System Installation Guide

EConnect™ Wireless Thermostat Kit TA7210 With Equipment Interface Module

  • Installation guide for:
  • Wireless equipment interface module
  • EConnect™ wireless thermostat
  • Wireless remote control
  • Wireless outdoor air sensor

IMPORTANT INSTRUCTIONS

ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power before beginning installation.

Must be installed by a certified electrician. Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.

Aube Technologies TA7210 — IMPORTANT INSTRUCTIONS diagram (page 1)
Fig. 2

or call Honeywell Customer Care toll-free at 1-800-831-2823.

Page 2 of the Aube Technologies TA7210 user manual — SAVE THESE INSTRUCTIONS
Page 2 · cliquer pour agrandir
Page 2

System installation at a glance

The equipment interface module (EIM) allows you to control a baseboard heater, a convector or a fan-forced heater in a 120-volt, 208-volt or 240-volt application from a EConnect™ wireless thermostat.

Aube Technologies TA7210 — System installation at a glance diagram (page 2)
Fig. 3 · System installation at a glance

Installation procedure Install the equipment interface module (EIM) Pages 3 - 6 Install batteries in wireless devices Page 7 Link all devices to wireless network Pages 7 - 10 Exit wireless setup Page 11 Customize thermostat (installer setup) Pages 11 - 18 Mount thermostat and outdoor sensor Pages 19 - 20

For error codes, see page 20. To verify the signal strength, see page 21. To replace a wireless device, see pages 21-22. For specifications and replacement parts, see page 23.

SAVE THESE INSTRUCTIONS

Page 3 of the Aube Technologies TA7210 user manual — Determine the location
Page 3 · cliquer pour agrandir
Page 3

Install the Equipment Interface Module (EIM)

Determine the location

The equipment interface module (EIM) consists of a relay and an antenna. They can be installed either in the wiring compartment of the baseboard heater or in a 4-11/16” square junction box.

Install EIMs at a minimum distance of 2 feet (0.6 m) of each other. This minimum distance still applies even if the EIMs are on opposite sides of a wall.

  • Installing the EIM in a baseboard heater You can install the EIM in the wiring compartment of the baseboard heater if you have any of the heaters listed in the following table:
Aube Technologies TA7210 — Determine the location diagram (page 3)
Fig. 4 · Determine the location

The product has been tested for compatibility with the heaters listed above. If your heater is not on the list, install the EIM on a 4-11/16” square junction box or replace it with one listed.

  • Installing the EIM in a 4-11/16” square junction box You can use a 4-11/16” square junction box in either of the following conditions:
  • You have a convector or fan-forced heater.
  • You cannot install or do not wish to install the EIM in the wiring compartment of the baseboard heater.
Aube Technologies TA7210 — Determine the location diagram (page 3)
Fig. 5 · Determine the location

The junction box can be installed anywhere in the house; for example, near the main electrical panel.

Relay Antenna

Page 4 of the Aube Technologies TA7210 user manual — Installation in a baseboard heater
Page 4 · cliquer pour agrandir
Page 4

Installation in a baseboard heater

ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect AC power before beginning installation. Wiring must comply with local electrical codes. Use special CO/ALR solderless connectors if supply wires are made of aluminum.

Disconnect the heater wires from the supply wires. If the heater has a built-in thermostat, remove it.

1) Remove the knockout on the side of the heater.2) Remove the locknut from the antenna and peel off the adhesive backing. Feed the antenna cable through the knockout and install the antenna vertically as shown. Put the locknut and tighten. Relay wires must be at the top 3) Clean the back panel inside the wiring compartment where the relay will be installed. Peel the adhesive backing off the relay and stick the relay on the back panel.N L : For 120V application L2 L1 : For 240V application Blue Black Red 4) Connect the heater wires and the supply wires to the relay. See page 6 if you are connecting more than one heater. 5) Insert the antenna plug into the relay receptacle until you hear a click.Install plug if applicable. 6) Put the heater cover back. (If a built-in thermostat was removed, install one of the supplied plugs to cover the hole on the existing cover.) Apply power to the heater. Do not install the antenna cover yet. ELECTRICAL HAZARD Can cause electrical shock. Install heater cover plate before applying power.
Page 5 of the Aube Technologies TA7210 user manual — Installation in a 4-11/16'' square junction box
Page 5 · cliquer pour agrandir
Page 5

Installation in a 4-11/16'' square junction box

ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect AC power before beginning installation. Wiring must comply with local electrical codes. Use special CO/ALR solderless connectors if supply wires are made of aluminum.

1) Mount the junction box on the wall. Punch out knockout(s), install strain relief bushing(s) and feed the supply wires and the heater wires. Punch out another knockout to install the antenna (step 2).2) Remove the locknut from the antenna and peel off the adhesive backing. Feed the antenna cable through the knockout opening and mount the antenna. Put the locknut and tighten. Relay wires must be at the top 3) Clean the interior side of the junction box where the relay will be installed. Peel off the adhesive backing of the relay module and stick the relay inside the junction box.N L : For 120V application L2 L1 : For 240V application Blue Black Red To heater 4) Connect the supply wires and heater wires to the relay. See page 6 if you are connecting more than one heater. 5) Insert the antenna plug in the relay receptacle until you hear a click.6) Install a cover plate on the junction box and apply power to the heater. Do not put the antenna cover back yet. ELECTRICAL HAZARD Can cause electrical shock. Install junction box cover plate before applying power.
Page 6 of the Aube Technologies TA7210 user manual — Connecting multiple EIMs on the same circuit
Page 6 · cliquer pour agrandir
Page 6

Connecting multiple heaters to the same EIM

Aube Technologies TA7210 — Connecting multiple heaters to the same EIM diagram (page 6)
Fig. 6 · Connecting multiple heaters to the same EIM

The maximum number of heaters per EIM is limited to a maximum load of 12.5 A

Connecting multiple EIMs on the same circuit

Aube Technologies TA7210 — Connecting multiple EIMs on the same circuit diagram (page 6)
Fig. 7 · Connecting multiple EIMs on the same circuit
L2 L1For 240V application N L : For 120V application

The maximum number of EIMs is 8 per thermostat.

Page 7 of the Aube Technologies TA7210 user manual — Link all devices to wireless network
Page 7 · cliquer pour agrandir
Page 7

Install batteries in wireless devices

Thermostat Remote control

Outdoor air sensor

(optional)

(optional)

Aube Technologies TA7210 — Thermostat Remote control diagram (page 7)
Fig. 8 · Thermostat Remote control
Aube Technologies TA7210 — Thermostat Remote control diagram (page 7)
Fig. 9 · Thermostat Remote control
Aube Technologies TA7210 — Thermostat Remote control diagram (page 7)
Fig. 10 · Thermostat Remote control

Install 2 AA alkaline batteries Install 3 AA alkaline batteries Install 2 AA lithium batteries

Link all devices to wireless network

Start wireless setup Press the EIM Connect button to place it in wireless setup. When the amber light changes to a green flashing light, you can begin to link devices to the wireless network (see pages 7-10).

If the amber light changes to a red light instead, there is another EIM currently in wireless setup. Press the Connect button on the other EIM to exit its wireless setup.

Aube Technologies TA7210 — Link all devices to wireless network diagram (page 7)
Fig. 11 · Link all devices to wireless network

If the green flashing light disappears (after a delay of 15 minutes) before you have time to link all your devices, press the Connect button again.

* Flashing greenReady for connection Steady green: Connection established Steady red: Connection failure

Connect button · Connect LED *

Page 8 of the Aube Technologies TA7210 user manual — Install batteries in wireless devices
Page 8 · cliquer pour agrandir
Page 8
Aube Technologies TA7210 — Install batteries in wireless devices diagram (page 8)
Fig. 12 · Install batteries in wireless devices

Link thermostat and EIM to wireless network Perform the following steps on the thermostat:

1. The Connexion (link) menu appears when you connect the thermostat to wireless network for the first time. Press Ok to select Zone .
2. Press or to change the zone name (optional; see page 17) and press Ok .
4. SUCC (success) confirms the connection is successful. Press Sortir (exit) once to link another EIM (see page 9) or 3 times to return to home screen.

If an error code (E followed by a number) appears on the screen, see its explanation on page 20.

Page 9 of the Aube Technologies TA7210 user manual — Link additional EIM to wireless network (optional)
Page 9 · cliquer pour agrandir
Page 9

Link additional EIM to wireless network (optional)

Perform steps 1 to 6 for each additional EIM. You can link a maximum of 8 EIMs to the wireless network.

1. If the green light on the previously-linked EIM is flashing, press its Connect button. The green light will become steady. 2) Press the Connect button on the next EIM you wish to link and wait for its green flashing light.
Aube Technologies TA7210 — Link additional EIM to wireless network (optional) diagram (page 9)
Fig. 13 · Link additional EIM to wireless network (optional)

Skip steps 3 and 4 if the thermostat is displaying the Connexion menu (as shown in step 5).

3. Press and hold the right center button for 5 secs.
4. From the installer’s setup menu, press to select Connexion (link) and press Ok .
5. Press to select Connecter autre (connect more) and press Ok .
6. SUCC (success) confirms the connection is successful. Press Sortir (exit) once and go back to step 1 to link another EIM or press Sortir (exit) 3 times to return to home screen.
Page 10 of the Aube Technologies TA7210 user manual — Link remote control to wireless network (optional)
Page 10 · cliquer pour agrandir
Page 10
Aube Technologies TA7210 — Link outdoor sensor to wireless network (optional) diagram (page 10)
Fig. 14 · Link outdoor sensor to wireless network (optional)

Link outdoor sensor to wireless network (optional)

1. Make sure the Connect light on the EIM is flashing (see page 7).

If you have more than one wireless thermostat, make sure to activate the wireless setup from an EIM linked to the thermostat. For example, to display the outdoor temperature on thermostat Y, you must activate the wireless setup from either EIM B or C, not A.

2. Press the Connect button on the back of the sensor. 3) After 15 seconds, check if the thermostat is displaying a value for the outdoor temperature reading.

If you have more than one wireless thermostat, repeat steps 1 and 3 for each thermostat.

Aube Technologies TA7210 — Link outdoor sensor to wireless network (optional) diagram (page 10)
Fig. 15 · Link outdoor sensor to wireless network (optional)

Link remote control to wireless network (optional)

Aube Technologies TA7210 — Link remote control to wireless network (optional) diagram (page 10)
Fig. 16 · Link remote control to wireless network (optional)
Aube Technologies TA7210 — Link remote control to wireless network (optional) diagram (page 10)
Fig. 17 · Link remote control to wireless network (optional)
1. Make sure the Connect light on the EIM is flashing (see page 7).

If you have more than one wireless thermostat, make sure to activate the wireless setup from an EIM linked to the thermostat. For example, to link the remote control to thermostat Y, you must activate the wireless setup from either EIM B or C, not A.

2. Press CONNECT at the remote control. 3) When the remote control displays Connected (after a short delay), press DONE . 4) Press NO at the next screen to save and exit. (Or press YES and repeat steps 1-4 to link to another network).

Press to link to another network

Press to save and exit

Press and release

Page 11 of the Aube Technologies TA7210 user manual — Exit wireless setup
Page 11 · cliquer pour agrandir
Page 11

Exit wireless setup

1. Press the EIM Connect button. Its green flashing light will change to a steady green light.

If you do not press the Connect button, the EIM will automatically exit wireless setup after 15 minutes of inactivity.

2. Put the cover back on the antenna module.
Aube Technologies TA7210 — Exit wireless setup diagram (page 11)
Fig. 18 · Exit wireless setup
  • To access the installer setup menu from the home screen, press and hold the right center button for 5 secs.
  • Press or to navigate the menus and setup functions.
  • Press Ok to select the flashing menu or setup function.
  • Press or to modify the displayed setting.
  • Press Ok to save the displayed setting. The setting will flash to confirm that it has been saved.
  • Press Sortir (exit) once to return to the previous menu or as many times as necessary to return to the home screen.

If you press Sortir (exit) after you have changed a setting, the new setting will not be saved. Make sure you press Ok to save the new setting before you press Sortir (exit).

Page 12 of the Aube Technologies TA7210 user manual — Installer setup table
Page 12 · cliquer pour agrandir
Page 12

Installer setup table

Aube Technologies TA7210 — Installer setup table diagram (page 12)
Fig. 19 · Installer setup table
Setup functionOptionsDefault settingTo modify, see Temperature unit°C / °F°CPage 12 Time format12h / 24h24hPage 12 Minimum setpoint5°C to 30°C (41°F to 86°F)5°C (41°F)Page 13 Maximum setpoint5°C to 30°C (41°F to 86°F)30°C (86°F)Page 13 Programmable modeOn / OffOnPage 14 Keypad lockNone / Partial / AllNonePages 15 Zone name1, ..., 5752Pages 16-17 Adaptive Intelligent RecoveryOn / OffOnPage 18 Anti-freezeOn / OffOnPage 18

Temperature unit / Time format Follow this procedure to select the temperature unit (°C or °F) and time format (12h or 24h).

Aube Technologies TA7210 — Installer setup table diagram (page 12)
Fig. 20 · Installer setup table

The time format selection is available only if the thermostat is in programmable mode.

1. From the installer’s setup menu, press Ok to select the Format menu.
2. Press or to change the temperature unit. Press Ok .
3. Press or to change the time format. Press Ok .
Page 13 of the Aube Technologies TA7210 user manual — Installer setup table
Page 13 · cliquer pour agrandir
Page 13
Aube Technologies TA7210 — Installer setup table diagram (page 13)
Fig. 21 · Installer setup table

Minimum and maximum setpoints Follow this procedure to set the minimum and maximum setpoint temperature.

1. From the installer’s setup menu, press to select Consignes (setpoints) and press Ok .
3. Press or to change the minimum setpoint. Press Ok .
5. Press or to change the maximum setpoint. Press Ok .
6. Press Sortir (exit) once to return to installer’s setup menu or twice to return to home screen.
Page 14 of the Aube Technologies TA7210 user manual — Installer setup table
Page 14 · cliquer pour agrandir
Page 14

Programmable mode The thermostat is factory-set as a 7-day programmable thermostat. To set it as a non-programmable thermostat, proceed as follows:

1. From the installer’s setup menu, press to select Horaire (schedule) and press Ok .
2. Press or to select Non and press Ok .

Copy Use this function to copy the configuration settings, the schedule settings or both to other EConnect™ wireless thermostats in your house. This function is available only if the thermostat is connected either to a remote control or outdoor sensor. The settings are copied to other thermostats connected to the remote control or outdoor sensor.

1. From the installer’s setup menu, press as needed to select Copie and press Ok .
2. Press or to select Horaire (schedule), Configuration or both. Press Ok .
3. Patientez (wait) may appear for several minutes. When SUCC (success) appears, press Sortir (exit) to return to home menu.
Page 15 of the Aube Technologies TA7210 user manual — Installer setup table
Page 15 · cliquer pour agrandir
Page 15

Keypad lock By default, the keypad lock is disabled.

Aube Technologies TA7210 — Installer setup table diagram (page 15)
Fig. 22 · Installer setup table

If you leave at Non (no), the homeowner will have full access to all thermostat functions.

If you select Part (Partial), the homeowner can change the room temperature only.

If you select Oui (yes), the buttons will not appear on the screen. To unlock, go to Installer Setup (see page 11).

1. From the installer’s setup menu, press to select Verrouiller (lock) and press Ok .
2. Press or to select Oui (Yes), Part (Partial) or Non (No). Press Ok .
Page 16 of the Aube Technologies TA7210 user manual — Installer setup table
Page 16 · cliquer pour agrandir
Page 16

Zone name The zone name is used to identify the thermostat on the wireless remote control. By default, the zone name is Thermostat (zone name 52). If you have a wireless remote control and more than one wireless thermostat, change the zone name of the thermostat to identify it from the other thermostats. For example, if the thermostat is in the living room, set the zone to 31.

1. From the installer’s setup menu, press to select Connexion (link) and press Ok .
2. Press Ok to select Zone .
3. Press or to set the zone name (see page 17). Press Ok .
4. Press Sortir (exit) once to return to installer’s setup menu or twice to return to home screen.
Page 17 of the Aube Technologies TA7210 user manual — Zone name list
Page 17 · cliquer pour agrandir
Page 17

Zone name list

Aube Technologies TA7210 — Zone name list diagram (page 17)
Fig. 23 · Zone name list

1 Basement 16 Exercise Room 30 Library 44 Porch

2 Bathroom 17 Family Room 31 Living Room 45 Rec Room

3 Bathroom 1 18 Fireplace 32 Lower Level 46 Sewing Room

4 Bathroom 2 19 Foyer 33 Master Bath 47 Spa

5 Bathroom 3 20 Game Room 34 Master Bed 48 Storage Room

6 Bedroom 21 Garage 35 Media Room 49 Studio

7 Bedroom 1 22 Great Room 36 Music Room 50 Sun Room

8 Bedroom 2 23 Guest Room 37 Nursery 51 Theater

9 Bedroom 3 24 Gym 38 Office 52 Thermostat

10 Bedroom 4 25 Kid's Room 39 Office 1 53 Upper Level

11 Boat House 26 Kitchen 40 Office 2 54 Utility Room

12 Bonus Room 27 Kitchen 1 41 Pantry 55 Walk In Closet

13 Computer Room 28 Kitchen 2 42 Play Room 56 Wine Cellar

14 Den 29 Laundry Room 43 Pool Room 57 Workshop

Adaptive Intelligent Recovery (horaire anticipé) Available only if you use the thermostat in programmable mode. When Adaptive Intelligent Recovery is on, the thermostat “learns” how long your heater takes to reach the set temperature. The thermostat will then determine when to activate heating so the desired temperature is attained at the desired time. The thermostat re- assesses the heating start time daily based on the previous day’s performance. When Adaptive Intelligent Recovery is off, heating starts at the set time. To turn off Adaptive Intelligent Recovery, proceed as follows:

Aube Technologies TA7210 — Zone name list diagram (page 17)
Fig. 24 · Zone name list
1. From the installer’s setup menu, press to select Horaire Anticipé (Adaptive Intelligent Recovery) and press Ok .
2. Press or to select Non (no) and press Ok .
Page 18 of the Aube Technologies TA7210 user manual — Zone name list
Page 18 · cliquer pour agrandir
Page 18

Anti-freeze When this function is on, the EIM will maintain the room temperature at 13°C (55°F) if it loses communication with the thermostat or if the thermostat sensor is defective.

Aube Technologies TA7210 — Zone name list diagram (page 18)
Fig. 25 · Zone name list

Leave the protection on unless the EIM is installed in a junction box in a separate room from the heater.

To turn off the Anti-freeze protection, proceed as follows:

menu, press as needed to select Hors-Gel (anti-freeze) and press Ok.

2. Press or to select Non (no). Press Ok .

System test 1) From the Home screen, press until the setpoint temperature is above the room ambient temperature by at least 2°. Press Temporaire (temporary). 2) Wait for Chauffe (heat) to display on the thermostat. 3) Verify if the heater becomes hot. 4) Press Annuler (cancel) to return the thermostat to its previous mode.

Page 19 of the Aube Technologies TA7210 user manual — Mounting on a wall (Method B)
Page 19 · cliquer pour agrandir
Page 19

Mount thermostat and outdoor sensor

  • Follow the guidelines below when mounting the thermostat:
  • Do NOT install the thermostat in an area where it can be exposed to water or rain.
  • Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimney or stove pipes.
  • For a new installation, choose a location about 1.5 m (5 ft.) above the floor.
  • Install the thermostat on an inside wall facing the heater.
  • Keep the thermostat's top and bottom air vents (openings) clean and unobstructed at all times.

Two mounting plates are provided for mounting the thermostat on the wall or on a junction box. Use Method A for a slimmer thermostat look. Choose Method B if you prefer not to make an opening in the wall. Method C must be used for installation on a junction box.

Recessed mounting on a wall (Method A)

Aube Technologies TA7210 — Recessed mounting on a wall (Method A) diagram (page 19)
Fig. 26 · Recessed mounting on a wall (Method A)

Mark the four corners and join them to create a rectangular outline.

Cut along the outline to create an opening in the wall.

Secure the mounting plate to the wall using provided wall anchors and screws.

Mounting on a wall (Method B)

Mounting on a junction box (Method C)

Installing faceplate

Aube Technologies TA7210 — Mounting on a wall (Method B) diagram (page 19)
Fig. 27 · Mounting on a wall (Method B)

Secure the mounting plate to the wall using provided wall anchors and screws.

Complete the thermostat installation by pressing the faceplate against the mounting plate.

Secure the mounting plate to a junction box using provided mechanical screws.

Page 20 of the Aube Technologies TA7210 user manual — Display Description
Page 20 · cliquer pour agrandir
Page 20

Mounting the outdoor sensor (optional)

Mount the sensor vertically on an exterior wall, at least 6 inches below any overhang. Choose a location protected from direct sunlight. Place sensor securely in bracket, facing away from wall.

Error codes

Display Description

LO The indoor temperature is below 0°C (32°F).

HI The indoor temperature is above 60°C (140°F).

- - The temperature reading is currently unavailable or the sensor is defective.

E128 The wireless network setup must be redone.

E129 Attempting to connect incompatible wireless devices.

E130 Invalid address. Call customer assistance.

E134 Low signal strength. Move wireless device to a different location and try again.

E137 Maximum number of devices is exceeded.

E138 Make sure Connected light on EIM is flashing and you are 2+ feet away from EIM.

E152 Incorrect order. Make sure to link EIM to proper thermostat.

Page 21 of the Aube Technologies TA7210 user manual — Verifying the signal strength between the EIM and the thermostat
Page 21 · cliquer pour agrandir
Page 21

Verifying the signal strength between the EIM and the thermostat

Aube Technologies TA7210 — Verifying the signal strength between the EIM and the thermostat diagram (page 21)
Fig. 28 · Verifying the signal strength between the EIM and th…

If you have more than one EIM linked to the thermostat, the displayed value is between the thermostat and the first-linked EIM. The signal strength ranges from 0 (no signal) to 10 (strongest).

1. From the home screen, press and hold the right center button for 5 secs.
2. Press to select Connexion (link) and press Ok .
3. Press to select Signal and press Ok .
4. The signal strength is displayed. Press Sortir (exit) twice to return to installer’s setup menu or three times to return to home screen.

Thermostat To replace the thermostat, install batteries in the new thermostat (see page 7) and link it to the wireless network (see page 8). To customize the thermostat, see pages 11-18.

If more than one EIM were linked to the old thermostat, you can link the new thermostat from any one of these EIMs.

Page 22 of the Aube Technologies TA7210 user manual — Equipment interface module (EIM)
Page 22 · cliquer pour agrandir
Page 22

Remote control or outdoor sensor To replace the remote control or the outdoor sensor, install batteries in the new device (see page 7) and link it to the wireless network (see page 10).

If more than one EIM are linked to the same thermostat, you can link the remote control or the outdoor sensor from any one of these EIMs. If you have more than one wireless thermostat, link the remote control or the outdoor sensor from one EIM of each of the wireless thermostats.

Equipment interface module (EIM)

If you have a remote control: 1) Press and hold, for about 3 seconds, the blank space (or arrow if present) in the lower right corner of the screen until the display changes. 2) Press REMOVE, then YES.

If you have only one EIM linked to the thermostat: Remove the defective EIM, install a new one (see pages 3 - 6) and proceed as follows:

1) Check if the thermostat displays 0 Relais connecté(s) (0 relay connected) as shown on the right. If so, go straight to step 5. 2) From the home screen, press and hold the right center button for 5 secs. 3) Press to select Connexion (link) and press Ok. 4) Press to select Enlever (remove) and press Ok. The thermostat will display 0 Relais connecté(s) (0 relay connected). 5) Follow the procedures on pages 7-11 to set up a new network with the new EIM.

If you have more than one EIM linked to the thermostat: Follow the procedure below to identify the defective EIM(s) and to re-establish all links:

1) Remove the antenna cover from each EIM in the network by squeezing the cover (as shown by red arrows) and pulling it out. 2) Press, for 10 seconds, the Connect button on every EIM that has a green light. Repeat this step until none of the EIM shows a green light. 3) Check if the thermostat displays 0 Relais connecté(s) (0 relay connected) as shown on the right. If so, go straight to step 7. 4) From the home screen, press and hold the right center button for 5 secs. 5) Press to select Connexion (link) and press Ok. 6) Press to select Enlever (remove) and press Ok. The thermostat will display 0 Relais connecté(s) (0 relay connected). 7) Follow the procedures on pages 7-11 to create a new network. You will know that an EIM is defective if its light turns red or the thermostat displays an error code when you try to link the EIM to the network. Replace it before continuing to link other EIMs.

Press here

Page 23 of the Aube Technologies TA7210 user manual — Accessories & Replacement Parts
Page 23 · cliquer pour agrandir
Page 23

Specifications & replacement parts

Thermostat

Temperature setpoint range: 5°C - 30°C (41°F - 86°F) Temperature setpoint resolution: 0.5°C (1°F) Temperature display range: 0°C - 40°C (32°F - 104°F) Temperature display resolution: 0.5°C (1°F) Heating cycle rate: 15 minutes Programming: 5-2 days, 7 days, 1 day or Non-Programmable

Operating Ambient Temperature

Thermostat: 0°C - 50°C (32°F - 122°F) Remote control: 0°C - 48.9°C (32°F - 120°F) EIM (relay): -20°C - 60°C (-4°F - 140°F) EIM (antenna): -20°C - 60°C (-4°F - 140°F) Outdoor air sensor: -40°C - 60°C (-40°F - 140°F)

Operating Relative Humidity

Thermostat: 5% - 90% (non-condensing) Remote control: 5% - 90% (non-condensing) EIM (relay): 5% - 95% (non-condensing) EIM (antenna): 5% - 95% (non-condensing) Outdoor air sensor: 0% - 100% (condensing)

Physical Dimensions (height, width, depth)

Thermostat: 130 x 82 x 29 mm (5.13 x 3.22 x 1.14 inches) EIM (relay): 73 x 63 x 29 mm (3.03 x 2.49 x 1.28 inches) EIM (antenna): 71 x 62 x 33 mm (2.89 x 2.63 x 1.16 inches) Outdoor air sensor: 127 x 89 x 43 mm (5.00 x 3.50 x 1.68 inches)

Electrical Ratings (EIM)

Supply: 100-240 VAC, 50/60 Hz Minimum load: 0.4 A (resistive only) Maximum load: 12.5 A (resistive only)

Accessories & Replacement Parts

Item Part Number Equipment Interface Module (EIM) ATM100-SPK Remote control REM5000R1001 Outdoor air sensor C7089R1013 Antenna cover (white) 50055751-002 Antenna cover (almond) 50055751-004

Page 24 of the Aube Technologies TA7210 user manual — Regulatory information
Page 24 · cliquer pour agrandir
Page 24

Regulatory information

FCC Compliance Statement (Part 15.19) (USA only) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation.

FCC Warning (Part 15.21) (USA only) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC Interference Statement (Part 15.105 (b)) (USA only) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

EIM, thermostats and outdoor sensor To comply with FCC and Industry Canada RF exposure limits for general population/ uncontrolled exposure, the antenna(s) used for these transmitters must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

Remote control This portable transmitter with its antenna complies with FCC and Industry Canada RF exposure limits for general population/uncontrolled exposure. This device must not be co-located or operating in conjunction with any other antenna or transmitter.

Section 7.1.3 of RSS-GEN Operation is subject to the following two conditions: 1) This device may not cause interference, and 2) This device must accept any interference, including interference that may cause undesired operation of the device.

Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate using an antenna of type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is not more than that necessary for successful communication.

Page 25 of the Aube Technologies TA7210 user manual — Regulatory information
Page 25 · cliquer pour agrandir
Page 25
Page 25 of the Aube Technologies TA7210 user manual — Regulatory information
Page 26 of the Aube Technologies TA7210 user manual — Automation and Control Systems
Page 26 · cliquer pour agrandir
Page 26
Aube Technologies TA7210 — Automation and Control Systems diagram (page 26)
Fig. 29 · Automation and Control Systems

or call Honeywell Customer Care toll-free at 1-800-831-2823.

Automation and Control Systems

Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 http://customer.honeywell.com

Honeywell Limited 705 Montrichard Saint-Jean-sur-Richelieu, Québec, J2X 5K8 www.aubetech.com

69-2472EF-01 06-2011 © 2011 Honeywell International Inc. ® U.S. Registered Trademark. All rights reserved. Printed in USA

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Aube Technologies TA7210

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Aube Technologies TA7210

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Aube Technologies TA7210 manuel PDF

52 pages·9.3 MB·Thermostat·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…