FR
Powermatic logo
Notice d'utilisation officielle

Powermatic PM1900TX

60 pages·3 MB·Collecteur de poussière·PDF·ENDEITNLJA
Powermatic PM1900TX
Table des matières 32 sections PM1900TX Dust Collector · Warranty and Service · Table of Contents · Warnings · … AfficherMasquer
Page 1 of the Powermatic PM1900TX user manual — Instructions and Parts Manual PM1900TX Dust Collector
Page 1 · cliquer pour agrandir
Page 1

This .pdf document is bookmarked

Powermatic PM1900TX — PM1900TX Dust Collector diagram (page 1)
Fig. 1 · PM1900TX Dust Collector
Powermatic PM1900TX — PM1900TX Dust Collector diagram (page 1)
Fig. 2 · PM1900TX Dust Collector

Instructions and Parts Manual PM1900TX Dust Collector

Powermatic PM1900TX — Instructions and Parts Manual PM1900TX Dust Collector diagram (page 1)
Fig. 3 · Instructions and Parts Manual PM1900TX Dust Collecto…

PM1900TX with Filter Bag Kit (1792071K) PM1900TX with Canister Kit (1792072K)

Powermatic 427 New Sanford Road LaVergne, TN 37086 Part No. M-1792071 Ph.: 800-274-6848 Revision A4 02/2014 www.powermatic.com Copyright © 2014 Powermatic

Now with

Page 2 of the Powermatic PM1900TX user manual — Warranty and Service
Page 2 · cliquer pour agrandir
Page 2

Warranty and Service

Powermatic warrants every product it sells against manufacturers’ defects. If one of our tools needs service or repair, please contact Technical Service by calling 1-800-274-6846, 8AM to 5PM CST, Monday through Friday.

Warranty Period The general warranty lasts for the time period specified in the literature included with your product or on the official Powermatic branded website.

  • Powermatic products carry a limited warranty which varies in duration based upon the product. (See chart below)
  • Accessories carry a limited warranty of one year from the date of receipt.
  • Consumable items are defined as expendable parts or accessories expected to become inoperable within a reasonable amount of use and are covered by a 90 day limited warranty against manufacturer’s defects.

Who is Covered This warranty covers only the initial purchaser of the product from the date of delivery.

What is Covered This warranty covers any defects in workmanship or materials subject to the limitations stated below. This warranty does not cover failures due directly or indirectly to misuse, abuse, negligence or accidents, normal wear-and-tear, improper repair, alterations or lack of maintenance.

Warranty Limitations Woodworking products with a Five Year Warranty that are used for commercial or industrial purposes default to a Two Year Warranty. Please contact Technical Service at 1-800-274-6846 for further clarification.

explain and assist with any additional action needed. Powermatic hasAuthorized Service Centers located throughout the United States. For the name of an Authorized Service Center in your area call 1-800-274-6846 or use the Service Center Locator on the Powermatic website.

More Information Powermatic is constantly adding new products. For complete, up-to-date product information, check with your local distributor or visit the Powermatic website.

How State Law Applies This warranty gives you specific legal rights, subject to applicable state law.

Limitations on This Warranty POWERMATIC LIMITS ALL IMPLIED WARRANTIES TO THE PERIOD OF THE LIMITED WARRANTY FOR EACH PRODUCT. EXCEPT AS STATED HEREIN, ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXCLUDED. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. POWERMATIC SHALL IN NO EVENT BE LIABLE FOR DEATH, INJURIES TO PERSONS OR PROPERTY, OR FOR INCIDENTAL, CONTINGENT, SPECIAL, OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF OUR PRODUCTS. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. Powermatic sells through distributors only. The specifications listed in Powermatic printed materials and on the official Powermatic website are given as general information and are not binding. Powermatic reserves the right to effect at any time, without prior notice, those alterations to parts, fittings, and accessory equipment which they may deem necessary for any reason whatsoever.

Product Listing with Warranty Period

90 Days – Parts; Consumable items 1 Year – Motors, Machine Accessories 2 Year – Woodworking Machinery used for industrial or commercial purposes 5 Year – Woodworking Machinery

Page 4 of the Powermatic PM1900TX user manual — Warnings
Page 4 · cliquer pour agrandir
Page 4
Powermatic PM1900TX — Warnings diagram (page 4)
Fig. 4 · Warnings
2. Read and understand the warnings posted on the machine and in this manual. Failure to comply with all of these warnings may cause serious injury.
3. Replace the warning labels if they become obscured or removed.
4. This dust collector is designed and intended for use by properly trained and experienced personnel only. If you are not familiar with the proper and safe operation of a dust collector, do not use until proper training and knowledge have been obtained.
5. Do not use this dust collector for other than its intended use. If used for other purposes, Powermatic disclaims any real or implied warranty and holds itself harmless from any injury that may result from that use.
6. Always wear approved safety glasses/face shields while using this dust collector. Everyday eyeglasses only have impact resistant lenses; they are not safety glasses.
7. Keep hair, loose clothing, fingers, and all parts of body away from opening and moving parts.
8. Wear ear protectors (plugs or muffs) during extended periods of operation.
9. Some dust created by power sanding, sawing, grinding, drilling and other construction activities contains chemicals known to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are:
  • Lead from lead based paint.
  • Crystalline silica from bricks, cement and other masonry products.
  • Arsenic and chromium from chemically treated lumber.

Your risk of exposure varies, depending on how often you do this type of work. To reduce your exposure to these chemicals, work in a well-ventilated area and work with approved safety equipment, such as face or dust masks that are specifically designed to filter out microscopic particles.

10. Do not operate this machine while tired or under the influence of drugs, alcohol or any medication.
11. Make certain the switch is in the OFF position before connecting the machine to the power supply. Turn off all controls before unplugging.
12. Make certain the machine is properly grounded. Connect to a properly grounded outlet only.
13. Make all machine adjustments or maintenance with the machine unplugged from the power source.
14. Remove adjusting keys and wrenches. Form a habit of checking to see that keys and adjusting wrenches are removed from the machine before turning it on.
15. Keep safety guards in place at all times when the machine is in use. If removed for maintenance purposes, use extreme caution and replace the guards immediately after maintenance is complete.
16. Check damaged parts. Before further use of the machine, a guard or other part that is damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment of moving parts, binding of moving parts, breakage of parts, mounting and any other conditions that may affect its operation. A guard or other part that is damaged should be properly repaired or replaced.
17. Provide for adequate space surrounding work area and non-glare, overhead lighting.
18. Keep the floor around the machine clean and free of scrap material, oil and grease.
19. Keep visitors a safe distance from the work area. Keep children away.
Page 5 of the Powermatic PM1900TX user manual — - - SAVE THESE INSTRUCTIONS - -
Page 5 · cliquer pour agrandir
Page 5
20. Make your workshop child proof with padlocks, master switches or by removing starter keys.
21. Give your work undivided attention. Looking around, carrying on a conversation and “horse-play” are careless acts that can result in serious injury.
22. To reduce the risk of electric shock, do not use outdoors or on wet surfaces.
23. Do not use the dust collector for anything except wood dust. Materials such as liquids, metal shavings, metal dust, screws, glass, plastic or rock can cause sparks and/or damage when coming into contact with any part of the dust collector.
24. Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.
25. Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.
26. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run dust collector over cord. Keep cord away from heated surfaces.
27. Do not use this dust collector with a damaged cord or plug.
28. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
29. Do not use without dust bag and/or filters in place.
30. Do not handle plug or machine with wet hands.
31. Do not put any objects into the openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.
32. Do not operate without hose connected to the inlet. Hazardous moving parts inside. Unplug before removing inlet or inlet guard.
33. Use recommended accessories; improper accessories may be hazardous.
34. Maintain tools with care. Follow instructions for lubricating and changing accessories.
35. Turn off the machine and disconnect from power before cleaning. Use a brush or compressed air to remove chips or debris — do not use your hands.
36. Do not leave the machine when it is plugged in. Unplug from outlet when not in use and before servicing.
37. Do not stand on the machine. Serious injury could occur if the machine tips over.

Familiarize yourself with the following safety notices used in this manual:

This means that if precautions are not heeded, it may result in minor injury and/or possible machine damage.

This means that if precautions are not heeded, it may result in serious injury or possibly even death.

- - SAVE THESE INSTRUCTIONS - -

Page 6 of the Powermatic PM1900TX user manual — Specifications
Page 6 · cliquer pour agrandir
Page 6

Introduction

This manual is provided by Powermatic covering the safe operation and maintenance procedures for a Powermatic Model PM1900TX Dust Collector. This manual contains instructions on installation, safety precautions, general operating procedures, maintenance instructions and parts breakdown. This machine has been designed and constructed to provide years of trouble free operation if used in accordance with instructions set forth in this manual. If there are any questions or comments, please contact your local supplier or Powermatic; or visit our web site: www.powermatic.com

Specifications

Model PM1900TX Stock Numbers: PM1900TX (Base Machine A), includes 3HP, 1PH Motor, Remote Control and Mag. Starter 1792071 PM1900TX (Base Machine B), includes 3HP, 3PH Motor, 230V/460V, (Pre-wired 230V) 1792073 PM1900TX (Base Machine A) with Filter Bag System 1792071K PM1900TX (Base Machine A) with Canister Filter System 1792072K PM1900TX (Base Machine B) with Filter Bag System 1792073K PM1900TX (Base Machine B) with Canister Filter System 1792074K Filter Bag System only 1791075B Canister Filter System only 1791086 Blower Wheel Diameter 14" Sound Rating at 3 feet 86-92 db Inlet Port Diameter (in.) three at 4” or one at 8” Air Flow at 8” – Base Machine A and B (CFM) 1891 Velocity at 8” – Base Machine A and B (FPM) 5393.7 Static Pressure (inch of water) 12.15 Bags and Canister Diameter (in.) 20 Filter Bag Length (in.) 48 Filter Bag Efficiency 96% of 30 micron particles Canister Length (in.) 26 Canister Efficiency 86% of 1 micron particles; 98% of 2 micron particles Collector Bag Capacity (cu. ft.) 10 Remote Control Type (1PH unit only) infrared Overall Dimensions with Filter Bag System (LxWxH)(in.) 61 x 30 x 94 Overall Dimensions with Canister System (LxWxH)(in.) 61 x 30 x 72 Motor (TEFC) 3 HP, 1Ph 230V only or 3 HP, 3Ph, 230V/460V, Pre-wired 230V Approximate Weight (net/shipping): PM1900TX with Filter Bag System (lbs.) 211/215 PM1900TX with Canister System (lbs.) 268/272

The above specifications were current at the time this manual was published, but because of our policy of continuous improvement, Powermatic reserves the right to change specifications at any time and without prior notice, without incurring obligations.

Page 7 of the Powermatic PM1900TX user manual — Contents of Shipping Carton
Page 7 · cliquer pour agrandir
Page 7
Powermatic PM1900TX — Unpacking diagram (page 7)
Fig. 5 · Unpacking

Unpacking

Remove all contents from the shipping carton and check against the Contents of Shipping Carton below to verify that all items have been received.

Report any damage to your distributor.

Do not discard any shipping material until after the dust collector has been assembled and is running properly.

Powermatic PM1900TX — Unpacking diagram (page 7)
Fig. 6 · Unpacking

You will also require either the Filter Bag System or Canister Filter System. These items are packaged separately and are not listed here.

Contents of Shipping Carton

Refer to Figure 3 to identify items K–Z.

Figure 1Main Hardware Bag contents

K Base (1) L Base Extension (2) M Caster (4) N Motor/Impeller Assembly (1) O Inlet Guard (1) P Inlet Port w/ Cap (1) Q Lower Gasket (1) R Connector Tube (1) S Control Box (1) T Upper Gasket (2) U Left Housing (1) V Right Housing (1) W Support Bar (2) X Handle (2) Y Plate (2) Z Socket Head Cap Screw, M8x12 (4) -- Remote Control w/ batteries (single phase

* A through G comprise PM1900-BMHP Base Machine Hardware Package

Powermatic PM1900TX — Contents of Shipping Carton diagram (page 7)
Fig. 7 · Contents of Shipping Carton
Powermatic PM1900TX — Contents of Shipping Carton diagram (page 7)
Fig. 8 · Contents of Shipping Carton
Powermatic PM1900TX — Contents of Shipping Carton diagram (page 7)
Fig. 9 · Contents of Shipping Carton
Powermatic PM1900TX — Contents of Shipping Carton diagram (page 7)
Fig. 10 · Contents of Shipping Carton

machine only) (not shown) -- Owner's Manual (not shown) -- Warranty Card (not shown)

Powermatic PM1900TX — Contents of Shipping Carton diagram (page 7)
Fig. 11 · Contents of Shipping Carton

Main Hardware Bag contents (Figure 1): A – M8 x 20 Hex Cap Screws (34)* B – M6 x 12 Pan Head Flange Screws (8)* C – 3/16” x 1/2” Pan Head Flange Screw (1)* D – M8 Flat Washers (60)* E – M10 Flat Washers (6)* F – M8 Hex Nuts (30)* G – M8 Lock Washers (4)* H – 3/8" Hex Nuts (4) – on casters J – M10 Lock Washers (4) – on casters

Powermatic PM1900TX — Contents of Shipping Carton diagram (page 7)
Fig. 12 · Contents of Shipping Carton
Powermatic PM1900TX — Contents of Shipping Carton diagram (page 7)
Fig. 13 · Contents of Shipping Carton
Figure 2Cone Assembly and Hardware

CC through GG comprise DC1100-HP2

Cone Assembly Hardware Package

Cone Assembly and Hardware (Figure 2): AA – Support Bracket BB – Cone CC – M8 x 16 Hex Cap Screws (2) DD – M8 Flat Washers (2) EE – M8 Hex Nuts (2) FF – M 6 x 12 Hex Cap Screws (8) GG – M6 Hex Nuts (8)

Tools Required for Assembly – 13mm Wrenches or Sockets – 14mm Wrench #2 Cross Point Screw Driver 6mm hex (“Allen”) wrench

Page 8 of the Powermatic PM1900TX user manual — Connector Tube and Switch Box
Page 8 · cliquer pour agrandir
Page 8

Base Machine Assembly

3. Insert an M8x20 hex cap screw (A), through the M8 washer (D) and flanges of the connector tube (R) and impeller housing (N). 4. Place another washer (D) and a hex nut (F) on the protruding end of the screw (A) and hand- tighten only. 5. Mount the control box (S) to the two holes at the front of the connector tube flange (R). 6. Repeat steps 3 and 4 for the remaining screw locations, hand tightening only. 7. Tighten all hex nuts with a 13mm wrench. Collector Housings

The dust collector must not be connected to the power source during assembly. All instructions on this page refer to Figure 3.

Base and Base Extensions 1. Attach the base extensions (L) to the base (K) by inserting M8x20 hex head screws (A) through the mounting holes of the extension (L) and base (K). 2. Place M8 flat washers (D) and M8 lock washers (G) on the ends of the screws (A) and fasten with M8 hex nuts (F), using 13mm wrenches. Casters 1. The 3/8” hex nut (H) and M10 lock washer (J) are pre-assembled to each caster (M). For shipping purposes, the lock washer has been placed beneath the hex nut. Remove hex nut and lock washer from the caster shaft, re-install the hex nut, then install the lock washer above the hex nut, as shown. 2. Install the four casters (M) to the underside of the base (K) as follows: 3. Thread the caster shaft into the threaded hole on the underside of the base (K), turn until snug. Tighten the hex nut (H) against the base with a 14mm wrench. Motor and Impeller Assembly

Mount the right collector housing (V) as follows: 1. Place an upper gasket (T) between the collector housing (V) and connector tube (R). Line up the pegs on the gasket (T) with the holes in the housing (V). 2. Place the collector housing (V) on the connector tube (R). Make sure to properly orient the collector housing – the internal baffle must slope downwards toward the center. 3. Insert a screw (A) through the washer (D), connector tube flange (R), and collector-housing flange (V). 4. Place another washer (D) and a hex nut (F) on the protruding end of the screw (A) and hand- tighten. 5. Repeat steps 1 through 4 for the seven remaining screw locations. 6. Tighten all screws and hex nuts with a 13mm wrench. 7. Repeat steps 1 through 6 for the left collector housing (U). Support Bars 1. Align the bottom slots of a support bar (W) with the holes in the base (K). Insert two screws (A) with two flat washers (D) and hand tighten only. Note: If you are using the Canister Filter System, proceed with steps 2 through 5 below. If you are using the Filter Bag System, leave the support bar (W) as is, for further assembly later, and proceed to “Handles”. 2. Align the top holes of the support bar (W) with the holes at the rear of the collector housing (V) and insert two screws (A) and two flat washers (D). 3. Place a washer (D) and a hex nut (F) on the protruding end of each screw (A) inside the collector housing, and hand-tighten only. 4. Adjust the lower part of the support bar (W) as needed using its slots, until it is straight. Then tighten all four screws on the support bar (W).

1. Place the base with casters down on the ground. 2. Attach the motor and impeller assembly (N) to the base (K) using six M8x20 hex cap screws (A), and six M10 flat washers (E). Hand tighten only until all screws and washers are in place, then tighten all six screws with a 13mm wrench. 3. Attach the inlet guard (O) to impeller housing (N) using eight M6x12 pan head flange screws (B). 4. Press the inlet port (P) onto the inlet guard (O) until it snaps into place. Secure in place with 3/16” x 1/2” pan head flange screw (C).

To reduce the risk of injury from moving parts, always keep inlet port (P) covered with the caps provided, if they are not connected to a hose.

Connector Tube and Switch Box

1. Place the lower gasket (Q) on the impeller housing (N). Line up the rubber pegs on the gasket (face down) with the holes in the housing. 2. Place the connector tube (R) on the impeller housing (N), making sure that the holes of the mating flanges are aligned. Note: Refer to Figure 3 to make sure that the connector tube is facing the proper direction.
5. Repeat for the other support bar.
Page 9 of the Powermatic PM1900TX user manual — Handles
Page 9 · cliquer pour agrandir
Page 9

Handles

Cone Installation

1. Remove the plate (Y) from the handle (X) by loosening the two socket head cap screws (Z) with a 6mm hex wrench. 2. Install handle (X) to the holes in the collector housing (U) by inserting the socket head cap screws through the handle, the collector housing, and into the plate on the opposite side. Tighten the screws. Note: Make sure the plate (Y) is oriented properly, as shown in the Detail in Figure 3: The protrusions on the plate should face away from the handle. 3. Install the other three handles in like manner. (Two handles for each housing.)

Install the cone assembly as shown in Figure 3a.

1. Mount the cone support bracket (AA) to the housing with four M6x12 hex cap screws (FF) and tighten from beneath with four M6 hex nuts (GG). 2. Install the cone (BB) from beneath using the M8x16 hex cap screw (CC), M8 flat washer (DD) and M8 hex nut (EE). Filter System

If your PM1900TX Dust Collection system includes filter bags, proceed to Filter Bag System Assembly on page 10. If your PM1900TX Dust Collection system includes the canister kit, proceed to Canister System Assembly on page 11.

Powermatic PM1900TX — Handles diagram (page 9)
Fig. 14 · Handles
Powermatic PM1900TX — Handles diagram (page 9)
Fig. 15 · Handles
Powermatic PM1900TX — Handles diagram (page 9)
Fig. 16 · Handles
Powermatic PM1900TX — Handles diagram (page 9)
Fig. 17 · Handles
Powermatic PM1900TX — Handles diagram (page 9)
Fig. 18 · Handles
Powermatic PM1900TX — Handles diagram (page 9)
Fig. 19 · Handles
Powermatic PM1900TX — Handles diagram (page 9)
Fig. 20 · Handles
Powermatic PM1900TX — Handles diagram (page 9)
Fig. 21 · Handles
Powermatic PM1900TX — Handles diagram (page 9)
Fig. 22 · Handles
Powermatic PM1900TX — Handles diagram (page 9)
Fig. 23 · Handles
Powermatic PM1900TX — Handles diagram (page 9)
Fig. 24 · Handles
Powermatic PM1900TX — Handles diagram (page 9)
Fig. 25 · Handles
Figure 3Assembly and part identification
Page 10 of the Powermatic PM1900TX user manual — Filter Bag System Assembly
Page 10 · cliquer pour agrandir
Page 10
9. Thread the retainer strap (Figure 6) through the loops on the filter bag, and fasten it to the collector housing, as shown in Figure 7.

Filter Bag System Assembly

Powermatic PM1900TX — Filter Bag System Assembly diagram (page 10)
Fig. 26 · Filter Bag System Assembly
1. Insert a hanger bracket between support bar and collector housing (Figure 4).
2. Align holes and secure with two M8x20 hex cap screws and two M8 flat washers outside the housing, and two M8 flat washers and two M8 hex nuts inside the housing. Hand tighten only.
Powermatic PM1900TX — Filter Bag System Assembly diagram (page 10)
Fig. 27 · Filter Bag System Assembly
Powermatic PM1900TX — Filter Bag System Assembly diagram (page 10)
Fig. 28 · Filter Bag System Assembly
3. Make any needed adjustments to the support bar , then tighten the two upper and two lower screws on the support bar with 13mm wrenches.
4. Insert the ring (Figure 5) of the collector bag into the bottom of the housing at an angle. Pull down on the collector bag to make sure it “seats” on the inner lip of the housing.
5. Position the plastic window in front so that you can easily see when collector bag is full.
6. Connect the upper hanger to the hanger support bar (Figure 6).
Powermatic PM1900TX — Filter Bag System Assembly diagram (page 10)
Fig. 29 · Filter Bag System Assembly
7. Slide the loop of the filter bag over the hook on the upper hanger and mount the hanger assembly onto the hanger bracket (Figure 4). Rotate the hanger so that the hook at the top points toward the front of the machine.
Powermatic PM1900TX — Filter Bag System Assembly diagram (page 10)
Fig. 30 · Filter Bag System Assembly
8. Unroll the retainer straps (Figure 6). CAUTION: Retainer straps are coiled under tension. Maintain a firm grip on each one while unrolling it.

The retainer strap should be tight enough to provide a good seal.

Retainer strap · connection

Page 11 of the Powermatic PM1900TX user manual — Canister System Assembly
Page 11 · cliquer pour agrandir
Page 11
Powermatic PM1900TX — Canister System Assembly diagram (page 11)
Fig. 31 · Canister System Assembly

Canister System Assembly

1. Place the snap ring over the top of the plastic collector bag , and fold over the bag approximately three inches (Figure 8).
Powermatic PM1900TX — Canister System Assembly diagram (page 11)
Fig. 32 · Canister System Assembly
Powermatic PM1900TX — Canister System Assembly diagram (page 11)
Fig. 33 · Canister System Assembly
2. Insert the snap ring of the collector bag into the bottom of the housing at an angle (Figure 9).
3. Pull down on the snap ring to make sure it “seats” on the inner lip of the housing.
Powermatic PM1900TX — Canister System Assembly diagram (page 11)
Fig. 34 · Canister System Assembly
4. Remove the handle (Figure 10) from inside the canister filter . Mount the handle onto the canister filter with two M10 hex nuts (A), two M10 flat washers (B), and an M10 lock washer (C). Arrange these fasteners according to Figure 10. Tighten with a 17mm wrench.
5. Place the canister on top of the housing, and push down to ensure the canister is seated on the housing.
6. Insert and tighten the four knobs into the threaded holes on the canister (Figure 10).

(17mm wrench required)

Page 12 of the Powermatic PM1900TX user manual — Operating the Machine
Page 12 · cliquer pour agrandir
Page 12

Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the tool is properly grounded.

Electrical Connections

Electrical connections must be made by a qualified electrician in compliance with all relevant codes. This machine must be properly grounded to help prevent electrical shock and possible fatal injury.

Repair or replace a damaged or worn cord immediately.

Extension Cords

If an extension cord is needed, make sure the cord rating is suitable for the amperage listed on the machine’s motor plate. An undersize cord will cause a drop in line voltage resulting in loss of power and overheating.

The PM1900TX is equipped with either a single phase, 230 volt only motor; or a three phase, 230/460V motor (pre-wired 230V). Keep in mind that a circuit being used by other machines (tools, lights, heaters, etc.) at the same time will add to the electrical load. Thus, it is recommended that the single phase machine be connected to a dedicated 40 amp circuit, with a 40 amp circuit breaker or fuse. It is recommended that the three phase machine be connected to a dedicated 20 amp circuit with a 20 amp circuit breaker or fuse. Local codes take precedence over recommendations.

Use the chart in Figure 11 as a general guide in choosing the correct size cord. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

Recommended Gauges (AWG) of Extension Cords

Powermatic PM1900TX — Extension Cords diagram (page 12)
Fig. 35 · Extension Cords
AmpsExtension Cord Length * 25 feet50 feet75 feet100 feet150 feet200 feet < 5161616141212 5 to 81616141210NR 8 to 1214141210NRNR 12 to 1512121010NRNR 15 to 20101010NRNRNR 21 to 3010NRNRNRNRNR

The three phase dust collector can be re-wired for 460V operation as follows:

To convert from 230 to 460 volt operation:

1. Disconnect from power source; unplug!
2. Connect the motor leads as shown in the diagram inside the motor junction box; this diagram is also shown on page 20 of this manual.
3. Replace the plug on the power cord with an appropriate UL/CSA listed 460V plug.

*based on limiting the line voltage drop to 5V at 150% of the rated amperes. NR: Not Recommended.

4. When finished wiring, re-install junction box cover.

Grounding Instructions This machine must be grounded. In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.

Operating the Machine

3 Phase models: Connect the dust collector to the power source, and use the industrial-style push-button switch to operate the machine.

Improper connection of the equipment- grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes, is the equipment- grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal.

1 Phase models: If power is flowing, a green indicator will light on the face of the control panel. To operate the machine, use the buttons on the control panel, or use the provided remote control. To start the dust collector, press the ON button. If the remote control is used, aim it at the control panel. The machine will remain running until the OFF button is pressed. The digital readout will always display 00 while running.

The hose or ductwork you use to connect the tool to the dust collector must also be grounded.

The remote control operates on two AAA batteries. These will need replacing periodically.

Make sure the voltage of your power supply matches the specifications on the motor plate of the dust collector.

Page 13 of the Powermatic PM1900TX user manual — Maintenance
Page 13 · cliquer pour agrandir
Page 13

Cleaning the Filter Bags

Wearing a particle mask or respirator for protection against fine dust particles during cleaning is highly recommended.

Powermatic PM1900TX — Cleaning the Filter Bags diagram (page 13)
Fig. 36 · Cleaning the Filter Bags

During first use and after cleaning, the filter bags may allow some dust to escape. This is normal and will stop after a short period of time.

Clean both the filter and collector bags frequently to keep the collector's performance at its optimum. To clean:

1. Disconnect machine from the power source.
2. Unhook the filter bag from the hanger. Shake the bag so that the majority of the dust falls into the collector bag.

Setting the Timer (1-Phase Models)

While the machine is running, press the TIME button to activate the timer. Each time the button is pressed and released, the run time is incremented on the digital display by one minute and can be set up to 99 minutes.

3. Loosen the retaining strap, and remove the filter bag from the housing.
4. Turn the bag inside-out and clean.
5. Turn the bag outside-in and re-attach to the housing using the retainer strap to secure.

If the TIME button is pressed and held, the time will scroll up to 99 minutes, then start again at 00. Release the button when the desired set time is reached. The dust collector will run for the amount of time displayed on the digital display. If you scroll past 99 and release the button at 10, for example, the machine will run for ten minutes, not 110 minutes.

Removing the Collector Bags

1. Disconnect machine from the power source.
2. Remove the collector bag by pushing the ring of the collector bag upwards and pulling the bag out at an angle.

If the OFF button is pressed while machine is running with the timer engaged, the machine turns off and the timer is disengaged; i.e., when the machine is restarted, the timer must be reset.

3. Empty the contents into an appropriate container.
4. Turn the bag inside-out and clean.
5. Turn the bag outside-in and insert into the housing.

Connecting the Dust Collector to a Machine

Cleaning the Canister Filters

Clean the canister filters frequently to keep the collector's performance at its optimum. To clean the filter, turn the handle a couple of rotations so the dust falls into the clear plastic bag. Properly discard the plastic bag.

Use the proper type hose to connect the dust collector to the machine being operated. Dryer vent hose is not acceptable for this purpose. Contact your nearest Powermatic distributor for a full line of Dust Collector hoses and accessories. You can customize your installation and obtain maximum performance with dust hoods, hoses, clamps, fittings, and blast gates.

Motor

Make frequent inspections of the motor fan and blow out (with low pressure air hose) or vacuum any accumulation of foreign material in order to maintain normal motor ventilation.

Maintenance

Never perform maintenance on this machine before turning it OFF and removing plug from power source. Failure to comply may cause serious injury!

Page 14 of the Powermatic PM1900TX user manual — Breakdown for PM1900TX Dust Collector (Base Machine)
Page 14 · cliquer pour agrandir
Page 14

Replacement Parts

Replacement Parts are listed on the following pages. To order parts or reach our service department, call 1-800-274- 6848, Monday through Friday (see our website for business hours, www.powermatic.com). Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately.

Breakdown for PM1900TX Dust Collector (Base Machine)

Powermatic PM1900TX — Breakdown for PM1900TX Dust Collector (Base Machine) diagram (page 14)
Fig. 37 · Breakdown for PM1900TX Dust Collector (Base Machine)
Page 17 of the Powermatic PM1900TX user manual — Parts List and Breakdown for PM1900TX Filter Bag System
Page 17 · cliquer pour agrandir
Page 17

Parts List and Breakdown for PM1900TX Filter Bag System

Index No. Part No. Description Size Qty

1791075B Collection and Filter Bag System (includes #1 thru 6) 1 1 1791075F Filter Bag 30 micron 2 2 430005 Retainer Strap 2 3 708699A Collection Bag 2 4 430039 Upper Hanger 2 5 430037 Support Bar 2 6 523011 Hanger Bracket 2

Powermatic PM1900TX — Parts List and Breakdown for PM1900TX Filter Bag System diagram (page 17)
Fig. 38 · Parts List and Breakdown for PM1900TX Filter Bag Sys…
Powermatic PM1900TX — Parts List and Breakdown for PM1900TX Filter Bag System diagram (page 17)
Fig. 39 · Parts List and Breakdown for PM1900TX Filter Bag Sys…
Powermatic PM1900TX — Parts List and Breakdown for PM1900TX Filter Bag System diagram (page 17)
Fig. 40 · Parts List and Breakdown for PM1900TX Filter Bag Sys…
Page 18 of the Powermatic PM1900TX user manual — Breakdown for PM1900TX Canister Filter System
Page 18 · cliquer pour agrandir
Page 18

Breakdown for PM1900TX Canister Filter System

Powermatic PM1900TX — Breakdown for PM1900TX Canister Filter System diagram (page 18)
Fig. 41 · Breakdown for PM1900TX Canister Filter System
Powermatic PM1900TX — Breakdown for PM1900TX Canister Filter System diagram (page 18)
Fig. 42 · Breakdown for PM1900TX Canister Filter System
Powermatic PM1900TX — Breakdown for PM1900TX Canister Filter System diagram (page 18)
Fig. 43 · Breakdown for PM1900TX Canister Filter System
Page 20 of the Powermatic PM1900TX user manual — Electrical Connections
Page 20 · cliquer pour agrandir
Page 20

Electrical Connections

Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

Powermatic PM1900TX — Electrical Connections diagram (page 20)
Fig. 44 · Electrical Connections
Powermatic PM1900TX — Electrical Connections diagram (page 20)
Fig. 45 · Electrical Connections
Powermatic PM1900TX — Electrical Connections diagram (page 20)
Fig. 46 · Electrical Connections
Page 21 of the Powermatic PM1900TX user manual — Manual de Instrucciones y Partes del Colector de Polvo PM1900TX
Page 21 · cliquer pour agrandir
Page 21

Manual de Instrucciones y Partes del Colector de Polvo PM1900TX

PM1900TX con Juego de Bolsa Filtro (1792071K) PM1900TX con Juego de Canastas (1792072K)

Powermatic 427 New Sanford Road LaVergne, TN 37086 Parte Nro. M-1792071 Teléf.: 800-274-6848 Revisión A4 02/2014 www.powermatic.com Copyright © 2014 Powermatic

Ahora con

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Powermatic PM1900TX

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Powermatic PM1900TX

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Powermatic PM1900TX manuel PDF

60 pages·3 MB·Collecteur de poussière·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…