Manuel d'utilisation / d'entretien du produit Z2510L du fabricant Regency
Aller à la page of 24
FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 908-200 Regency W armHearth High Effi ciency EP A Certifi ed Fireplace MODEL: Z2510L W armHearth Fireplace Ow.
Regency Z2510 W armHearth 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. This product has been certifi ed by the Environmental Protection Agency of the United States.
Regency Z2510 W armHearth 3 T ABLE OF CONTENTS SAFETY LABEL Safety Label for Z2510L ................................................ 4 INST ALLA TION The Regency W armhearth ............................................ 5 Product Details ..............
Regency Z2510 W armHearth 4 SAFETY LABEL FOR Z2510L This is a copy of the label that accompanies each Regency W armHearth. It is located inside the lower louver opening on the left side. We have printed a copy of the contents here for your review . NOTE: Regency units are constantly being improved.
Regency Z2510 W armHearth 5 THE REGENCY W ARMHEARTH 1) Optional 24 Karat Gold-plated Louvers 2) Clean Glass Air W ash System 3) High Safety Ceramic Glass 4) Optional 24 Karat Gold-plated Door 5) Andir.
Regency Z2510 W armHearth 6 Unit Dimensions INST ALLA TION 8) NEVER leave children unattended when there is a fi re burning in the fi replace. 9) Allow the fi replace to cool before servicing. Always shut off any electricity to the fi replace while working on it.
Regency Z2510 W armHearth 7 Framing Specifi cations No Combustibles on Face of Unit Combustibles May Not Extend to Unit Face Do not notch wallboard around standoffs Clearances to Combustibles INST ALLA TION requires a minimum 2 in. (50 mm) clearance.
Regency Z2510 W armHearth 8 HEARTH EXTENSION Note: When the unit is raised 4 inches above the fl oor the Regency Hearth Extension (Part# 000-910) is not required. If you plan to raise the fi replace and hearth extension, build the platform assembly then position fi replace and hearth extension on top.
Regency Z2510 W armHearth 9 V entilated Chase Pan In Canada: Any factory built chimney listed and certifi ed to ULC-S629. Also any of the following chimney covered by ULC-S610 or ULC S604. 1) GSW Heating Products Model JFC 2) Oliver McLeod Ltd. Model PRO-JET3103 3) Security Chimney Ltd.
Regency Z2510 W armHearth 10 INST ALLA TION ASSEMBL Y STEPS Note: The following steps represent the nor- mal sequence of installation. Each installation is unique, however , and might require different steps. Each step is dealt with in detail in the fol- lowing pages.
Regency Z2510 W armHearth 11 or platform for support and to prevent cold air from entering the room from under the fi replace, if against an outside wall. The fi replace may be positioned and then the framing built around it, or the framing may be constructed and the fi replace positioned into the opening.
Regency Z2510 W armHearth 12 be closed during regular operation because the unit uses outside air for combustion, not room air . 2) Multiple T erminations. When you install more than one chimney in the same chase or within the same general area, we suggest that their terminations be separated by at least 16 in.
Regency Z2510 W armHearth 13 INST ALLING THE OUTSIDE AIR KIT Combustion air is fed to the fi rebox through a connection on the rear lower left side of the unit.
Regency Z2510 W armHearth 14 INST ALLA TION GRA VITY AIR FEED KIT OPTION The Gravity Air Feed Kit is designed to extend the heat output vent above the WarmHearth or to the front or the side.
Regency Z2510 W armHearth 15 Central Heat Option Use high temperature silicone to seal the block-off plate to the unit. If necessary drill extra holes in the plate and the unit and secure with extra screws. Note: Make sure the block-off plate is fl ush and fastened tightly to the W armHearth.
Regency Z2510 W armHearth 16 T ypical Floor Register INST ALLA TION be at the top so they lie fl at. Bend out the lower edge of the valve at 4 places inside the fi replace with pliers so that it can't be pulled out again (refer to Diagram 2).
Regency Z2510 W armHearth 17 2" (51mm) x 4" (102mm) Framing Metal Edging . . . . . . . . . . . . . . . . Extend unit past studs so it is flush with sheeting. Drill & T ap screws INST ALLA TION FINISHING THE W ARMHEARTH Completing the Facing Facing materials must be thin veneer (non-self supporting facades) or self supporting facades.
Regency Z2510 W armHearth 18 T op View T op View INST ALLA TION T op View 4) Place side metal fi ller strips in between stove and framing to cover the stand-off space. Fit the strips behind "A" so that they cover the stand-offs, and will prevent mortar from falling through the mesh.
Regency Z2510 W armHearth 19 INST ALLA TION MASONR Y LINER/ BRICKS Insulated refractory panels are included to extend the life of the fi replace and help radiate heat more evenly . Make sure Insulating Paper is in place along the bottom, side and rear before bricks are put into place.
Regency Z2510 W armHearth 20 MAINTENANCE MAINTENANCE Gold Plated Doors and Louvers The optional gold electroplated fi nish on the doors and louvers requires little maintenance and needs only to be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty .
Regency Z2510 W armHearth 21 P ARTS LIST P ARTS LIST - FIREBOX & BODY Part # Description Part # Description 20) 948-102 Spring Handle - Small 21) 000-198 Hearth Extension Connector 22) * Shell Inn.
Regency Z2510 W armHearth 22 P ARTS LIST P ARTS LIST - BAFFLES, DOOR, OPTIONS Part # Description 1) 000-920 Masonry Retainer Kit (Optional) 846-91 1 Door Assembly- Gold 846-917 Door Assembly- Black 3).
Regency Z2510 W armHearth 23 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our door . FPI Fireplace Products International Ltd.
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Insta.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Regency Z2510L c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Regency Z2510L - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Regency Z2510L, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Regency Z2510L va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Regency Z2510L, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Regency Z2510L.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Regency Z2510L. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Regency Z2510L ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.