 5 · cliquer pour agrandir
Page 5

RULES FOR SAFE OPERATION

SAFETY AND INTERNATIONAL SYMBOLS This operator's manual describes safety and international symbols and pictographs that may appear on this product. Read the operator's manual for complete safety, assembly, operating and maintenance and repair information.

SYMBOL MEANING

SYMBOL MEANING

  • SAFETY ALERT SYMBOL
  • DO NOT USE IN THE RAIN WARNING: Avoid dangerous environments. Never operate your unit in the rain, or in damp or wet conditions. Moisture is a shock hazard.

Indicates danger, warning, or caution. May be used in conjunction with other symbols or pictographs.

  • WARNING - READ OPERATOR'S MANUAL
  • BLOWERS – ROTATING IMPELLER BLADES CAN CAUSE SEVERE INJURY WARNING: Stop the engine and allow the impeller to stop before opening the vacuum door, installing or changing tubes or bag, or before cleaning or performing any maintenance .

Read the Operator’s Manual(s) and follow all warnings and safety instructions. Failure to do so can result in serious injury to the operator and/or bystanders.

  • WEAR EYE AND HEARING PROTECTION WARNING: Thrown objects and loud noise can cause severe eye injury and hearing loss. Wear eye protection meeting ANSI Z87.1-1989 standards and ear protection when operating this unit. Use a full face shield when needed.
  • BLOWER/VACUUM MODE CHANGE-OVER LEVER

A - Vacuum mode B - Blower mode

  • THROWN OBJECTS AND ROTATING CUTTER CAN CAUSE SEVERE INJURY WARNING: Keep clear of blower outlet. Never point the blower at yourself or others. Objects can be thrown from blower. Do not operate unit without proper attachments and guards in place.
  • KEEP BYSTANDERS AWAY WARNING: Keep all bystanders, especially children and pets, at least 50 feet (15 m.) from the operating area.
Page 6 of the Ryobi RESV1300 user manual — KNOW YOUR UNIT
Page 6 · cliquer pour agrandir
Page 6

RULES FOR SAFE OPERATION

KNOW YOUR UNIT

APPLICATION As a blower: • Cleaning of yards, garages, driveways, porches, patios, around walls, fences, etc.

As a vacuum: • Picking up leaves, light debris, etc.

Vacuum Bag Blower/Vacuum Mode

Show 10 more labels / short text on this page
Latch Support · Blower/Vacuum Tube · Vacuum Inlet · Power/Speed Switch · Motor Air Vents · Blower Outlet · Vacuum Bag Hook · Cord Receptacle · Change-Over Lever · Vacuum Bag Zipper
Page 7 of the Ryobi RESV1300 user manual — ATTACHING AND REMOVING THE BLOWER/VACUUM TUBE
Page 7 · cliquer pour agrandir
Page 7

ASSEMBLY INSTRUCTIONS

ATTACHING AND REMOVING THE BLOWER/VACUUM TUBE

Removing NOTEIt may be necessary to remove the

Blower/Vacuum Tube to clear a blocked tube or impeller.

To avoid serious personal injury, the blower/vacuum tube and vacuum bag must be used when operating this unit. WARNING:

Ryobi RESV1300 — ATTACHING AND REMOVING THE BLOWER/VACUUM TUBE diagram (page 7)
Fig. 1

To prevent serious injury, make sure the unit is in the off position, it is unplugged, and the impellers have stopped before attaching or removing tubes.

Attaching NOTEThe Blower/Vacuum Tube comes un assembled

on this unit. Installation is required to provide safe and easy use for the operator.

1. Remove the 2 (two) self-tapping screws from either side of the housing.

To prevent serious injury, make sure the unit is in the off position, it is unplugged, and the impellers have stopped before attaching or removing tubes.

2. Remove the 2 (two) screws and nuts holding the blower/vacuum tube on the housing (Fig. 2).
1. Remove the screws and nuts provided from the hardware pack.
2. Insert the blower/vacuum tube all the way into the opening on the motor housing until the holes in the tabs on the blower/vacuum tube align with the screw holes in the housing (Fig. 1).
3. Insert the 2 (two) 8-32 x 3/4” slotted T20 Torx screws into the right side of the motor housing and the 2 (two) nuts into the left side of the motor housing (Fig. 1).

Fig. 2 3. Remove the blower/vacuum tube from the motor housing.

4. Replace Blower/Vacuum Tube before use.
4. Tighten the screws firmly. Do not over-tighten.
5. Install the 2 (two) remaining self-tapping 8-16 x 3/4” slotted T20 Torx screws into the holes on either side of the housing (Fig. 1). Tighten until snug, do not over-tighten.
Show 10 more labels / short text on this page
Motor Housing · Nut · Screw and Nut · Self Tapping · Screw · Blower/Vacuum · Tube · Screw and Nut · Screw · Self-Tapping Screw
Page 8 of the Ryobi RESV1300 user manual — ATTACHING AND REMOVING THE VACUUM BAG
Page 8 · cliquer pour agrandir
Page 8

ASSEMBLY INSTRUCTIONS

ATTACHING AND REMOVING THE VACUUM BAG

INSTALLING THE SHOULDER HARNESS 1. Push the strap through the center of the buckle.

Attaching 1. Attach the vacuum bag to the vacuum bag hook on the blower/vacuum tube (Fig. 3).

2. Pull the strap over the cross bar and down through the slot in the buckle (Fig. 6).
Ryobi RESV1300 — ATTACHING AND REMOVING THE VACUUM BAG diagram (page 8)
Fig. 2
Ryobi RESV1300 — ATTACHING AND REMOVING THE VACUUM BAG diagram (page 8)
Fig. 3
2. Slide the vacuum bag tube over the debris exhaust tube on the housing. Push the tube until the latching tabs on both sides click into place, securing the bag on the unit (Fig. 4).
3. Snap the clip on to the support fitting (Fig. 7).
Ryobi RESV1300 — ATTACHING AND REMOVING THE VACUUM BAG diagram (page 8)
Fig. 4

Removing 1. Press the latching tabs on both sides of the vacuum bag tube and pull the vacuum bag down from the unit (Fig. 5).

4. While standing in the operating position adjust length to fit the operator’s size. Pull tab to lengthen, pull strap to shorten (Fig 8).
Ryobi RESV1300 — ATTACHING AND REMOVING THE VACUUM BAG diagram (page 8)
Fig. 5
2. Detach the vacuum bag from the vacuum bag hook.

Support Fitting

Page 9 of the Ryobi RESV1300 user manual — ATTACHING AND REMOVING THE VACUUM BAG
Page 9 · cliquer pour agrandir
Page 9

CONNECTING THE POWER CORD Use a minimum 25 foot (7.6 m.) long, 16AWG, outdoor electrical cord when using this unit. Other sizes include:

2. Plug the female end of the electrical cord into the receptacle at the back of the unit (Fig. 10).
Ryobi RESV1300 — ATTACHING AND REMOVING THE VACUUM BAG diagram (page 9)
Fig. 6
Ryobi RESV1300 — ATTACHING AND REMOVING THE VACUUM BAG diagram (page 9)
Fig. 7
MINIMUM WIRE SIZE FOR EXTENSION CORDS FOR 120 VOLT APPLIANCES USING 0-12 AMPS Cord length (ft.)2550100150 Wire size (AWG)16161614

To reduce the risk of electrical shock, this unit has a polarized plug (one blade is wider than the other) and will require the use of a polarized extension cord.

This unit plug will only fit into a polarized extension cord in one orientation. If the plug does not fully fit into the extension cord, reverse the plug. If the plug still does not fit, obtain a correct polarized extension cord. A polarized extension cord will require the use of a polarized wall outlet. This plug will only fit into a polarized wall outlet in a specific orientation. If the plug does not fit fully into the wall outlet, reverse the plug. If the plug still does not fit, contact a qualified electrician to install the proper wall outlet. Do not change the unit plug, extension cord receptacle, or extension cord plug in any way. 1. Secure the extension cord to the motor housing as shown (Fig. 9). This prevents accidental removal of the electrical cord.

STARTING/STOPPING INSTRUCTIONS This unit is equipped with a three-way (OFF/ LOW/ HIGH) switch (Fig. 11): • Slide the switch all the way down for OFF.

  • Slide the switch up to the first click for LOW .
  • Slide the switch up to the second click for HIGH . Once the unit is plugged in, stand in the operating position (Fig. 12). Slide the power/speed switch to LOW or HIGH to start the unit. To stop the unit, slide the switch to OFF (Fig. 11).
Ryobi RESV1300 — ATTACHING AND REMOVING THE VACUUM BAG diagram (page 9)
Fig. 8
Ryobi RESV1300 — ATTACHING AND REMOVING THE VACUUM BAG diagram (page 9)
Fig. 9

Fig. 9 Fig. 11

Page 10 of the Ryobi RESV1300 user manual — ATTACHING AND REMOVING THE VACUUM BAG
Page 10 · cliquer pour agrandir
Page 10

HOLDING THE BLOWER/VACUUM Before operating the unit, stand in the operating position. (Fig. 12). Check for the following: • Operator is wearing proper clothing, such as boots, safety glasses or goggles, ear/hearing protection, gloves, long pants and long sleeve shirt

  • Operate power equipment only at reasonable hours— not early in the morning or late at night when people might be disturbed. Comply with times listed in local ordinances. Usual recommendations are 9:00 am to 5:00 pm, Monday through Saturday.
  • To reduce noise levels, limit the number of pieces of equipment used at any one time.

To avoid serious personal injury, wear goggles or safety glasses at all times when operating this unit. Wear a face mask or dust mask in dusty locations.

  • To reduce noise levels, operate power blowers at the lowest possible speed to do the job.
  • Use rakes and brooms to loosen debris before blowing.
  • In dusty conditions, slightly dampen surfaces or use a mister attachment when water is available.
  • If the conditions are dusty, the operator is wearing a dust mask or face mask
  • The unit is in good working condition
  • Conserve water by using power blowers instead of hoses for many lawn and garden applications, including areas such as gutters, screens, patios, grills, porches, and gardens.
  • The tubes and bag are in place and secure

To prevent serious personal injury or damage to the unit, make sure blower tubes or vacuum tubes and the vacuum bag are in place before you operate the unit.

  • Watch out for children, pets, open windows or freshly washed cars, and blow debris safely away.
  • Clean up after using blowers and other equipment. Dispose of debris appropriately.
  • The vacuum bag is installed and zipped closed (when used as a vacuum)

OPERATING TIPS • Be sure the vacuum bag is zipped closed before operating the unit.

AIR VENTS Never cover air vents. Keep them free from obstructions and debris. They must always remain clear for proper motor cooling (Fig. 13).

  • Assure the unit is not directed at anybody or any loose debris before starting the unit.
  • Verify that the unit is in good working condition. Make sure the tubes and guards are in place and secure.
  • Always hold the unit with both hands when operating. Keep a firm grip on both the front and rear handle or grips.
  • To reduce the risk of hearing loss associated with sound level(s), hearing protection is required.

To avoid serious personal injury, do not wear loose fitting clothing or articles such as scarves, strings, chains, ties, etc. that could get drawn into the air vents. To make sure long hair does not get drawn into the air vents secure hair above shoulder level.

Air Vents

Page 11 of the Ryobi RESV1300 user manual — OPERATING AS A BLOWER
Page 11 · cliquer pour agrandir
Page 11

OPERATING AS A BLOWER

Converting to a Blower 1. Place the shoulder harness over your head, onto your shoulder and adjust it if necessary. Refer to Installing the Shoulder Harness.

2. Start the unit. See Starting/Stopping Instructions.
3. Set the blower/vacuum mode change-over lever to the up position (Blower Mode) (Fig. 14).

way between either mode.

Blower Operating Procedures Hold the blower as shown in Figures 15, 16 and 17. Sweep from side to side with the nozzle several inches above the ground or floor. Slowly advance the unit, keeping the accumulated pile of debris in front of you. Most dry blowing operations are better suited to low speeds, rather than high. High speed blowing is a better way to move heavier items like large debris or gravel. 1 Use the blower for trees, shrubs, flower beds and hard-to-clean areas (Fig. 15).

2. Use the unit around buildings and for other normal cleaning procedures (Fig. 16).
3. Use the blower around walls, overhangs, fences and screens (Fig. 17).

Vacuum · Change-over lever · Blower

Page 12 of the Ryobi RESV1300 user manual — OPERATING AS A VACUUM
Page 12 · cliquer pour agrandir
Page 12

OPERATING AS A VACUUM

Converting to Vacuum 1. Place the shoulder harness over your head, onto your shoulder and adjust it if necessary. Refer to Installing the Shoulder Harness.

2. Start the unit. See Starting/Stopping Instructions.
3. Set the blower/vacuum mode change-over lever to the down position (Vacuum Mode) (Fig. 18).

way between either mode.

To avoid serious personal injury, never unzip the vacuum bag without stopping the unit first. WARNING:

As a vacuum, the unit is designed to pick up dry material such as leaves, grass, small twigs and bits of paper. To avoid serious personal injury, do not attempt to vacuum wet debris and/or standing water as this may result in damage to the blower/ vacuum. To avoid severe damage to the impeller, do not vacuum metal, broken glass or similar items.

To prevent serious personal injury or damage to the unit, always install vacuum tubes, the vacuum bag and make sure the vacuum bag is completely zipped closed when operating this unit as a vacuum.

Vacuum Operation Procedures Check for the following before operating the unit: • Operator is wearing proper clothing, such as boots, safety glasses or goggles, ear/hearing protection, gloves, long pants and long sleeve shirt

Avoid situations that could catch the vacuum bag on fire. Do not operate near an open flame. Do not vacuum warm ash from fireplaces, barbecue pits, brush piles, etc. Do not vacuum discarded cigars or cigarettes unless the cinders are completely cool.

  • If the conditions are dusty, operator is equipped with a dust mask or face mask
  • The unit is in good working condition-- the vacuum tubes and vacuum bag are in place and secure.
  • The vacuum bag harness is in place and correctly adjusted

deterioration and obstructing air flow, which will reduce the performance of the vacuum

Use the unit for vacuuming up light debris like leaves and paper. Hold the vacuum, tilting the suction tube slightly (2-4 in or 50-100 mm), and use a sweeping action to collect light debris (Fig. 19). The debris will flow into the vacuum bag. Items such as small leaves and small twigs will be mulched as they pass through the fan housing, allowing the vacuum bag to hold more debris. When the bag is full, suction will noticeably decrease. Turn off the unit and allow the impeller to stop before you unzip the bag. Unzip the bag and empty the contents before continuing. Refer to Emptying the Vacuum Bag.

Show 5 more labels / short text on this page
Vacuum · Mode · Blower · Mode · Change-over lever
Page 13 of the Ryobi RESV1300 user manual — PRESS IN PRESS IN
Page 13 · cliquer pour agrandir
Page 13

CLEARING A BLOCKED TUBE / IMPELLER

EMPTYING THE VACUUM BAG

To avoid serious personal injury, never unzip or remove the vacuum bag without first turning the unit off. WARNING:

To avoid serious personal injury, be sure the unit is off and unplugged before clearing the impeller. WARNING:

deterioration and obstructing air flow, which will reduce the performance of the vacuum.

To avoid serious personal injury, always wear gloves to protect yourself from the impeller blades or other sharp objects. WARNING:

1. Unplug the unit.
2. While pressing the latching tabs on both sides of the vacuum bag tube, pull the vacuum bag down off the unit (Fig. 20).
1. Slide the Power/Speed switch down in the OFF position until the unit comes to a complete stop (Fig. 11).
2. Unplug the unit.

Wear eye protection and a dust mask when emptying the vacuum bag. WARNING:

3. Remove the vacuum bag and then the blower/vacuum tube.
4. Carefully remove material blocking the tube or impeller. Inspect the blades to assure no damage has occurred. Rotate the impeller blades by hand to assure the blockage is completely cleared.
3. Detach the vacuum bag from the vacuum bag hook.
5. Reinstall the blower/vacuum tube and the vacuum bag.
6. Plug the unit back into the power supply.

PRESS IN PRESS IN

4. Unzip the bag and empty the contents into a garbage bag or container.
5. Turn the bag inside out after initial emptying and vigorously shake out dust and debris.
6. Return the bag to outside in, zip the bag closed and reinstall vacuum bag.
7. Plug the unit back into the power supply.

Latching tabs

Page 14 of the Ryobi RESV1300 user manual — CLEANING THE UNIT
Page 14 · cliquer pour agrandir
Page 14

MAINTENANCE AND REPAIR INSTRUCTIONS

SERVICING DOUBLE INSULATED UNITS This unit is double-insulated. In a double-insulated unit, two systems of insulation are provided instead of grounding. There is no grounding provided and no means of grounding should be added to this unit. Extreme care and knowledge of the system is required when servicing a double-insulated unit. Service should be performed by qualified service personnel only. Replacement parts for a double-insulated unit must be identical to the parts they replace. Refer any repair to an authorized service dealer. A double-insulated unit is marked with the words “double insulation” or “double insulated.”

3. Wash the bag once a year or more often if needed:

a. Remove the vacuum bag.

b. Turn bag inside out.

c. Hang it up.

d. Hose it down thoroughly.

e. Hang to dry.

f. Turn bag right-side out and reinstall.

STORAGE • Store the unit locked up to prevent unauthorized use or damage.

  • Store the unit in a dry, well-ventilated area.

CLEANING THE UNIT

  • Store the unit out of the reach of children.

To avoid serious personal injury, always turn your unit off and unplug it before you clean or service it. WARNING:

INSPECT EXTENSION CORDS Inspect all extension cords periodically. Look closely for deterioration, cuts or cracks in the insulation. Inspect the connectors for damage. Replace cords if defective or damaged.

Use a small brush to clean off the outside of the unit. Do not use strong detergents. Household cleaners that contain aromatic oils such as pine and lemon, and solvents such as kerosene, can damage plastic housing or handle. Wipe off any moisture with a soft cloth.

ACCESSORIES/ REPLACEMENT PARTS Vacuum Bag 182416 Blower/Vacuum Tube Assembly 182415 Shoulder Harness 682075

CLEANING THE VACUUM BAG 1. Empty the bag after each use to avoid deterioration and obstructing air flow, which will reduce the performance of the vacuum.

For specific replacement parts, refer to the parts list located on the inside back cover of this manual.

2. Wearing eye protection and a dust mask, clean the bag as needed. Turn the bag inside out after initial emptying and vigorously shake out dust and debris.
Page 15 of the Ryobi RESV1300 user manual — UNIT WILL NOT START
Page 15 · cliquer pour agrandir
Page 15

SPECIFICATIONS

Motor Amperage 12 Amps Blower Air Output up to 160 mph (257.5 kmh) Vacuum Air Flow up to 424 cfm (12 cmm) Mulching Ratio up to 10:1 Operating Weight 10 lb (4.5 kg) Vacuum Bag Capacity 75 bushels (26.4 L)

TROUBLESHOOTING

UNIT WILL NOT BLOW OR VACUUM

C A U S E A C T I O N

Bag full Empty bag, as described in Empty the Vacuum Bag

Blocked tube Clear the blockage as described in Clearing a Blocked Tube/ Impeller

Blocked impeller Clear the blockage as described in Clearing a Blocked Tube/ Impeller

Damaged impeller Take the unit to an authorized service dealer

Dirty bag Clean the vacuum bag

Torn bag Replace the vacuum bag

Bag unzipped Zip up the vacuum bag

Unit unplugged Plug into an outlet or an extension cord

UNIT WILL NOT START

C A U S E A C T I O N

Unit is unplugged Check cord to make sure it is plugged into an electrical outlet

Power/Speed switch is in the OFF position Slide switch to HIGH or LOW

If further assistance is required, contact your authorized service dealer.

Page 16 of the Ryobi RESV1300 user manual — NOTES
Page 16 · cliquer pour agrandir
Page 16

NOTES

Page 17 of the Ryobi RESV1300 user manual — NOTES
Page 17 · cliquer pour agrandir
Page 17

NOTES

Page 18 of the Ryobi RESV1300 user manual — OR 1-800-668-1238 IN CANADA
Page 18 · cliquer pour agrandir
Page 18

MANUFACTURER’S LIMITED WARRANTY FOR:

The limited warranty set forth below is given by MTD LLC (“MTD”) with respect with new merchandise purchased and used in the United States, its possessions and territories. MTD warrants this product against defects in material and workmanship for a period of two (2) years commencing on the date of original purchase and will, at its option, repair or replace, free of charge, any part found to be defective in material or workmanship. This limited warranty shall only apply if this product has been operated and maintained in accordance with the Operator’s Manual furnished with the product, and has not been subject to misuse, abuse, commercial use, neglect, accident, improper maintenance, alteration, vandalism, theft, fire, water or damage because of other peril or natural disaster. Damage resulting from the installation or use of any accessory or attachment not approved by MTD for use with the product(s) covered by this manual will void your warranty as to any resulting damage. This warranty is limited to ninety (90) days from the date of original retail purchase for any MTD product that is used for rental or commercial purposes, or any other income- producing purpose. HOW TO OBTAIN SERVICE: Warranty service is available, WITH PROOF OF PURCHASE THROUGH YOUR LOCAL AUTHORIZED SERVICE DEALER. To locate the dealer in your area, please check for a listing in the Yellow Pages or contact the Customer Service Department of MTD LLC by calling 1-800-345-8746 or writing to P.O. Box 361131, Cleveland OH 44136-0019 or if in Canada call 1-800-668-1238. No product returned directly to the factory will be accepted unless prior written permission has been extended by the Customer Service Department of MTD LLC. This limited warranty does not provide coverage in the following cases: A. Tune-ups - Spark Plugs, Carburetor Adjustments, Filters

No implied warranty, including any implied warranty of merchantability or fitness for a particular purpose, applies after the applicable period of express written warranty above as to the parts as identified. No other express warranty or guaranty, whether written or oral, except as mentioned above, given by any person or entity, including a dealer or retailer, with respect to any product shall bind MTD. During the period of the Warranty, the exclusive remedy is repair or replacement of the product as set forth above. (Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.) The provisions as set forth in this Warranty provide the sole and exclusive remedy arising from the sales. MTD shall not be liable for incidental or consequential loss or damages including, without limitation, expenses incurred for substitute or replacement lawn care services, for transportation or for related expenses, or for rental expenses to temporarily replace a warranted product. (Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.) In no event shall recovery of any kind be greater than the amount of the purchase price of the product sold. Alteration of the safety features of the product shall void this Warranty. You assume the risk and liability for loss, damage, or injury to you and your property and/or to others and their property arising out of the use or misuse or inability to use the product. This limited warranty shall not extend to anyone other than the original purchaser, original lessee or the person for whom it was purchased as a gift. How State Law Relates to this Warranty: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To locate your nearest service dealer dial 1-800-345-8746 in the United States or 1-800-668-1238 in Canada.

B. Wear items - Bump Knobs, Outer Spools,Cutting Line, Inner Reels, Starter Pulley,Starter Ropes, Drive Belts

C. MTD does not extend any warranty for products sold or

MTD LLC P.O. Box 361131 Cleveland, OH 44136-0019

exported outside of the United States of America, its possessions and territories, except those sold through MTD’s authorized channels of export distribution. MTD reserves the right to change or improve the design of any RYOBI Product without assuming any obligation to modify any product previously manufactured.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

FOR QUESTIONS CALL 1-800-345-8746 IN U.S.

OR 1-800-668-1238 IN CANADA

OPERATOR’S MANUAL PART NO. 769-00127A 4/03 PRINTED IN U.S.A.

Page 19 of the Ryobi RESV1300 user manual — MANUEL IMPORTANT À NE PAS JETER
Page 19 · cliquer pour agrandir
Page 19

RESV1300

SOUFFLEUSE/ASPIRATEUR À PAILLER ÉLECTRIQUE

MANUEL DE L'UTILISATEUR

SI VOUS AVEZ DES QUESTIONS, APPELEZ LE 1-800-345-8746 aux ÉTATS-UNIS,

ou le 1-800-668-1238 au CANADA

www.RyobiOutdoor.com

MANUEL IMPORTANT À NE PAS JETER

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Ryobi RESV1300

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Ryobi RESV1300

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Ryobi RESV1300 manuel PDF

56 pages·1.1 MB·Souffleur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…