This product contains chemicals, known to the State of California to cause cancer, and birth defects or other reproductive harm. Wash hands after handling.
Do not operate this unit until you read and understand this instruction manual for safety, operation and maintenance instructions.
Risk of explosion or fire What can happen How to prevent it • It is normal for electrical con- tacts within the motor and pressure switch to spark.


RISK of Bursting

Risk from Flying Objects What can happen How to prevent it • The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt, chips, loose particles, and small objects at high speed, resulting in property damage or personal injury.

RISK OF Hot surfaces What can happen How to prevent it • Touching exposed metal such as the compressor head, engine head, engine exhaust or outlet tubes, can result in serious burns.
Risk from Moving Parts What can happen How to prevent it • Moving parts such as the pulley, flywheel, and belt can cause serious injury if they come into contact with you or your clothing.

risk from noise What can happen How to prevent it • Under some conditions and duration of use, noise from this product may contribute to hearing loss.
FOR FUTURE USE

Model No. C2025 Bore 1.875" Stroke 1.250" Voltage/Hz-Single Phase 120/60 Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity (Gallon) 2.5 Approximate Cut-in Pressure 120 psiG Approximate Cut-out Pressure 150 psiG SCFM @ 40 psiG *3.7 SCFM @ 90 psiG *2.6 *Tested per ISO 1217 Refer to Glossary for abbreviations.
Become familiar with these terms before operating the unit. CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. psiG: Pounds per square inch gauge; a unit of measure of pressure. Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety labo- ratories and meet the applicable Standards for Safety. Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory. When the tank pressure drops to a certain lower level the motor will restart automatically. The low pressure at which the motor automatically restarts is called "cut-in" pressure. Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off, protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called "cut- out" pressure. Branch Circuit: Circuit carrying electricity from electrical panel to outlet.
This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is recommended that a 50%-75% average duty cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given hour.
Accessories for this unit are available at the store the unit was purchased.

ASSEMBLY Unpacking 1. Remove unit from carton and discard all packaging.
Risk of Electrical Shock. In the event of a short circuit, ground- ing reduces the risk of shock by providing an escape wire for the electric cur- rent. This air compressor must be properly grounded.
The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations). 1. The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet. IMPORTANT: The outlet being used must
be installed and grounded in accordance with all local codes and ordinances. 2. Make sure the outlet being used has the same configuration as the ground- ed plug. DO NOT USE AN ADAPTER. See illustration. 3. Inspect the plug and cord before each use. Do not use if there are signs of damage. 4. If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.
Risk of Electrical Shock. IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK.
Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician. Repairs to the cord set or plug MUST be made by a qualified electrician.
Plug · Grounded Outlets · Grounding Pin

The use of an undersized extension cord will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using an extension cord, increase the working reach of the air hose by attach- ing another length of hose to its end. Attach additional lengths of hose as needed.
Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit require- ments.
Risk of Opertion.Certain air compressors can be operated on a 15 amp circuit if the following conditions are met.
1. Voltage supply to circuit must comply with the National Electrical Code. 2. Circuit is not used to supply any other electrical needs. 3. Extension cords comply with specifications. 4. Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse. NOTE: If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked "D" in Canada and "T" in the US. If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.

Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future refer- ence.

Description of Operation Become familiar with these controls before operating the unit. On(I)/Off(O) Switch: Place this switch in the On (I) position to provide automatic power to the pressure switch and Off (O) to remove power at the end of each use. Pressure Switch (not shown): The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out" pressure. Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting). Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pres- sure in the tank. Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure. Regulator: Controls the air pressure shown on the outlet pressure gauge. Turn regulator knob clockwise to increase pressure and counterclockwise to decrease pressure. Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.

Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet. Drain Valve: The drain valve is located at the base of the
air tank and is used to drain condensation at the end of each use. Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches "cut-

out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank. Motor Overload Protector (not shown): The motor has an automatic reset thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. The compressor will automatically restart after the motor cools. How to Use Your Unit
How to Stop 1. Set the On/Off switch to "Off".
Do not operate this unit until you read and understand this instruction manual for safety, operation and maintenance instructions.
Risk of Unsafe Operation. Serious damage may result if the following break-in instructions are not closely followed.
This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. 1. Make sure the On/Off switch is in the "Off" position. 2. Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.) 3. Open the drain valve (counter-clockwise) fully to permit air to escape and pre- vent air pressure build up in the air tank during the break-in period. 4. Move the On/Off switch to "On" position. The compressor will start. 5. Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank. 6. After 15 minutes, close the drain valve by turning clockwise. The air receiver will fill to "cut-out" pressure and the motor will stop. The compressor is now ready for use.
Before Each Start-Up 1. Set the On/Off switch to "Off". 2. Turn the regulator knob counter-clockwise to set the outlet pressure to zero. 3. Attach hose and accessories.
Risk of unsafe operation. Firmly grasp air hose in hand when installing or disconnecting to prevent hose whip.
Risk of unsafe operation. Do not use damaged or worn accessories.

Risk of Bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.
Risk of unsafe operation. Compressed air from the unit may contain water condensation and oil mist. Do not spray unfiltered air at an item that could be damaged by moisture. Some air tools and accessories may require filtered air. Read the instructions for the air tools and accessories.
How to Start 1. Set the On/Off switch to "On" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure. 2. Turn regulator knob clockwise to increase pressure and stop when desired pressure is reached.
If any unusual noise or vibration is noticed, stop the compres- sor immediately and have it checked by a trained service technician.
The compressor is ready for use.
Daily or after each use
Check Safety Valve X
Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.
Risk of Bursting. If the safety valve does not work properly, over-pressurization may occur, causing air tank rupture or an explosion.
Risk from Flying Objects. Always wear certified safety equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields. 1. Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.
Before each use · Drain Tank X

Risk of Unsafe Operation. Risk from noise. Air tanks contain high pressure air. Keep face and other body parts away from outlet of drain. Use ANSI Z87.1 eye protection (CAN/CSA Z94.3) when draining as debris can be kicked up into face. Use ear protection [(ANSI S12.6 (S3.19) hearing protection] as air flow noise is loud when draining.
Risk of Bursting. Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.
Risk of Property Damage. Drain water from air tank may con- tain oil and rust which can cause stains. 6. After the water has been drained, close the drain valve. The air compressor can now be stored. NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, the reinstalled.
ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN.
Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool. To Replace or Clean Check Valve 1. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section. 2. Unplug unit. 3. Remove the hose by removing the

hose clamp. NOTE: The hose clamp is not reusable. You must purchase a new hose clamp, purchase a standard hose clamp at a local hardware store. 4. Unscrew the check valve (turn coun- ter-clockwise) using a socket wrench. 5. Make sure the valve disc moves freely inside the check valve and the spring holds the disc in the upper, closed position. The check valve may be cleaned with a solvent, such as paint and varnish remover. 6. Apply sealant to the check valve threads. Reinstall the check valve (turn clock- wise).
Hose Clamp · Check Valve

remove the gauges, quick connect, and safety valve from the regulator manifold.

Safety Valve Regulator Manifold
Gauges · Hose Clamp · Quick Connects

Before you store the air compressor, make sure you do the following: 1. Review the Maintenance section on the preceding pages and perform sched- uled maintenance as necessary. 2. Set the On/Off switch to "Off" and unplug unit. 3. Turn the regulator counterclockwise and set the outlet pressure to zero. 4. Remove the air tool or accessory. 5. Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring. 6. Drain water from air tank by opening drain valve on bottom of tank.
Risk of Bursting. Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.
SERVICE REPLACEMENT PARTS Use only identical replacement parts. For a parts list or to order parts, visit our website at servicenet.porter-cable.com. You can also order parts from your near- est factory-owned branch, or by calling our Customer Care Center at 1-888-848- 5175 to receive personalized support from highly-trained technicians. SERVICE AND REPAIRS All quality tools will eventually require servicing and/or replacement of parts. For information about Porter-Cable, its factory-owned branches, or an Authorized Warranty Service Center, visit our website at deltaportercable.com or call our Customer Care Center at (888)-848-5175. All repairs made by our service cen- ters are fully guaranteed against defective material and workmanship. We cannot guarantee repairs made or attempted by others. You can also write to us for information at PORTER-CABLE, 4825 Highway 45 North, Jackson, Tennessee 38305 - Attention: Product Service. Be sure to include all of the information shown on the nameplate of your tool (model number, type, serial number, etc.).

Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, com- pressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
Excessive tank pressure - safety valve pops off.
Pressure switch does not shut off motor when compressor reaches "cut-out" pressure.
Move On/Off lever to the "Off" position, if the outfit does not shut off contact a Trained Service Technician.
Pressure switch "cut- out" too high.
Contact a Trained Service Technician.
Air leaks at fittings. Tube fittings are not tight enough.
Tighten fittings where air can be heard escaping. Check fittings with soapy water solution. Do Not Overtighten.
Air leaks in air tank or at air tank welds.
Defective air tank. Air tank must be replaced. Do not repair the leak.
Risk bursting. Do not drill into, weld or otherwise modify air tank or it will weaken. The tank can rupture or explode.
Air leaks between head and valve plate.
Leaking seal. Contact a Trained Service Technician.
Air leak from safety valve.
Possible defect in safety valve.
Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced.
Knocking Noise. Possible defect in safety valve.
Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced.

Pressure reading on the regulated pressure gauge drops when an accessory is used.
It is normal for "some" pressure drop to occur.
If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in the Operation Section. NOTE: Adjust the regulated pressure under flow conditions (while accessory is being used).
Compressor is not supplying enough air to operate accessories.
Prolonged excessive use of air.
Decrease amount of air usage.
Compressor is not large enough for air requirement.
Check the accessory air requirement. If it is higher than the SCFM or pressure supplied by your air compressor, you need a larger compressor.
Hole in hose. Check and replace if required.
Check valve restricted. Remove and clean, or replace.
Air leaks. Tighten fittings.
Regulator knob has continuous air leak.
Damaged regulator. Replace.
Regulator will not shut off air outlet.
Damaged regulator. Replace.

Motor will not run. Fuse blown, circuit breaker tripped.
Check fuse box for blown fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit.
Check for proper fuse. You should use a time delay fuse.
Check for low voltage problem.
Check the extension cord.
Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit.
Extension cord is wrong length or gauge.
Check the extension cord.
Loose electrical connections.
Check wiring connection inside terminal box.
Faulty motor. Have checked by a Trained Service Technician.
Motor overload protection switch has tripped
Refer to "Motor Overload Protection" under Operation. If motor overload protection trips frequently, contact a Trained Service Technician

Porter-Cable industrial tools are warranted for one year from date of purchase. We will repair, without charge, any defects due to faulty materials or workmanship. For warranty repair information, call (888)-848-5175. This warranty does not apply to accessories or damage caused where repairs have been made or attempted by others. This warranty gives you specific legal rights and you may have other rights which vary in certain states or provinces. Latin America: This warranty does not apply to products sold in Latin America. For products sold in Latin America, see country specific warranty information contained either in the packaging, call the local company or see website for warranty information. FREE WARNING LABEL REPLACEMENT: If your warning labels become illegible or are missing, call (888)-848-5175 for a free replacement.
RUSTED TANK CAN CAUSE EXPLOSION AND SEVERE OR FATAL INJURY. DRAIN TANK DAILY OR AFTER EACH USE.
UN RÉSERVOIR ROUILLÉ PEUT PROVOQUER UNE EXPLOSION ET CAUSER DES BLESSURES GRAVES OU FATALES. VIDANGEZ LE RÉSERVOIR JOURNELLEMENT OU APRÈS CHAQUE UTILISATION.
INCORRECT USE CAN CAUSE HAZARDS. FOLLOW THESE INSTRUCTIONS:
RISK OF BURSTING. MAKE SURE THE COMPRESSOR OUTLET PRES- SURE IS SET LOWER THAN THE MAXIMUM OPERATING PRESSURE OF THE SPRAY GUN OR TOOL. BEFORE STARTING THE COMPRESSOR, PULL THE RING ON THE SAFETY VALVE TO MAKE SURE THE VALVE MOVES FREELY. DRAIN WATER FROM TANK AFTER EACH USE.
RISK OF FIRE OR EXPLOSION. DO NOT SPRAY A FLAMMABLE OR COMBUSTIBLE LIQUID OR PAINT NEAR SPARKS, FLAMES, PILOT LIGHTS, OR IN A CONFINED AREA. THE SPRAY AREA MUST BE WELL VENTILATED. KEEP COMPRESSOR AT LEAST 20 FEET AWAY FROM SPRAY AREA. DO NOT CARRY AND OPERATE THE COMPRESSOR, OR ANY OTHER ELECTRICAL DEVICE NEAR THE SPRAY AREA. NEVER SMOKE WHEN SPRAYING. USE A MINIMUM OF 25 FEET OF HOSE TO CONNECT A SPRAY GUN TO THE COMPRESSOR. RISK OF PERSONAL INJURY. NEVER SPRAY COMPRESSED AIR OR MATERIAL AT THE BODY. RISK OF ELECTRICAL SHOCK. DO NOT EXPOSE TO RAIN. STORE INDOORS. READ OWNER'S MANUAL FOR COMPLETE SAFETY, OPERATION, AND REPAIR INSTRUCTIONS.
EL USO INDEBIDO PUEDE GENERAR RIESGOS. SEGUIR ESTAS INSTRUCCIONES: RIESGO DE ESTALLIDO. ASEGÚRESE QUE LA VÁLVULA DE SALIDA DEL COMPRESOR ESTE REGULADA POR DEBAJO DEL MÁXIMO DE LA PRESIÓN DE OPERACIÓN DE LA PISTOLA ROCIADORA O HERRAMIENTA. ANTES DE ARRANCAR EL COMPRESOR, TIRAR DEL ANILLO EN LA VÁLBULA DE SEGURIDAD PARA ASEGURARSE QUE LA VÁLVULA SE MUEVE LIBREMENTE. DRENAR EL AGUA DEL TANQUE DESPUÉS DE CADA USO. RIESGO DE FUEGO O EXPLOSIÓN. NO ROCIAR LÍQUIDO NI PINTURAS INFLAMABLES O COMBUSTIBLES CERCA DE CHISPAS, LLAMAS, LLAMAS DE PILOTO O EN ÁREAS CERRADAS. EL ÂREA DE TRABAJO DEBE ESTAR BIEN VENTILADA. MANTENER EL COMPRESOR ALEJADO POR LO MENOS 20 PIES DEL AREA DE PINTURA. NO LLEVAR NI OPERAR EL COMPRESOR NI DISPOSITIVO ELÉCTRICO ALGUNO CERCA DEL AREA DEL ROCIADO. NUNCA FUME EN EL ÁREA DEL ROCIADO. USAR UNA MANGUERE DE UN MÍNIMO DE 25" PARA CONECTAR LA PISTOLA AL COMPRESOR. RIESGO DE DAÑOS PERSONALES. NUNCA DISPARE AIRE COMPRIMIDO MI MATERIAL AL CUERPO. RIESGO DE CHOQUE ELÉCTRICO. NO EXPONER A LLUVIA. ALMACENAR EN INTERIORES. PARA SEGURIDAD COMPLETA, OPERACIÓN E INSTRUCCIONES PARA REPARAR, LEER EL MANUAL DEL OPERADOR.
UNE UTILISATION INCORRECTE PEUT ÊTRE DANGEREUSE. SUIVEZ LES INSTRUCTIONS CI-DESSOUS: RISQUE D'ECLATEMENT. ASSUREZ-VOUS QUE LA PRESSION DE SORTIE DU COMPRESSEUR EST RÉGLÉE À UN NIVEAU INFÉRIEUR À LA PRESSION D'UTILISATION MAXIMUM DU PISTOLET VAPORISATEUR OU DE L'ACCESSOIRE. AVANT DE DÉMARRER LE COMPRESSEUR, TIREZ SUR L'ANNEAU DE LA SOUPAPE DE SÛRETÉ POUR VOUS ASSURER QU'ELLE FONCTIONNE LIBREMENT. VIDANGEZ L'EAU DU RÉSERVOIR À AIR APRÈS CHAQUE UTILISATION. RISQUE D'INCENDIE OU D'EXPLOSION. NE PAS VAPORISER UN LIQUIDE OU UN PEINTURE INFLAMMABLE OU COMBUSTIBLE PRÈS D'ÉTINCELLES, DE FLAMMES, DE VEILLEUSES NI DANS UN ENDROIT RESTREINT OU RENFERMÉ. L'AIRE DE VAPORISATION DOIT ÊTRE BIEN AÉRÉE. GARDEZ LE COMPRESSEUR À UNE DISTANCE D'AU MOINS 20 PIEDS DE LA SURFACE À VAPORISER. NE PORTEZ PAS LE COMPRESSEUR ET NE L'UTILISEZ PAS NI AUCUN AUTRE APPAREIL ÉLECTRIQUE À PROXIMITÉ DE L'AIRE DE VAPORISATION. NE FUMEZ JAMAIS QUAND VOUS VAPORISEZ. UTILISEZ UN FLEXIBLE D'AIR D'UNE LONGUEUR MINIMUM DE 25 PIEDS POUR RELIER LE PISTOLET VAPORISATEUR AU COMPRESSEUR. RISQUE DE DANGER CORPOREL. NE DIRIGEZ JAMAIS UN JET D'AIR COMPRIMÉ OU DE LIQUIDE VERS VOTRE CORPS. RISQUE DE CHOC ÉLECTRIQUE. N'EXPOSEZ PAS LE COMPRESSEUR À LA PLUIE. REMISEZ-LE À L'INTÉRIEUR. LISEZ LE MANUEL DE L'UTILISATEUR POUR DES INSTRUCTIONS COMPLÈTES CONCERNANT LA SÉCURITÉ, L'UTILISATION ET LES RÉPARATIONS.
Problèmes fréquents, causes probables et solutions.
| Problème | Cause possible | Solution | |
|---|---|---|---|
| Pressure reading on the regulated pressure gauge drops when an accessory is used. | It is normal for "some" pressure drop to occur. | If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in the Operation Section. NOTE: Adjust the regulated pressure under flow conditions (while accessory is being used). | p.17 |
| Compressor is not supplying enough air to operate accessories. | Prolonged excessive use of air. Compressor is not large enough for air requirement. Hole in hose. Check valve restricted. Air leaks. | Decrease amount of air usage. Check the accessory air requirement. If it is higher than the SCFM or pressure supplied by your air compressor, you need a larger compressor. Check and replace if required. Remove and clean, or replace. Tighten fittings. | p.17 |
| Regulator knob has continuous air leak. | Damaged regulator. | Replace. | p.17 |
| Regulator will not shut off air outlet. | Damaged regulator. | Replace. | p.17 |
| Motor will not run. | Fuse blown, circuit breaker tripped. Extension cord is wrong length or gauge. Loose electrical connections. Faulty motor. Motor overload protection switch has tripped | Check fuse box for blown fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit. Check for proper fuse. You should use a time delay fuse. Check for low voltage problem. Check the extension cord. Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit. Check the extension cord. Check wiring connection inside terminal box. Have checked by a Trained Service Technician. Refer to "Motor Overload Protection" under Operation. If motor overload protection trips frequently, contact a Trained Service Technician | p.18 |