EConnect™ Wireless Thermostat Kit TA7210 With Equipment Interface Module
ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power before beginning installation.
Must be installed by a certified electrician. Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.

or call Honeywell Customer Care toll-free at 1-800-831-2823.

The equipment interface module (EIM) allows you to control a baseboard heater, a convector or a fan-forced heater in a 120-volt, 208-volt or 240-volt application from a EConnect™ wireless thermostat.

Installation procedure Install the equipment interface module (EIM) Pages 3 - 6 Install batteries in wireless devices Page 7 Link all devices to wireless network Pages 7 - 10 Exit wireless setup Page 11 Customize thermostat (installer setup) Pages 11 - 18 Mount thermostat and outdoor sensor Pages 19 - 20
For error codes, see page 20. To verify the signal strength, see page 21. To replace a wireless device, see pages 21-22. For specifications and replacement parts, see page 23.

The equipment interface module (EIM) consists of a relay and an antenna. They can be installed either in the wiring compartment of the baseboard heater or in a 4-11/16” square junction box.
Install EIMs at a minimum distance of 2 feet (0.6 m) of each other. This minimum distance still applies even if the EIMs are on opposite sides of a wall.

The product has been tested for compatibility with the heaters listed above. If your heater is not on the list, install the EIM on a 4-11/16” square junction box or replace it with one listed.

The junction box can be installed anywhere in the house; for example, near the main electrical panel.
Relay Antenna

ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect AC power before beginning installation. Wiring must comply with local electrical codes. Use special CO/ALR solderless connectors if supply wires are made of aluminum.
Disconnect the heater wires from the supply wires. If the heater has a built-in thermostat, remove it.

ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect AC power before beginning installation. Wiring must comply with local electrical codes. Use special CO/ALR solderless connectors if supply wires are made of aluminum.


The maximum number of heaters per EIM is limited to a maximum load of 12.5 A

The maximum number of EIMs is 8 per thermostat.

Outdoor air sensor
(optional)
(optional)



Install 2 AA alkaline batteries Install 3 AA alkaline batteries Install 2 AA lithium batteries
Start wireless setup Press the EIM Connect button to place it in wireless setup. When the amber light changes to a green flashing light, you can begin to link devices to the wireless network (see pages 7-10).
If the amber light changes to a red light instead, there is another EIM currently in wireless setup. Press the Connect button on the other EIM to exit its wireless setup.

If the green flashing light disappears (after a delay of 15 minutes) before you have time to link all your devices, press the Connect button again.
Connect button · Connect LED *


Link thermostat and EIM to wireless network Perform the following steps on the thermostat:
If an error code (E followed by a number) appears on the screen, see its explanation on page 20.

Perform steps 1 to 6 for each additional EIM. You can link a maximum of 8 EIMs to the wireless network.

Skip steps 3 and 4 if the thermostat is displaying the Connexion menu (as shown in step 5).


If you have more than one wireless thermostat, make sure to activate the wireless setup from an EIM linked to the thermostat. For example, to display the outdoor temperature on thermostat Y, you must activate the wireless setup from either EIM B or C, not A.
If you have more than one wireless thermostat, repeat steps 1 and 3 for each thermostat.



If you have more than one wireless thermostat, make sure to activate the wireless setup from an EIM linked to the thermostat. For example, to link the remote control to thermostat Y, you must activate the wireless setup from either EIM B or C, not A.
Press to link to another network
Press to save and exit
Press and release

If you do not press the Connect button, the EIM will automatically exit wireless setup after 15 minutes of inactivity.

If you press Sortir (exit) after you have changed a setting, the new setting will not be saved. Make sure you press Ok to save the new setting before you press Sortir (exit).


Temperature unit / Time format Follow this procedure to select the temperature unit (°C or °F) and time format (12h or 24h).

The time format selection is available only if the thermostat is in programmable mode.


Minimum and maximum setpoints Follow this procedure to set the minimum and maximum setpoint temperature.

Programmable mode The thermostat is factory-set as a 7-day programmable thermostat. To set it as a non-programmable thermostat, proceed as follows:
Copy Use this function to copy the configuration settings, the schedule settings or both to other EConnect™ wireless thermostats in your house. This function is available only if the thermostat is connected either to a remote control or outdoor sensor. The settings are copied to other thermostats connected to the remote control or outdoor sensor.

Keypad lock By default, the keypad lock is disabled.

If you leave at Non (no), the homeowner will have full access to all thermostat functions.
If you select Part (Partial), the homeowner can change the room temperature only.
If you select Oui (yes), the buttons will not appear on the screen. To unlock, go to Installer Setup (see page 11).

Zone name The zone name is used to identify the thermostat on the wireless remote control. By default, the zone name is Thermostat (zone name 52). If you have a wireless remote control and more than one wireless thermostat, change the zone name of the thermostat to identify it from the other thermostats. For example, if the thermostat is in the living room, set the zone to 31.


1 Basement 16 Exercise Room 30 Library 44 Porch
2 Bathroom 17 Family Room 31 Living Room 45 Rec Room
3 Bathroom 1 18 Fireplace 32 Lower Level 46 Sewing Room
4 Bathroom 2 19 Foyer 33 Master Bath 47 Spa
5 Bathroom 3 20 Game Room 34 Master Bed 48 Storage Room
6 Bedroom 21 Garage 35 Media Room 49 Studio
7 Bedroom 1 22 Great Room 36 Music Room 50 Sun Room
8 Bedroom 2 23 Guest Room 37 Nursery 51 Theater
9 Bedroom 3 24 Gym 38 Office 52 Thermostat
10 Bedroom 4 25 Kid's Room 39 Office 1 53 Upper Level
11 Boat House 26 Kitchen 40 Office 2 54 Utility Room
12 Bonus Room 27 Kitchen 1 41 Pantry 55 Walk In Closet
13 Computer Room 28 Kitchen 2 42 Play Room 56 Wine Cellar
14 Den 29 Laundry Room 43 Pool Room 57 Workshop
Adaptive Intelligent Recovery (horaire anticipé) Available only if you use the thermostat in programmable mode. When Adaptive Intelligent Recovery is on, the thermostat “learns” how long your heater takes to reach the set temperature. The thermostat will then determine when to activate heating so the desired temperature is attained at the desired time. The thermostat re- assesses the heating start time daily based on the previous day’s performance. When Adaptive Intelligent Recovery is off, heating starts at the set time. To turn off Adaptive Intelligent Recovery, proceed as follows:


Anti-freeze When this function is on, the EIM will maintain the room temperature at 13°C (55°F) if it loses communication with the thermostat or if the thermostat sensor is defective.

Leave the protection on unless the EIM is installed in a junction box in a separate room from the heater.
To turn off the Anti-freeze protection, proceed as follows:
menu, press as needed to select Hors-Gel (anti-freeze) and press Ok.
System test 1) From the Home screen, press until the setpoint temperature is above the room ambient temperature by at least 2°. Press Temporaire (temporary). 2) Wait for Chauffe (heat) to display on the thermostat. 3) Verify if the heater becomes hot. 4) Press Annuler (cancel) to return the thermostat to its previous mode.

Two mounting plates are provided for mounting the thermostat on the wall or on a junction box. Use Method A for a slimmer thermostat look. Choose Method B if you prefer not to make an opening in the wall. Method C must be used for installation on a junction box.

Mark the four corners and join them to create a rectangular outline.
Cut along the outline to create an opening in the wall.
Secure the mounting plate to the wall using provided wall anchors and screws.
Mounting on a junction box (Method C)
Installing faceplate

Secure the mounting plate to the wall using provided wall anchors and screws.
Complete the thermostat installation by pressing the faceplate against the mounting plate.
Secure the mounting plate to a junction box using provided mechanical screws.

Mount the sensor vertically on an exterior wall, at least 6 inches below any overhang. Choose a location protected from direct sunlight. Place sensor securely in bracket, facing away from wall.
LO The indoor temperature is below 0°C (32°F).
HI The indoor temperature is above 60°C (140°F).
- - The temperature reading is currently unavailable or the sensor is defective.
E128 The wireless network setup must be redone.
E129 Attempting to connect incompatible wireless devices.
E130 Invalid address. Call customer assistance.
E134 Low signal strength. Move wireless device to a different location and try again.
E137 Maximum number of devices is exceeded.
E138 Make sure Connected light on EIM is flashing and you are 2+ feet away from EIM.
E152 Incorrect order. Make sure to link EIM to proper thermostat.


If you have more than one EIM linked to the thermostat, the displayed value is between the thermostat and the first-linked EIM. The signal strength ranges from 0 (no signal) to 10 (strongest).
Thermostat To replace the thermostat, install batteries in the new thermostat (see page 7) and link it to the wireless network (see page 8). To customize the thermostat, see pages 11-18.
If more than one EIM were linked to the old thermostat, you can link the new thermostat from any one of these EIMs.

Remote control or outdoor sensor To replace the remote control or the outdoor sensor, install batteries in the new device (see page 7) and link it to the wireless network (see page 10).
If more than one EIM are linked to the same thermostat, you can link the remote control or the outdoor sensor from any one of these EIMs. If you have more than one wireless thermostat, link the remote control or the outdoor sensor from one EIM of each of the wireless thermostats.
If you have a remote control: 1) Press and hold, for about 3 seconds, the blank space (or arrow if present) in the lower right corner of the screen until the display changes. 2) Press REMOVE, then YES.
If you have only one EIM linked to the thermostat: Remove the defective EIM, install a new one (see pages 3 - 6) and proceed as follows:
1) Check if the thermostat displays 0 Relais connecté(s) (0 relay connected) as shown on the right. If so, go straight to step 5. 2) From the home screen, press and hold the right center button for 5 secs. 3) Press to select Connexion (link) and press Ok. 4) Press to select Enlever (remove) and press Ok. The thermostat will display 0 Relais connecté(s) (0 relay connected). 5) Follow the procedures on pages 7-11 to set up a new network with the new EIM.
If you have more than one EIM linked to the thermostat: Follow the procedure below to identify the defective EIM(s) and to re-establish all links:
1) Remove the antenna cover from each EIM in the network by squeezing the cover (as shown by red arrows) and pulling it out. 2) Press, for 10 seconds, the Connect button on every EIM that has a green light. Repeat this step until none of the EIM shows a green light. 3) Check if the thermostat displays 0 Relais connecté(s) (0 relay connected) as shown on the right. If so, go straight to step 7. 4) From the home screen, press and hold the right center button for 5 secs. 5) Press to select Connexion (link) and press Ok. 6) Press to select Enlever (remove) and press Ok. The thermostat will display 0 Relais connecté(s) (0 relay connected). 7) Follow the procedures on pages 7-11 to create a new network. You will know that an EIM is defective if its light turns red or the thermostat displays an error code when you try to link the EIM to the network. Replace it before continuing to link other EIMs.
Press here

Temperature setpoint range: 5°C - 30°C (41°F - 86°F) Temperature setpoint resolution: 0.5°C (1°F) Temperature display range: 0°C - 40°C (32°F - 104°F) Temperature display resolution: 0.5°C (1°F) Heating cycle rate: 15 minutes Programming: 5-2 days, 7 days, 1 day or Non-Programmable
Thermostat: 0°C - 50°C (32°F - 122°F) Remote control: 0°C - 48.9°C (32°F - 120°F) EIM (relay): -20°C - 60°C (-4°F - 140°F) EIM (antenna): -20°C - 60°C (-4°F - 140°F) Outdoor air sensor: -40°C - 60°C (-40°F - 140°F)
Thermostat: 5% - 90% (non-condensing) Remote control: 5% - 90% (non-condensing) EIM (relay): 5% - 95% (non-condensing) EIM (antenna): 5% - 95% (non-condensing) Outdoor air sensor: 0% - 100% (condensing)
Thermostat: 130 x 82 x 29 mm (5.13 x 3.22 x 1.14 inches) EIM (relay): 73 x 63 x 29 mm (3.03 x 2.49 x 1.28 inches) EIM (antenna): 71 x 62 x 33 mm (2.89 x 2.63 x 1.16 inches) Outdoor air sensor: 127 x 89 x 43 mm (5.00 x 3.50 x 1.68 inches)
Supply: 100-240 VAC, 50/60 Hz Minimum load: 0.4 A (resistive only) Maximum load: 12.5 A (resistive only)
Item Part Number Equipment Interface Module (EIM) ATM100-SPK Remote control REM5000R1001 Outdoor air sensor C7089R1013 Antenna cover (white) 50055751-002 Antenna cover (almond) 50055751-004

FCC Compliance Statement (Part 15.19) (USA only) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation.
FCC Warning (Part 15.21) (USA only) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC Interference Statement (Part 15.105 (b)) (USA only) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
EIM, thermostats and outdoor sensor To comply with FCC and Industry Canada RF exposure limits for general population/ uncontrolled exposure, the antenna(s) used for these transmitters must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
Remote control This portable transmitter with its antenna complies with FCC and Industry Canada RF exposure limits for general population/uncontrolled exposure. This device must not be co-located or operating in conjunction with any other antenna or transmitter.
Section 7.1.3 of RSS-GEN Operation is subject to the following two conditions: 1) This device may not cause interference, and 2) This device must accept any interference, including interference that may cause undesired operation of the device.
Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate using an antenna of type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is not more than that necessary for successful communication.




or call Honeywell Customer Care toll-free at 1-800-831-2823.
Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 http://customer.honeywell.com
Honeywell Limited 705 Montrichard Saint-Jean-sur-Richelieu, Québec, J2X 5K8 www.aubetech.com
69-2472EF-01 06-2011 © 2011 Honeywell International Inc. ® U.S. Registered Trademark. All rights reserved. Printed in USA