During power-up, the TH134 perform a series of test for approxi- mately 5 seconds. Afterwards, the programmer displays the follow- ing:
The installation must be performed by an electrician. The program- mer must be installed on an electrical box.
All three zones are in comfort mode.
Flashes to indicate that the time and day must be set.
n Loosen the locking screw (the screw is captive and cannot be completely removed). o Pull and lift the bottom of the faceplate to remove it from its mounting plate.
The programmer is in manual mode.
Zone 1 is selected.
n Press . The hours display flashes. o Set the hours using the buttons. p Press . The minutes display flashes. q Set the minutes using the buttons. r Press . The day display flashes. s Set the day using the buttons. t Press to exit the time and day settings
Connect power to terminals L (line) and N (neutral).
Connect the pilot wire inputs of the thermo- stats to terminals FP1, FP2 and FP3.
The terminals accept wire thick- nesses between 0,32 and 2,1 mm2.
!"# "$% &' " (&' !) # ")
Connect terminals 2 and 1 of the CT240 to terminals L and TEL of the programmer respectively.
.If the “setback” and “off’ orders received by a heating unit are reversed, reverse the “Ph” and the “N” wires on the heating unit.
!"# "$% &' " (&' !) # ")
Connect the terminals of one of the outputs of CT241 to terminals L and TEL of the programmer .
!
Transmits the order selected via one of the order buttons. To use this mode: n Select the zone by pressing the Zone but- ton. (Press for 3 seconds to select all 3 zones.) o Select the manual (Man) mode by press- ing the Man/Auto button. p Select the order by pressing the appropriate order button.
&* " +, !&* +!- &' ./.!"*
Connect the normally-open relay of the home automation system terminals L and TEL of the programmer.
' ")0/ * +' +0")
Connect the pilot wire output of the energy manager to the TEL input of the programmer.
n Fix the mounting plate to the wall. o Install the faceplate on the mounting plate and lock them together using the locking screw.
The orders are sent to each zone according to the schedule programmed for that zone. To use this mode: n Select the zone by pressing the Zone but- ton. (Press for 3 seconds to select all 3 zones.) o Select the Auto mode by pressing the Man/Auto button.
/$+..
You can bypass the automatic mode for 2 hours. At the end of the 2 hours, the programmer returns to the automatic mode. n Select the zone using the Zone button. (Press for 3 seconds to select all 3 zones.) o Press the desired order button.
The auto mode icon flashes during the bypass.

o Select the zone using the Zone button. (Press for 3 seconds to select all 3 zones.) p Select the program using the PGM button. q Set the program start time. r Select the mode by pressing the corresponding button. s Repeat steps 3 to 5 for the remaining programs for the selected zone. t Go to step 2 if you wish to select another zone. u Press to exit programming.
Whenever an order is received via the remote input, it becomes the active order for all 3 zones. To know which orders can be initiated by the energy manager, the phone controller or the home automa- tion system, see the table on page 1. The is displayed when signals are received via the remote input.
/$+..
Orders received via the remote input have priority over orders initi- ated via the TH134 programmer. However, you can bypass the remote input order for each zone for 2 hours. At the end of the 2 hours, the remote input order becomes active again. n Select the zone using the Zone button. (Press for 3 seconds to select all 3 zones.) o Press the desired order button.
TH134 will automatically exit programming if no button is pressed for the last 60 seconds.
The icon flashes during the bypass.
The same schedule is used by default for all 3 zones as shown below.
If no program is selected for a particular day, TH134 uses the order of the last program until the start of the next program.
r Repeat steps 3 and 4 for the each remaining day. s Go to step 2 if you wish to select another zone. t Press to exit.
Enter your settings in the following table.
! "
$ %&
$ %&
Use the following procedure to select the order and the start time for each of the 4 programs for each zone. The settings of each pro- gram will be the same for each day. However, you can then select which programs to be executed for each day and for each zone. n Press the PGM to start programming.
$ %&
" "#

- # &! 2- )" &, !$, !: 60 mA per output / 230 VCA
+3- * , * # &+1: 10 units per pilot wire output (FP)
$")+!- ' 0 "* $")+!, )": 0 - 50°C
, !&* +!- ( +(!- &' : 1Y type
' 4- )&' * "' !: normally polluted
"* &)/ !/$": program settings are permanently saved time settings are saved for 4 hours during power outage "* &!" - ' $, !: universal relay (230 VCA / 500 µA) or pilot wire
- )" !% - (6' "..: 0,32 - 2,1 mm2.
This product is guaranteed against workmanship defects for a three-year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions.
The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installa- tion. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commit- ment. AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product.
The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address.
For any questions regarding the product installation or operation, contact our technical support team at:
705, Montrichard Saint-Jean-sur-Richelieu, Québec J2X 5K8 Canada
Tel. : (450) 358-4600 1-800-831-AUBE service@aubetech.com
10, rue Ampère 95500 Gonesse, France Tel. : 33 (0) 1 34 07 99 00 Fax : 33 (0) 1 34 07 99 19 advaube@comintes.com
· !
Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.