Manuel d'utilisation / d'entretien du produit L900-1 du fabricant Regency
Aller à la page of 48
T ested by: FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-726a MODELS: L900-NG1 Natural Gas L900-LP1 Propane FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch: do not use any phone in your building.
Regency ® L900-1 Direct V ent Gas Fireplace 2 T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The L900-1 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
Regency ® L900-1 Direct V ent Gas Fireplace 3 T ABLE OF CONTENTS SAFETY LABEL Copy of Safety Decal ..................................................... 4 REQUIREMENTS MA Code - CO Detector................................................. 5 UNIT DIMENSIONS Unit Dimensions .
Regency ® L900-1 Direct V ent Gas Fireplace 4 INST ALLA TION SAFETY LABEL This is a copy of the label that accompanies each L900-NG1 and L900-LP1 Direct V ent Gas Fireplace. We have printed a copy of the contents here for your review . The safety label is located on the left hand side of the unit behind the mesh screen.
Regency ® L900-1 Direct V ent Gas Fireplace 5 INST ALLA TION REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chapter 10 (2) Revise 10.8. 3 by adding the follow ing additiona l requirements: (a) For all.
Regency ® L900-1 Direct V ent Gas Fireplace 6 INST ALLA TION UNIT DIMENSIONS.
Regency ® L900-1 Direct V ent Gas Fireplace 7 INST ALLA TION 12) Installation and any repairs to this appliance should be done by an authorized service person. A professional service person should be called to inspect this appliance annually . Make it a practice to have all of your gas appliances checked annually .
Regency ® L900-1 Direct V ent Gas Fireplace 8 INST ALLA TION INST ALLA TION This includes: 1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label 41,500 (NG) Btu/h, 38,500 (LP) Btu/h) after burning appliance for 15 minutes.
Regency ® L900-1 Direct V ent Gas Fireplace 9 INST ALLA TION INST ALLA TION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials.
Regency ® L900-1 Direct V ent Gas Fireplace 10 INST ALLA TION INST ALLA TION MANTEL CLEARANCES Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram below .
Regency ® L900-1 Direct V ent Gas Fireplace 11 INST ALLA TION INST ALLA TION Diagram 1 1) Frame in the enclosure for the unit with framing material. The framed opening for the assembled kit is 50-3/4" high x 52" wide x 26-1/2" deep (1289mm x H 1321mm W x 673mm D).
Regency ® L900-1 Direct V ent Gas Fireplace 12 INST ALLA TION INST ALLA TION SIDE NAILING STRIPS The side nailing strips come attached to the unit. There are 2 plates on each side, one on the top and bottom that can be folded out as required.
Regency ® L900-1 Direct V ent Gas Fireplace 13 INST ALLA TION V ent restriction is required for certain venting installations, see the diagrams in the "V enting Arrangements" section to determine if they are required for your installation. The V ent Restrictor plate is located on the inside top of the fi rebox.
Regency ® L900-1 Direct V ent Gas Fireplace 14 INST ALLA TION EXTERIOR VENT TERMINA TION REQUIREMENTS INST ALLA TION Minimum Clearance Requirements Canada 1 USA 2 A Clearance abov e grade , veranda, .
Regency ® L900-1 Direct V ent Gas Fireplace 15 INST ALLA TION INST ALLA TION VENTING ARRANGEMENTS HORIZONT AL TERMINA TION (FLEX) Regency ® Direct V ent System These venting systems, in combination with the L900-1, have been tested and listed as a direct vent system by W arnock Hersey .
Regency ® L900-1 Direct V ent Gas Fireplace 16 INST ALLA TION RIGID PIPE VENTING SYSTEMS BASIC HORIZONT AL & VERTICAL TERMINA TIONS Rigid Pipe V ent Systems of fer a complete line of component parts for installation of both horizontal and vertical installations.
Regency ® L900-1 Direct V ent Gas Fireplace 17 INST ALLA TION INST ALLA TION 5” X 8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed.
Regency ® L900-1 Direct V ent Gas Fireplace 18 INST ALLA TION INST ALLA TION.
Regency ® L900-1 Direct V ent Gas Fireplace 19 INST ALLA TION VENTING ARRANGEMENTS ALLOW ABLE HORIZONT AL TERMINA TIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 o two 45 o elbows equal one 90 o elbow).
Regency ® L900-1 Direct V ent Gas Fireplace 20 INST ALLA TION Horizontal V enting with T wo (2) 90 o Elbows Horizontal V enting with Three (3) 90 o Elbows One 90 o elbow = T wo 45 o elbows. Option V H + H1 A) 2' Min. 4' Max. B) 3' Min.
Regency ® L900-1 Direct V ent Gas Fireplace 21 INST ALLA TION V ertical V enting with Three (3) 90 o Elbows INST ALLA TION Option V H + H1 V + V1 A) 2' Min. 2' Max. 4' Min. B) 3' Min. 4' Max. 6' Min. C) 4' Min. 5' Max.
Regency ® L900-1 Direct V ent Gas Fireplace 22 INST ALLA TION VENTING ARRANGEMENTS ALLOW ABLE VERTICAL TERMINA TIONS The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90 o elbows, with Rigid Pipe V enting Systems for Propane and Natural Gas.
Regency ® L900-1 Direct V ent Gas Fireplace 23 INST ALLA TION INST ALLA TION Diagram 7 Diagram 5 7) Ensure that the pipe clearances to combustible materials are maintained (Diagram 5).
Regency ® L900-1 Direct V ent Gas Fireplace 24 INST ALLA TION INST ALLA TION 6) Continue to assemble pipe lengths. Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (0.9 meter), to avoid excessive stress on the elbows, and possible separation.
Regency ® L900-1 Direct V ent Gas Fireplace 25 INST ALLA TION INST ALLA TION 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall.
Regency ® L900-1 Direct V ent Gas Fireplace 26 INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
Regency ® L900-1 Direct V ent Gas Fireplace 27 INST ALLA TION WIRING DIAGRAM AERA TION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue fl ame or close for a more yellow fl ame.
Regency ® L900-1 Direct V ent Gas Fireplace 28 INST ALLA TION CONVERSION KIT #547-969 FROM NG T O LP INST ALLA TION LP Conversion Kit Contains: Qty . Part # Description 1 910-582 LP Conversion Coil 1.
Regency ® L900-1 Direct V ent Gas Fireplace 29 INST ALLA TION 8) Remove the NG pilot orifice with the 5/32 Allen Key and replace with LP pilot orifi ce. 9) Re-install the pilot cap. 13) Install the enclosed identifi cation label to the valve body where it can be easily seen.
Regency ® L900-1 Direct V ent Gas Fireplace 30 INST ALLA TION BRICK P ANEL INST ALLA TION IMPORT ANT : Must install 1 set of brick panels. The operation of this unit without the brick panels is prohibited. Dangerous operating conditions may occur if the panels are broken.
Regency ® L900-1 Direct V ent Gas Fireplace 31 INST ALLA TION 9) Slide the left side brick panel into position and secure in place with the 2nd brick panel clip that was removed in step 5. T op Brick Panel T op Brick Panel Right Side Brick Panel L900-1 Brick Panel Clip Brick Panel Clip - L676-1 only .
Regency ® L900-1 Direct V ent Gas Fireplace 32 INST ALLA TION LOG SET INST ALLA TION Installation of Brick Panels must be completed before installing the log set. Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced.
Regency ® L900-1 Direct V ent Gas Fireplace 33 INST ALLA TION 7) Rest the notch on the bottom left side of log C onto the 3rd grate post and rest the right side of log C on the 4th grate post. 6) Fit log D into the pin on the far left side of log A. 3rd Grate Post 4th Grate Post A D A D C C 5) Fit log A into the pins on the log tray .
Regency ® L900-1 Direct V ent Gas Fireplace 34 INST ALLA TION 8) Rest the notches on the underside log B onto the 1st and 2nd grate post. 9) Fit the top of log F into the pin on the far right side of log A and rest the bottom end of of log F on log C.
Regency ® L900-1 Direct V ent Gas Fireplace 35 INST ALLA TION Completed Log Set Installation G A D C B F E G 11 ) Rest the cut-out in log G onto the notch in log B.
Regency ® L900-1 Direct V ent Gas Fireplace 36 INST ALLA TION MESH PULL SCREEN INST ALLA TION 1) Hang the right side mesh screen on the right side rod by placing the rings on the mesh screen thru the rod.
Regency ® L900-1 Direct V ent Gas Fireplace 37 INST ALLA TION INST ALLA TION Optional Andiron installation for the L900-1: 1) Remove the mesh and the glass door (see Page 30 in the manual). 2) Remove Log G from the log set - see below . Optional Andiron installation for the L676-1: 1) Remove the mesh and the glass door (see Page 30 in the manual).
Regency ® L900-1 Direct V ent Gas Fireplace 38 OPERA TION OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks.
Regency ® L900-1 Direct V ent Gas Fireplace 39 OPERA TION OPERA TING INSTRUCTIONS COPY OF LIGHTING PLA TE INSTRUCTIONS TO TURN OFF GAS APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1) Push in gas control knob slightly and turn clockwise to “OFF”.
Regency ® L900-1 Direct V ent Gas Fireplace 40 MAINTENANCE MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year .
Regency ® L900-1 Direct V ent Gas Fireplace 41 MAINTENANCE MAINTENANCE 2) Disconnect the 2 DC Spark generator wires from the DC spark box located on the right side of the fi rebox. DC SP ARK BOX REPLACEMENT 5) Replace the DC spark box. 6) Reverse steps to re-install.
Regency ® L900-1 Direct V ent Gas Fireplace 42 MAINTENANCE V AL VE TRA Y REPLACEMENT 5) Remove the log set. 6) Remove the brick panels. 7) Remove the grate by undoing the 4 screws, 2 on each side. 8) Remove the burner tube by removing the 2 screws. 9) Remove the rear log stand by removing the 4 screws.
Regency ® L900-1 Direct V ent Gas Fireplace 43 MAINTENANCE 13) Unplug the green (TH) and white (TP/TH) wires from the valve. 14) Disconnect the 2 DC Spark generator wires from the DC spark box located in front of the valve. 15) Disconnect the spark electrode wire from the DC spark box.
Regency ® L900-1 Direct V ent Gas Fireplace 44 P ARTS LIST P ARTS LIST MAIN ASSEMBL Y Part # Description 1) 521-527 Flue Collar Inner Assembly 2) 502-008 Flue Collar Outer 5) 904-751 Capscrew 1/4 x 4.
Regency ® L900-1 Direct V ent Gas Fireplace 45 P ARTS LIST P ARTS LIST.
Regency ® L900-1 Direct V ent Gas Fireplace 46 P ARTS LIST BURNER & LOG ASSEMBL Y P ARTS LIST Part # Description 31) 547-016 Log T ray 33) 547-015 Ember T ray 34) 522-017F Ember Plate 35) 948-466.
Regency ® L900-1 Direct V ent Gas Fireplace 47 W ARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility .
Regency ® L900-1 Direct V ent Gas Fireplace 48 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ _________________________.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Regency L900-1 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Regency L900-1 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Regency L900-1, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Regency L900-1 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Regency L900-1, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Regency L900-1.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Regency L900-1. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Regency L900-1 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.