Manuel d'utilisation / d'entretien du produit L900-LP du fabricant Regency
Aller à la page of 56
Unit requires 120V to operate. See “Wiring Diagram” section in manual for more details. Receptacle is included with manual package. T ested by: FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD.
Regency ® L900 Direct V ent Gas Fireplace 2 T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The L900 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
Regency ® L900 Direct V ent Gas Fireplace 3 T ABLE OF CONTENTS SAFETY LABEL Copy of Safety Decal ..................................................... 4 REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) ........................
Regency ® L900 Direct V ent Gas Fireplace 4 INST ALLA TION SAFETY LABEL This is a copy of the label that accompanies each L900-NG and L900-LP Direct V ent Gas Fireplace.
Regency ® L900 Direct V ent Gas Fireplace 5 INST ALLA TION REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chapter 10 (2) Revise 10.8. 3 by adding the follow ing additiona l requirements: (a) For all s.
Regency ® L900 Direct V ent Gas Fireplace 6 INST ALLA TION UNIT DIMENSIONS.
Regency ® L900 Direct V ent Gas Fireplace 7 INST ALLA TION 12) Installation and any repairs to this appliance should be done by an authorized service person. A professional service person should be called to inspect this appliance annually . Make it a practice to have all of your gas appliances checked annually .
Regency ® L900 Direct V ent Gas Fireplace 8 INST ALLA TION INST ALLA TION This includes: 1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label 48,000 (NG) Btu/h, 46,500 (LP) Btu/h) after burning appliance for 15 minutes. 2) If required, adjusting the primary air to ensure that the fl ame does not carbon.
Regency ® L900 Direct V ent Gas Fireplace 9 INST ALLA TION INST ALLA TION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials.
Regency ® L900 Direct V ent Gas Fireplace 10 INST ALLA TION INST ALLA TION MANTEL CLEARANCES Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram below .
Regency ® L900 Direct V ent Gas Fireplace 11 INST ALLA TION INST ALLA TION Diagram 1 1) Frame in the enclosure for the unit with framing material. The framed opening for the assembled kit is 50-3/4" high x 52" wide x 26-1/2" deep (1289mm x H 1321mm W x 673mm D).
Regency ® L900 Direct V ent Gas Fireplace 12 INST ALLA TION INST ALLA TION SIDE NAILING STRIPS The side nailing strips come attached to the unit. There are 3 plates, one on the top and bottom that can be folded out as required.
Regency ® L900 Direct V ent Gas Fireplace 13 INST ALLA TION V ent restriction is required for certain venting installations, see the diagrams in the "V enting Arrangements" section to determine if they are required for your installation. The V ent Restrictor plate is located on the inside top of the fi rebox.
Regency ® L900 Direct V ent Gas Fireplace 14 INST ALLA TION EXTERIOR VENT TERMINA TION REQUIREMENTS A= Clearance abo ve grade , veranda, porch, deck, or balcony * (min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9" /23cm) C= Clearance to permanently closed window *(min.
Regency ® L900 Direct V ent Gas Fireplace 15 INST ALLA TION INST ALLA TION VENTING ARRANGEMENTS HORIZONT AL TERMINA TION (FLEX) Regency ® Direct V ent System These venting systems, in combination with the L900, have been tested and listed as a direct vent system by W arnock Hersey .
Regency ® L900 Direct V ent Gas Fireplace 16 INST ALLA TION RIGID PIPE VENTING SYSTEMS BASIC HORIZONT AL & VERTICAL TERMINA TIONS Rigid Pipe V ent Systems offer a complete line of component parts for installation of both horizontal and vertical installations.
Regency ® L900 Direct V ent Gas Fireplace 17 INST ALLA TION INST ALLA TION Description Simpson Direct V ent Pro ® Simpson Direct V ent GS ® Discontinued Selkirk Direct-T emp™ Metal-Fab ® Sure Se.
Regency ® L900 Direct V ent Gas Fireplace 18 INST ALLA TION L676 & L900 Direct V ent Fireplace IMPORT ANT NOTE • A V ent Guard is required when the AstroCap is installed above grade at 7 feet or lower. • The Simpson Dura-V ent and Selkirk Direct T emp horizontal termination caps cannot be used in any applications.
Regency ® L900 Direct V ent Gas Fireplace 19 INST ALLA TION VENTING ARRANGEMENTS ALLOW ABLE HORIZONT AL TERMINA TIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 o two 45 o elbows equal one 90 o elbow).
Regency ® L900 Direct V ent Gas Fireplace 20 INST ALLA TION Horizontal V enting with T wo (2) 90 o Elbows Horizontal V enting with Three (3) 90 o Elbows One 90 o elbow = T wo 45 o elbows. Option V H + H1 A) 3' Min. 2' Max. B) 4' Min. 4' Max.
Regency ® L900 Direct V ent Gas Fireplace 21 INST ALLA TION V ertical V enting with Three (3) 90 o Elbows Option V H + H1 V + V1 A) 2' Min. 3' Max. 4' Min. B) 3' Min. 4' Max. 6' Min. C) 4' Min. 5' Max. 8' Min.
Regency ® L900 Direct V ent Gas Fireplace 22 INST ALLA TION VENTING ARRANGEMENTS ALLOW ABLE VERTICAL TERMINA TIONS The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90 o elbows, with Rigid Pipe V enting Systems for Propane and Natural Gas.
Regency ® L900 Direct V ent Gas Fireplace 23 INST ALLA TION INST ALLA TION Diagram 7 Diagram 5 7) Ensure that the pipe clearances to combustible materials are maintained (Diagram 5).
Regency ® L900 Direct V ent Gas Fireplace 24 INST ALLA TION INST ALLA TION 6) Continue to assemble pipe lengths. Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (0.9 meter), to avoid excessive stress on the elbows, and possible separation.
Regency ® L900 Direct V ent Gas Fireplace 25 INST ALLA TION INST ALLA TION 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall.
Regency ® L900 Direct V ent Gas Fireplace 26 INST ALLA TION IN OUT 13 5 6 4 2 GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve d uring any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
Regency ® L900 Direct V ent Gas Fireplace 27 INST ALLA TION 1) Remove the glass door . 3) Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket (located directly above the heat shield). 4) Unplug the power source.
Regency ® L900 Direct V ent Gas Fireplace 28 INST ALLA TION CONVERSION KIT #546-969 FROM NG T O LP LP Conversion Kit Contains: Qty . Part # Description 1 910-462 LP Conversion Coil 1 904-573 Cable T .
Regency ® L900 Direct V ent Gas Fireplace 29 INST ALLA TION 13) Lift up and pull out the heat shield slightly to clear the head screws and then hang it on the top bracket (located directly above the heat shield). Bracket Heat Shield 14) Disconnect the 2 grey connectors from the modulator coil.
Regency ® L900 Direct V ent Gas Fireplace 30 INST ALLA TION 17) Ensure that the new rubber gasket (supplied with coil) is properly positioned and install the new modulating pressure regulator as- sembly to the valve using the screws sup- plied with the kit.
Regency ® L900 Direct V ent Gas Fireplace 31 INST ALLA TION LP Conversion Kit Contains: Qty . Part # Description 1 910-462 LP Conversion Coil 1 904-573 Cable T ie 1 910-037 LP Pilot Orifi ce 1 904-6.
Regency ® L900 Direct V ent Gas Fireplace 32 INST ALLA TION 13) Carefully remove the bottom brick panel. Bottom Brick Panel 14) Loosen the 2 screws that hold the right side heat shield. 15) Lift up and pull out the heat shield slightly to clear the head screws and then hang it on the top bracket (located directly above the heat shield).
Regency ® L900 Direct V ent Gas Fireplace 33 INST ALLA TION 25) Remove the pilot shield by removing the 2 screws. 26) Remove the clip from the pilot head assembly using a fl at head screw driver . 27) Remove the NG pilot orifi ce with the Allen Key and replace with LP pilot orifi ce.
Regency ® L900 Direct V ent Gas Fireplace 34 INST ALLA TION BRICK P ANEL INST ALLA TION IMPORT ANT : Must install 1 set of brick panels. The operation of this unit without the brick panels is prohibited. Dangerous operating conditions may occur if the panels are broken.
Regency ® L900 Direct V ent Gas Fireplace 35 INST ALLA TION 7) Slide the left side brick panel into position and secure in place with the brick panel clip that was removed in step 3. 1) Ensure installation of the logs and glass door has been completed before installing the exterior brick panels.
Regency ® L900 Direct V ent Gas Fireplace 36 INST ALLA TION LOG SET INST ALLA TION Installation of Interior Brick Panels must be completed before installing the log set. INST ALLA TION Read the instructions below carefully and refer to the diagrams. If the logs are broken do not use the unit until they are replaced.
Regency ® L900 Direct V ent Gas Fireplace 37 INST ALLA TION INST ALLA TION 8) Spread all of the Embers on the bottom brick panel around the burner tube and on the inside of the grate as shown. 9) Spread the vermiculite on the base brick panel covering the remaining exposed base brick.
Regency ® L900 Direct V ent Gas Fireplace 38 INST ALLA TION INST ALLA TION WIRING DIAGRAM A receptacle is provided on the left hand side of the unit. 120 V olt AC power must be wired to the receptacle and the control module plugged in for the unit to operate fully .
Regency ® L900 Direct V ent Gas Fireplace 39 OPERA TION OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks.
Regency ® L900 Direct V ent Gas Fireplace 40 OPERA TION OPERA TING INSTRUCTIONS NOTE: The control knob is located on the right hand side of the fi rebox behind the right side exterior brick panel. 1) Push in gas control knob slightly and turn clockwise to “OFF”.
Regency ® L900 Direct V ent Gas Fireplace 41 OPERA TION OPERA TING INSTRUCTIONS COPY OF LIGHTING PLA TE INSTRUCTIONS TO TURN OFF GAS APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1) Push in gas control knob slightly and turn clockwise to “OFF”.
Regency ® L900 Direct V ent Gas Fireplace 42 MAINTENANCE MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year .
Regency ® L900 Direct V ent Gas Fireplace 43 MAINTENANCE MAINTENANCE 1) Remove the exterior brick panels. 2) Remove the glass door . 4) Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket (located directly above the heat shield).
Regency ® L900 Direct V ent Gas Fireplace 44 MAINTENANCE MAINTENANCE 6 ) Remove the top screw and loosen the bottom screw that hold the power module in place. 7) Remove the power module cover by removing the 2 screws, one on each side. 8) Remove the 3 connectors from the circuit board.
Regency ® L900 Direct V ent Gas Fireplace 45 MAINTENANCE MAINTENANCE 6) Cut the cable tie that is holds the wires connected to the control module. 7) Disconnect the 3 connectors from the control module. 8) Pull out the control module. NOTE: The control module is held in place with velcro.
Regency ® L900 Direct V ent Gas Fireplace 46 MAINTENANCE MAINTENANCE 3) Loosen the 2 screws that hold the left side heat shield in place. 4) Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket (located directly above the heat shield).
Regency ® L900 Direct V ent Gas Fireplace 47 MAINTENANCE 1) Remove the exterior brick panels. 2) Remove the glass door . V AL VE TRA Y REPLACEMENT a. Release the 2 door latches on the left and right side at the top of the fi rebox. b. Swing the door out from the top and release the hinges on the left and right side of the door by lifting them up.
Regency ® L900 Direct V ent Gas Fireplace 48 MAINTENANCE 21) Replace the valve tray and reverse steps to re-install. 22) T urn on the gas supply and check for gas leaks. 23) Plug in the power source. 24) Re-install the left heat shield. 25) Re-install the grate.
Regency ® L900 Direct V ent Gas Fireplace 49 P AR TS LIST P ARTS LIST MAIN ASSEMBL Y Part # Description 1) 521-527 Flue Collar Inner Assembly 2) 502-008 Flue Collar Outer 5) 904-751 Capscrew 1/4 x 4-.
Regency ® L900 Direct V ent Gas Fireplace 50 P AR TS LIST P ARTS LIST.
Regency ® L900 Direct V ent Gas Fireplace 51 P AR TS LIST BURNER & LOG ASSEMBL Y Part # Description 30) 521-015 Bracket Log T ray 31) 546-016 Log T ray 32) 546-042 Defl ector Log T ray 35) 948-4.
Regency ® L900 Direct V ent Gas Fireplace 52 NOTES.
Regency ® L900 Direct V ent Gas Fireplace 53 NOTES.
Regency ® L900 Direct V ent Gas Fireplace 54 NOTES.
Regency ® L900 Direct V ent Gas Fireplace 55 W ARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam care fully inspects each unit thoroughly before it leaves our facility .
Regency ® L900 Direct V ent Gas Fireplace 56 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Regency L900-LP c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Regency L900-LP - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Regency L900-LP, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Regency L900-LP va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Regency L900-LP, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Regency L900-LP.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Regency L900-LP. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Regency L900-LP ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.