Manuel d'utilisation / d'entretien du produit B36X du fabricant Regency
Aller à la page of 64
W ARNING: If the information in these instructions are not followed exactly , a fi re or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
2 Regency Bellavista™ B36X Gas Fireplace T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The Bellavista™ B36X has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
3 Regency Bellavista™ B36X Gas Fireplace T ABLE OF CONTENTS SAFETY LABEL Copy of Safety Decal ..................................................... 4 REQUIREMENTS MA Code - CO Detector................................................. 5 DIMENSIONS Unit Dimensions .
4 Regency Bellavista™ B36X Gas Fireplace SAFETY LABEL This is a copy of the label that accompanies each Bellavista™ B36X Direct V ent Gas Fireplace. We have printed a copy of the contents here for your review . NOTE: Regency ® units are constantly being improved.
5 Regency Bellavista™ B36X Gas Fireplace REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chap ter 10 (2) Revise 10.8. 3 by adding the following a dditional requi rements: (a) For all side wall hor izo.
6 Regency Bellavista™ B36X Gas Fireplace DIMENSIONS UNIT DIMENSIONS 37-1/2” (953mm) 21”(533mm) 33” (838mm) 36” (914mm) 35-1/4” (895mm) 30-3/8” (762mm) 1”(25.
7 Regency Bellavista™ B36X Gas Fireplace 11 ) Under no circumstances should this appliance be modi fi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance. 12) Installation and any repairs to this appliance should be done by a quali fi ed service person.
8 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION This includes: 1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label) after burning appliance for 15 minutes. 2) If required, adjusting the primary air to ensure that the fl ame does not carbon.
9 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION Caution Requirements The top, back and sides of the fi replace are de fi ned by standoffs. The metal ends of the standoff may NOT be recessed into combustible construction. W ARNING Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to.
10 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION MANTEL CLEARANCES Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour .
11 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION FRAMING M N O Q P R U V T Opening for gas connection 1 1" (279mm) dia. Hole through wall V ent.
12 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION FINISHING Diagram 2 Diagram 1 IMPORT ANT FINISHING DET AIL NOTE: Before placing unit into fi nal position - it is important to know the total thickness / height of fi nished hearth (tile, carpet, etc.
13 Regency Bellavista™ B36X Gas Fireplace BEFORE YOU ST ART The T op Facing Support, the Side Nailing Strips, the 2 T op Standoffs and the Flue Collar must be correctly positioned and attached before the fi replace is moved into position.
14 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION TOP FLUE COLLAR INST ALLA TION Note: This conversion must be done prior to the unit being placed in position. The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented.
15 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION 6) From the outside top of the fi rebox, remove the intake collar plate by removing the 4 - 1/4" x 1/2 " screws. See Diagram 6. 5) From the outside rear of the fi rebox, remove the intake collar assembly .
16 Regency Bellavista™ B36X Gas Fireplace EXTERIOR VENT TERMINA TION REQUIREMENTS INST ALLA TION Minimum Clearance Requirements Canada 1 USA 2 A Clearance abov e grade , ver anda, porch, deck, or ba.
17 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION APPROVED VENTING CONFIGURA TIONS HORIZONT AL & VERTICAL TERMINA TIONS.
18 Regency Bellavista™ B36X Gas Fireplace APPROVED VENTING CONFIGURA TIONS HORIZONT AL & VERTICAL TERMINA TIONS INST ALLA TION V ertical Venting Configurations V ertical Rear V ent Flex V ent 4&.
19 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION RIGID PIPE CROSS REFERENCE CHART 4" X 6-5/8" (MUST USE VENT REDUCER # 946-606 AND RIGID PIPE ADAPT OR #770-994) Components from different Manufacturers may not be mixed. Not all Rigid Pipe components are available directly from FPI.
20 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION.
21 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION RIGID PIPE CROSS REFERENCE CHART 5" X 8" Components from different Manufacturers may not be mixed.
22 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION.
23 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION HORIZONT AL TERMINA TIONS REGENCY ® DIRECT VENT FLEX SYSTEM (5" X 8") These venting systems, in combination with the B36X Direct V ent Gas Fireplace, has been tested and listed as a direct vent heat er system by W arnock Hersey .
24 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION Rigid Pipe Adaptor Pipe Length 90 Elbow o Horizontal T ermination Cap W all Thimble Vinyl Siding Standoff (Optional) Rigid Pipe Adaptor Pipe .
25 Regency Bellavista™ B36X Gas Fireplace Pipe Length V ertical T ermination Cap Storm Collar Flashing Ceiling Firestop Rigid Pipe Adaptor Pipe Length Pipe Length 90 Elbow o Astrocap (946-523/P) W a.
26 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION Rigid Pipe Adaptor Pipe Length Astrocap XL W all Thimble Vinyl Siding Standoff (Optional) 45 elbow 0 Designed for a minimum vent confi guration when using a rear vent application with a horizontal termination in a corner installation.
27 Regency Bellavista™ B36X Gas Fireplace VENTING ARRANGEMENTS ALLOW ABLE VERTICAL TERMINA TIONS (MUST USE VENT REDUCER # 946-606 & RIGID PIPE ADAPTOR #770-994) 4" X 6 - 5/8" PIPE VENT.
28 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION HORIZONT AL VENTING WITH TWO (2) 90 O ELBOWS (RIGID PIPE 4" X 6 - 5/8") 16 2 2 0 0 12 12 6 6 18 4 49" (1245mm) Minimum Height .
29 Regency Bellavista™ B36X Gas Fireplace HORIZONT AL VENTING WITH THREE (3) 90 O ELBOWS (RIGID PIPE 4" X 6 - 5/8") V1 H1 H V Lengths do not include elbow indicated. Must use reducer # 946-606 and rigid pipe adaptor #770-994. Option V H V + V1 H + H1 A) 0' Min.
30 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION VERTICAL TERMINA TION WITH CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEP ARA TE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney .
31 Regency Bellavista™ B36X Gas Fireplace VENTING ARRANGEMENT - VERTICAL TERMINA TIONS CO-LINEAR FLEX SYSTEM INT O MASONR Y FIREPLACES FOR BOTH RESIDENTIAL & MANUF ACTURED HOMES The shaded area in the diagrams show the allowable vertical terminations.
32 Regency Bellavista™ B36X Gas Fireplace Diagram 7 Diagram 5 7) Ensure that the pipe clearances to combustible materials are maintained (Diagram 5).
33 Regency Bellavista™ B36X Gas Fireplace on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls.
34 Regency Bellavista™ B36X Gas Fireplace GAS LINE INST ALLA TION The gas line is brought through the right side of the appliance. The gas valve is situated on the right hand side of the unit and the gas inlet is on the right hand side of the valve.
35 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
36 Regency Bellavista™ B36X Gas Fireplace WIRING DIAGRAM AERA TION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue fl ame or close for a more yellow fl ame.
37 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION Lockwasher Fan ground wire Nut #8 Ground Lug (for mobile home) Star washer T o Thermocouple IN Pilot Assembly H I L O O F F O N P I L O T Gas.
38 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION VENT RESTRICT OR, BAFFLE & HEA T DEFLECTOR INST ALLA TION NOTE: THE VENT RESTRICTOR & BAFFLE MUST BE INST ALLED PRIOR TO OPTIONAL BRICK P ANEL INST ALLA TION. Note: If installing brick panels, see brick panel instructions before proceeding to next step.
39 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION CONVERSION KIT# 556-969 FROM NG T O LP for B36X using SIT 820 NOV A Gas V alve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 1) Shut off the gas supply .
40 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION 18) V erify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o-ring visible (Fig. 5). 19) R e-assemble the black protection cap (Fig. 6). LPG Configuration Red o-ring visible Fig.
41 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION DC Sparker Battery Replacement 23) Locate the Piezo Ignitor situated at the right side of the valve assembly . 24) Remove the Piezo Ignitor wire from the back of the Piezo Ignitor . 25) Connect the ignitor wire from the Piezo to the DC sparker .
42 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION Dangerous operating conditions may occur if the panels are broken. Handle with care. DO NOT FORCE INTO POSITION. 1) Unwrap the Brick Panels from the protective wrapping. 2) Ensure that the logs are not in the unit.
43 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION OPTIONAL ST AINLESS STEEL / BLACK ENAMEL P ANEL INST ALLA TION 1 ) Remove the heat defl ector by removing the 2 screws securing the h eat defl ector to the top of the fi rebox (see Diagram 2).
44 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION 5) Repeat step 4 for left side panel. 5) Repeat step 4 for left side panel. 6) Reverse step 1.
45 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION LOG SET INST ALLA TION Installation of Brick Panels must be completed before installing the log set. Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced.
46 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION B F A B F C A F B C D 5th Grate T ab 2nd Grate T ab Notch in log B Notch in log F 5) Place Log F on the front left side of the burner . Push the back of the log against the 2 front brackets with the notch on the bottom of the log fi tting into the fi rst grate tab.
47 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION E A B C D F B A F C D E Lava Rocks Platinum Embers Notch in log D 9) Place the lava rocks on the front of the burner tray in the places shown in the photo. Separate platinum embers and place on the front burner on and around the lava rocks.
48 Regency Bellavista™ B36X Gas Fireplace W ALL SWITCH (INCLUDED) 1) Run the supplied 10' of wire through the right or left side gas inlet opening. Be careful not to damage wire. Note: We recommend a maximum of 10' of wire but if you wish to go with a longer run, use the Thermostat Wire T able.
49 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION Note: Regency Profl ame wall switches are white (not black as shown)..
50 Regency Bellavista™ B36X Gas Fireplace F AN INST ALLA TION INST ALLA TION Important: 120 V olt AC power is needed for the fan switch and blower . The receptacle box will be installed on the left hand side of the unit and will need to be wired by a qualifi ed electrician prior to fan assembly being installed.
51 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION FLUSH GLASS DOOR INST ALLA TION 1) Line up slots on fl ush glass door with tabs in fi rebox. Hook slots on to tabs and lower door slowly (See Diagram 1). 2) Lower the fl ush door , then hook the 2 adjustable tension latches - close the latches to secure the fl ush door(See Diagram 2).
52 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION Finishing T rim T op Finishing T rim Side NOTE: Install the Finishing T rim prior to installing the Flush Louvers. 1) Install the Finishing T rim sides as shown in the diagram; line up the holes in the side trim with the holes in the fi rebox side.
53 Regency Bellavista™ B36X Gas Fireplace INST ALLA TION FULL SCREEN ARCH DOOR AND FRAME INST ALLA TION Diagram 1 Diagram 2 Diagram 4 Diagram 3a Diagram 3b Diagram 5 Final Screen Install 1) Remove glass door (refer to glass door removal in the manual).
54 Regency Bellavista™ B36X Gas Fireplace OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks.
55 Regency Bellavista™ B36X Gas Fireplace OPERA TING INSTRUCTIONS COPY OF LIGHTING PLA TE INSTRUCTIONS OFF a.
56 Regency Bellavista™ B36X Gas Fireplace MAINTENANCE 2) Remove the Cap, and shine a fl ashlight down the V ent. Remove any bird nests, or other foreign material.
57 Regency Bellavista™ B36X Gas Fireplace MAINTENANCE REMOVING V AL VE 10) Remove the 8 Phillips head screws securing the valve tray assembly in place (Diagram 6) and then lift the entire assembly out (Diagram 7). 1) Shut off the gas supply . 2) Remove the louvers 3) Open the fl ush door and remove the door .
58 Regency Bellavista™ B36X Gas Fireplace P ARTS LIST MAIN ASSEMBL Y Part # Description 1) 556-524 Flue Collar Outer Assembly 2) 556-085 Flue Collar Gasket 3) 556-097 Exhaust Gasket 4) 556-513 Flue .
59 Regency Bellavista™ B36X Gas Fireplace P ARTS LIST MAIN ASSEMBL Y 21 F AN SWITCH ASSEMBL Y FA N SWITCH ASSEMBL Y 20 18 19 1 2 3 4 11 5 6 14 15 12 10 8 9 16 7 13 17 HEA T WA VE DUCT KIT HEA T WA V.
60 Regency Bellavista™ B36X Gas Fireplace BURNER ASSEMBL Y 1 2 4 3 5 6 7 9 10 P ARTS LIST Part # Description 1) 556-077 Rear Log T ray 2) 904-532 Insert 3) 556-525 B36X Burner Assembly 4) 556-057 B3.
61 Regency Bellavista™ B36X Gas Fireplace NOTES.
62 Regency Bellavista™ B36X Gas Fireplace NOTES.
63 Regency Bellavista™ B36X Gas Fireplace W ARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility .
64 Regency Bellavista™ B36X Gas Fireplace Installer: Please complete the following information Dealer Name & Address: ______________________________________________ _____________________________.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Regency B36X c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Regency B36X - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Regency B36X, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Regency B36X va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Regency B36X, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Regency B36X.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Regency B36X. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Regency B36X ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.